• 제목/요약/키워드: 2 Stage Valve

검색결과 104건 처리시간 0.024초

Comparisons of Performance in CO2 Systems with Operating Conditions (운전조건 변화에 따른 이산화탄소 냉방시스템들의 성능 비교)

  • Bae, Kyung-Jin;Shin, Eun-Sung;Cho, Hong-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1484-1490
    • /
    • 2009
  • Since the cooling performance of a $CO_2$ cooling cycle is varied significantly with a variation of refrigerant charge amount and outdoor temperature, the reliability of $CO_2$ system is down. In this study, the performance characteristics of three kinds of $CO_2$ systems were measured and analyzed by varying refrigerant charge amount and outdoor temperature so as to study the characteristics of variation with cycle option. The applied system options are the single-stage compression(1C-1E) system, two-stage compression with 1-EEV(2C-1E) system, and two-stage compression with 2-EEV(2C-2E) system. The performances of two-stage compression with 2-EEV system were less sensitive than those of other systems and the system operated safely and steadily for wide charge amount. The performance of the two-stage compression with 1-EEV(2C-1E) system was the most sensitive to the charge amount, and that of the single-stage compression(1C-1E) system varied a lot with outdoor temperature.

  • PDF

Experimental Study on a GM-type Two-Stage Pulse Tube Refrigerator for Cryopump Applications

  • Lee, S.J.;Hong, Y.J.;Park, S.J.;Kim, H.B.;Kwon, S.B.
    • Progress in Superconductivity and Cryogenics
    • /
    • 제9권2호
    • /
    • pp.35-38
    • /
    • 2007
  • A single-stage and two-stage pulse tube refrigerators have been designed for cryopump application. The different diameters of pulse tube and regenerator have been investigated at single-stage pulse tube refrigerator(PTR). Experiments have been performed on single-stage PTR to reach minimum temperature with optimum valve opening at a few frequencies. And the two-stage pulse tube refrigerators have been assembled with tested single-stage pulse tube and tested. When orifice turn is opened to 9 and double inlet is opened to 3 at a single-stage, the lowest temperature of 33.7 K is achieved. The cooling capacity at single-stage is 38 W at temperature of 80 K. A two-stage pulse tube refrigerator has 16.3K at the second stage and 59.7K at the first stage. The cooling capacity achieved is 16.5 W at 80 K, the first stage and 0.6 W at 20 K, the second stage. Some details on the design of pulse tube refrigerator and the experimental apparatus are given.

A Study on the Energy Saving Type Pneumatic System Characteristics (에너지 절약형 공기압 시스템 특성에 관한 연구)

  • Kim, Hyeong-Ui;Kim, Dong-Su;Gang, Bo-Sik;Seong, Baek-Ju
    • 연구논문집
    • /
    • 통권25호
    • /
    • pp.91-98
    • /
    • 1995
  • Recently, improving the energy efficiency of a pneumatic system and reducing the consumption of compressed air were a concern of scholars at domestic and abroad. The using fields of a pneumatic system are widely used in factory automation of manufacturing line, chemical factories with explosiveness danger and petroleum industries etc. In particular, pneumatic cylinder is applied to feeding work of workpiece. jig tools and press mechanism, reciprocation and rotary motion with rack and pinion. In this study, the experimental apparatus consisted to pneumatic cylinder, dual supply pressure regulator and solenoid valve. The dual supply pressure regulator connected to outlet port of solenoid valve. The supply pressure($4.5kg_f/cm^2$) of compressed air goes into the rodless chamber 1 to drive the piston rod forward which is named working stage. The supply pressure ($2kg_f/cm^2$) of compressed air goes into the rod chamber 2 to drive the piston rod backward which is named no-working stage. Accordingly, the research results of this study can be obtained to Energy-Saving Effects of the compressed air about 35%.

