• Title/Summary/Keyword: 1G wire

Search Result 121, Processing Time 0.031 seconds

Characteristics of AC loss of Hybrid Multi-Stacking with HTS Wires in External Magnetic Field (고온초전도 혼합적층선재의 외부자장 변화에 따른 손실 특설)

  • Lim, Hyoung-Woo;Lee, Dong-Min;Yun, Ki-Hyun;Cha, Guee-Soo;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.71-73
    • /
    • 2006
  • AC loss on variation of external magnetic field is a very important factor in development of power applications. In this paper, we measured and compared AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires and uniform-multi-stacked wire made of one type of wires, 1G wires or 2G wires. Measurement was performed using by the linked-picked coil method. As results, as the number of wires increase, AC loss per unit volume of both stacked wires in low external magnetic field is reduced. Also AC loss of 2G slacked wire is higher than that of 1G wire. AC loss per unit length of 2G stacked wire is less than that of 1G stacked wire. And AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires was between uniform-multi-stacked wire made of 1G wires and 2G wires.

  • PDF

Estimation of Magnetization loss of HTS wires with Different Current Density (전류 밀도가 다른 선재들의 자화손실 특성 평가)

  • Lim, H.;Yoon, K.;Lee, H.;Cha, G.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.72-75
    • /
    • 2007
  • Magnetization loss of HTS wire is strongly dependent on the critical current density and the aspect ration of the HTS wire. This paper presents the magnetization loss of stacked BSCCO wire and stacked YBCO wires which had different critical current densities. Width of the BSCCO wire was 4mm and widths of two YBCO wires were 4mm and 8mm. Single wire, two stacked three stacked and four stacked wires were fabricated and tested. Ratio of magnetization loss of BSCCO wire to YBCO wire was presented at single wire. For stacked wire, ratio of magnetization loss of single wire to stacked wire was presented. Test results shows that magnetization losses of stacked wires were greater than that of single wire at large high magnetic field above critical magnetic field.

Magnetization loss of Hybrid Multi-Stacked wire made of 1G wires and 2G wires (1세대 선재와 2세대 선재의 혼합 적층에 따른 자화손실 특성)

  • Lim, H.;Lee, Y.;Lee, H.;Cha, G.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.57-60
    • /
    • 2007
  • Superconducting electric power devices need to stack HTS wires to increase the current carrying capacity. Uniform multi-stacked wires(UMS) which were made of the same HTS wires have been used. This paper shows the magnetization loss of hybrid multi-stacked(HMS) wire made of BSCCO wires and YBCO wires. Five HMS wires, YB(YBCO-BSCCO), YYBB. YBYB, YBBY and BYYB, were made and tested. Magnetization losses of each UMS wire were compared with corresponding HMS wire. Test results show that magnetization losses per unit length of HMS wire are between the corresponding UMS BSCCO wire and HMS YBCO wire below critical magnetic field. Above the critical magnetic field, magnetization losses of HMS wires are larger than that of corresponding both VMS wires.

Development of 220kV 1C*2000SQ Slip-on Type EB-G Ass'y (220kV 1C*2000SQ Slip-on Type EB-G 접속재 개발)

  • Kim, Young-Tek;Kim, Hyun-Ju;Kim, Han-Hwa;Park, Jeong-Ki;Kim, Duk-Hwan;Lee, Kang-Mi
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1612-1613
    • /
    • 2011
  • 초고압 XLPE 케이블용 접속재는 고도의 신뢰성과 안정성이 요구되며, 국내외적으로 제품 경량화, 시공 공정 단순화 등 고객의 다양한 요구가 점차 증가하는 추세이다. 당사는 220kV 1C${\times}$2000SQ XLPE 케이블 접속재인 EB-G(가스중 종단접속함)를 Slip-on Type으로 적용함으로써 고객의 요구에 맞춰 단순한 내부절연구조에서 비롯되는 전기적 특성의 안정성과 신속한 시공성을 확보하게 되었다. 본고에서는 220kV급 접속재인 가스중종단접속함(EB-G)의 설계, 개발시험에 관하여 소개하고자 한다.

