• Title/Summary/Keyword: 154

Search Result 7,010, Processing Time 0.037 seconds

Highly Doped Nano-crystal Embedded Polymorphous Silicon Thin Film Deposited by Using Neutral Beam Assisted CVD at Room Temperature

  • Jang, Jin-Nyeong;Lee, Dong-Hyeok;So, Hyeon-Uk;Hong, Mun-Pyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.154-155
    • /
    • 2012
  • The promise of nano-crystalites (nc) as a technological material, for applications including display backplane, and solar cells, may ultimately depend on tailoring their behavior through doping and crystallinity. Impurities can strongly modify electronic and optical properties of bulk and nc semiconductors. Highly doped dopant also effect structural properties (both grain size, crystal fraction) of nc-Si thin film. As discussed in several literatures, P atoms or radicals have the tendency to reside on the surface of nc. The P-radical segregation on the nano-grain surfaces that called self-purification may reduce the possibility of new nucleation because of the five-coordination of P. In addition, the P doping levels of ${\sim}2{\times}10^{21}\;at/cm^3$ is the solubility limitation of P in Si; the solubility of nc thin film should be smaller. Therefore, the non-activated P tends to segregate on the grain boundaries and the surface of nc. These mechanisms could prevent new nucleation on the existing grain surface. Therefore, most researches shown that highly doped nc-thin film by using conventional PECVD deposition system tended to have low crystallinity, where the formation energy of nucleation should be higher than the nc surface in the intrinsic materials. If the deposition technology that can make highly doped and simultaneously highly crystallized nc at low temperature, it can lead processes of next generation flexible devices. Recently, we are developing a novel CVD technology with a neutral particle beam (NPB) source, named as neutral beam assisted CVD (NBaCVD), which controls the energy of incident neutral particles in the range of 1~300eV in order to enhance the atomic activation and crystalline of thin films at low temperatures. During the formation of the nc-/pm-Si thin films by the NBaCVD with various process conditions, NPB energy directly controlled by the reflector bias and effectively increased crystal fraction (~80%) by uniformly distributed nc grains with 3~10 nm size. In the case of phosphorous doped Si thin films, the doping efficiency also increased as increasing the reflector bias (i.e. increasing NPB energy). At 330V of reflector bias, activation energy of the doped nc-Si thin film reduced as low as 0.001 eV. This means dopants are fully occupied as substitutional site, even though the Si thin film has nano-sized grain structure. And activated dopant concentration is recorded as high as up to 1020 #/$cm^3$ at very low process temperature (< $80^{\circ}C$) process without any post annealing. Theoretical solubility for the higher dopant concentration in Si thin film for order of 1020 #/$cm^3$ can be done only high temperature process or post annealing over $650^{\circ}C$. In general, as decreasing the grain size, the dopant binding energy increases as ratio of 1 of diameter of grain and the dopant hardly be activated. The highly doped nc-Si thin film by low-temperature NBaCVD process had smaller average grain size under 10 nm (measured by GIWAXS, GISAXS and TEM analysis), but achieved very higher activation of phosphorous dopant; NB energy sufficiently transports its energy to doping and crystallization even though without supplying additional thermal energy. TEM image shows that incubation layer does not formed between nc-Si film and SiO2 under later and highly crystallized nc-Si film is constructed with uniformly distributed nano-grains in polymorphous tissues. The nucleation should be start at the first layer on the SiO2 later, but it hardly growth to be cone-shaped micro-size grains. The nc-grain evenly embedded pm-Si thin film can be formatted by competition of the nucleation and the crystal growing, which depend on the NPB energies. In the evaluation of the light soaking degradation of photoconductivity, while conventional intrinsic and n-type doped a-Si thin films appeared typical degradation of photoconductivity, all of the nc-Si thin films processed by the NBaCVD show only a few % of degradation of it. From FTIR and RAMAN spectra, the energetic hydrogen NB atoms passivate nano-grain boundaries during the NBaCVD process because of the high diffusivity and chemical potential of hydrogen atoms.

