• 제목/요약/키워드: 14K gold alloy

검색결과 26건 처리시간 0.025초

침적법과 전기화학법을 이용한 티타늄의 갈바닉 부식에 관한 연구 (A STUDY ON THE GALVANIC CORROSION OF TITANIUM USING THE IMMERSION AND ELECTROCHEMICAL METHOD)

  • 계기성;정재헌;강동완;김병옥;황호길;고영무
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.584-609
    • /
    • 1995
  • The purpose of this study was to evaluate the difference of the galvanic corrosion behaviour of the titanium in contact with gold alloy, silva-palladium alloy, and nickel-chromium alloy using the immersion and electrochemical method. And the effects of galvallit couples between titanium and the dental alloys were assessed for their usefulness as materials for superstructure. The immersion method was performed by measuring the amount of metal elementsreleased by Inductivey coupled plasma emission spectroscopy(ICPES) The specimen of fifteen titanium plates, the five gold alloy, five silver-palladium, five nickel-chromium plates, and twenty acrylic resin plates ware fabricated, and also the specimen of sixty titanium plugs, the thirty gold alloy, thirty silver-palladium, and nickelc-hromium plugs were made. Thereafter, each plug of gold alloy, silver-palladium, and nickel-chromium inserted into the the titanium and acrylic resin plate, and also titanium plug inserted into the acrylic resin plate. The combination specimens uf galvanic couples immersed in 70m1 artificial saliva solution, and also specimens of four type alloy(that is, titanium, gold, silver-palladium and nickel-chromium alloy) plugs were immersed solely in 70m1 artificial sativa solution. The amount of metal elements released was observed during 21 weeks in the interval of each seven week. The electrochemical method was performed using computer-controlled potentiosta(Autostat 251. Sycopel Sicentific Ltd., U.K). The wax patterns(diameter 11.0mm, thickness,in 1.5mm) of four dental casting alloys were casted by centrifugal method and embedded in self-curing acrylic resin to be about $1.0cm^2$ of exposed surface area. Embedded specimens were polished with silicone carbide paper to #2,000, and ultrasonically cleaned. The working electrode is the specimen of four dental casting alloys, the reference electrode is a saturated calmel electrode(SCE) and the ounter electrode is made of platinum plate. In the artificial saliva solution, the potential scanning was carried out starting from-700mV(SCE) TO +1,000mV(SCE) and the scan rate was 75mV/min. Each polarization curve of alloy was recorded automatically on a logrithmic graphic paper by XY recorder. From the polarization curves of each galvanic couple, corrosion potential and corrosion rates, that is, corrosion density were compared and order of corrosion tendency was determined. From the experiments, the following results were obtained : 1. In the case of immersing titanium, gold alloy, silver-palladium alloy, and nickel-chromium alloysolely in the artificial saliva solution(group 1, 2, 3, and 4), the total amount of metal elements released was that group 4 was greater about 2, 3 times than group 3, and about 7.8 times than group 2. In the case of group 1, the amount of titanium released was not found after 8 week(p<0.001). 2. In the case of galvanic couples of titanium in contact with alloy(group 5, 6), the total amount of metal elements released of group 5 and 6 was less than that of group 7, 8, 9, and 10(p<0.05). 3. In the case of galvanic couples of titanium in contact with silver-palladium alloy(group 7, 8), the total amount of metal elements released of group 7 was greater about twice than that of group 5, and that of group 8 was about 14 times than that of group 6(p<0.05). 4. In the case of galvanic couples of titanium in contact with nickel-chromium alloy(group 9, 10), the total amount of metal elements released of group 9 and 10 was greater about 1.8-3.2 times than that of group 7 and 8, and was greater about 4.3~25 times than that of group 5 and 6(p<0.05). 5. In the effect of galvanic corrosion according to the difference of the area ratio of cathode and anode, the total amount of metal elements released was that group 5 was greater about 4 times than group 6, group 8 was greater about twice than group 7, and group 10 was greater about 1.5 times than group 9(p<0.05). 6. In the effect of galvanic corrosion according to the elasped time during 21 week in the interval of each 7 week, the amount of metal elements released was decreased markedly in the case of galvanic couples of the titanium in contact with gold alloy and silver-palladium alloy but the total amount of nickel and beryllium released was not decreased markedly in the case of galvanic couples of the titanium in contact with nickel-chromium alloy(p<0.05). 7. In the case of galvanic couples of titanium in contact with gold alloy, galvanic current was lower than any other galvanic couple. 8. In the case of galvanic couples of titanium in contact with nickel-chromium alloy, galvanic current was highest among other galvanic couples.

