• Title/Summary/Keyword: 1st-order system

Search Result 420, Processing Time 0.025 seconds

Radiated Emission / Susceptibility Tests for the KSLV-I 2nd Stage Engineering Model (KSLV-I 2단부 엔지니어링 모델 복사성 방사/감응 시험)

  • Ji, Ki-Man;Lee, Soo-Jin;Chung, Eui-Seung
    • Aerospace Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.173-181
    • /
    • 2007
  • Radiated emission / susceptibility performance of the KSLV-I 2nd stage which are controlled from the unit level to the system level should be examined and managed all over the frequency ranges in order to ensure the normal operation of the SC, the 1st stage of the KSLV-I, ground support equipments which are installed at the space center, and other wireless communication networks. Not only unintentional electric field emissions from the KSLV-I system and its subsystems should be restricted to the levels less than the limits specified in the EMC requirements, but also proper test and evaluation method should be established, respectively. In this paper, radiated emission/susceptibility test limits, method, and test results of the KSLV-I 2nd stage engineering model are presented.

  • PDF

A comparative study for the decay of chlorine residual using EPANET2.0 and an experimental pipeline system (EPANET 2.0과 관망실험을 통한 배수관망 염소농도 감쇄 비교연구)

  • Baek, Dawon;Kim, Hyunjun;Kim, Sanghyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.5
    • /
    • pp.411-419
    • /
    • 2018
  • The residual chlorine concentration is an essential factor to secure reliable water quality in the water distribution systems. The chlorine concentration decays along the pipeline system and the main processes of the reaction can be divided into the bulk decay and the wall decay mechanisms. Using EPANET 2.0, it is possible to predict the chlorine decay through bulk decay and wall decay based on the pipeline geometry and the hydraulic analysis of the water distribution system. In this study, we tried to verify the predictability of EPANET 2.0 using data collected from experimental practices. We performed chlorine concentration measurement according to various Reynolds numbers in a pilot-scale water distribution system. The chlorine concentration was predicted using both bulk decay model and wall decay model. As a result of the comparison between experimental data and simulated data, the performance of the limited $1^{st}$-order model was found to the best in the bulk decay model. The wall decay model simulated the initial decay well, but the overall chlorine decay cannot be properly predicted. Simulation also indicated that as the Reynolds number increased, the impact of the wall.

A Study on the Flow Characteristics for the Plate Chamber in Type of Oily Parallel Plate Water Separator (평행판식 유수분리기에서 분리판실의 유동특성에 관한 연구)

  • Kim, J.H.;Han, W.H.
    • Journal of Power System Engineering
    • /
    • v.5 no.1
    • /
    • pp.64-72
    • /
    • 2001
  • According to the regulation of IMO, oil discharge from ships is allowed under 15ppm only and an oil filtering equipment is essential. However, for large ships using heavy fuel oil of over S.G 0.98 and viscosity 380cSt and system oil, it has been in difficulty to process with existing filtering type of oily water separator. A parallel plate type oily water separator which is one of gravity type separators can be used as an assistant equipment for the oil filtering system to meet the present IMO standard of 15 ppm, because it is an efficient method in dealing with a large amount of rich oil with high specific gravity. This work is focused on the fundamental investigation of the performance of the plate type oily water separator by visualization method and PIV(Particle Image Velocimetry) measurement to acquire multi-point velocity data simultaneously. The experimental results showed that the space of the plates acts a significant role in separating process and it was found that an important point to minimize a vortex flow is to flow a large amount of fluid in space of the plates in order to promote the efficiency of separation.

  • PDF

A study on Fairing System for Traveling Noise Reduction in Urban Subway (도시철도 운행소음 저감용 훼어링시스템 연구)

  • Choi, Sang-Chun;Jang, Won-Rak;Ho, Kyoung-Chan
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.659-666
    • /
    • 2009
  • As the density and height of the buildings nearby subway lines get higher, the unprecedented residents' appeals for noise are on the rise. Furthermore, in accordance with the revision of enforcement regulations on the Noise and Vibration Control Act, the night time noise standards have been reinforced by 5dB effective on January 1st 2010 and the appropriate measures shall be taken accordingly. For the settlement of the public grievances against noise and vibration generated on tracks in at-grade and elevated section, the installation of continuously-welded-rail, rail lubrication system, improved fastening system and higher noise barrier is currently executed. Nevertheless, the noise and vibration levels in some areas are still exceeding the limits required in the regulation. Among the measures, an installation of higher noise barrier or noise tunnel seems to be the most effective way; however, it has limitations owing to the structural stability of existing elevated structures. The paper in consideration of the local conditions and foreign practices discusses the installation of fairing system under the train body as an noise insulation panel in order to reduce the rolling noise and under-carriage noise. Based on the result of this study, a performance verification test during actual train operation is in progress for further study.