  • PDF

The Development of the ±80kV 60MW HVDC System in Korea

  • Park, Kyoung-Ho;Baek, Seung-Taek;Chung, Yong-Ho;Jang, Gil-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.594-600
    • /
    • 2017
  • HVDC transmission systems can be configured in many ways to take into account cost, flexibility and operational requirements. [1] For long-distance transmission, HVDC systems may be less expensive and suffer lower electrical losses. For underwater power cables, HVDC avoids the heavy currents required to charge and discharge the cable capacitance of each cycle. For shorter distances, the higher cost of DC conversion equipment compared to an AC system may still be warranted, due to other benefits of direct current links. HVDC allows power transmission between unsynchronized AC transmission systems. Since the power flow through an HVDC link can be controlled independently of the phase angle between the source and the load, it can stabilize a network against disturbances due to rapid changes in power. HVDC also allows the transfer of power between grid systems running at different frequencies, such as 50 Hz and 60 Hz. This improves the stability and economy of each grid, by allowing the exchange of power between incompatible networks. This paper proposed to establish Korean HVDC technology through a cooperative agreement between KEPCO and LSIS in 2010. During the first stage (2012), a design of the ${\pm}80kV$ 60MW HVDC bipole system was created by both KEPCO and LSIS. The HVDC system was constructed and an operation test was completed in December 2012. During the second stage, the pole#2 system was fully replaced with components that LSIS had recently developed. LSIS also successfully completed the operation test. (2014.3)

Rediction of Stage Efficiency Variation of a USC High Pressure Steam Turbine by Computational Fluid Dynamics (유동해석을 이용한 고압증기터빈 단효율 변화 예측)

  • Kang, Soo Young;Jang, Hyuck Jun;Lee, Jeong Jin;Kim, Tong Seop;Park, Seong Jin;Hong, Gi Won
    • The KSFM Journal of Fluid Machinery
    • /
    • 제20권2호
    • /
    • pp.17-25
    • /
    • 2017
  • Prediction of performance and operating characteristics of a state-of-the-art ultra-supercritical (USC) steam turbine is an important issue in many ways. Theoretical and empirical correlation equations, developed a few decades ago, have been widely used in commercial programs for a prediction of performance. To improve of these correlation equations and apply them to the high pressure turbine of a USC steam turbine, computational fluid dynamic analysis was carried out and correlation equations to calculate efficiency variation of each stage were made. Both fluid dynamic characteristic and thermodynamic performance was analyzed for the development of the correlation equations. In particular, the impact of flow addition through an overload valve (OLV) between stages was examined throughly. The trend of pressure drop due to the flow mixing by the OLV flow addition was analyzed and an efficiency correlation equation considering the OLV flow was also made.

An Experimental Study on the Optimal Intermediate Pressure of a 2-Stage Compression Heat Pump Using River Water (하천수 열원 2단압축 열펌프의 최적 중간압에 관한 실험적 연구)

  • Park, Cha-Sik;Jung, Tae-Hun;Joo, Young-Ju;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제21권6호
    • /
    • pp.333-339
    • /
    • 2009
  • The objective of this study is to predict optimal intermediate pressure of a 2-stage compression heat pump system using river water. To determine the maximum performance of the 2-stage compression heat pump system, the experimental evaluations on the 2-stage compression cycle were carried out under various operating conditions. Electronic expansion valves were applied to control intermediate pressure and superheat. Based on the experimental data, an empirical correlation for predicting optimal intermediate pressure which considering cycle operating parameters was developed. The present correlation was verified by comparing the predicted data with the measured data. The predictions showed a good agreement with the measured data within a relative deviation of ${\pm}4%$ at various operating conditions.

Surgical Outcomes for Native Valve Endocarditis

  • Park, Bong Suk;Lee, Won Yong;Ra, Yong Joon;Lee, Hong Kyu;Gu, Byung Mo;Yang, Jun Tae
    • Journal of Chest Surgery
    • /
    • 제53권1호
    • /
    • pp.1-7
    • /
    • 2020
  • Background: The aim of this study was to evaluate the short-term and long-term results of surgical treatment for native valve endocarditis (NVE) and to investigate the risk factors associated with mortality. Methods: Data including patients' characteristics, operative findings, postoperative results, and survival indices were retrospectively obtained from Hallym University Sacred Heart Hospital. Results: A total of 29 patients underwent surgery for NVE (affecting the mitral valve in 20 patients and the aortic valve in 9) between 2003 and 2017. During the follow-up period (median, 46.9 months; interquartile range, 19.1-107.0 months), the 5-year survival rate was 77.2%. In logistic regression analysis, body mass index (p=0.031; odds ratio [OR], 0.574; 95% confidence interval [CI], 0.346-0.951), end-stage renal disease (ESRD) (p=0.026; OR, 24.0; 95% CI, 1.459-394.8), and urgent surgery (p=0.010; OR, 34.5; 95% CI, 2.353-505.7) were significantly associated with in-hospital mortality. Based on Cox proportional hazard regression analysis, the statistically significant predictors of long-term outcomes were hypertension, ESRD, and urgent surgery. Conclusion: Surgical treatment for NVE is associated with considerable mortality. The in-hospital mortality and 5-year survival rates of this study were 13.8% and 77.2%, respectively. Underlying conditions, including hypertension and ESRD, and urgent surgery were independent risk factors for unfavorable outcomes.