  • PDF

Simultaneous Determination and Monitoring of Bisphenols in River Water using Gas Chromatography-Mass Spectrometry (GC-MS 를 이용한 하천수 중 Bisphenol계 화합물의 동시분석 및 모니터링)

  • Kim, Jihyun;Choi, Jeong-Heui;Kang, Tae-Woo;Kang, Taegu;Hwang, Soon-Hong;Shim, Jae-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.3
    • /
    • pp.154-160
    • /
    • 2017
  • BACKGROUND:This study was carried out to establish an efficient sample preparation for the simultaneous determination of bisphenols (BPs) in river water samples using gas chromatography-mass spectrometry (GC-MS). Sample preparation was examined with conventional extraction methods, such as solid-phase extraction (SPE) and liquid-liquid extraction (LLE), and their efficiency was compared with validation results, including linearity of calibration curve, method detection limit (MDL), limit of quantification (LOQ), accuracy, and precision. METHODS AND RESULTS:The BPs (bisphenol A, BPA; bisphenol B, BPB; bisphenol C, BPC; bisphenol E, BPE; bisphenol F, BPF; bisphenol S, BPS) were analyzed using GC-MS. The range of MDLs by SPE and LLE methods was $0.0005{\sim}0.0234{\mu}g/L$ and $0.0037{\sim}0.2034{\mu}g/L$, and that of LOQs was $0.0015{\sim}0.0744{\mu}g/L$ and $0.0117{\sim}0.6477{\mu}g/L$, respectively. The calibration curve obtained from standard solution of $0.004{\sim}4.0{\mu}g/L$ (SPE) and $0.016{\sim}16{\mu}g/L$ (LLE) showed good linearity with $r^2$ value of 0.9969 over. Accuracy was 93.2~108% and 97.4~120%, and precision was 1.7~4.6% and 0.7~6.5%, respectively. The values of MDL and LOQ resulted from the SPE method were higher than those from the LLE method, particularly those values of BPA were highest among the BPs. Based on the results, the SPE method was applied to determine the BPs in river water samples. Water samples were collected from mainstream, tributary and sewage wastewater treatment plants (SWTPs) in the Yeongsan river basin. The concentration of BPB, BPC, BPE, BPF and BPS were not detected in all sites, whereas BPA was ranged $0.0095{\sim}0.2583{\mu}g/L$, which was $0.0166{\sim}0.0810{\mu}g/L$ for mainstreams, $0.0095{\sim}0.2583{\mu}g/L$ for tributaries, $0.0352{\sim}0.1217{\mu}g/L$ for SWTPs. CONCLUSION: From these results, the SPE method was very effective for the simultaneous determination of BPs in river water samples using GC-MS. We provided that it is a convenient, reliable and sensitive method enough to monitor and understand the fate of the BPs in aquatic ecosystems.

Evaluation of Prognostic Factors in Corrected Transposition of the Great Arteries at Mid-term Follow-up (수정 대혈관 전위 환자에서 예후에 영향을 주는 인자들에 대한 중기적 고찰)

  • Song, Young-Hwan;Kwon, Hyok-Joo;Kim, Gi-Beom;Kang, Soo-Jung;Bae, Eun-Jung;Noh, Chung-Il;Yun, Yong-Soo;Lee, Jeong-Ryul;Kim, Yong-Jin;Rho, Joon-Ryang
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.2
    • /
    • pp.154-161
    • /
    • 2003
  • Purpose : The prognosis of patients with corrected transposition of the great arteries(C-TGA) is variably affected by associated intracardiac defects, systemic right ventricular function, tricuspid valve competence, and conduction disturbances. This study aims to evaluate the importance of those factors at mid-term follow-up. Methods : Medical records of 94 patients(males 58, females 36; mean age at last follow-up, $12{\pm}9$ years; mean follow-up duration, $9{\pm}6.4$ years) diagnosed between January 1980 and May 2002 at Seoul National University Children's Hospital were studied retrospectively. Results : Among 94 patients, operations were performed in 72 patients(classic operations in 55; double switch operations in 17). Among prognostic factors including associated intracardiac anomalies(at least moderately severe tricuspid insufficiency(TI), ventricular septal defect, pulmonary stenosis and pulmonary atresia), intracardiac operation and complete atrioventricular block, TI was the only significant factor for death(P=0.001), and in turn, Ebstein anomaly and high grade atrioventricular block predicted TI. 20-year survival without TI was 77%, but only 35% with TI(P=0.0002); excluding perioperative death, the 20-year survival rates with and without TI were 48% and 87% respectively(P=0.008). There was no statistical difference in 20-year survival rate or association with TI between classic and double switch operation. Conclusion : TI was the major prognostic factor for C-TGA and was associated with Ebstein anomaly and high grade atrioventricular block at mid-term follow-up. Long-term follow-up is required to evaluate other factors, including double switch operations and associated intracardiac defects more exactly.

