• Title/Summary/Keyword: 1-Wire

Search Result 2,256, Processing Time 0.032 seconds

Characteristics of AC loss of Hybrid Multi-Stacking with HTS Wires in External Magnetic Field (고온초전도 혼합적층선재의 외부자장 변화에 따른 손실 특설)

  • Lim, Hyoung-Woo;Lee, Dong-Min;Yun, Ki-Hyun;Cha, Guee-Soo;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.71-73
    • /
    • 2006
  • AC loss on variation of external magnetic field is a very important factor in development of power applications. In this paper, we measured and compared AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires and uniform-multi-stacked wire made of one type of wires, 1G wires or 2G wires. Measurement was performed using by the linked-picked coil method. As results, as the number of wires increase, AC loss per unit volume of both stacked wires in low external magnetic field is reduced. Also AC loss of 2G slacked wire is higher than that of 1G wire. AC loss per unit length of 2G stacked wire is less than that of 1G stacked wire. And AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires was between uniform-multi-stacked wire made of 1G wires and 2G wires.

  • PDF

Regional load deflection rate of multiloop edgewise archwire (Multiloop edgewise arch wire의 부위별 하중변형률)

  • Kim, Byoung-Ho;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.29 no.6 s.77
    • /
    • pp.673-688
    • /
    • 1999
  • This study was conducted in order to analyze the mechanical characteristics of multiloop edgewise archwire (MEAW). The purposes were 1) to compare load deflection rate (LDR) of MEAW with that of various other arch wires in the individual interbracket span, 2) to compare the wire stiffness in the interbracket span with that in the multi-L-loop region (the span from distal border of the bracket of the lateral incisor to the mesial border of the buccal tube of the second molar), and 3) to verify the experimental results with theoretically derived formula. The single L-loops of five different horizontal lengths and multi-L-loops for the upper and lower arches were made out of .$016\times.022$ permachrome stainless steel wire. Straight segment of plain stainless steel, TMA and NiTi wire of the same dimension were prepared. The LDR was measured using Instron model 4466 with the load cell of 50N capacity at cross head speed of 1.0mm/min, and maximum deflection of 1.0mm. Five specimens were tested under each experimental condition. The wire stiffness number for each interbracket region and multi-L-loop region was calculated from the LDR and the interbracket spans. By dividing the theoretical model of multi-L-loop into 35 linear segments, the energy stored in each segment was obtained. Then the LDR and wire stiffness of single L-loop and multi-L-loop were calculated and compared. The findings were as follows : 1) The average LDR of MEAW in the individual interbracket region was 1/1.53 of that of the NiTi,1/2.47 of TMA and 1/5.16 of the plain stainless steel wire. 2) The wire stiffness of MEAW in the multi-L-loop region was 1.53 times larger than that in the interbracket region, and the LDR was almost twice as large as that of NiTi in that region. 3) According to the theoretically derived equation, the wire stiffness of the single L-loop was lower than that of multi-L-loop. The results of this study suggest that MEAW has the unique mechanical Property which could allow individual tooth movement and transmit elastic force effectively through the entire arch wire.

  • PDF

EFFECTS OF LOW-TEMPERATURE HEAT TREATMENT ON ELASTIC MEMORY PROCESS OF COLD WORKED STAINLESS STEEL WIRE (열처리가 냉간가공한 stainless steel wire의 복원양상에 미치는 영향)

  • Oh, Jeung-Sei;Park, Soo-Byung;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.22 no.3 s.38
    • /
    • pp.647-656
    • /
    • 1992
  • The purpose of this study was to evaluate the elastic memory process in cold worked stainless steel wire and the effect of heat treatment on it. 0.018 inch round and $0.019\times0.025$ inch rectangular wire (ORMCO stainless wire) were used in this study. Each wire type had 4 groups: non-heat treatment group, furnace heat treatment group, electric current heat treatment group, and bending after heat treatment group. Each group was consisted of 10 specimens. With the Jig, each wire was bent into v-shape uniformly, and width of two free ends of each v-shaped wire was measured by caliper (to the point of 0.1 mm correctly) at time interval of offjig, after heat treatment, 1, 2, 3, 4 hours, 1, 2, 3, 4, 5, 6 days, 1, 2, 3, 4 weeks after. The results were as follows: 1. In non-heat treatment group and bending after heat treatment group, elastic memory process was occured $60\%$ within 1 hour, and more than $90\%$ within 1 week. 2. In furnace and electric current heat treatment group, almost all elastic memory process was occured during teat treatment, and then specimen was stabilized dimensionally. 3. Magnitude of deformation by elastic memory was greater in heat treatment group than non heat treatment group and bending after heat treatment group. 4. There was no remarkable difference in deformation pattern between 0.018 inch round wire and $0.019\times0.025$ inch rectangular wire.