Design of closed-loop nitrogen Joule-Thomson refrigeration cycle for 67 K with sub-atmospheric device

  • Lee, C.;Lee, J.;Jeong, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • 제15권1호
    • /
    • pp.45-50
    • /
    • 2013
  • Closed-loop J-T (Joule-Thomson) refrigeration cycle is advantageous compared to common open loop $N_2$ decompression system in terms of nitrogen consumption. In this study, two closed-loop pure $N_2$ J-T refrigeration systems with sub-atmospheric device for cooling High Temperature Superconductor (HTS) power cable are investigated. J-T cooling systems include 2-stage compressor, 2-stage precooling cycle, J-T valve and a cold compressor or an auxiliary vacuum pump at the room temperature. The cold compressor and the vacuum pump are installed after the J-T valve to create sub-atmospheric condition. The temperature of 67 K is possible by lowering the pressure up to 24 kPa at the cold part. The optimized hydrocarbon mixed refrigerant (MR) J-T system is applied for precooling stage. The cold head of precooling MR J-T have the temperature from 120 K to 150 K. The various characteristics of cold compressor are invstigated and applied to design parameter of the cold compressor. The Carnot efficiency of cold compressor system is calculated as 16.7% and that of vacuum pump system as 16.4%. The efficiency difference between the cold compressor system and the vacuum pump system is due to difference of enthalpy change at cryogenic temperature, enthalpy change at room temperature and different work load at the pre-cooling cycle. The efficiency of neon-nitrogen MR J-T system is also presented for comparison with the sub-atmospheric devices. These systems have several pros and cons in comparison to typical MR J-T systems such as vacuum line maintainability, system's COP and etc. In this paper, the detailed design of the subcooled $N_2$ J-T systems are examined and some practical issues of the sub-atmospheric devices are discussed.

A Study on the Internal Flow Analysis of High-pressure Shut-off Valve for CNG Charging Station Piping System (CNG 충전소 배관시스템용 고압 차단밸브에 대한 내부 유동해석에 관한 연구)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • 제24권6_2호
    • /
    • pp.773-779
    • /
    • 2021
  • CNG, which has recently been attracting attention as an alternative fuel in the transportation field to reduce emissions caused by global warming, is natural gas with abundant reserves and mainly composed of methane. Being in a gaseous state, natural gas requires the compression and liquefaction processes for transportation. Until now, general shut-off valves for liquid and gas piping have been developed in Korea, but there are few studies on shut-off valves for high pressures of about 200 bar. Currently, research on the flow analysis of valves is being actively conducted around the world. However, there are relatively many studies on large valves such as low-pressure valves or shipbuilding and marine, and the safety factor through structural analysis to check the structural integrity of the valve is checked at the design stage. Since it is necessary to have a fast response speed while minimizing pressure and speed loss due to flow change, basic research was conducted on the flow analysis of the valve to secure design data, and the numerical analysis was performed on high-pressure automatic shut-off valves applied to CNG refueling stations. After securing the basic valve shape through reverse engineering for advanced products, we compared the valve flow coefficient Cv coefficient with advanced products. As a result, it was found that the reverse engineering model was at the level of about 60%. However, we compared the Cv coefficient by modifying the reverse engineering model, and the result showed that it was improved to about 96%.

An Analysis of the Effect of a Variant Drain Orifice Damping on an Electrohydraulic Servovalve Flapper-Nozzle Stage (전기유압 서보밸브 플랩퍼-노즐에 대한 변동 배유 오리피스의 영향 해석 1)

  • Lee, Jae-Cheon
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제16권2호통권95호
    • /
    • pp.50-59
    • /
    • 1999
  • The effect of a variant drain orifice damping on the characteristics of a servovalve flapper-nozzle stage is analyzed. Steady-state characteristics of flapper-nozzle stage and the linearized dynamics of flapper-nozzle assembly with a spool valve show that the variant drain orifice damping could improve such null performance characteristics as null pressure sensitivity and linearity of gain function. Generalized design criterion and a sufficient condition for servovalve stability are also established.

  • PDF