• Title/Summary/Keyword: 1-dimensional heat analysis

Search Result 334, Processing Time 0.031 seconds

One-dimensional Numerical Analysis of the Effect of Seawater Feed Rate on Multi-effect Solar Stills (태양열 담수기 다중효용부의 해수 공급유량에 관한 1차원 수치해석)

  • Lim, Byung-Ju;Yu, Sang-Seok;Park, Change-Dae;Chung, Kyung-Yul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.7
    • /
    • pp.477-484
    • /
    • 2016
  • In a multi-effect solar distiller, a feeding rate of seawater to each effect should be decreased as the effect number is increased. In previous studies, the feed rate of seawater was not reduced evenly between the effects, which is unreasonable, since the thermal energy input of each effect decreases by the same amount. In this work, numerical analysis was carried out in order to elucidate this discrepancy. The results showed that the amount of distillates produced was almost the same for both evenly and unevenly reduced flow rates between the effects. Optimum feed rates of seawater with various energy inputs from exhaust gas heat exchanger were also obtained. The results showed that the optimum feed rate of the first effect increased linearly or reached a steady state depending on the heat flux.

A Study on the Thermal Analysis of Induction Hooting Cooker with Finite Element Method (유한요소법에 의한 IH-Cooker의 열해석에 관한 연구)

  • Oh, Hong-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.1
    • /
    • pp.80-85
    • /
    • 2003
  • Recently, induction heating cooker(IH-Cooker) is very interested for high efficiency, the quickness of heating time and the convenient regulation of heating spot. In this paper, we proposed the magneto-thermal analysis of an induction heating cooker(IH-Cooker) as an efficient design, and analyzed the magnetic fold intensity inside the axisymmetric shaped cooker using three-dimensional axisymmetric finite element method(Flux2D) and the effectual heat source was obtained by ohmic losses from eddy currents induced in the cooker. Also, we presented the temperature characteristics of the IH-Cooker according to input frequency and relative permeability in stainless parts and in aluminum parts.

Characteristics Analysis of a Small Scale Persistent Current Switch System by using Coated Conductor (Coated Conductor를 이용한 소용량 영구전류스위치 시스템의 특성 해석)

  • Kim, Yeong-Sik;Yoon, Yong-Soo;Yang, Seong-Eun;Park, Dong-Keun;Ahn, Min-Cheol;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.47-52
    • /
    • 2007
  • This paper presents characteristics analysis of persistent current switch(PCS) system on a small scale by using YBCO coated conductor(CC). A high temperature superconductor(HTS) PCS system mainly consists of a PCS, a HTS magnet load and a magnet power supply(MPS). To design the optimal heater triggering switch. the three-dimensional heat conduction model was analyzed by finite element method(FEM). The electrical equivalent model considering the n-value of CC was applied to analyze current decay during persistent current mode. In the experiment and simulation, the heater was applied with a current of 0.43A and the current was ramped up to 10A and 20A with 0.2A/s. Finally, experimental results of the HTS PCS system have been compared with the theoretical results. It has been concluded that flux creep can not influence the results because the operating current was 40% of critical current and optimal sequential operation of the PCS system is indispensable to enhance its performance.

Dynamic analysis of a functionally graded tapered rotating shaft under thermal load via differential quadrature finite elements method

  • Fethi, Hadjoui;Ahmed, Saimi;Ismail, Bensaid;Abdelhamid, Hadjoui
    • Advances in aircraft and spacecraft science
    • /
    • v.10 no.1
    • /
    • pp.19-49
    • /
    • 2023
  • The present study proposes a theoretical and numerical investigation on the dynamic response behaviour of a functional graded (FG) ceramic-metal tapered rotor shaft system, by the differential quadrature finite elements method (DQFEM) to identify the natural frequencies for modelling and analysis of the structure with suitable validations. The purpose of this paper is to explore the influence of heat gradients on the natural frequency of rotation of FG shafts via three-dimensional solid elements, as well as a theoretical examination using the Timoshenko beam mode, which took into account the gyroscopic effect and rotational inertia. The functionally graded material's distribution is described by two distribution laws: the power law and the exponential law. To simulate varied thermal conditions, radial temperature distributions are obtained using the nonlinear temperature distribution (NLTD) and exponential temperature distribution (ETD) approaches. This work deals with the results of the effect on the fundamental frequencies of different material's laws gradation and temperature gradients distributions. Attempts are conducted to identify adequate explanations for the behaviours based on material characteristics. The effect of taper angle and material distribution on the dynamic behaviour of the FG conical rotor system is discussed.