  • PDF

다양한 온도의 Age-hardening에 따른 14K Yellow Gold의 경도변화

  • 윤돈규;서진교;박종완
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 추계학술발표대회
    • /
    • pp.38.1-38.1
    • /
    • 2011
  • Yellow gold는 아름다운 광택과 손쉬운 가공성의 장점 때문에 장신구를 비롯한 다양한 분야에서 그 활용 가치가 매우 높다. 본 연구에서는 yellow gold의 hardness 강화 및 품질향상을 위하여 다양한 열처리 조건 별 기계적 특성 변화를 비교 관찰 하였다. 열처리 전 yellow gold alloy의 구성성분을 조사하기 위하여 EPMA와 ICP-MS를 사용하여 정성분석 및 정량분석 결과를 수치화 하였다. 총 44개의 14K yellow gold를 사용하여 $750^{\circ}C$, 30 min 의 조건에서 solid solution treatment 후 $200{\sim}350^{\circ}C$ 온도 범위에서 $50^{\circ}C$ 간격으로 age-hardening을 실시하였다. 또한 열처리 전과 후 grain 들의 배열 및 size 변화를 관찰하기 위해 식각을 실시하였다. 식각된 시료는 optical microscope (OM)을 통해 각 열처리 조건에 따라 전 후 변화를 관찰 하였다. 열처리 전 14K yellow gold의 hardness의 평균값은 120.6 Hv를 나타내었다. Solid solution treatment 후 hardness는 95.7 Hv로 평균값이 감소하였고, age-hardening 후에는 14K yellow gold는 $260^{\circ}C$에서 159.8 Hv, $270^{\circ}C$에서 170.2 Hv로 열처리 전에 비해 약 41% 증가된 결과를 나타내었다. 하지만 $270^{\circ}C$ 부터는 over-aging 현상을 나타내었다. OM 분석 결과 열처리 전 불균일했던 grain들의 배열이 solid solution treatment 및 quenching 후 다소 균일해 짐을 확인할 수 있었고, grain size 또한 열처리 전에 비해 증가함을 알 수 있었다. Solid solution treatment 후 모든 시료의 hardness 값이 전반적으로 감소하였다가 age-hardening을 통해 grain들의 배열이 점차 안정화 되면서 hardness가 증가 하였고, over-aging 구간에서는 급격히 감소하는 경향을 나타내었다. 이 결과로 우리는 14K yellow gold에 대한 age-hardening 최적조건을 도출 하였고, 각 열처리 조건 별 grain 배열 상태의 변화를 관찰 할 수 있었다.

  • PDF

국소의치용 티나늄의 피로도 및 물리적 성질에 관한 연구 (A STUDY ON THE FATIGUE AND PHYSICAL PROPERTIES OF TITANIUM USED IN REMOVABLE PARTIAL DENTURES)

  • 김학선;김광남;장익태
    • 대한치과보철학회지
    • /
    • 제32권2호
    • /
    • pp.249-267
    • /
    • 1994
  • The purpose of this study was to compare the fatigue, physical properties, flexibility and surface roughness of titanium used in removable partial dentures with those of a type IV and alloy and a cobalt- chromium alloy. Fatigue testing subjected the test specimen to rapid cycling at a given stress until failure occurred by using a small-sized, electrodynamic type bending fatigue testing machine. The S-N curves for the framework materials were generated. For tensile testing, a tensile bar as described in the ADA Specification No.14 was subjected to tensile loading until failure occurred. Load-displacement curves were generated for 18 gauge round specimen and tapered half round specimen. Then the flexibilities were calculated. The surface roughnesses were compared by analyzer. Through analyses of the data, the following conclusions were obtained. 1. The fatigue property of titanium was higher than that of a type IV gold alloy$(p\leq0.05)$, but there was no significant difference between titanium and a cobalt-chromium alloy $(p\geq0.05)$. 2. The yield strength, the ultimate tensile strength and Victors hardness of titanium were higher than those of a type IV gold alloy but lower than those of a coalt-chromium alloy$(p\leq0.05)$. 3. The percentage of elongation and reduction of area of titanium were the highest $(p\leq0.05)$. 4. The surface roughness of titanium was the greatest$(p\leq0.05)$. 5. The flexibility of titanium was lower than that of a type IV gold alloy but higher than that of a cobalt-chromium alloy$(p\leq0.05)$.

