• Title/Summary/Keyword: 1kW급

Search Result 383, Processing Time 0.028 seconds

Design of 1.5kW PCS Using Interleaved Full-Bridge Converter and Single Phase Half-Bridge Inverter (인터리브드 풀 브릿지 컨버터와 단상 하프 브릿지 인버터를 이용한 1.5kW급 PCS 설계)

  • Na, Kwang-Su;Na, Jong-Kuk;Lee, Hee-Jun;Shin, Soo-Cheol;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.403-404
    • /
    • 2013
  • In this paper, a PCS which consists of high boost interleaved full-bridge converter and single phase half-bridge inverter is proposed. Proposed PCS is using two full bridge converter modules. PCS consists of parallel input / serial output. It can reduce turn ratio of high frequency transformer. In this paper, PCS which is using 1.5[kW] interleaved full-bridge converter and single phase half bridge inverter is designed and verified stability of system through experiment.

  • PDF

1.5kW Power converter of Stand alone Fuel cell hybrid System. (1.5kW급 독립형 연료전지 하이브리드시스템 전력변환장치)

  • Shin, Min-Ho;Jung, Doo-Yong;Park, Se-Rin;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.20-21
    • /
    • 2011
  • 본 논문은 1.5[kW]급 독립형 연료전지 하이브리드 시스템의 고효율 전력변환장치에 관한 연구이다. 응답속도가 느린 연료전지 시스템의 안정도를 높이기 위하여 2차 전지를 이용한 하이브리드 시스템으로 구성되었으며, 낮은 출력 전압과 높은 출력 전류의 고효율 컨버터를 구현하기 위하여 입력컨버터는 동기정류 방식의 부스트컨버터와 출력컨버터는 병렬 인터리빙 방식으로 구현하였고, 동작특성 및 효율성을 실험을 통해 증명하였다.

  • PDF

1kW class DC power supply by parallel operation of the flyback converter (Flyback Converter를 병렬운전한 1kW급 직류전원)

  • Kim, Sung-Chul;Lee, Gi-Sun;Nho, Jun-Tak;Ko, In-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2252-2254
    • /
    • 1997
  • There are increasing demands on high accruacy DC power supplies for varous basic science reseach, such as accelerators and plasma applications, in Korea. In this paper, we present a study on 1kW class DC power supply using the parell operation method of the flyback converters. This DC power supply is equipped with a remote controller for computer interface. A Serial Communication Controller(SCC) is also developed for large scale scientific facilities which is capable of handling upto 32 power supplies simultaneously with one serial port in the host computer.

  • PDF

Design and Flow Analysis on the 1kW Class Horizontal Axis Wind Turbine Rotor Blade for Use in Southwest Islands Region (서남권 도서지역에 적합한 1kW급 수평축 풍력터빈 로터 블레이드 설계 및 유동해석)

  • Lee, Jun-Yong;Choi, Nak-Joon;Yoon, Han-Yong;Cho, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.3
    • /
    • pp.5-11
    • /
    • 2012
  • This study is to develop a 1kW-class horizontal axis wind turbine(HAWT) rotor blade which will be applicable to relatively low wind speed regions in southwest islands in Korea. Shape design of 1kW-class small wind turbine rotor blade is carried out using a blade profile with relatively high lift to drag ratio by blade element momentum theory(BEMT). Aerodynamic analysis on the newly designed rotor blade is performed with the variation of tip speed ratio. Power coefficient and pressure coefficient of the designed rotor blade are investigated according to tip speed ratio.

Flow Analysis on a 1kW-class Horizontal Axis Wind Turbine Blade for Hybrid Power Generation System (복합발전 적용을 위한 1kW급 수평축 풍력터빈 유동해석)

  • Lee, Jun-Yong;Choi, Nak-Joon;Choi, Young-Do
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.60.2-60.2
    • /
    • 2011
  • This study is to develop a 1kW-class small wind turbine blade which will be applicable to relatively low speed regions. For this blade, a high efficiency wind turbine blade is designed and a light and low cost composite structure blade is adopted considering fatigue life. In this study, shape design of 1kW-class small wind turbine blade for hybrid power generation system is carried out by BEMT(blade element momentum theory). X-FOIL open software was used to acquire lift and drag coefficients of the 2D airfoils used in power prediction procedure. Moreover, pressure and velocity distributions are investigated according to TSR by CFD analysis.

  • PDF

A Thermal Analysis of 1 kW Hydrogen Linear Generator (1kW급 수소리니어 발전기 열해석)

  • Yang, Si-Won;Lee, Jae-Sung;Kweon, Ki-Yeong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.29-32
    • /
    • 2006
  • Recently, many researches of the alternative and renewable energy have introduced due to the increasing oil price, the limited natural resources and the environmental pollution. In case of hydrogen energy, it has some merits, which can be substituted the existing the fossil fuel because of no contaminants from the combustion and the chemical reaction. We have been developing 1kW Hydrogen Linear Generator. In this paper, the thermal characteristic of this prototype linear generator has been investigated and obtained reliable analysis results comparing with experimental measurements. Especially, it is predicted that in case of 1kW, 60Hz test sample, the results satisfy with the temperature standards of H type insulation, which is shown average $69.0^{\circ}C$ temperature distribution at the coil.