  • PDF

A COMPARATIVE STUDY OF FRICTIONAL RESISTANCES BETWEEN ORTHODONTIC BRACKETS AND ARCH WIRE DURING SLIDING MOVEMENT OF TEETH (치아의 활주 이동시 교정용 brackets와 arch wire사이에서 발생하는 마찰 저항력에 관한 비교 연구)

  • Min, Jung-Mi;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.18 no.1 s.25
    • /
    • pp.155-163
    • /
    • 1988
  • The purpose of this study was to evaluate and compare frictional forces generated between orthodontic brackets and arch wires. Independent variables were chosen for study: arch wire size and shape, arch wire material, bracket width, and second-order angulation between bracket and arch wire. Kinetic frictional forces of stainless steel (0.014', 0.016', 0.018', 0.016' ${\times}$ 0.022', 0.018' ${\times}$ 0.022'), $\beta-titanium$ (0.016' ${\times}}$ 0.022') arch wires were measured on wide and junior edgewise twin brackets (0.018' ${\times}$ 0.022' slot). Instron was used to pull arch wires while $0^{\circ},\;3^{\circ},\;6^{\circ},\;or\;9^{\circ}$ angulation between and wire and bracket was given. The results were as follows: 1. The frictional force of $\beta-titanium$ wire was larger than that of stainless steel wire. 2. The frictional force was generally increased as the size of wire is increased. 3. The frictional force of rectangular wire was larger than that of round wire. 4. As second order angulation was increased, the frictional force was also increased. 5. The frictional force was larger on a wide bracket than on a junior bracket.

  • PDF

An Experimental Study on the Fracture Characteristics of Wire Ropes (와이어 로프의 파단특성에 관한 실험적 연구)

  • 김종현;이근오;태순호
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.4
    • /
    • pp.3-10
    • /
    • 1994
  • This study examines fracture characteristics of wire rope of 6$\times$37+FC 14mm B degree, Which has been widely used for the strength support for machinery, cranes and shipping. The examination Is based on the fellowing experimental conditions. Firstly, this study analyzes the effect of the strength of wlre rope. When number of broken wires is occuring at the level of 5%, 10% and 15% degree respectively in the following two cases:1) Case of broken down to each strand equally. 2) Case of broken down to one strand only. Secondly, this study analyzes the effect of corrosion on the strength of wire rope. Corrosion times are 72hours, 144hours and 216hours corrosion respectively under following conditions. 1) Case of only a corrosion without wire breaking. 2) Case of corrosion after 5% degree wire breaking to each strand equally. Some outcomes of these experiment are as follows. 1) From the of tension test, We can find that the ratio of strength reduction case of wire broke down to one strand concentrically is greater than that ratio case of broke down to each strand equally. 2) From the corrosion test, We can also find that the ratio of strength reduction case of corroded after 5% degree wire breaking to each strand equally Is greater than that ratio case of corroded without wire breaking. 3) After comparing theoretical fracture load of wires with experimental fracture load of wires, we can find the fracture load of the case of broken down to each strand equally is most similar to theoretical fracture load. 4) It is proposed that safety rules on wire rope in the Industrial safety and healthy labor of law have to change “breaking over 10% of number of wires in one strand of wire rope(excluded filler wire )”has to be replaced by“breaking over 10% of number of all wires in all strand of wire rope(excluded filler wire)”

  • PDF

Al5052 Welding by $CO_2$ Laser using Filler Wire (용접 와이어를 사용한 Al5052 $CO_2$ 레이저 용접)

  • 박기영;이경돈;김주관
    • Laser Solutions
    • /
    • v.5 no.1
    • /
    • pp.13-21
    • /
    • 2002
  • Compared to conventional welding process, laser welding does not use additional filler wire generally. However, if laser welding uses the filler wire, the applicability of the method can be broaden. When laser welding uses the filler wire, it is possible to enhance gap bridging ability and to prevent cracking in weld pool by metallurgical control. In this study, we had optimal condition and experimented gap bridging capability for butt welding with 2㎜ Al5052 alloys using the filler wire feeder. As the experimental parameters, wire feed rate and wire diameter are considered and then the performance of wire feed is evaluated under various filler wire welding conditions.

  • PDF

Comparison of inclination and vertical changes between single-wire and double-wire retraction techniques in lingual orthodontics

  • Hung, Bui Quang;Hong, Mihee;Yu, Wonjae;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.50 no.1
    • /
    • pp.26-32
    • /
    • 2020
  • Objective: The Heat Induction Typodont System (HITS), used in some recent studies, has a distinct advantage over previous tooth movement simulation methods. This study aimed to compare inclination and vertical changes between the single-wire and double-wire techniques during en masse retraction with different lengths of lever arms in lingual orthodontics using an upgraded version of the HITS. Methods: Duet lingual brackets, which have two main slots, were used in this study. Forty samples were divided into four groups according to the length of the lever arm (3-mm or 6-mm hook) and the retraction wire (single-wire or double-wire). Four millimeters of en masse retraction was performed using lingual appliances. Thereafter, 3-dimensional-scanned images of the typodont were analyzed to measure inclination and vertical changes of the anterior teeth. Results: Incisor inclination presented more changes in the single-wire groups than in the double-wire groups. However, canine inclination did not differ between these groups. Regarding vertical changes, only the lateral incisors in the single-wire groups presented significantly larger values than did those in the double-wire groups. Combining the effect of hook lengths, among the four groups, the single-wire group with the 3-mm hook had the highest value, while the double-wire group with the 6-mm hook showed the least decrease in crown inclination and extrusion. Conclusions: The double-wire technique with an extended lever arm provided advantages over the single-wire technique with the same lever arm length in preventing torque loss and extrusion of the anterior teeth during en masse retraction in lingual orthodontics.

