• Title/Summary/Keyword: 11a

Search Result 90,124, Processing Time 0.084 seconds

A Survey on Admission Control Mechanisms for providing QoS in the IEEE 802.11 Wireless LANs (IEEE 802.11 무선랜에서 QoS 제공을 위한 허가 제어 연구)

  • Lee, Kye-Sang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.535-538
    • /
    • 2005
  • Wireless LANs based on the IEEE 802.11 standard are widely spread for use nowadays. Traffic which are conveyed over the WLANs change rapidly from normal data such a Email and Web pages, to multimedia data of high resolution video and voice. To meet QoS (Quality of Service) required by these multimedia traffic, the IEEE 802 committee recently has developed a new standard, IEEE 802.11e. IEEe 802.11.e contains two MAC mechanisms for providing QoS: EDCA(Enhanced Distributed Channel Access) and HCCA (HCF Controlled Channel Access). Using these standardized MAC mechanisms as a building platform, various admission control mechanisms can be combined to offer QoS gurantees for multimedia traffic. This paper surveys these research efforts.

  • PDF

Wideband Array Antenna Design for Ku-Band Satellite Communications Using Mixed Patches (혼합 패치를 이용한 Ku 대역 위성통신용 광대역 배열 안테나 설계)

  • Seong-hun Kim;Ji-hwan Ko
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.3
    • /
    • pp.281-286
    • /
    • 2023
  • This paper proposes a design of a wideband array antenna involving the downlink bands of fixed satellite service (FSS) and broadcasting satellite service (BSS) by applying two mixed patch sets. The proposed antenna is implemented on FR4 substrate by arranging rectangular patches in 6 by 2. To design a wideband antenna (10.7~12.75 GHz) covering both FSS downlink bands (10.7~10.95 GHz, 11.2~11.45 GHz) and BSS downlink bands (11.7~12.5 GHz, 12.2~12.75 GHz, 11.7~12.2 GHz), rectangular patches working at 11.5 GHz and 12.5 GHz are arranged alternately, and thus the proposed antenna can obtain a wide bandwidth equivalent to 30.8% of the center frequency. The proposed antenna was fabricated and measured, and the results are well matched with the simulated ones. From the performances, the proposed antenna can be applied to the receiving antenna for FSS and BSS downlinks.

Clinical Application of 11C-Acetate Positron Emission Tomography-Computed Tomography (PET-CT) in Patients of Urinary System Cancer (비뇨기암 환자에서 11C-Acetate 양전자 방출 컴퓨터 단층 검사 (PET-CT)의 임상 적용)

  • Nam-Koong, Hyuk;Ham, Joon chul;Kim, Sang kyoo;Choi, Yong hoon;Lim, Han sang;Kim, Jae sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.9-13
    • /
    • 2016
  • Purpose PET-CT examinations using $^{18}F-FDG$ to treat urinary system cancer are limited in terms of anatomical structure and excretion route of $^{18}F-FDG$. But one of the ongoing examinations utilizing $^{11}C-Acetate$ can compensate for such defects. We would like to introduce a clinical application of $^{11}C-Acetate$ PET-CT in urinary cancer patients. Materials and Methods We conducted a clinical survey of 22 patients diagnosed with urinary cancer at our hospital, 10 prostate cancer patients, 10 renal cell carcinoma patients, and 2 bladder cancer patients. All patients were performed $^{18}F-FDG$ PET-CT examinations, $^{11}C-Acetate$ examinations were performed after two weeks on average. The equipment used to D-710 PET-CT in GE Company and we performed PET-CT procedures 15 minutes after injecting $^{11}C-Acetate$, and a medical doctor from the department of nuclear medicine appraised and compared images between $^{18}F-FDG$ and $^{11}C-Acetate$. Results According to our survey, prostate cancer patients generally had lower uptake of $^{18}F-FDG$ than other cancer patients did. In 2 out of 10 prostate cancer patients, metastasized cancer showed greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. In renal cell carcinoma cases, 8 out of 10 patients displayed evidently greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. We excluded bladder cancer cases in this study because uptake of $^{18}F-FDG$ in the bladder was too hot, the number of patients was insufficient, and the cases did not meet criteria such as the use of diuretics. Conclusion It is too premature to draw solid conclusions from the survey, since it involved only a small number of participants. However, there are a number of studies conducted abroad that prove the effectiveness of the $^{11}C-Acetate$ PET-CT examinations in treating urinary system cancer, and this study is still ongoing at our hospital. If the tests were to be conducted on a larger number of participants, this study could lead to numerous other potential research topics, such as the correlation between Prostatic specific antigen (PSA) values and $^{11}C-Acetate$ PET-CT, Gleason sum values from biopsy before surgery, Specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV) between $^{18}F-FDG$ PET-CT examinations and $^{11}C-Acetate$ PET-CT examinations in other urinary system cancers.

