• Title/Summary/Keyword: 100미터

Search Result 331, Processing Time 0.04 seconds

Syllable Recognition of HMM using Segment Dimension Compression (세그먼트 차원압축을 이용한 HMM의 음절인식)

  • Kim, Joo-Sung;Lee, Yang-Woo;Hur, Kang-In;Ahn, Jum-Young
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.40-48
    • /
    • 1996
  • In this paper, a 40 dimensional segment vector with 4 frame and 7 frame width in every monosyllable interval was compressed into a 10, 14, 20 dimensional vector using K-L expansion and neural networks, and these was used to speech recognition feature parameter for CHMM. And we also compared them with CHMM added as feature parameter to the discrete duration time, the regression coefficients and the mixture distribution. In recognition test at 100 monosyllable, recognition rates of CHMM +${\bigtriangleup}$MCEP, CHMM +MIX and CHMM +DD respectively improve 1.4%, 2.36% and 2.78% over 85.19% of CHMM. And those using vector compressed by K-L expansion are less than MCEP + ${\bigtriangleup}$MCEP but those using K-L + MCEP, K-L + ${\bigtriangleup}$MCEP are almost same. Neural networks reflect more the speech dynamic variety than K-L expansion because they use the sigmoid function for the non-linear transform. Recognition rates using vector compressed by neural networks are higher than those using of K-L expansion and other methods.

  • PDF

Petrochemical Plant Safety Management System based on Wireless Transmitter (무선 트랜스미터 기반의 석유화학 플랜트 안전관리 시스템)

  • Kang, Sung-Min;Park, Soo-Yeol;Yeo, Keum-Soo;Park, Jae-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.88-94
    • /
    • 2015
  • Large-scale petrochemical and power plants has increased demanting wireless technology for continuous monitoring. However, the current USN technologies, such as ZigBee and Bluetooth, are lackof reliability and security. Therefore, there is a strong need to apply a new wireless technology standard of the ISA. In this study, a petrochemicalplant safety management system based on the ISA wireless transmitter isdeveloped. ISA100.11a communication module and LTE communication module equippedwith an explosion-proof wireless transmitter are developed. A petrochemicalplant safety management system is built based on the IoT technologies. Thedeveloped system is verified through a wide range of testing and thus, on-siteapplicability is proved.

Evaluation of Clinical Application Model of Optimized Parameter through Analysis of Stability of Radiation Output and Image Quality when Exposure Time Change of Digital Radiography (DR) (디지털 방사선 시스템(DR)의 조사시간 변화 시 방사선 출력과 영상 화질의 안정성 분석을 통한 최적화된 파라미터의 임상 적용 모델 평가)

  • Hwang, Jun-Ho;Choi, Ji-An;Kim, Hyun-Soo;Lee, Kyung-Bae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.139-148
    • /
    • 2020
  • The purpose of this study is to propose a method to optimize the performance of Digital Radiography (DR) by analyzing the effect of exposure time change on the stability of radiation output and image quality. The experimental method was used to change the exposure time to 50 msec, 100 msec, 200 msec, and 400 msec so that the Percentage Average Error (PAE), Time-to-Radiation Dose Curve, Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR) and theses analysis were performed to evaluate the normal operation of parameters, radiation output and image quality. As a result, all the parameters used in the experiment showed the Percentage Average Error in the normal range, and the shorter the exposure time, the stability of radiation output and image quality decrease. In conclusion, it was found that the performance of Digital Radiography can be optimized when stable radiation output and image quality are applied by applying 100 msec ~ 200 msec exposure time.

Retrospective Analysis of Cytopathology using Gray Level Co-occurrence Matrix Algorithm for Thyroid Malignant Nodules in the Ultrasound Imaging (갑상샘 악성결절의 초음파영상에서 GLCM 알고리즘을 이용한 세포병리 진단의 후향적 분석)

  • Kim, Yeong-Ju;Lee, Jin-Soo;Kang, Se-Sik;Kim, Changsoo
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.237-243
    • /
    • 2017
  • This study evaluated the applicability of computer-aided diagnosis by retrospective analysis of GLCM algorithm based on cytopathological diagnosis of normal and malignant nodules in thyroid ultrasound images. In the experiment, the recognition rate and ROC curve of thyroid malignant nodule were analyzed using 6 parameters of GLCM algorithm. Experimental results showed 97% energy, 93% contrast, 92% correlation, 92% homogeneity, 100% entropy and 100% variance. Statistical analysis showed that the area under the curve of each parameter was more than 0.947 (p = 0.001) in the ROC curve, which was significant in the recognition of thyroid malignant nodules. In the GLCM, the cut-off value of each parameter can be used to predict the disease through analysis of quantitative computer-aided diagnosis.