  • PDF

Debonding forces of three different customized bases of a lingual bracket system

  • Sung, Jang-Won;Kwon, Tae-Yub;Kyung, Hee-Moon
    • 대한치과교정학회지
    • /
    • 제43권5호
    • /
    • pp.235-241
    • /
    • 2013
  • Objective: The purpose of this study was to investigate whether extension of the custom base is necessary for enhancement of bond strength, by comparing the debonding forces and residual adhesives of 3 different lingual bracket systems. Methods: A total of 42 extracted upper premolars were randomly divided into 3 groups of 14 each for bonding with brackets having (1) a conventional limited resin custom base; (2) an extended gold alloy custom base: Incognito${TM}$; and (3) an extended resin custom base: KommonBase${TM}$. The bonding area was measured by scanning the bracket bases with a 3-dimensional digital scanner. The debonding force was measured with an Instron universal testing machine, which applied an occlusogingival shear force. Results: The mean debonding forces were 60.83 N (standard deviation [SD] 10.12), 69.29 N (SD 9.59), and 104.35 N (SD17.84) for the limited resin custom base, extended gold alloy custom base, and extended resin custom base, respectively. The debonding force observed with the extended resin custom base was significantly different from that observed with the other bases. In addition, the adhesive remnant index was significantly higher with the extended gold alloy custom base. Conclusions: All 3 custom-base lingual brackets can withstand occlusal and orthodontic forces. We conclude that effective bonding of lingual brackets can be obtained without extension of the custom base.

주조용(鑄造用) 합금(合金)의 조직반응(組織反應)에 관(關)한 실험적(實驗的) 연구(硏究) (A STUDY ON THE BIOLOGICAL TISSUE RESPONSE OF DENTAL CASTING ALLOYS)

  • 임정규
    • 대한치과보철학회지
    • /
    • 제14권1호
    • /
    • pp.31-34
    • /
    • 1976
  • The author studied the effects of some dental gold alloys and dental nonprecious metals on muscle. The metal specimens were cast in the size of $1.0mm.{\times}5.0mm.{\times}3.0mm.$ and implanted in the gluteus maximus musculus of the two dogs. The subjects were sacrificed at 3 weeks and 5 weeks respectively after implantation. The tissue was examined his to-pathologically. The findings were as follows. 1. The more the alloy contains gold, the less the tissue response to the alloy and the less the connective tissue layer around the specimens. 2. The recovery of connective tissue layer in gold specimens was markedly observed. 3. There were very thick connective layers around nonprecious specimens.

  • PDF

합금의 종류와 지대주 성분이 바형 유지 장치의 변연 적합도에 미치는 영향 (Effect of various casting alloys and abutment composition on the marginal accuracy of bar-type retainer)

  • 이윤희;송영균;이준석
    • 대한치과보철학회지
    • /
    • 제50권2호
    • /
    • pp.85-91
    • /
    • 2012
  • 연구 목적: 합금의 종류와 지대주의 재질의 차이가 변연적합도에 미치는 영향을 비교 분석하고자 한다. 연구 재료 및 방법: 2개의 임플란트 유사체를 평행하게 위치시킨 후 아크릴릭 레진으로 포매하여 연구모형을 제작하였다. 바 구조물은 gold UCLA 지대주에 고귀금속 합금(high noble metal alloy)과 귀금속 합금(noble metal alloy)을, 그리고 metal UCLA 지대주에 고귀금속 합금과 비귀금속 합금(base metal alloy)을 이용하여 총 4 종류의 바 구조물을 7개씩 시편을 제작하였다. 주조된 바 구조물을 레진 모형에 장착하고 한쪽 지대나사를 조인 후, 반대쪽 임플란트-지대주 간극의 수직 거리를 앞, 뒤, 측면 3부위에서 입체 광학 현미경으로 관찰하여 기록하였다. 결과: 각 군들의 변연오차 평균값은 gold UCLA 지대주에 고귀금속 합금과 귀금속 합금을 사용했을 때 각각 $13.69{\pm}6.74{\mu}m$$267.26{\pm}65.85{\mu}m$이었으며, metal UCLA 지대주에 고귀금속 합금과 비귀금속 합금을 사용했을 때 $26.19{\pm}8.14{\mu}m$$61.90{\pm}33.65{\mu}m$이었다. One-way ANOVA를 이용하여 변연 적합도의 차이를 분석했을 때 고귀금속 함금을 사용한 군들을 제외하고, 모든 군간에 유의한 차이가 존재하였다($P$<.05). Gold UCLA 지대주-귀금속 합금 조합을 제외하고 모두 $70{\mu}m$ 이하의 수직오차를 보였다. 결론: 임플란트 바 유지 장치의 제작에 있어서 고귀금속 합금 대신 비귀금속 합금과 metal UCLA 지대주를 사용하는 것은 임상적 타당성이 있다고 판단된다.

