• Title/Summary/Keyword: 11.15 Earthquake

Search Result 58, Processing Time 0.023 seconds

Improvement of Post-earthquake Risk Assesment System for Damaged Buildings by Case Study on '11.15 Earthquake' (11.15 지진 사례를 통한 지진피해 시설물 위험도 평가 체계 개선)

  • Kang, Hyeong Gu;Yun, Nu-Ri;Kim, David;Lee, Jung Han;Kim, Hye Won;Oh, Keum Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.185-191
    • /
    • 2018
  • Post-earthquake risk assessment technique in Korea is developed in 2013 by National Disaster Management Research Institute, at the same time, related manual and standard regulation is distributed to every local government by National Emergency Management Agency. The objectives of this research are to investigate and evaluate the post-earthquake risk assessment of 9.12 Earthquake (M5.8, Gyeongju City, 2016) and 11.15 Earthquake (M5.4, Pohang City, 2017). To suggest and improve the assessment process of post-earthquake risk, first post-earthquake risk assessment method of advanced foreign countries including US, New Zealand and Japan are compared, and post-earthquake evaluation activities in 9.12 Earthquake and 11.15 Earthquake are analyzed. From the results, it is needed to expand the adapted building and structure types and strengthen the earthquake disaster response capacity of local government.

Comparative Analysis of Structural Damage Potentials Observed in the 9.12 Gyeongju and 11.15 Pohang Earthquakes (9.12 경주지진 및 11.15 포항지진의 구조손상 포텐셜 비교연구)

  • Lee, Cheol-Ho;Kim, Sung-Yong;Park, Ji-Hun;Kim, Dong-Kwan;Kim, Tae-Jin;Park, Kyoung-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.175-184
    • /
    • 2018
  • In this paper, comparative analysis of the 9.12 Gyeongju and 11.15 Pohang earthquakes was conducted in order to provide probable explanations and reasons for the damage observed in the 11.15 Pohang earthquake from both earthquake and structural engineering perspectives. The damage potentials like Arias intensity, effective peak ground acceleration, etc observed in the 11.15 Pohang earthquake were generally weaker than those of the 9.12 Gyeongju earthquake. However, in contrast to the high-frequency dominant nature of the 9.12 Gyeongju earthquake records, the spectral power of PHA2 record observed in the soft soil site was highly concentrated around 2Hz. The base shear around 2 Hz frequency was as high as 40% building weight. This frequency band is very close to the fundamental frequency of the piloti-type buildings severely damaged in the northern part of Pohang. Unfortunately, in addition to inherent vertical irregularity, most of the damaged piloti-type buildings had plan irregularity as well and were non-seismic. All these contributed to the fatal damage. Inelastic dynamic analysis indicated that PHA2 record demands system ductility capacity of 3.5 for a structure with a fundamental period of 0.5 sec and yield base shear strength of 10% building weight. The system ductility level of 3.5 seems very difficult to be achievable in non-seismic brittle piloti-type buildings. The soil profile of the PHA2 site was inversely estimated based on deconvolution technique and trial-error procedure with utilizing available records measured at several rock sites during the 11.15 Pohang earthquake. The soil profile estimated was very typical of soil class D, implying significant soil amplification in the 11.15 Pohang earthquake. The 11.15 Pohang earthquake gave us the expensive lesson that near-collapse damage to irregular and brittle buildings is highly possible when soil is soft and epicenter is close, although the earthquake magnitude is just minor to moderate (M 5+).

Seismic Damage to RC Low-rise Building Structures Having Irregularities at the Ground Story During the 15 November 2017 Pohang, Korea, Earthquake (2017.11.15. 포항 흥해지진의 저층 RC 비틀림 비정형 건축물의 피해 및 손상 특성)

  • Hwang, Kyung Ran;Lee, Han Seon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.103-111
    • /
    • 2018
  • This study examines the seismic failure of RC low-rise building structures having irregularities at the ground story during the 15 November 2017 Pohang, Korea, earthquake, $M_w=5.4$, which is the second strongest since the government began monitoring them in 1978 in South Korea. Some 2,000 private houses were damaged or destroyed in this earthquake. Particularly, serious damage to the piloti story of RC low-rise residential building structures of fewer than five stories was observed within 3 km of the epicenter with brittle shear failure of columns and walls due to severe torsional behavior. Buildings below six stories constructed before 2005 did not have to comply with seismic design requirements, so confinement detailing of columns and walls also led to inadequate performance. However, some buildings constructed after 2005 were damaged at the flexible side of the piloti story due to the high torsional irregularity. Based on these results, this study focuses on the problems of the seismic torsion design approach in current building codes.