CIGS 박막 태양전지에서의 온도 스트레스에 의한 전기적 특성 및 효율 변화 분석

  • Kim, Sun-Gon;Choe, Byeong-Deok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.327.2-327.2
    • /
    • 2014
  • CIGS박막 태양전지의 온도에 의한 효율과 전기적 특성 변화를 알아보기 위해 $25^{\circ}C$, $50^{\circ}C$, $100^{\circ}C$, $150^{\circ}C$, $200^{\circ}C$에서 각각 100시간을 노출시킨 후 전기적인 특성들을 측정하여 초기 값들과 비교하였다. 태양전지의 온도 스트레스에 의한 특성 및 파라미터들의 변화들을 확인하기 위해 Light I-V와 Minority Carrier의 Lifetime을 측정하여 비교 분석하였다. 실험에 사용한 소자의 초기 파라미터들은 $25^{\circ}C$에서 측정하였고, 단락전류 11mA, 개방전압 0.64V, 곡선인자 60.49%, Lifetime 10.7s 효율 9.17%이다. 각 온도별 노출에 대해 CIGS박막 태양전지의 효율은 $50^{\circ}C$, $100^{\circ}C$에서는 초기 값과 비슷하였고, $150^{\circ}C$, $200^{\circ}C$에서 초기 값 대비 54%, 84% 감소 특성을 보였다. 단락전류는 $50^{\circ}C$, $100^{\circ}C$, $150^{\circ}C$에서는 크게 변화하는 모습이 나타나지 않았고 $200^{\circ}C$에서 63% 감소하였다. 개방전압, 곡선인자, Lifetime은 효율과 마찬가지로 $150^{\circ}C$, $200^{\circ}C$에서 감소하는 모습이 나타났다. $150^{\circ}C$, $200^{\circ}C$에서 개방전압이 9.3%, 18.7%, 곡선인자는 45.8%, 56.3%정도 감소하였다. Lifetime은 64.4%, 80.1%정도 감소하였다. 이 실험을 통해 개방전압과 곡선인자, Minority Carrier의 Lifetime이 일정 온도부터 온도의 영향을 받아 감소하고, 그 영향으로 효율이 감소하게 되는 것을 확인하였다.

  • PDF

Development of the laser measurement system for the wide output power range (광범위 출력 측정이 가능한 레이저 계측장치 개발)

  • Hwang Daeseok;Lee Young-Woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.8
    • /
    • pp.1799-1804
    • /
    • 2005
  • We have developed and estimated the measurement system of $CO_2$ and Nd:YAG laser power of wide range. The absorber is made of gold-plated copper cavity. The calibration heater is using a manganin(CuMn12Ni) coil, and output power is measured by using or resistance bridge with composed manganin and copper coil. Developed system can measure 5${\~}$1000W laser output power range. Calibration factors are 489.13J/mV at 100W and 497.04(J/mV) at 500W. correction factors are 0.99 at 100W and 1.006 at 500W.

Measurement and Evaluation of Form Accuracy of Large Optical Surfaces (대구경 광학표면의 형상정밀도 측정 및 평가)

  • 김승우
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.6-7
    • /
    • 2002
  • 대구경 광학계는 일반적으로 직경이 100 밀리미터 이상 1 미터에 이르는 거울이나 렌즈를 총칭한다. 이러한 대구경 광학계의 수요는 과거에는 천문 관측용 광학 부품에 주로 한정되었으나, 근래에 들어 인공위성의 지상 또는 우주 관측의 수요가 늘면서 다양한 형상의 대구경 광학계의 생산이 증대되고 있다. 또한 최근 들어서는 전자 및 디스플레이 산업에서 복잡한 형상 패턴의 노광 방식에 의한 기술의 사용이 증대되면서 노광기의 핵심부품인 대구경 광학계의 소비자 산업의 수요도 점차 확대되어 가고 있다. (중략)

  • PDF

Speed Control of BLDC Motor without Speed Sensor (속도센서 없는 BLDC 모터의 속도 제어)

  • 강태삼;최치영
    • Proceedings of the KAIS Fall Conference
    • /
    • 2000.10a
    • /
    • pp.104-108
    • /
    • 2000
  • 본 논문에서는 BLDC 모터에서 속도 센서를 사용하지 않고 홀센서의 출력만을 이용하여 속도 제어를 수행하였다. 모터는 100W급을 이용하였으며, 부하는 팬을 이용하였다. 속도 계측은 BLDC 모터에 불어 있는 3개의 홀센서 출력을 이용하였다. 홀센서 간에 간격이 불균일하므로 3개의 홀 센서를 구분하여 각각이 한 바퀴 회전하는데 까지의 시간을 측정하여 속도를 측정하였다. ARMAX 모델에 기초하여 전체 시스템의 파라미터를 구하였다. 구해진 파라미터에 PID 제어기를 구성하여 속도 제어를 수행하였다. 속도 제어 결과 0.1% 오차 미만으로 속도가 원활하게 유지되는 것을 확인하였다.

Implementation of the simulated-Inductance with a Phase Paramenter Control Circuit (위상 파라미터 제어에 의한 의사 인덕턴스의 구성)

  • 최태호;김덕규
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.2
    • /
    • pp.29-34
    • /
    • 1983
  • A simulated inductance, with a phase parameter control circuit containing only two resistors and one operational amplifier, is realized as a two terminal network. Analytical results of the proposed circuit avow that we can realize a simulated inductance for constant inductance value, and experimental results confirm the theoretical predictions. Error of maximum 4%, between theoretical and experimental results of equivalent inductance, has been observed over a wide range of frequencies up to about 100 KHz.

  • PDF

ATSC 3.0 기반 모바일HD 물리계층 필드테스트 결과: 제주테크노파크 100W 실험국과 제주시내 이동측정을 위주로

  • Jeon, Seong-Ho;Im, Bo-Mi;Park, Seong-Ik;Lee, Jae-Gwon;Jang, Jin-Yeong;Lee, Gwon-Ik
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2017.11a
    • /
    • pp.28-31
    • /
    • 2017
  • 지상파 방송 3사(KBS/MBC/SBS) 수도권 본방송 파라미터와 동일하게 설정한 제주테크노파크 100W 실험국에서 ATSC 3.0 신호를 발사한 뒤, 제주시내 일대를 이동하면서 양시청 여부는 물론 실측값을 수집하였다. 결론적으로, 현재 전송파라미터 구성으로 송수신 정합에 이상 없이, 기술적인 관점에서 수도권 모바일HD 본방송이 가능함을 검증하였고, 커버리지 산출에 필수적인 물리계층 성능 지표인 ESR5에 대한 기준값, 즉 변조오류율(MER) 기준으로 11.3dB, 수신 신호 세기(Level) 기준으로 -85.0dBm 정도임을 도출하였다.

  • PDF