백색금 합금용 모합금의 실리콘 함량에 따른 물성변화 (Properties of the Master Alloys for White Gold Products with Silicon Contents)

  • 송정호;노윤영;이현우;최민경;송오성
    • 한국재료학회지
    • /
    • 제25권2호
    • /
    • pp.90-94
    • /
    • 2015
  • We prepared 8 samples of non-silver and silver-added master alloys containing silicon to confirm the existence of nickel-silicides. We then prepared products made of 14K and 18K white gold by using the prepared master alloys containing 0.25, 0.35, and 0.50 wt% silicon to check for nickel release. We then employed the EN 1811 testing standard to investigate the nickel release of the white gold products, and we also confirmed the color of the white gold products with an UV-VIS-NIR-color meter. We observed $NiSi_x$ residue in all master alloys containing more than 0.50 wt% Si with EDS-nitric acid etching. For the white gold products, we could not confirm the existence of $NiSi_x$ through XRD after aqua-regia etching. In the EN 1811 test, only the white gold products with 0.25 wt% silicon master alloys successfully passed the nickel release regulations. Moreover, we confirmed that our white gold products showed excellent Lab indices as compared to those of commercial white gold ones, and the silver-added master alloys offered a larger L index. Our results indicate that employing 0.25 wt% silicon master alloys might be suitable for white gold products without nickel-silicide defects and nickel release problems.

Investment casting 공정에서 수축률을 고려한 소형탕도의 이상적인 구조와 주형 온도에 관한 연구 (A study on structure of feed sprue considering turbulence and mold temperature in the investment casting process)

  • 이종래
    • 한국결정성장학회지
    • /
    • 제32권1호
    • /
    • pp.25-32
    • /
    • 2022
  • 인베스트먼트 주조는 정밀기기, 의료분야, 액세서리 등의 제조에 일반적으로 사용되는 생산방식으로 장비의 현대화와 고품질의 재료를 통해 발전을 거듭해 왔으며 그 활용 범위가 확대되고 있다. 본 연구의 목적은 인베스트먼트 주조 공정의 핵심 요소인 금형 온도의 구조적 개선 및 표준화를 도출하여 불량률을 최소화하여 경제성과 생산성을 향상시키는 것이다. 연구의 범위는 소형탕도의 구조와 원리를 이해하기에 적합한 Jewelry 제조 주조 공정에 국한되어 있으며 연구 재료로 soft Wax, 석고 분말 및 14 K Gold를 사용하여 실험적 연구를 수행했다. 그 결과 Alloy 14 k의 주물 패턴에 가장 적합한 주물 표준 온도는 980℃ 플라스크 온도 550℃에서 가장 낮은 난류로 좋은 제품을 생산할 수 있었다. 본 연구의 향후 과제로 소형탕도의 구조 및 표준온도를 데이터를 분석하고, 현장의 생산 불량을 감소시키고 우수한 인베스트먼트 주조 공법의 경쟁력 확보를 위한 데이터를 제공하기 위한 세부 연구가 필요하다.

한국산(韓國産) 치과주조용(齒科鑄造用) 저금함유합금(低金含有合金)의 조성(組成) 및 기계적(機械的) 성질(性質)에 관(關)한 비교연구(比較硏究) (A COMPARATIVE STUDY ON THE CHEMICAL COMPOSITION AND MECHANICAL PROPERTIES OF FOUR LOW-GOLD-CONTENT DENTAL CASTING ALLOYS MANUFACTURED IN KOREA)

