• Title/Summary/Keyword: 1-dimensional heat analysis

Search Result 333, Processing Time 0.029 seconds

Analysis of Solidification Process Around a Vertical Tube Considering Density Change and Natural Convection (수직원관 주위에서 밀도차와 자연대류를 고려한 응고과정 해석)

  • 김무근;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.142-155
    • /
    • 1992
  • Numerical analysis is performed for the unsteady axisymmetric two dimensional phase change problem of freezing of water around a vertical tube. Heat conduction in the tube wall and solid phase, natural convection in liquid phase and volume expansion caused by density difference between solid and liquid phases are included in the numerical analysis. Existing correlation is used for estimating density-temperature relation of water, and the effect of volume expansion is reflected as fluid velocity at the interface and the free surface. As pure water has maximum density at 4.deg. C, it is found that there exists an initial temperature at which the flow direction reverses near the interface and by this effect the slope of interface becomes reversed depending on the initial temperature of water. By considering natural convection and solid-liquid density difference in the calculation, their effects on phase change process are studied and the effects of various parameters are also studied quantitatively.

Noise Reduction of PDP TV Using Multi-dimensional Spectral Analysis Method (다차원 스펙트럼 해석법을 이용한 PDP TV의 저소음화)

  • Yang, In-Hyung;Jeong, Jae-Eun;Kwak, Hyung-Taek;Oh, Jae-Eung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.1
    • /
    • pp.81-88
    • /
    • 2011
  • The method is introduced for estimating the noise source contribution on the noise of PDP TV in a multiple-input system where the input sources may be coherent with each other. By the coherence function method, it is found that the biggest part of the noise source in the PDP TV noise is generated by the PCB boards which consume high power and produce high heat. This analysis is modeled as three-input/single-output system because the noise is generated by three main boards, X-board, Y-board, SMPS that are located close to each other. The coherence function method is proved to be useful tool for identifying of noise source. In this study, Transfer Path Analysis using MDSA is implemented to determine the quantitative noise contribution of each board for PDP TV with the rear case closed and with the rear case open. And the possibility of noise reduction is confirmed through the experimental method that isolates the most contributing board by adding sound-absorbing materials to it.

Parametric Study of an Integrated Steam Methane Reformer with Top-Fired Combustor (통합 수증기 개질 시스템의 작동 조건에 대한 수치적 연구)

  • Noh, Jung-Hun;Jung, Hye-Mi;Kim, Donghee;Um, Sukkee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.156.1-156.1
    • /
    • 2011
  • It is of great importance to predict operating parameter characteristics of an integrated fuel processor by the increased life-time and system performance. In this study, computational analysis is performed to gain fundamental insights on transport phenomena and chemical reactions in reformer which consists of preheating, steam reforming, and water gas shift reaction beds. Also, a top-fired burner locates inside of the reforming system. The combustor is providing thermal energy necessary for the steam reforming bed which is a endothermic catalytic reactor. Two-dimensional numerical model of the integrated fuel processing system is introduced for the analysis of heat and mass transport phenomena as well as surface kinetics and catalytic process. A kinetic model was developed and then computational results were compared with the experimental data available in the literature. Subsequently, parameter study using the validated steam methane reforming model was conducted by considering operating parameters, i.e. steam to carbon ratio and temperature.

  • PDF

Evaluation of Structural Integrity and Cooling Performance of 4250 kVA Power Transformer with ONAN Mode (ONAN 모드 4250kVA 변압기의 구조 건전성과 냉각 성능의 평가)

  • Yang, Chaofan;Kim, Seongik;Cho, Jong-Rae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.7
    • /
    • pp.48-57
    • /
    • 2021
  • The main research content of this paper is to evaluate the structural integrity and the cooling performance of 4250 kVA power transformer with ONAN(Oil Natural and Air Natural) mode. The dynamic analysis is used to verify the structural safety of the transformer by seismic loading. The transformer structure is simplified and NX software is used to build a three-dimensional model, and ANSYS commercial software is used to calculate the stress and deformation by applying corresponding load. The analysis result was evaluated whether it satisfies the design requirements according to the IEEE Std 693 standard. In terms of thermal analysis to evaluate the cooling performance, the thermal physical model is used to calculate the heat exchange between the radiator and the tank in the steady state, and the result is input into the Fluent software to calculate the internal temperature field of the transformer tank, which reduces the calculation cost of thermal fluid. Comparing the simulated hot spot temperature and top oil temperature of the transformer with the calculation results of the IEC60076 classic model, it is found that the error is only 1.9%.

Development of a Computer Program for Thermal Sizing of a Copper Bonded Steam Generator (구리밀봉 증기발생기의 열적크기 계산을 위한 프로그램 개발)

  • 김의광;김연식;어재혁;김성오;백병준
    • Journal of Energy Engineering
    • /
    • v.12 no.2
    • /
    • pp.84-92
    • /
    • 2003
  • A one-dimensional thermal-hydraulic analysis computer program is developed for thermal sizing of a copper bonded steam generator. It is assumed that the conduction heat transfer of copper region between the hot side and the cold side tube is one-dimensional and its thermal resistance is derived as a function of a tube pitch. The flow regions of the water/steam side are divided into four regions: subcooled, saturated, film boiling, and super-heated. The number of tube selected ranges from 250 to 3500 and the pitch to tube diameter (P/D) ratios are 1.4, 1.6 and 1.8 for the parametric study calculation. The calculation results showed that when the number of tube was 2500, the length of the heating tube was about 12 m and the outside diameter of the steam generator was about 3 m. If the P/D ratio increases, the thermal resistance of copper component also increases, however the length of the heating tube is not so much increased.