Design of the Condenser and Automation of a Solar Powered Water Pump (태양열 물펌프의 운전 자동화 설계)

  • Kim Y. B.;Son J. G.;Lee S. K.;Kim S. T.;Lee Y. K.
    • Journal of Animal Environmental Science
    • /
    • v.10 no.3
    • /
    • pp.141-154
    • /
    • 2004
  • The solar powered water pump is very ideal equipment because solar power is more intensive when the water is more needed in summer and it is very helpful in the rural area, in which the electrical power is not available. The average so]ar radiation energy is 3.488 kWh/($m^2{\cdot}day$) in Korea. In this study, the automatic control logic and system of the water pump driven by the radiation energy were studied, designed, assembled, tested and analyzed for realizing the solar powered water pump. The experimental system was operated automatically and the cycle was continued. The average quantity of the water pumped per cycle was about 5,320 cc. The cycle time was about 4.9 minutes. The thermal efficiency of the system was about $0.030\%$. The pressure level of the n-pentane vapour in flash tank was 150$\%$450 hPa(gauge) which was set by the computer program for the control of the vapour supply. The pressure in the condenser and air tank during cycles was maintained as about 600 hPa and 1,200 hPa respectively. The water could be pumped by the amount of 128kg/($m^2{\cdot}day$) with the efficiency of $0.1\%$ and the pumping head of 10 m for the average solar energy in Korea.

  • PDF

A Kinematic Analysis of Uchi-mata(inner thigh reaping throw) by Kumi-kata types in Judo (유도 맞잡기 타입에 따른 허벅다리걸기의 Kinematic 분석[I])