  • PDF

A clean technology development using the iron(Fe) dissolution reaction with hydrogen peroxide (과산화수소를 이용한 철(Fe)선 용해반응에 따른 청정기술 개발에 관한 연구)

  • 김재우
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.4
    • /
    • pp.62-68
    • /
    • 2001
  • The advantages of hydrogen peroxide dissolution method were no discharge of noxious matter when dissolution of iron wire which used as the center supporter, reactions occur in room temperature and easy to recover dissolved iron. This study was aimed at gathering the basic data of iron wire dissolution- recovery process and proposes the reaction condition of iron wire dissolution- recovery process rind the factors influencing those reactions. The results were as follows : 1 . Hydrogen peroxide dissolution method used hydrochloric acid as the catalyst. 1. In the dissolution of iron wire(1.668 g), the condition of reaction was E1702(30 ml), HCI(20 ml) and $H_2O$(200 ml) ; time of the reaction was 18 min. P.W.(Piece weight) was 7.75 mg, and C.R. was $2.34{\;}{\Omega}$ 2. In the dissolution of iron wire(1.529 g), the condition of reaction was H7O2(30 ml), HCI(20 ml) and $H_2O$(200 ml), time of the reaction was 21 min., P.W.(Piece weight) was 7.73 mg, and C.R. was $2.35{\;}{\Omega}$. Hydrogen peroxide dissolution method used sulfuric acid as the catalyst. 1. In the dissolution of iron wire(0.834 g), the condition of reaction was $H_2O$(65 ml), $H_2SO_4$(5 ml) and 1702(5 ml) ; time of the reaction was 5 min.30 sec, P.W.(Piece weight) was 7.74 mg, and C.R. was $2.33{\;}{\Omega}$ 2. In the dissolution of iron wire(1.112 g), the condition of reaction was $H_2O$(65 ml), $H_2SO_4$(5 ml) and $H_2O_2$(5 ml) ; time of the reaction was 4 min.30 sec, P.W.(Piece weight) was 7.75 mg, and C.R. was $2.33{\;}{\Omega}$. Hydrogen peroxide dissolution method used hydrochloric acid and sulfuric acid as the catalyst confirmed a clean technology, because there were not occurred a pollutant discharged in the existing method.

  • PDF

An experimental study on diameter increase of orthodontic wire by electroplating (전기도금을 이용한 스테인레스 스틸 선재의 직경 증가에 관한 실험적 연구)

  • Cho, Jin-Hyoung;Sung, Young-Eun;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.33 no.2 s.97
    • /
    • pp.121-130
    • /
    • 2003
  • The purpose of this study was to evaluate the possibile clinical application of electroplating to increase diameter of an orthodontic wire, through examining the change of physical properties. The diameter of stainless steel orthodontic wire was increased from 0.016 inch to 0.018 inch by electroplating in a bath of nickel sulfate 100g/L, nickel chloride 60g/L, boric acid 30g/L, and sodium chloride 50g/L, under the conditions of 1.7V, $25\~29^{\circ}C\;and\;3.1\~3.3pH$. During the electroplating, the rate of diameter increase was measured every minute. To investigate uniformity, the diameter was measured at three different locations of each wire specimen aster electroplating. An X-ray diffraction test was performed to analyze the nature of the electroplated metal. Following heat treatment to improve adhesion between the wire and electroplated metal, a three-point bending test was conducted to compare stiffness, field strength, and ultimate strength among four wire groups; 0.016 inch, electroplated 016, electroplated and heat-treated 016, and 0.018 inch wires. Through the comparison of each wire group, following results were obtained. 1. In the load-deflection graph, the curve of the electroplated group was Placed between that of the 0.016 inch group and the 0.018 inch group, and the owe was closer to the 0.018 inch group by heat treatment. 2. In the electroplated and heat-treated 016 wire group, the values of stiffness, yield strength and ultimate strength showed higher tendency than in the original 0.016 Inch group. Stiffness and ultimate strength showed statistically significant differences between two groups. 3. Stiffness, yield strength, and ultimate strength of electroplated wire presented lower values than those of 0.018 inch wire group. 4. Stiffness, yield strength, and ultimate strength of electroplated and heat-treated wire showed higher tendency than those of electroplated wire group, and ultimate strength showed statistically significant difference between two groups. 5. After electroplating, the difference in diameter between the three locations was within $0.1\~0.3\%$ variation, and showed no statistical significance.