  • PDF

A study of the enhanced ATM cell transmission in satellite communication system using variable-size block interleaving (위성망에서 가변블록 인터리빙 기법을 이용한 ATM 셀 전송 성능향상에 관한 연구)

  • 김은경;김낙명
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.5
    • /
    • pp.1-10
    • /
    • 1998
  • Satellite communication is getting more important in the coming 21st century because of its wide areas sevice capability, ease of access, and fast channel establishment. As such, satellite communication networks will be the basis of the global communication system in cooperation with the ground ATM networks. In this paper, we consider an efficient transmission methodology of ATM cells over the satellite communication channel. We first analyze possible bottlenecks and performance deterioration factors in the case, and then propose an enhanced cell trasmission mechanism. In order to use satellite channel for ATM cell transmission, the application of complicated channel coding is inevitable. However, the forwared error control such as convolutional encoding brings forth burst errors, which calls for the application of some kind of interleaving mechanism to randomize the burst errors at the receiver. Another aspect which should b econsidered in satellite communication system is the inherent transmission delay, which can be very considered in satellite communication system is te inherent transmission delay, which can be very critical to the delay-sensitive ATM traffic. Therefore, we propose that the processing delay at the block interleaving stage should be controlled propose a variable-size block interleaving mechanism which utilizes the predicted transmission delay for each traffic in the queues of the transmitter. According to the computer simulation, the proposed mechanism could improve the overall performance by drastically reducing the ATM cell drop rate owing to the excessive transmission delay.

  • PDF

The Characteristics of the Dehydration Reaction and the Durability for the Thermal Decomposition in Na2B4O7·10H2O/Na2B4O7·5H2O System (Na2B4O7·10H2O/Na2B4O7·5H2O 계의 열분해 탈수반응 및 내구성 고찰)

  • Choi, Ho-Sang;Park, Young-Tae
    • Applied Chemistry for Engineering
    • /
    • v.10 no.6
    • /
    • pp.885-888
    • /
    • 1999
  • This study was carried out to determine the reaction kinetic constant of the dehydration - thermal decomposition of $Na_2B_4O_7{\cdot}10H_2O/Na_2B_4O_7{\cdot}5H_2O$ and to investigate the durability during the repeated use of a chemical heat-storage material and the reproducibility of reaction system. The order of the dehydration reaction was 1st-order. The reaction rate was directly proportional to a partial pressure difference of water steam. The kinetic constant was 0.27 and the reproducibility of dehydration reaction for a kinetic constant and a reaction order was excellent. The activity variation in the durability test of a chemical heat-storage material was within range of ${\pm}5%$ during the repeatedly use in several times.

  • PDF

Responses of Growth and Yield by Plants Number in High Ridge Hill Seeding on Sorghum(Sorghum bicolor (L.) Moench) (수수의 고휴점파 본수에 따른 생육특성과 수량 변화)

  • Jeon, Seung-Ho;Cho, Young-Son;Jung, Ki-Youl
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.59 no.3
    • /
    • pp.307-311
    • /
    • 2014
  • This study was conducted to evaluate effect of plants number per hill (PNH) on growth and yield of sorghum in drained paddy field for 2 years. Crop growth and development and yield in the field was examined to know the efficiency of proposed cropping system. At seeding after 40 days, leaf number and stem diameter were highest at 1 PNH plot, on the other hands, plant height was at 5 PNH plot the $1^{st}$ and $2^{nd}$, respectively. The harvest stage, 5 PNH plot was highest culm length of 183, 188 cm the $1^{st}$ and $2^{nd}$, however, culm diameter was lowest. Culm length of sorghum was highest by 183, 188 cm at 5 PNH plot also, culm diameter was thickest by 19.18, 20.13 mm at 1 PNH, respectively. Yield components of ear length, seed number per ear and 1000-seed weight were highest at 1 PNH the $1^{st}$ and $2^{nd}$, respectively. As yield of sorghum was highest at 2 PNH plot $344kg{\cdot}10a^{-1}$, $382kg{\cdot}10a^{-1}$ yearly, respectively that it were in order of 1 PNH plot > 3 PNH plot > 4 PNH plot > 5 PNH plot.