  • Kim, Eui-Hwan;Cho, Dong-Hee;Kwon, Moon-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.1
    • /
    • pp.63-87
    • /
    • 2002
  • The purpose of this study was to analyze the kinematic variables when Uchi-mata(inner thigh reaping throw) performing by Kumi-kata(engagement position, basic hold) types A, B(A: grasping part-behind neck lapel, B: chest lapel) in Judo with three dimensional analysis technique DLT method by videography. The subjects were four male judokas who have been training in Yong-In University(YIU), on Korean Representative level and Uchi-mata is their tokui-nage(favorite technique), the throwing form was filmed on two S-VHS 16mm video camera( 30frame/sec. Panasonic). Kinematic variables were temporal, posture, and COG. The data collection was performing by Uchi-mata. Six good trials were collected for each condition (type A, B) among over 10 trials. The mean values and the standard deviation for each variable were obtained and used as basic factors for examining characteristics of Uchi-mata by Kumi-kata types. The results of this analysis were as follows : 1) Temporal variables The total time elapsed(TE) by Uchi-mata of types A, B were 1.45, 1.56 sec. respectively. Types A shorter than B. 2) Posture variables In performing of Uchi-mata, the range of flexion in type A, left elbow was $45^{\circ}$ and B was $89^{\circ}$ from Event 2(E2) to Event 6(E6). Type A and B were quite different in right elbow angle in Event1(E1). Left shoulder angle of type A was extended and type B was flexed in E4. Both types right shoulder angles were showed similar pattern. Also both hip angles(right/left) were showed similar pattern. When type A performed Uchi-mata the knee-angle of supporting foot showed $142^{\circ}$in the 1st stage of kake phase[KP], and extended to $147^{\circ}$in the 2nd stage of KP. And the foot-ankle angle of supporting foot showed $83^{\circ}$in the 1st stage of KP, and extended to $86^{\circ}$in the 2nd stage of KP. moreover, The knee angle of attacking foot showed $126^{\circ}$in the 1st stage of KP, and extended to $132^{\circ}$in the 2nd stage of KP, and the foot-ankle angle of attacking foot showed $106^{\circ}$in the 1st stage of KP, and extended to $121^{\circ}$in the 2nd stage of KP. When type B performed Uchi-mata the knee-angle of supporting foot showed $144^{\circ}$in the 1st stage of KP, and extended to $154^{\circ}$in the 2nd stage of KP. And the foot-ankle angle of supporting foot showed $83^{\circ}$in the 1st stage of KP, and extended to $92^{\circ}$in the 2nd stage of KP. moreover, The knee angle of attacking foot showed $132^{\circ}$in the 1st stage of KP, and extended to $140^{\circ}$in the 2nd stage of KP, and the foot-ankle angle of attacking foot showed $103^{\circ}$in the 1st stage of KP, and extended to $115^{\circ}$in the 2nd stage of KP. During Uchi-mata performing, type A showed pulling pattern and type B showed lift-pulling pattern. As Kumi-kata types, it were different to upper body(elbow, shoulder angle), but mostly similar to lower body(hip, knee, ankle angle) on both types. 3) C. O. G. variables When the subjects performed Uchi-mata, COG of type A, B up and down in vertical aspect was 71cm, 73.8cm in height from the foot in the 2nd stage of KP. As Kumi-kata types, it were different on medial-lateral direction aspect but weren't different in Kuzushi phase on vertical direction aspect.

Effects of Total Mixed Ration with Wet Brewer's Grain on Nutrient Utilization in Breeding Korean Native Goats (맥주박을 첨가한 섬유질 배합사료가 번식흑염소의 영양소 이용율에 미치는 영향)

  • Choi, Sun-Ho;HwangBo, Soon;Kim, Sang-Woo;Sang, Byung-Don;Kim, Young-Keun;Jo, Ik-Hwan
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.26 no.3
    • /
    • pp.147-154
    • /
    • 2006
  • This study was conducted to investigate the effects of Total Mixed Ration(TMR) with wet brewer's grain on feed intake, nutrient digestibility and nitrogen retention of breeding Korean native goat. Twelve breeding Korean native goats were divided into four treatment groups, which were fed TMR containing 20, 30, 40% of wet brewer's grain and a control group fed concentrate feed and hay, respectively. Results are summarized as follows. Dry matter contents of TMR with wet brewer's grain was 61.46-65.81%, that of crude protein was 14.42-15.59%, ADF and NDF were 28.32-28.52, 53.46-54.16%, each. These were not different by supplemental level of brewer's grain in TMR. However, NFC contents were lower according to increase wet brewer's grain in TMR. Dry matter intake of TMR supplemented with 20% of brewer's grain was tend to be higher than those of control group. CP and digestible CP intake of TMR diets supplemented wet brewer's grain was intended to higher than those of a control group. NFC and digestible NFC intake were significantly higher in control group than in WBG40 treatment(p<0.05). Digestibilities of DM, ADF, NDF and NFC in control group were higher than those from TMR with wet brewer's grain(p<0.05). Digestibilities of CP of TMR with supplemented wet brewer's grain was tend to be higher than those of a control group. Nitrogen retention of TMR supplemented wet brewer's grain was tend to be somewhat higher compared to the control group

A Study on the Prevalence Rate of Hypertension and the Actual Conditions of Control (일 지역 성인의 고혈압 유병률 및 관리 실태)