Development of Accessories for 345kV XLPE Cable with Small Size Conductor (345kV XLPE 소도체 Cable용 접속함의 개발)

  • Kim, H.J;Kim, K.Y;Park, J.K.;Song, J.H.;Shin, H.D.;Park, K.L.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1775-1777
    • /
    • 2004
  • Taihan Electric Wire Co. developed accessories(PJ, EB-G, EB-A, EB-O) for 345kV XLPE $1C{\times}600mm^2$ cable as a small size conductor cable, after installed 345kV XLPE $1C{\times}600mm^2$ cable, PJ and EB-G on Youngseo${\sim}$Youngdeungpo project KEPCO planed in 2003. All of 345kV XLPE $1C{\times}600mm^2$ cable Accessories are finished the type tests successfully. Straight joint as a Prefabricated Joint(PJ) had shorter the days of assembling than those of TMJ used on the 154kV XLPE Cable. Particularly, the use of clean booth to prevent the dusts and the penetration of water also had made the quality of jointing improved.

  • PDF

Improvement on resolution of mono-filament wire (초음파 팬텀 내 모노필라멘트의 해상력 개선에 대한 연구)

  • Ma, Sang-Chull;Kong, Young-Kun
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.49-56
    • /
    • 2003
  • The purposes of this study are to improve the ultrasound resolution of various nylon and metallic mono-filament wires, therefore, it was tested that it analyze on nylon mono-filament wire of 0.1 mm in A Co.'s ultrasonic phantom and synthesis of C15 g tissue mimicking materials(TMM), analyze resolution of nylon and metallic mono-filament wires in water and TMM. The results obtained were summarized as follows: 1. Metallic mono-filament wire of 0.1 mm and nylon mono-filament wire of 0.12 mm, 180 denier showed that it cleared dot echo pattern. 2. Metallic and nylon mono-filament wire of 0.2 mm showed that it cleared comet tail echo by reverberation artifact. 3. Nylon and metallic mono-filament wire of 0.1 mm showed that it can used for dead zone and axial resolution test. 4. Nylon mono-filament wire compared with metallic mono-filament wire showed that it satisfy elasticity and construction. 5. Degree of hardness of na not changed mono-filament's echo textures.

  • PDF

Drag Characteristics According to Ground Rope and Seabeds in the Bottom Trawl (저층트롤의 발줄 및 저질의 종류에 따른 저항특성)

  • 신정욱;이주희;권병국
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.1
    • /
    • pp.58-68
    • /
    • 2002
  • The model experiments for the Eastern sea bottom trawl were conducted for the 3 types of ground ropes and 2 types of seabeds to examine drag characteristics according to towing speed. The model net was based on the net of trawler with 750ps and made by 1/78 of a full scale net. This experiments focused on the drags for 3 types of ground rope, the serving wire, the original and the chain types and 2 types of seabeds, mud and sand of bottom. The results obtained are summarized as follows 1. In the case of the sand bottom, the drags by 3 types of ground rope were orderly increased in turn of the chain, the serving wire and the original type. But, in the case of the mud bottom, the drag of the original type is higher than that of the serving wire type and less than the chain type. 2. In the case of the serving wire type of ground rope, the drags by the diameters of ground rope, ø 1.3, ø 1.9, ø 2.6 and ø 3.25 were increased respectively by 23g, 25g, 32g and 42g at the towing speed of 0.4m/s. 3. The drags of ground ropes were increased exponentially in proportion to the towing speed, in the same way in all of three types of ground rope. 4. The ratios of drag of ground rope against that of the trawl net by the type of ground rope at the towing speed of 0.4m/s on the mud bottom were 0.69 in the chain type, 0.64 in the serving wire type and 0.67 in the original type respectively. 5. The Coefficient of drag($C_d$) by type of ground rope according to the towing speed were 10.0~56.7, 3.0~l6.0 and 1.5~8.5 respectively in turn of the chain type, the serving wire type and the original type on the mud bottom, and that on the sand bottom were 10.0~60.0, 3.0~14.0 and 1.2~6.0 respectively In turn of the chain type, the serving wire type and the original type.

Characteristic of Transport Current loss case of composition multi stacked with BSCCO wire and YBCO wire (1세대 선재와 2세대 선재의 혼합 적층시 발생하는 전송전류 손실 특성)

  • Lim, Hyoung-Woo;Cha, Guee-Soo;Lee, Ji-Kwang;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.845-846
    • /
    • 2006
  • Reduce AC loss is very important in superconductor power machine. And HTS power application are needed an increment of current capacity. in this paper estimate AC loss effect and increase of current according tocomposition stack with 1G wire and 2G wire by measurement. A Method of composition stack are YBCO-BSCCO, YBCO-BSCCO-BSCCO-YBCO and BSCCO-YBCO-YBCO-BSCCO. also, test result compared analytic equation by Norries

  • PDF