  • PDF

Development of Independent 1 kW-class PEMFC-Battery Hybrid System for a Building (건물용 독립형 1kW급 PEMFC-배터리 하이브리드 시스템 기술 개발)

  • Yang, Seug Ran;Kim, Jung Suk;Choi, Mi Hwa
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.2
    • /
    • pp.113-120
    • /
    • 2019
  • We have developed 1 kW-class PEMFC-battery hybrid system independently powering to the building, through the process of system design, current load characteristics analysis, power system configuration for demonstration site and performance evaluation. In order to use the fuel cell and battery as the hybrid type, a control technology for the charging/discharging decision and charging speed of the battery is required rather than using fuel cell. Also output power distribution between PEMFC and the battery is a core of energy management technology. It is confirmed that it is possible to supply independently 1kW powering the building to ensure optimal energy management through the power control experiment of the hybrid system.

An Evaluation of Strength of 1kW Blade according to the change in Hybrid composit meterials (하이브리드복합소재 적층방법에 따른 1kW 블레이드의 강도평가)

  • Lee, Kang-Il;Lee, Kil-Sung;Sun, Min-Young;So, Byung-Wuk;Lim, Jae-Kyoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.41.1-41.1
    • /
    • 2011
  • 풍력블레이드는 가벼워야 하며 강도면에서 신뢰성이 확보되어야한다. 최근 들어 복합소재를 적용한 블레이드가 많이 선보이고 있다. 현재 가장 많이 사용되는 유리섬유/에폭시는 경제성 및 강도면에서 우수하여 많이 사용되어왔다. 본 논문에서는 유리섬유(80%)-탄소섬유(20%)/에폭시를 사용하여 강도를 높이고 무게를 경감시켜 효율을 증가시키고자 연구하였다. 국내 풍황에 적합한 1kW급 풍력블레이드의 Airfoil을 개발하여 강도를 평가하고 블레이드를 최적화 설계하였다. 유리섬유(80%)-탄소섬유(20%)가 적용된 복합재를 적층방법에 따라 실험하고 이를 블레이드 강도평가에 적용하였으며 FSI (Fluid-Structure Interaction)를 사용하였다. 이를 통해 블레이드의 무게경감 및 강도가 향상되었다.

  • PDF

Dynamic Response Measurements and Analysis on a 10 kW Class Vertical Axis Wind Turbine (10 kW급 수직축 풍력터빈에 대한 구조물 동적응답 계측 및 분석)

  • Yi, Jin-Hak;Kim, Wonsul;Han, Taek Hee;Yim, Sungyul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.1
    • /
    • pp.107-113
    • /
    • 2017
  • The dynamic characteristics including natural frequencies and excitation frequencies are evaluated for a small 10 kW vertical axis wind turbine. Acceleration responses were measured at 12 distributed locations for impact vibration tests, ambient vibration tests during non-operational and operational conditions, and braking tests during operational condition. The natural frequencies for the lowest 2 bending modes and the first torsional mode were estimated and also the excitation frequencies, i.e. 1P, 2P, 4P, were also estimated according to the rotational speed using the responses under operational conditions (i.e. power generation condition).

A Study of the Fiber Fuse in Single-mode 2-kW-class High-power Fiber Amplifiers (단일 모드 2 kW급 고출력 광섬유 증폭기 내의 광섬유 용융 현상에 관한 연구)

  • Lee, Junsu;Lee, Kwang Hyun;Jeong, Hwanseong;Kim, Dong Jun;Lee, Jung Hwan;Jo, Minsik
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.1
    • /
    • pp.7-12
    • /
    • 2020
  • In this paper, we experimentally investigate the fiber fuse in single-mode 2-kW-class high-power fiber amplifiers, depending on the cooling method at the splicing point. We measured the temperature of the splicing point between the pump-signal combiner and gain fiber as a function of laser output power. The temperature of the splicing point increased from 20 to 32℃ with a slope of 0.01℃/W, up to 1.2 kW of laser output power. At higher powers the temperature of the splicing point increased dramatically, with a slope of 0.08℃/W. After that, the fiber amplifier was destroyed during operation at 1.96 kW of output power by fiber fuse. The bullet shape, a common feature of fiber fuse, was observed in the damaged passive fiber core of the pump-signal combiner. Later, we adopted an improved water-cooled cold plate to increase the cooling efficiency at the splicing point, and investigated the laser output power. The temperature at the splicing point was 35.8℃ with a temperature-rise slope of 0.007℃/W at the maximum output power of 2.05 kW. The beam quality M2 was measured to be less than 1.3, and the output beam's profile was a stable Gaussian shape. Finally, neither fiber fuse nor mode instability was observed in the fiber amplifier at the maximum output power of 2.05 kW.