A Study on the Distribution and Time Dependent Change of Wood Temperature by Solar Radiation

  • Xu, Hui Lan;Kang, Wook;Chung, Woo Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.141-147
    • /
    • 2009
  • The fluctuation of physical properties in wood or wood composites is an important subject when the materials in building and construction. Sorption and desorption occur in wood when exposed to the open air, and the temperature distribution in wood can fluctuate as a result of changes in environmental temperature, solar radiation, humidity, and wind velocity. In this study, the temperature difference and fluctuation caused by outdoor environment among different wood species were analyzed using a numerical method. The effect on the process of heat transfer in wood caused by environmental factors was investigated using 1-dimensional partial differential equation with real boundary and initial conditions. The experimental data have been used to check the accuracy of programming code. Through analysis, it was found out that density and moisture content have a negative effect on thermal diffusivity of wood.

Natural Convection from a Horisontal Conducting Tube with One Vertical Axial Fin. (단일수직(單一垂直)한 축방향(軸方向)의 핀을 가진 수평전도관(水平傳導管)으로 부터의 자연대류(自然對流))

  • Chung, H.S.;Kwon, S.S.
    • Solar Energy
    • /
    • v.6 no.1
    • /
    • pp.60-69
    • /
    • 1986
  • Two-dimensional finite difference numerical analysis is used to study conjugate natural convection heat transfer from a horizontal conducting tube with one vertical axial fin. By increasing dimensionless fin length ($L_F$), the mean total Nusselt number of the upward fin is slightly less than that of the downward fin at $L_F\;{\le}\;0.18$ and is higher than that of the downward fin at $L_F\;>\;0.18$. However comparing the upward fin and the downward fin with the no fin, the mean total Nusselt numbers of downward fin and upward fin at $L_F=0.30$ are increased approximately 4.01% and 5.51%, respectively. As Rayleigh number, Prandtl number and Biot number increase, the mean total and the mean tube Nusselt numbers are increased, but as wall thickness increases, the mean total and the mean tube Nusselt numbers are decreased. As the fin conduction parameter increases, the mean total Nusselt number is slightly increased because of increasing the mean fin Nusselt number.

  • PDF

Application of One-Dimensional Heat Transfer Models for Performance Prediction of a Thermodiode (열다이오드의 열전달 성능 예측을 위한 일차원 모델적용 연구)

  • Chun, Won-Gee;Kang, Yong-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.77-87
    • /
    • 2002
  • 그 열흐름의 방향이 인위적으로 조절 가능한 열다이오드 시스템에 관하여 일차원적 열전달 모델을 통하여 시스템의 열성능을 분석하였다. 열다이오드 시스템은 다수의 폐회로 유체 순환 루프로 구성되었으며 루프의 양단은 각각 태양열 흡열판과 방열판에 부착되었다. 한편, 열흐름의 방향 조절을 위하여 루프를 구성하는 튜브재의 연결 부위는 회전 가능한 조인트로 연결하였으며 열매체포는 물을 사용하였다. 본 연구에서는 열다이오드 시스템에 대하여 간단한 1차원 모델을 이용하여 시스템의 열성능을 평가하였으며 아울러 실측 결과와의 비교를 통하여 본 모델의 적용을 통한 시스템의 장기 예측에 대한 가능성을 확인하였다.

Study on simultaneous heat and mass transfer during the physical vapor transport of Hg2Br2 under ㎍ conditions

  • Kim, Geug Tae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.3
    • /
    • pp.107-114
    • /
    • 2019
  • A computational analysis has been carried out to get a thorough and full understanding on the effects of convective process parameters on double-diffusive convection during the growth of mercurous bromide ($Hg_2Br_2$) crystals on earth and under ${\mu}g$ conditions. The dimensional maximum magnitude of velocity vector, ${\mid}U{\mid}_{max}$ decreases much drasticlly near Ar = 1, and, then since Ar = 2, decreases. The ${\mu}g$ conditions less than $10^{-2}g$ make the effect of double-diffusion convection much reduced so that adequate advective-diffusion mass transfer could be obtained.

Numerical analysis of solar pond with insulation layer (단열층을 가지는 솔라 폰드의 수치해석)

  • Yu, Jik-Su;Mun, Soo-Beom
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.264-269
    • /
    • 2016
  • This paper reports a fundamental study of temperature characteristics of a solar pond with an insulation layer. Further, these characteristics were compared with those of a solar pond without the insulation layer. The governing equation was discretized via finite difference method. The governing equations are two-dimensional unsteady-state second-order partial differential equations. The conclusions of the study are as follows: 1) If the depth of the solar pond was increased, the desired effect of increase in temperature was not produced because the amount of solar insolation received by the bottom of the solar pond decreased. 2) As the temperature of the soil during winter is higher than the temperature of the water in a solar pond, heat was transferred from the soil to the solar pond. 3) For the case of the solar pond with insulation layer, it was estimated that the dependence rate of solar energy was 83.3% and that of the boiler was 16.7%.