• Title/Summary/Keyword: 125kHz

Search Result 118, Processing Time 0.021 seconds

A study on the dielectric properties by measurement of relaxation time of dipole polarization in solid dielectrics (고체유전체의 쌍극자분극 완화시간 측정에 의한 유전특성의 연구)

  • 박중순;서장수;김병인;국상훈
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.05a
    • /
    • pp.125-129
    • /
    • 1992
  • When relaxation time will be distributed, TSC observed in the experimental procedure was analysed by using a potential model having two equilibrium positions and equations of dielectric properties was derived. Calculation of distribution was made by matrix method and compared/confirmed values obtained by TSC and alternating current which have a correspondence with each other. In this measurement, distribution of activation energy and relaxation time was determined by TSC peak at around 147k/364 of which center is 10$\^$-4/ sec/10$\^$5/ sec respectively at room temperature and also obtained dielctric loss factor at the range of 10$\^$-7/-10$\^$5/Hz. It seems that low temperature peak is local dispersion and high temperature peak have a relation to dielectric transition of the material.

  • PDF

Effect of low frequency motion on the performance of a dynamic manual tracking task

  • Burton, Melissa D.;Kwok, Kenny C.S.;Hitchcock, Peter A.
    • Wind and Structures
    • /
    • v.14 no.6
    • /
    • pp.517-536
    • /
    • 2011
  • The assessment of wind-induced motion plays an important role in the development and design of the majority of today's structures that push the limits of engineering knowledge. A vital part of the design is the prediction of wind-induced tall building motion and the assessment of its effects on occupant comfort. Little of the research that has led to the development of the various international standards for occupant comfort criteria have considered the effects of the low-frequency motion on task performance and interference with building occupants' daily activities. It has only recently become more widely recognized that it is no longer reasonable to assume that the level of motion that a tall building undergoes in a windstorm will fall below an occupants' level of perception and little is known about how this motion perception could also impact on task performance. Experimental research was conducted to evaluate the performance of individuals engaged in a manual tracking task while subjected to low level vibration in the frequency range of 0.125 Hz-0.50 Hz. The investigations were carried out under narrow-band random vibration with accelerations ranging from 2 milli-g to 30 milli-g (where 1 milli-g = 0.0098 $m/s^2$) and included a control condition. The frequencies and accelerations simulated are representative of the level of motion expected to occur in a tall building (heights in the range of 100 m -350 m) once every few months to once every few years. Performance of the test subjects with and without vibration was determined for 15 separate test conditions and evaluated in terms of time taken to complete a task and accuracy per trial. Overall, the performance under the vibration conditions did not vary significantly from that of the control condition, nor was there a statistically significant degradation or improvement trend in performance ability as a function of increasing frequency or acceleration.

Electroacupuncture Applied to LR2 Ameliorates Pain Behavior in The Rat Model of Inflammatory Pain (행간 전침이 흰쥐 염증성 통증 모델의 통증 행동 완화에 미치는 영향)

  • Koo, Sungtae;Choi, Woo Young
    • Korean Journal of Acupuncture
    • /
    • v.34 no.4
    • /
    • pp.265-270
    • /
    • 2017
  • Objectives : The present study aimed to examine the analgesic effect of electroacupuncture(EA) applied to the brook point of the Liver meridian in the rat model of inflammatory pain and to investigate involvement of endogenouse opioid in the EA-induced analgesia. Methods : Knee arthritis was induced by injection of $125{\mu}l$ of complete Freund's adjuvant into the knee joint cavity unilaterally. To examine the level of pain, weight bearing forces(WBFs) of affected limb was measured. EA treatment was given at the LR2, LI4 or non-acupoint on the contralateral limb with frequency of 2 Hz and intensity of 2 mA under gaseous anesthesia. Results : After induction of arthritis, rats subsequently showed a reduced stepping force of the affected hindlimb due to a painful knee. EA applied to the LR2 point on the contralateral hind limb produced a significant improvement of stepping force of the hind limb lasting for at least 2 h, and this effect was equivalent to that obtained by 5 mg/kg of oral indomethacin. The effect of EA was specific to the acupoint since it could not be mimicked by EA applied to the LI4 point or the arbitrary non-acupoint. The analgesic effect was blocked by pretreatment with naltrexone(10 mg/kg, i.p.). Conclusions : These results suggest that acupuncture applied to LR2, brook point of Liver meridian suppresses inflammatory pain in a rat model of knee arthritis and this effect seems to be mediated by endogenous opioid systems.