  • PDF

Purification of Methioninase from Pseudomonas putida and Its Effect on the Uptake of ^11C-Methionine in Vivo. (Pseudomonas putida 유래 Methioninase의 정제 및 생체내 ^11C-Methionine 섭취에 미치는 영향)

  • 변상성;박귀근
    • Microbiology and Biotechnology Letters
    • /
    • v.31 no.4
    • /
    • pp.377-382
    • /
    • 2003
  • Purification of methioninase resulted in a yield of 69%, and SDS-PAGE analysis of the purified product revealed a single band of approximately 43 kDa in molecular weight. in vitro experiments with cancer cells incubated in methionine-free media demonstrated an increase in $^{11}$ C-methionine uptake to 25.8$\pm$1.1% at 6 hr, 31.8$\pm$0.8% at 24 hr, and 62.2$\pm$0.6% at 48hr, compared to controls. Treatment of the cancer cells with purified methioninase showed no decrease in survival after a 2 hr incubation with 0.01 U/ml, but survival of RR1022 cells decreased 30% after 24 to 48 hr incubation. SKOV-3 cells showed a 5% and 14% decrease in survival with 0.1 and 1 U/ml methioninase after 24 hr. After 48hr survival decreased 15% and 24% with 0.1 and 1 U/ml methioninase. Measurements of $^{11}$ C-methionine uptake in RR1022 cells demonstrated no change at 2 hr, but a 13.7$\pm$4.7% and 40.7$\pm$2.6% increase in uptake at 24 and 48 hr, respectively. SKOV-3 cells also showed no change at 2 hr, but had a 17.7$\pm$7.2% and 38.9$\pm$4.9% increase in $^{11}$ C-methionine uptake after 24 hr and 48 hr treatment with methioninase, respectively. $^{11}$ C-methionine PET imaging revealed clear visualization of both the tumors and contralateral infectious lesions. Administration of rMET appeared to result in a slight increase in tumor:nontumor contrast on $^{11}$ C-methionine PET images. Injection of purified methioninase also produced PET images where tumor uptake was higher than that of infectious lesions.

Radiolabeling of 11C-sertraline by fast and easy loop method with [11C]CH3OTf

  • Lee, Hak Jeong;Jeong, Jae Min;Lee, Sang-Yoon;Ido, Tatsuo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.1
    • /
    • pp.32-37
    • /
    • 2017
  • Cis-(1S,4S)-4-(3,4-dichlorophenyl)-1,2,3,4-tertrahydro-N-methyl-1-naphthalenamine (sertraline) hydrochloride from among selective serotonin reuptake inhibitors (SSRIs) is a treatment of major depression. For the differential diagnosis by metabolizing serotonin in a patient with neurological disorders, the radiolabeled $^{11}C$-sertraline was developed for non-invasive positron emission tomography in living brain and use the evaluation of new drug for SSRIs. We release the results of a fast and easy radiolabeling method applied a one-step loop method with $[^{11}C]CH_3OTf$ for routine clinical applications of $^{11}C$-sertraline. 1 mg of a precursor for $^{11}C$-sertraline in 0.1 mL DMF and $5{\mu}L$ of 1N NaOH, were injected into the loop of semi-prep high-performance liquid chromatography (HPLC). $[^{11}C]CH_3OTf$ was passed through the loop at room temperature (RT). The $^{11}C$-sertraline was separated by the semi-preparative HPLC. $^{11}C$-sertraline was eluted at 28.0 min was collected and evaluated by analytical HPLC and mass spectrometer. The total radiolabeling efficiency of $^{11}C$-sertraline was $30.7{\pm}8.7%$. The specific activity was $64.8{\pm}51.4GBq/{\mu}mol$. The radiochemical and chemical purities were higher than 99%. The mass spectrum of the product showed m/z peaks at 307.1 (M+1), indicating the mass of sertraline. By the one-step loop method with $[^{11}C]CH_3OTf$, $^{11}C$-sertraline could be quickly and easily prepared for clinical application.