  • 장익태;양재호;김창회;김광남;이선형;김영수;장완식
    • 대한치과보철학회지
    • /
    • 제19권1호
    • /
    • pp.17-27
    • /
    • 1981
  • This study was conducted to determine the chemical composition and the mechanical properties of four commercially available low gold-based crown and bridge alloy produced in Korea. Four dental casting gold-silver-palladium alloys, i.e., A, B, C and D (code of alloys) were selected for the evaluation of chemical composition, ultimate tensile strength, elongation. values and Vickers hardness. The chemical composition of test specimens was analyzed by both emission spectrography and wet gravitation method with a 1.5gm of low gold ingot. The tensile properties and Vickers hardness was determined with cast specimens treated in following three conditions; as-cast, softening heat treatment and hardening heat treatment. The tensile testing bars were cast in accordance with the model designed by Gettleman and Harrison (1969) which was modified from the A. D. A. Specification No. 14 for dental chromium-cobalt casting alloy. Nine tensile test specimens were made from a split silicone mold for each of the test alloys to the size of 2.5mm in diameter and a gauge length of 10mm. All four alloys were handled in accordance with conventional methods used in Type III gold alloys. Ultimate tensile strength and elongation were measured on an Instron Universal Tensile Testing Machine (Model 1125, Japan) operated at a crosshead rate of 0.1cm/min. Elongation values were measured using Digital Measuring Microscope (MS-152, FUSOH, Japan). Vickers hardness was determined with a Vickers Hardness Tester (Model VKH-l, Japan) at a 1.0kg load on a mounted tensile test specimen. The following results were obtained from this study; 1. All tested alloys were composed of Au, Ag, Pd, Cu, Zn and Fe in common. The composition rate of gold for all four alloys was found in the range of $42{\sim}47$ weight % as shown below. Alloy A; Au 45%, Ag 40.2%, Pd 5.76%, others 9.04%. Alloy B; Au 47.1%, Ag 29.03%, Pd 6.98%, others 16.92%. Alloy C; Au 45%, .Ag 26.9%, Pd 6.83%, others 21.07%. Alloy D; Au 41.8%, Ag 34.4%, Pd 6.95%, others 16.85%. 3. The ultimate tensile strength of the four alloys was in the range of $31{\sim}82kg/mm^2$. The test results were shown in the below order from the highest value; As-cast condition; D, B, C, A. Softening heat treament; B, C, D, A. Hardening heat treatment; D, B, C, A. 4. The test :results of the elongation rate for each alloy were in the range of $0.5{\sim}18%$. The test results were shown in the below order from the highest value; As-cast condition; A, D, B, C. Softening heat treatment; A, C, D, B. Hardening heat treatment; C, D, B, A. 5. Vickers hardness for each of the four alloys was in the range of $120{\sim}230$. The test results were shown in the below order from the highest value; As-cast condition; C, B, D, A Softening heat treatment; D, B, C, A. Hardening heat treatment; D, A, C, B. 6. There were no differences in the physical properties between as-cast condition and softening heat treatment.

  • PDF

수종 임플랜트 지대주나사의 반복하중 후 나사풀림에 관한 연구 (A STUDY OF SCREW LOOSENING AFTER DYNAMIC CONTINOUS FATIGUE TEST OF SEVERAL ABUTMENT SCREW)

  • 김진만;한중석;이선형;양재호;이재봉;김영수
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.519-531
    • /
    • 2003
  • Statement of problem : Chronic implant screw loosening remains a problem in restorative practices. Some implant manufactureres have introduced abutment screws with treated material, surfaces and macrostructures in an effort to reduce potential loosening. Purpose : This study evaluated the materials and loading cycles on detorque value after dynamic continous fatigue test in the sinulated conditions of posterior single restoration. Material and method : Fourteen of each of the following abutment screws - titanium alloy, gold alloy, gold-tite, and titanium alloy modified - were used in test. SEM is used to verify macrostructures of each screws. $ZrO_2/Al_2O_3$ composite abutment was tightened on $4{\times}10.0mm$ titanium external implant at 30 Ncm. Cyclic loading machine delivered dynamic loading forces between 20 and 320N for 100,000, 200,000, 300,000, 500,000, and 1,000,000 cycles at frequencies 14Hz. Torque and detorque value after loading was measured. Results : All measued screws had different screw length and thread form. Titanium modified screw had greater detorque value than others before and after cyclic loadings(p<0.05). All abutment screws had no significant change in mean percentage of detorque value after loading to initial value after less than 500.000 cyclic loadings, but significant lower value after 1,000,000 cycles(p<0.05). Conclusion : Within limintations of this study all abutment screws may be loosend after about 1 year use. Annual check-up is nessasary to prevent screw loosening.