Improvement on resolution of mono-filament wire (초음파 팬텀 내 모노필라멘트의 해상력 개선에 대한 연구)

  • Ma, Sang-Chull;Kong, Young-Kun
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.49-56
    • /
    • 2003
  • The purposes of this study are to improve the ultrasound resolution of various nylon and metallic mono-filament wires, therefore, it was tested that it analyze on nylon mono-filament wire of 0.1 mm in A Co.'s ultrasonic phantom and synthesis of C15 g tissue mimicking materials(TMM), analyze resolution of nylon and metallic mono-filament wires in water and TMM. The results obtained were summarized as follows: 1. Metallic mono-filament wire of 0.1 mm and nylon mono-filament wire of 0.12 mm, 180 denier showed that it cleared dot echo pattern. 2. Metallic and nylon mono-filament wire of 0.2 mm showed that it cleared comet tail echo by reverberation artifact. 3. Nylon and metallic mono-filament wire of 0.1 mm showed that it can used for dead zone and axial resolution test. 4. Nylon mono-filament wire compared with metallic mono-filament wire showed that it satisfy elasticity and construction. 5. Degree of hardness of na not changed mono-filament's echo textures.

  • PDF

1,4-Dioxane Decomposition by Catalytic Wet Peroxide Oxidation using Cu Wire Catalysts (Cu wire 촉매를 이용한 촉매습식과산화공정에 의한 1,4-다이옥산의 분해)

  • Lee, Dong-Keun;Kim, Dul Sun
    • Clean Technology
    • /
    • v.22 no.4
    • /
    • pp.281-285
    • /
    • 2016
  • Cu wire catalyst was highly reactive toward catalytic wet peroxide oxidation of the highly refractory 1,4-dioxane. While complete removal of 1,4-dioxane could be achieved with the catalyst, the removed 1,4-dioxane could not totally mineralized into $CO_2$ and $H_2O$. In accordance with the disappearance of 1,4-dioxane, formaldehyde and oxalic acid were formed gradually with reaction time and they went through maxima. At around the time of maximum concentrations of these two intermediates acetaldehyde concentration was increased drastically and showed maximum value. With the disappearance of these three intermediates, formic acid together with ethylene glycol diformate began to increase gradually. The Cu wire catalyst was proved also to be highly stable against deactivation during the reaction.

Velocity and Flow Friction Characteristic of Working Fluid in Stirling Engine Regenerator (II) - Flow Friction Characteristic of Working Fluid in Stirling Engine Regenerator - (스털링기관 재생기내의 작동유체 유속 및 마찰저항 특성(II) - 작동유체 유동마찰저항 특성 -)

  • Kim, T.H.;Choi, C.R.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • The output of the Stirling engine is influenced by the regenerator effectiveness. The regenerator effectiveness is influenced by heat transfer and flow friction loss of the regenerator matrix. In this paper, in order to provide basic data for the design of regenerator matrix, characteristics of flow friction loss were investigated by a packed method of matrix in the oscillating flow as the same condition of operation in a Stirling engine. As matrices, two different wire screens were used. The results are summarized as follows; 1. With the wire screen of No. 50 as regenerator matrices, pressure drop of working fluid of the oscillating flow is shown as 3 times higher than that of one directional flow, not too much influenced by the number of packed meshes. 2. With the wire screen of No. 100 as regenerator matrices, pressure drop of working fluid of the oscillating flow is shown as 2.5 times on the average higher than that of one directional flow, not too much influenced by the number of packed meshes. 3. Under one directional flow which used regenerator matrices with both 200, 240, and 280 wire screens of No. 50 and 320, 370, and 420 wire screens of No. 100, the relationship between the friction factor and Reynold No. is shown as the following formula. $$f=\frac{0.00326639}{Re\iota}-1.29106{\times}10^{-4}$$ 4. Under oscillating flow which used regenerator matrices with both 200, 240, and 280 wire screens of No. 50 and 320, 370, and 420 wire screens of No. 100, the relationship between the friction factor and Reynold No. is shown as the following formula. $$f_r=\frac{0.000918567}{Re\iota}+1.86101{\times}10^{-5}$$ 5. The pressure drop is shown as high in proportion as the number of meshes has been higher, and the number of packed wire screens as matrices increases.