Identification of Proteins Affected by Iron in Saccharomyces cerevisiae Using Proteome Analysis

  • Lieu Hae-Youn;Song Hyung-Seok;Yang Seung-Nam;Kim Jae-Hwan;Kim Hyun-Joong;Park Young-Doo;Park Cheon-Seok;Kim Hae-Yeong
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.6
    • /
    • pp.946-951
    • /
    • 2006
  • To study the effect of iron on Saccharomyces cerevisiae, whole-cell proteins of Saccharomyces cerevisiae were extracted and subjected to two-dimensional polyacrylamide gel electrophoresis (2D-PAGE), and differentially expressed proteins were identified. The proteins separated were further identified by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry and were compared with a protein database. Of more than 300 spots separated by molecular weight and isoelectric points, 27 differentially expressed spots were identified. Ten proteins were found to be differentially expressed at high iron concentration. Triosephosphate isomerase (TPI), YDR533C hypothetical protein, superoxide dismutase (SOD), 60 kDa heat-shock protein (HSP60), pyruvate dehydrogenase beta subunit 1 (PDB1), and old yellow enzyme 2 (OYE2) were upregulated, whereas thiol-specific antioxidant (TSA), regulatory particle non-ATPase subunit 8 (RPN8), thiol-specific peroxiredoxin 1 (AHP1), and fructose-1, 6-bisphosphate adolase (FBA) were downregulated by iron. Based on the result, we propose that SOD upregulated by iron would protect the yeast from oxidative stress by iron, and that TSA downregulated by iron would render cells hypersensitive to oxidative stress.

Improvement of the subcooled boiling model using a new net vapor generation correlation inferred from artificial neural networks to predict the void fraction profiles in the vertical channel

  • Tae Beom Lee ;Yong Hoon Jeong
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4776-4797
    • /
    • 2022
  • In the one-dimensional thermal-hydraulic (TH) codes, a subcooled boiling model to predict the void fraction profiles in a vertical channel consists of wall heat flux partitioning, the vapor condensation rate, the bubbly-to-slug flow transition criterion, and drift-flux models. Model performance has been investigated in detail, and necessary refinements have been incorporated into the Safety and Performance Analysis Code (SPACE) developed by the Korean nuclear industry for the safety analysis of pressurized water reactors (PWRs). The necessary refinements to models related to pumping factor, net vapor generation (NVG), vapor condensation, and drift-flux velocity were investigated in this study. In particular, a new NVG empirical correlation was also developed using artificial neural network (ANN) techniques. Simulations of a series of subcooled flow boiling experiments at pressures ranging from 1 to 149.9 bar were performed with the refined SPACE code, and reasonable agreement with the experimental data for the void fraction in the vertical channel was obtained. From the root-mean-square (RMS) error analysis for the predicted void fraction in the subcooled boiling region, the results with the refined SPACE code produce the best predictions for the entire pressure range compared to those using the original SPACE and RELAP5 codes.

Modeling of Water Temperature in the Downstream of Yongdam Reservoir using 1-D Dynamic Water Quality Simulation Model (1차원 동적수질모형을 활용한 용담댐 하류하천의 수온변동 모의)

  • Noh, Joonwoo;Kim, Sang-Ho;Shin, Jae-Ki
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.2
    • /
    • pp.356-364
    • /
    • 2010
  • The chemical and biological reaction of the aquatic organism is closely related with temperature variation and water temperature is one of the most important factors that should be considered in establishing sustainable reservoir operation scheme to minimize adverse environmental impacts related with dam construction. This paper investigates temperature variation in the downstream of Yongdam Reservoir using sampled data collected from total 8 temperature monitoring stations placed along the main river and the major tributaries. Using KoRiv1, 1-dimensional dynamic water quality simulation model, temperature variation in the downstream of Yongdam Reservoir has been simulated. The simulated results were compared with sampled data collected from May 15 to August 1 2008 by applying two different temperature modeling schemes, equilibrium temperature and full heat budget method. From the result of statistical analysis, seasonal temperature variation has been simulated by applying the equilibrium temperature scheme for comparison of the difference between the reservoir operation and the natural conditions.