  • Kim, Hyeon-Ok
    • Research in Community and Public Health Nursing
    • /
    • v.10 no.1
    • /
    • pp.154-172
    • /
    • 1999
  • In order to analyse the prevalence rate of hypertension and the actual conditions of control, we selected five districts out of eleven eups and myuns in Chinan Country. We administered structured questionaries to 309 adults above the age of 40, computerized the data using SPSS - PC+. More than 40.1% of adults over 40 in Chinan County have health disorders ranging from high blood pressure to hypertension including alert high blood pressure at 36.2%, relatively high. Among general characteristics, differences in the rate of hypertension were influenced by age, occupation and places of residence. Over 71 who are engaged in agriculture, who don't have jobs, who reside in Sungsu, Jungchun, Chinan-eup all have higher hypertension rates than other groups. Accordingly, the control of hypertension should be focused on these people. As a result of the control of blood pressure, the survey showed 93.0% of the subjects were checked mainly at hospitals clinics, health centers subhealth centers and community health posts more than once a year, relatively high level of blood pressure management. However, the difference between their blood pressure measurements at ordinary times and the level of blood pressure at the time of research was quite considerable. Only 47.3% of the subjects diagnosed with high blood pressure and 70.3% of the subjects with normal blood pressure recognized their blood pressure accurately 52.7% of the subjects diagnosed with high blood pressure showed errors in understanding their blood pressure at normal times. Because these errors can cause problems in the control of blood pressure, proper management should be executed through a systematic examination. As a result of the high blood pressure control condition, the average period of hypertension was 74.5( ${\pm}92.8$) months, 92.3% of the subjects were diagnosed with high blood pressure at hospitals clinics, health centers subhealth centers community health posts, but only 29.5% were examined after a general check up on high blood pressure was completed. 70.5% were diagnosed with high blood pressure only after measuring their blood pressure. 14.1% of the subjects were hospitalized because of falls influenced by high blood pressure. 33.3% attended hospitals and health centers regularily for medical treatment and this shows how low the rate of the control of blood pressure. Most people did not undergo medical treatment, because they had no painful symptoms (46.7%), they didn't need to take the medicine(28.9%), or they forget to take the medicine(20.0%). These problems in the control of hypertension were discovered in the process of diagnosing high blood pressure at health medical institutions. Many people did not recognize the need for consistent control of blood pressure. That is, although the diagnosis for high blood pressures performed at hospitals clinics, health centers subhealth centers and community health posts, was 92.3%, more than 70.5% of the subjects were not examined completely with regard to blood pressure. Accordingly, heath medical institutions must diagnose high blood pressure not only by only measuring blood pressure but also by using systematic process of examination. As for the people diagnosed with high blood pressure, one should perform consistent medical approaches and help them to recognize the importance of the continuous control of blood pressure through subject-oriented education. Problems the subjects experienced were the following numbness in the limbs easily paralyzed stitches in their shoulders which felt painful, stiff necks, occiputs felt heavy, headaches when they got up in the morning, felt dizzy when standing and moving their heads and poor eyesight. The rate of knowledge related to high blood pressure was 78.7 points, comparatively low. Whether they had normal blood pressure or hypertension made no difference. These results are not desirable. Adult-oriented education forgot the prevention and management of high blood pressure should be implemented. Hypertensive-oriented education should be especially reinforced. Because there was a difference in the level of knowledge according to age, academic career, occupation or place of residence, education related to hypertension should be intensified and focused on those over the age of 71 those who did not attend school, those who do not have jobs and are engaged in agriculture and residents living in Bugui, Jungchun regions. The degree of healthy life practice in hypertensives is poor, particularly weight control, as opposed to people who have normal blood pressure. It makes no difference in smoking, the amount of daily smoking, drinking, the control of salt because each result means that they are not practicing healthy life or modifying their life-style. The development and programs to improve a healthy life should be executed.