Crystallization and Electrical Properties of $Ba_2TiSi_2O_8$ Glass-Ceramics from $K_2O-BaO-TiO_2-SiO_2$ System

  • Chae, Su-Jin;Lee, Hoi-Kwan;Kang, Won-Ho
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2006.10a
    • /
    • pp.110-114
    • /
    • 2006
  • Dielectric properties of glass-ceramics with fresnoite(Ba2TiSi208) crystals have been investigated in xK20-(33.3-x)BaO-16.7TiO2-50SiO2 ($0{\leq}x{\leq}20mol%$) glasses. The glassy nature was analyzed by differential thermal analyses and glass-ceramics was variable and control table by the processing parameters like time and temperature. Dielectric constant was measured over a temperature from 125K to 425k at frequencies form 100Hz to 1MHz, and laid in the range 16-10. Piezoelectric constant d33 was measured using a YE2703A d33meter and changed from 5.9 to 4.8pCN-1 with x contents. The spontaneous polarization Ps estimated from the hysteresis at ${\pm}1.2kV$ was ${\sim}0.3\;{\mu}C/cm2$ at room temperature.

  • PDF

Analysis of Sports Biomechanical Variable on the Motions of Left and Right Spikes of Volleyball (배구 레프트 스파이크와 라이트 스파이크 동작에 대한 운동역학적 변인 비교 분석)

  • Cho, Ju-Hang;Ju, Myung-Duck
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.4
    • /
    • pp.125-134
    • /
    • 2006
  • The purpose of this study was to analyze the Biomechanical elements by looking at the differences on the motions of the right and left spikes of right-handed offense volleyball players, using 3D image analysis and force platform. For that purpose, spike motions of six male university volleyball players were recorded three times each using two 16mm high speed cameras and the speed of recording was set at 60 frames/sec. The coordinated raw data was leveled as 6Hz using low pass filtering method and the calculation of 3D coordinates was done by using a DLT (Direct Linear Transformation) method. Also KWON 3D program was used to analyze the variables. Through the experiments and research, the following results were found: That is, in case of the right spike, the required time from the toss to the impact, which affected the success rate of offense showed as longer and on the take-off, the exact timing to touch the ball was longer because the pace between right and left feet was wider, and also after the jump, the distance between the feet indicated shorter, than the left. In addition, the degree of somersault and horizontal adduction of shoulder joint was smaller and the degree of medial rotation of shoulder joint showed bigger than the left, so it indicated that it was not centered on the body, but by the arm with an axis of shoulder using a swing motion. After the impact, the speed of the ball indicated slower compared to the left spike.

Application of RF-ID in Subway System (지하철 시스템에 대한 RF-ID의 적용)

  • Lee, Yong-Jea;Kim, Do-Hun;Kim, Yong-Sang;Yim, Sang-Wook;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.402-404
    • /
    • 2003
  • Radio frequency identification (RF-ID) is an automatic data capture (ADC) technology that comprises small data-carrying device(is called Tag) and fixed or mobile device(is called reader). Tags are attached or deattached device. Readers may be installed at locations where data capture is required, and may also be in the form of portable readers. In this paper, we are proposing an application for the subway station using the RF-ID system and a system for the gateless fare collection passing through the booth in only carrying the card. In this system that RF-ID system and Bluetooth are applied. We designed two wireless communication channels. One is the 125kHz communication channel by FSK and PSK for power supplying on the card and identification and the other is 2.4GHz channel for the collection.