A Study of Hypocentral Depth of Pohang Earthquake (포항 지진의 진원 깊이 연구)

  • Chung, Tae Woong;Lee, Youngmin;Iqbal, Muhammad Zafar;Jeong, Jina
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.2
    • /
    • pp.125-131
    • /
    • 2018
  • 2017 Pohang earthquake (M 5.4) was more disastrous than 2016 Gyeongju earthquake (M 5.8), partly because of its shallow focal depth. However, precise focal depth of Pohang earthquake is still controversial. Close crustal model showed 6 ~ 11.5 km in relocation depth, whereas other models showed almost surface range. Geothermal study indicated temperature of $300^{\circ}C$ at depth of 7.5 km. Related with observations of seismogenic layer, the focal depth of Pohang earthquake seems to be 7 km depth as obtained by close model.

Analysis of Coordinate Change about Domestic CORS by Earthquake (지진발생으로 인한 국내 상시관측소 좌표변화 분석)

  • Kim, Min-Gyu;Park, Joon-Kyu
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.3
    • /
    • pp.467-475
    • /
    • 2018
  • Recently earthquakes have been increasing worldwide, and the largest earthquake of 5.8 on the Richter scale occurred on September 12, 2016 in the Gyeongju area. After the earthquake, more than 200 aftershocks have occurred from January 2017 to December 2017. The largest earthquake in 2017 was a 4.3-magnitude earthquake near Pohang on November 15. In this study, we tried to analyze the coordinate change due to the earthquake using the data of the CORS(Continuously Operating Reference Station) in Korea. In order to analyze the change of coordinates due to the earthquake in Pohang area on November 15, 2017, data processing was performed by kinematic method. And from January 2017 to December 2017, observation data of 9 stations in Korea were analyzed by relative positioning method and the change of coordinates due to earthquake was analyzed. As a result of the study, it was possible to estimate the instantaneous coordinate change due to the earthquake through the kinematic positioning, and it was suggested that there is no change in the coordinates of the domestic CORS by the relative positioning results. After the 2017 Gyeongju earthquake, aftershocks continue to occur, and it is necessary to monitor the area continuously.

Response Characteristics of Site-specific using Aftershock Event (여진을 통해 살펴본 대상구간의 응답특성)

  • Ahn, Jae-Kwang;Cho, Seongheum;Jeon, Young-Soo;Lee, Duk Kee
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.8
    • /
    • pp.51-64
    • /
    • 2018
  • Korean peninsula is known to be far from the plate boundary and not to generate large-scale earthquakes. However, earthquakes recently occurred in Gyeongju (2016/09/12, $M_L=5.8$) and Pohang (2017/11/15, $M_L=5.4$). The interest in earthquake engineering has increased, and various studies are actively underway by recently events. However, the seismic station network in Korea is less dense than that of the western U.S., resulting in the lack of data for detailed analyses of earthquakes. Therefore, KMA (Korea Meteorological Administration) set up temporary seismic stations and recorded ground motions from aftershocks. In this study, characteristics of Pohang seismic propagation and generation of bedrock motion are analyzed through the aftershock ground motion records at both permanent and temporary stations, as well as through the collected geological structure and site information. As a result, the response at Mangcheon-Li shows evidences of basin effects from both geology structures and measured aftershock motions.

Seismic Response Analysis of Nuclear Power Plant Structures and Equipment due to the Pohang Earthquake (포항지진에 대한 원자력발전소 구조물 및 기기의 지진응답분석)