Predictive Analysis on Explosive Performance and Sensitivity of 1-Substituted Trinitroimidazoles (트리나이트로이미다졸 치환체들의 화약성능 및 감도 예측 분석)

  • Jeon, Yeongjin;Kim, Hyoun-Soo;Kim, Jin Seuk;Cho, Soo Gyeong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.543-550
    • /
    • 2017
  • Various chemical properties including density and heat of formation of 1-substitued trinitroimidazoles (TNIs) were estimated by using density functional theory (DFT). Using chemical properties estimated by DFT, explosive performance and sensitivity of 1-substitued TNIs were analyzed by following the ADD Method-1 procedure. The results were displayed on two-dimensional performance-sensitivity plot, and were compared with those of explosive molecules commonly used in many military systems. Different 1-substituents of TNI made that both explosive performance and impact sensitivity were changed significantly. Methyl substituted TNI became moderately insensitive and slightly less powerful. Amino, fluoro, picryl, and difluoroamino substituted TNIs were highly powerful like RDX and HMX, but greatly sensitive. Nitro substituted TNI was predicted to be extremely sensitive to be handled as a secondary explosive.

Horizontal 2-D Finite Element Model for Analysis of Mixing Transport of Heat Pollutant (열오염 혼합 거동 해석을 위한 수평 2차원 유한요소모형)

  • Seo, Il Won;Choi, Hwang Jeong;Song, Chang Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.6B
    • /
    • pp.507-514
    • /
    • 2011
  • A numerical model has been developed by employing a finite element method to simulate the depth-averaged 2-D dispersion of the heat pollutant, which is an important pollutant material in natural streams. Among the finite element methods, the Streamline Upwind/Petrov Galerkin (SUPG) method was applied. Also both linear and quadratic elements can be applied so that irregular river boundaries can be easily represented. To show the movement of heat pollutants, the reaction term describing heat transfer was represented as an equation in which sink/source term is proportional to the difference between the equilibrium temperature and water surface temperature. The equation was expressed so that the water surface temperature changes according to the temperature transfer coefficient and the equilibrium temperature. For the calibration of the model developed, analytic and numerical results from a case of rectangular channel with full width continuous injection have been compared in a steady state. The comparisons showed that the numerical results were in good agreement with analytical solutions. The application site was selected from the downstream of Paldang dam to Jamsil submerged weir, and overall length of this site is about 22.5 km. The change of water temperature caused by the discharge from the Guri sewage treatment plant has been simulated, and results were similar to the observed data. Overall it is concluded that the developed model can represent the water temperature changes due to heat transport accurately. But the verification using observed data will further enhance the validity of the model.

Performance of Refrigerated Display Cabinets in accordance with the Supply Air Jet Condition (급기제트 조건에 따른 냉동용 전시케이스의 성능)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.80-86
    • /
    • 2011
  • Vertical open display cabinets are widely used in shopping mall, supermarkets, retail stores. Maintaining the temperature of foods in the display cabinet is vitally important to retailers to ensure optimal food quality and safety. The purpose of this study is to reduce the infiltration of air and heat loss from ambient space to display cabinet. The three-dimensional Computational Fluid Dynamics(CFD) simulation is used for the analysis of air flow patterns and temperature distribution in refrigerated display cabinets. Under several operating conditions which vary both the inner and outer jet velocities in the range from 0.3 to 1.1 m/s, simulations were carried out. This paper presents a performance of display cabinets with single jet and double jet. The energy consumption due to thermal entrainment ratio is plotted with varying Re. It was found that the double jet system is better than single jet system in terms of temperature distribution and energy saving.