  • PDF

Effects of Dietary Astragalus membranaceus, Ginseng and Onion Complex on Growth Performance and Carcass Characteristics in Finishing Pigs (비육돈에 있어 황기, 인삼, 양파 혼합물의 급여가 성장 밑 도체 특성에 미치는 영향)

  • Hong, Jong-Wook;Kim, In-Ho;Kim, Ji-Hoon;Kwon, Oh-Suk;Lee, Sang-Hwan;Seo, Wan-Soo;Kim, Chul;Kim, Eul-Sang;Chung, Yun-Hwa
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.1
    • /
    • pp.149-154
    • /
    • 2002
  • Seventy two Duroc $\times$ Yorkshire $\times$ Landrace pigs (75.66$\pm$1.86 kg average initial body weight) were used in a 45 days growth assay to determine the effects of Astragalus membranaceus, ginseng and onion complex on growth performance and carcass characteristics of finishing pigs. Dietary treatments included 1) Control (basal diet), 2) AGO 0.25 (basal diet + 0.25% Astragalus membranaceus, ginseng and onion complex), 3) AGO 0.50 (basal diet+0.50% Astragalus membranaceus. ginseng and onion complex). For overall period, average daily weight gain increased as the concentration of Astragalus membranaceus, ginseng and onion complex in the diets was increased (linear effect, p<0.01). Gain/feed improved without significant difference (p>0.05) as the concentration of Astragalus membranaceus, ginseng and onion complex in the diets was increased. As adding level of Astragalus membranaceus, ginseng and onion complex increased in the diets, A grade appearances of carcass tended to increase (linear effect, p<0.01). The total and LDL+VLDL cholesterol concentrations in serum of pigs fed AGO 0.25 diet were lower than them of pigs fed Control and AGO 0.50 diets without significant difference (p>0.05). $L^{*}$-, $a^{*}$-, and $b^{*}$- value of M. longissimus dorsi muscle were not significantly different among the treatments (p>0.05). Total feed cost per kg of weight gain was lower in the AGO 0.50 treatment (813 won) than in the Control (830 won). The results obtained from this feeding trial suggest that the Astragalus membranaceus, ginseng and onion complex supplementation for finishing pigs had improved growth performance. However, carcass characteristic was not affected by supplemental Astragalus membranaceus, ginseng and onion complex.lex.x.

The study of bone density assessment on dental implant sites (임플란트 식립 부위의 골밀도 평가에 관한 연구)

  • Park, Su-Won;Jang, Soo-Mi;Choi, Byoung-Hwan;Son, Han-Na;Park, Bong-Chan;Kim, Chang-Hwan;Son, Jang-Ho;Sung, Iel-Yong;Lee, Ji-Ho; Cho, Yeong-Cheol
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.5
    • /
    • pp.417-422
    • /
    • 2010
  • Introduction: Bone density is one of the important factors for the long term success of endosseous implants. The bone density varies from site to site and from patient to patient. A preoperative evaluation of the bone density is quite useful to oral surgeons for planning dental implantation. More accurate information on the bone density will help surgeons identify suitable implant sites, thereby increase the success rate of dental implantation. This study examined the correlation between the bone density measured preoperatively by computed tomography (CT) and the implant primary stability measured by resonance frequency analysis. Furthermore, the effects of the implant sites, gender, age and generalized systemic disorder patients on the bone density and primary implant stability were examined. Materials and Methods: One hundred and fourteen patients were selected. None of the patients had undergone a tooth extraction or bone graft history in the previous year. Preoperatively, the patients underwent CT scanning to evaluate the Hounsfield unit (HU), and resonance frequency analysis (RFA) was used to evaluate the implant primary stability at the time of implant installation. All implants were 4.0 mm diameter and 11.5 mm length US II. All patients were recorded and the HU and implant stability quotient (ISQ) value were evaluated according to the sites, gender and age. Results: The highest HU values were found in the mandibular anterior site ($827.6{\pm}151.4$), followed by the mandibular molar site ($797{\pm}135.1$), mandibular premolar site ($753.8{\pm}171.2$), maxillary anterior site ($726.3{\pm}154.4$), maxillary premolar site ($656.7{\pm}173.8$) and maxillary molar site ($621.5{\pm}164.9$). The ISQ value was the highest in the mandibular premolar site ($81.5{\pm}2.4$) followed by the mandibular molar site ($80.0{\pm}5.7$), maxillary anterior site ($77.4{\pm}4.1$), mandibular anterior site ($76.4{\pm}11.9$), maxillary premolar site ($74.2{\pm}14.3$) and maxillary molar site ($73.7{\pm}7.4$). The mean HU and ISQ value were similar in females and males. (HU: P=0.331, ISQ: P=0.595) No significant difference was also found in the age group respectively. However, the correlation coefficients between the variables showed a closed correlation between the HU and ISQ value. Conclusion: These results showed close correlation between the bone density (HU) and primary stability value (ISQ) at the time of implant installation (Correlation coefficients=0.497, P<0.01). These results strengthen the hypothesis that it might be possible to predict and quantify the initial implant stability and bone density from a presurgical CT diagnosis.