  • Eem, Seung-Hyun;Choi, In-Kil
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.113-119
    • /
    • 2018
  • The probabilistic seismic safety assessment is one of the methodology to evaluate the seismic safety of the nuclear power plants. The site characteristics of the nuclear power plant should be reflected when evaluating the seismic safety of the nuclear power plant. The Korea seismic characteristics are strong in high frequency region and may be different from NRC Regulatory Guide 1.60, which is the design spectrum of nuclear power plants. In this study, seismic response of a nuclear power plant structure by Pohang earthquake (2017.11.15. (KST)) is investigated. The Pohang earthquake measured at the Cheongsong seismic observation station (CHS) is scaled to the peak ground acceleration (PGA) of 0.2 g and the seismic acceleration time history curve corresponding to the design spectrum is created. A nuclear power plant of the containment building and the auxiliary buildings are modeled using OPENSEES to analyze the seismic response of the Pohang earthquake. The seismic behavior of the nuclear power plant due to the Pohang earthquake is investigated. And the seismic performances of the equipment of a nuclear power plant are evaluated by the HCLPF. As a result, the seismic safety evaluation of nuclear power plants should be evaluated based on site-specific characteristics of nuclear power plants.

Performance Evaluation of Rcentering Smart Damper by Pre-Compression of Polyurethane (폴리우레탄 선압축량에 따른 자동복원 스마트 감쇠장치의 일축반복하중에 대한 성능 평가)

  • Jang, Heemyung
    • Journal of Urban Science
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • As the magnitude and frequency of earthquakes increase in Korea, interest in earthquake damage reduction technology has increased. Therefore, research on vibration damping devices that directly respond to seismic loads is being actively researched. After an earthquake, damage or destruction of the device occurs due to the yield of materials, and thus it takes considerable cost and time for restoration and replacement. To supplement the problems of the existing earthquake damage reduction technology, a study was conducted on the recentering smart damper that can be used continuously after an earthquake. In this study, the recentering smart damper that can be restored to its original shape after load removal was developed using superelastic shape memory alloy, pre-compressed polyurethane. General steel was commonly applied to verify the seismic performance of the superelastic shape memory alloy, and the performance of the smart damper was verified according to the amount of polyurethane pre-compressed

The Abnormal Groundwater Changes as Potential Precursors of 2016 ML5.8 Gyeongju Earthquake in Korea (지하수위 이상 변동에 나타난 2016 ML5.8 경주 지진의 전조 가능성)

  • Lee, Hyun A;Hamm, Se-Yeong;Woo, Nam C.
    • Economic and Environmental Geology
    • /
    • v.51 no.4
    • /
    • pp.393-400
    • /
    • 2018
  • Despite some skeptical views on the possibility of earthquake prediction, observation and evaluation of precursory changes have been continued throughout the world. In Korea, the public concern on the earthquake prediction has been increased after 2016 $M_L5.8$ and 2017 $M_L5.4$ earthquakes occurred in Gyeongju and Pohang, the southeastern part in Korea, respectively. In this study, the abnormal increase of groundwater level was observed before the 2016 $M_L5.8$ Gyeongju earthquake in a borehole located in 52 km away from the epicenter. The well was installed in the Yangsan fault zone, and equipped for the earthquake surveillance. The abnormal change in the well would seem to be a precursor, considering the hydrogeological condition and the observations from previous studies. It is necessary to set up a specialized council to support and evaluate the earthquake prediction and related researches for the preparation of future earthquake hazards.

Ground-motion prediction equation for South Korea based on recent earthquake records

  • Jeong, Ki-Hyun;Lee, Han-Seon
    • Earthquakes and Structures
    • /
    • v.15 no.1
    • /
    • pp.29-44
    • /
    • 2018
  • A ground-motion prediction equation (GMPE) for the Korean Peninsula, especially for South Korea, is developed based on synthetic ground motions generated using a ground motion model derived from instrumental records from 11 recent earthquakes of $M_L$>4.5 in Korea, including the Gyeongju earthquake of Sept. 12. 2016 ($M_L$5.8). PSAs of one standard deviation from the developed GMPE with $M_W$ 6.5 at hypocentral distances of 15 km and 25 km are compared to the design spectrum (soil condition, $S_B$) of the Korean Building Code 2016 (KBC), indicating that: (1) PSAs at short periods around 0.2 sec can be 1.5 times larger than the corresponding KBC PSA, and (2) SD's at periods longer than 2 sec do not exceed 8 cm. Although this comparison of the design spectrum with those of the GMPE developed herein intends to identify the characteristics of the scenario earthquake in a lower-seismicity region such as South Korea, it does not mean that the current design spectrum should be modified accordingly. To develop a design spectrum compatible with the Korean Peninsula, more systematic research using probabilistic seismic hazard analysis is necessary in the future.