  • PDF

Characteristics of periodical movement of live squid (Todarodes pacificus) hooked on the branch line of a red sea bream long line

  • Koo, Myung Sung;Ishizaki, Munechika;Kim, Suk Jong;Fuwa, Shigeru;Archdale, Miguel Vazquez
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.3
    • /
    • pp.227-237
    • /
    • 2013
  • In Jeju Island, red sea bream is mainly caught by long line with a live squid as bait. The movements of artificial jigs in the fishery are supposed to be an important factor for catching the target organism as well as bait. To develop new fishing method for long line fishery, movements of the bait which was squid were tried to be characterized. In a water tank experiment, a live squid was hooked by a fish hook attached to a model long line. And then movements of squids in the water tank were recorded for 20 minutes by a video camera. Recorded movement of the squid was just periodically up-and-down moving, with a dominant frequency of 0.125Hz, and amplitude of 10.8cm.

Output Characteristics of the PMS-PZT Piezoelectric Transformer Driving High Power Amplifier (PMS-PZT를 이용한 압전 변압기의 하이파워 시 출력 특성)

  • Kim, Dong-Soo;Kim, Young-Deog;Kim, Kwang-Il;Sohn, Joon-Ho;Nam, Hyo-Duk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.830-833
    • /
    • 2004
  • Voltage step-down characteristics of Ring/Dot type piezoelectric transformer were examined with increasing input voltage from $10\;V_{pp}$ to $140V_{pp}$. Then the output load resistance was fixed to $125\;\Omega$. The voltage gain showed constant value till the input voltage of $70\;V_{pp}$. And then it linearly decreased till the input voltage of $140V_{pp}$. The output voltage of fabricated piezoelectric transformer increased with increasing input voltage. And driving frequencies when the output voltage was maximum value were changed according to input voltage. Frequency shifts and temperature rise of fabricated sample showed 2 kHz, $13^{\circ}C$, respectively when input voltage was changed from $10\;V_{pp}$ to $140V_{pp}$. Because of the temperature rise of fabricated piezoelectric transformer, the step-down characteristics of it was deteriorated above the input voltage of $70\;V_{pp}$.

  • PDF

Optical VSB Filtering of 12.5-GHz Spaced 64 × 12.4 Gb/s WDM Channels Using a Pair of Fabry-Perot Filters

  • Batsuren, Budsuren;Kim, Hyung Hwan;Eom, Chan Yong;Choi, Jin Joo;Lee, Jae Seung
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.63-67
    • /
    • 2013
  • We perform an optical vestigial sideband (VSB) filtering using a pair of Fabry-Perot (FP) filters. The transmittance curve of each FP filter is made to have sharp skirts using an offset between input and output coupling fibers. Moreover, the accurate periodicity of FP filters in the optical frequency domain enables the simultaneous VSB filtering of a large number of optical channels. With this VSB filtering technique, we transmit 12.5-GHz spaced $64{\times}12.4-Gb/s$ wavelength-division-multiplexing channels over a single-mode fiber up to 150 km without any dispersion compensations. When the channel spacing is reduced to 10 GHz, we achieve the spectral efficiency of 1 bit/s/Hz in conventional optical intensity modulation systems up to 125 km.

A Design of 5.8 ㎓ Oscillator using the Novel Defected Ground Structure

  • Joung, Myoung-Sub;Park, Jun-Seok;Lim, Jae-Bong;Cho, Hong-Goo
    • Journal of electromagnetic engineering and science
    • /
    • v.3 no.2
    • /
    • pp.118-125
    • /
    • 2003
  • This paper presents a 5.8-㎓ oscillator that uses a novel defected ground structure(DGS), which is etched on the metallic ground plane. As the suggested defected ground structure is the structure for mounting an active device, it is the roles of a feedback loop inducing a negative resistance as well as a frequency-selective circuit. Applying the feedback loop between the drain and the gate of a FET device produces precise phase conversion in the feedback loop. The equivalent circuit parameters of the DGS are extracted by using a three-dimensional EM simulation ,md simple circuit analysis method. In order to demonstrate a new DGS oscillator, we designed the oscillator at 5.8-㎓. The experimental results show 4.17 ㏈m output power with over 22 % dc-to-RF power efficiency and - 85.8 ㏈c/Hz phase noise at 100 KHz offset from the fundamental carrier at 5.81 ㎓.