Comparative Enzymatic Hydrolysis of Bacillus amyloliquefaciens DS11 Phytase and Aspergillus ficuum Phytase in the Cannulated Pigs (Cannula를 장착한 돼지에서 Bacillus amyloliquefaciens DS11 Phytase와 Aspergillus ficuum Phytase의 역가 비교)

  • 장범수;박승춘;윤효인
    • Journal of Veterinary Clinics
    • /
    • v.18 no.1
    • /
    • pp.18-21
    • /
    • 2001
  • In this study, we assessed the efficacy of a novel B. amyloliquefacience DS11 phytase (DS11 phytase) and that of a commercial Aspergillus ficcum phytase (AF phytase) through their bioavailabilities of phytin-posphorus and -calcium in the diet using cannulated pigs. For the purpose of evaluating the efficacy of the phytases in pigs, we determined phosphorous concentrations from serum and feces, in addition to ingesta obtained from the cannula at the terminal ileum. As results, phosphorus concentration was lower in feces from DS11 group and BASF group by 17% and 10%, and higher in serum from the respective groups by 34% and 20%, as compared to the control group. Both phytases are evaluated to enhance phosphorus availability to the great extent. Calcium concentration of feces were lower in DS11 group and BASF group by 31% and 10%, than that in the control. Calcium concentration of serum was higher in DS11 phytase group by 4% but lower in AF phyase group by 3%, then that in the control group.

  • PDF

Fast and Secure Handoff Mechanism for Mobile IPv6 based on IEEE 802.11 (IEEE 802.11 기반의 고속의 안전한 Mobile IPv6 핸드오프 메커니즘)

  • Kang, Hyun-Sun;Park, Chang-Seop
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.2
    • /
    • pp.205-215
    • /
    • 2010
  • It is necessary to provide a fast and secure handover for seamless real-time multimedia services based on IEEE 802.11. In this paper, we propose FMIPv6 handoff protocol integrating L2/L3 layer based on IEEE 802.11 WLAN environment. In that, we propose a hierarchical key management scheme and authentication mechanism for protecting the handover signaling messages. The number of connections with AAA server is minimized for the fast handover. It is also compared and analyzed the handover cost with previous method.

Comparison Analysis of Packet Delay Model in IEEE 802.11 Wireless Network (IEEE 802.11 무선망에서의 패킷지연시간 모델 비교분석)

  • Lim, Seog-Ku
    • Journal of Digital Contents Society
    • /
    • v.9 no.4
    • /
    • pp.679-686
    • /
    • 2008
  • Wireless LAN(WLAN) is a rather mature communication technology connecting mobile terminals. IEEE 802.11 is a representative protocol among WLAN technologies. With the rising popularity of delay-sensitive real-time multimedia applications(video, voice and data) in IEEE 802.11 wireless LAN, it is important to study the MAC layer delay performance of WLANs. In this paper, performance for packet delay model that recently have been proposed schemes is analysed in wireless LAN and proved performance results via simulation.

  • PDF

RECOVERY OF FREOU-11 USED IN A PROCESSING SYSTEM OF TOBACCO EXPANSION (ABOUT COOLING AND COMPRESSION SYSTEM) (담배 팽화공정에 사용된 Freon-11의 회수 (냉각 및 압축 system에 관해서))

  • 김기환;유광근;주영석;최영현;김병구
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.7 no.2
    • /
    • pp.189-197
    • /
    • 1985
  • The purpose of this study is to improve the method and the apparatus for recovering freon-11 used in a process for increasing the filling capacity of tobacco. The first, the theoretical recovery rate of freon-11 was calculated from vapour pressure and thermodynamic properties of freon-11. The second, the usability of theoretical data was evaluated by the comparison between the theoretical data and the experimental data from the pilot plant. The result obtained under the present experiment condition was quite similar to the rate at 15kg/cm2 and 5$^{\circ}C$, but the theoretical data evaluated were 0.1 to 0.3% lower than the experimental data at 20 to 25kg/cm2 and 5$^{\circ}C$. The recovery rate of the cooling and the compression system was about 95% with freon-11 used in this system and that with freon-11 concentrate of waste gas was about 3 to 3.6% at 20 to 25kg/cm2 and 5$^{\circ}C$.

  • PDF

Deletion or Duplication Syndromes of Chromosome 22: Review

  • Kyung Ran Jun
    • Journal of Interdisciplinary Genomics
    • /
    • v.6 no.1
    • /
    • pp.1-5
    • /
    • 2024
  • Chromosome 22 is an acrocentric chromosome containing 500-600 genes, representing 1.5%-2% of the total DNA in cells. It was the first human chromosome to be fully sequenced by the Human Genome Project. Several syndromes involving the partial deletion or duplication of chromosome 22 are well descibed, including 22q11.2 deletion syndrome, 22q11.2 duplication syndrome, 22q11.2 distal deletion syndrome, Phelan-McDermid syndrome caused by a 22q13 deletion or pathogenic variant in SHANK3, and cat-eye syndrome caused by a 22 pter-q11 duplication. This review aims to provide concise information on the clinical characteristics of these syndromes. In particular, the similarities in features among these syndromes, genetic basis, and standard detection techniques are described, providing guidance for diagnosis and genetic counselling.