Experimental Study on Corrosion Characteristics of 1.25Cr-0.5Mo in the 1st-mathanator reactor for Synthetic Natural Gas according to Gas Compositions (1.25Cr-0.5Mo강을 이용한 합성가스 조성 변화에 따른 SNG 1차반응기의 부식특성에 관한 실험적 연구)

  • Kim, Jin-Hyun;Cho, Honghyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.709-716
    • /
    • 2016
  • Recently, the operating conditions of the various mechanical structures have become more severe and the running time has become longer as the development of plant equipment increases with the introduction of high technology. Thus, the reliability of the system and its accessories is becoming a problem. Normally, synthetic natural gas (SNG) plants use 1.25Cr-0.5Mo or 2.25Cr-1Mo heat resistant steel according to the operating conditions. In this study, a lab-scale reactor was set up using 1.25Cr-0.5Mo steel, in order to carry out corrosion tests for producing synthetic natural gas. The corrosive characteristics were investigated under 1st-methanator operating conditions and fundamental data about the durability and reliability were obtained by using the experimental test. The analysis of results obtained on the durability of the reactor under emission and injection compositions showed that the hydrogen embrittlement caused by hydrogen and the oxidation corrosion caused by H2O had the most effect on the durability of 1.25Cr-0.5Mo steel in the SNG reactor. However, the hydrogen embrittlement and oxidation corrosion occurred simultaneously under emission conditions, so that the corrosion of the material increased suddenly after a long operating time. Besides, the corrosion of the 1.25Cr-0.5Mo steel under the injection composition was faster than that under the emission composition.

Efficient Establishment of Protected Areas in Pyoungchang County, Kangwon Province to Support Spatial Decision Making (강원도 평창지역의 보호지역 확대를 위한 공간의사결정 지원방안)

  • Mo, Yongwon;Lee, Dong-Kun;Kim, Hogul;Baek, Gyounghye;Nam, Sangjun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.16 no.1
    • /
    • pp.171-180
    • /
    • 2013
  • As the second-largest 1st degree of ecological zone in Kangwon Province, Pyeongchang County is expected to play an important role in expanding the protected areas of the Republic of Korea. However, Pyoungchang County is expected to experience an increase in demand for development due to the 2018 Winter Olympics. Problems related to various stakeholders and limited budget will arise regarding the issue of expanding the protected areas. In this study, in order to effectively control these problems, we designed expansion plans for the 1st degree ecological zoning map areas and the observed data of threatened species I and II in Pyoungchang County by using the MARXAN Software. As for the methods, we first set the planning units(PUs) for the spatial analysis. The PUs include boundary length, land cost, land status, etc. Then, we made the input data by controlling the conservation features, BLM(Boundary Length Modifier) and iteration numbers. There are two measures for the establishment of the protected areas, one of which only concerns with the ecological priority, and the other with combining the land cost on forest. The one illustrated shows that the larger patches that include the conservation feature was selected as a candidate of the protected areas. The other one presented shows that inexpensive land cost areas were selected. As this study produces visual results and enables an efficient application of various values in selecting protected areas, we believe that it will be useful to various stakeholders in spatial decision-making process.

A STUDY ON THE ANALYSIS OF OCCLUSAL CURVE OF THE NORMAL SUBJECTS (정상인의 교합 만곡 분석에 관한 연구)

  • Choi, Myung-Sik;Kay, Kee-Sung;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.95-122
    • /
    • 1990
  • This study was done to analyze the occlusal curve as one of the factors to be considered for maintenance of occlusal stability in the orthodontic and prosthodontic treatments. Sixty gnathological casts we.e obtained from 43 subjects with normal occlusion and 17 subjects with some of temporomandibular disorders. The occlusal surfaces of gnathologic casts were duplicated by using a Color kit SK-700 and tile reference points of X, Y coordinates were digitized by using the Summagraphic digitizer and 18AT computer system. The Z coordinates of cusp height were measured by 0.01mm measurable caliper. The mathematical computer program of least square method was used to analyze the occlusal curve arranged by three dimensional coordinates of X, Y, Z. The following results were obtained : 1. The occlusal curve of buccal and lingual cusp tips was fitted to the ellipse, and the occlusal curve of anterior teeth was fitted to a part of the circle in the analysis of conic sections. 2. The radius of Spee's curve showed individual differences, but was average 98.7mm in male subjects and 93.7mm in female subjects. 3. The radius fo Spee's curve according to the half of canine width showed the least coefficient of variation. 4. The radius of Spee's curve was not significantly relative to the lateral occlusal contacts on laterotrusion and the absence or presence of temporomandibular disorders. 5. The radius of Wilson's curve showed individual difference and the size of radius was followed by the order of 1st premolar, 2nd premolar, 2nd molar and 1st molar.

  • PDF