Compliance Level of Universal Precautions to Hospital Infection and related factors of Health Care Workers in a University Hospital (대학병원 의료종사자들의 병원감염에 대한 예방지침 실행수준과 관련요인)

  • Yu, Mi Jong
    • Korean Journal of Occupational Health Nursing
    • /
    • v.7 no.2
    • /
    • pp.143-154
    • /
    • 1998
  • The purpose of this research is to suggest basic materials for the practical infection precaution program to protect health care workers from hospital infection by grasping their compliance level of Universal Precautions and examining the factors affecting them. The number of the health care workers we studied were 486, including the doctors, the nurses, and the lab technicians who were working in a university hospital. The period of this research was from Aug. 18th, 1997 to Aug. 30th, 1997. The method of the study was to measure the compliance level of Universal Precautions with the item of "Universal Precautions" established by CDC in 1987, and examine the questionnaire of 52 questions dividing related factors into socio-populational, individual, socio-psychological and organizational management ones. The data was analyzed by t-test. ANOVA, and chi-square test. The results were as follows : 1. An the compliance level of Universal Precautions, hand washing had the highest score(85.4%), and doctors(18.9%), nurses(44.0%), and lab technicians(7.6%), had a low compliance level in the safe handling of an injection syringe, and item not to handle patients and their samples when the subject suffered from dermatitis or injury had the lowest score of 17.1%. 23.3% of them said that they wear protection gown, goggles and mask. 2. Female's Compliance level of Universal Precautions Was higher than male. 3. The health care workers who had high recognition on Universal Precautions got significantly higher compliance level of Universal Precautions than those have low recognition on Universal Precautions(P<0.001). 4. The health care workers experienced a needle stick injury had a significantly higher compliance level of Universal Precautions than those who had not(P<0.000). 5. The health care workers who had infection protection education got a significantly higher compliance level of Universal Precautions than those who didn't(P<0.000). 6. The health care workers who had a firm belief in the effect of Universal Precautions got a higher compliance level of Universal Precautions than those who didn't. 7. The health care workers who had less conflicts between treating patient arid protecting them-selves got a higher compliance level of Universal Precautions than others with many conflicts. 8. The health care workers who had a high score in organizational management factors got a significantly higher compliance level of Universal Precautions than those with a low score(P<0.000). 9. Only 16.9 percent of the all respondents(82 in number) answered that they knew well or a little about the Universal Precautions, which is very low rate of recognition. 10. The variables which affected the score in organizational management factors were age, sex, education period, work experience, the kind of work, recognition on Universal Precautions, the experience of needle stick injury, revealing dangerous circumstance related to infection, and training on precaution again infection. According to the result above, compliance level of Universal Precautions showed high correlation with sex, the recognition on Universal Precautions, the experience of needle stick injury, training on precaution against infection, the belief in the effect of Universal Precautions, the recognition degree of conflicts and organizatinal management factors. These results could be used as the basic materials for the developing infection protection programs. Also, There should have a systematic training course to elevate a effective compliance level of Universal Precautions as well as the manageeent of infection protection programs.

  • PDF