• 제목/요약/키워드: 1-Degree of Freedom Vibration Isolation

검색결과 9건 처리시간 0.022초

회전 변형항을 고려한 진동파워 전달 경로별 기여도 분석 : 압축기계에의 응용 (Vibrational Power Path Analysis with Rotational Terms Included and Its Application to Compressor System)

  • 이호정;김광준
    • 한국소음진동공학회논문집
    • /
    • 제15권3호
    • /
    • pp.280-289
    • /
    • 2005
  • A single degree of freedom system and transmissibility are key concepts in many problems of vibration isolation. In order to apply this approach, however, several assumptions must be satisfied, which are often not realistic. For examples, in practical systems, vibration transmissions at multi-point with multi-degree of freedom(translational and rotational DOF) take place and mobilities or impedances of receiver structures cannot be ignored any more especially over high frequency range. Therefore, a multi-dimensional treatment is required for accurate estimation of dynamic behavior of the system. In this paper, an approach using vibrational power flow is introduced to deal with analysis of multi-dimensional vibration isolation system in a more practical way and in aspects of vibration isolations and vibration path analysis. Procedures of this approach and some results of research for vibrational power path analysis with rotational terms included are presented. Difficulties in this method are also discussed.

파워흐름 개념을 이용한 진동 절연법 (Power Flow Approach in Vibration Isolations)

  • 이호정;김광준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.170-177
    • /
    • 2004
  • A single degree of freedom system and transmissibility are key concepts in many problems of vibration isolation. In order to apply this approach, however, several assumptions must be satisfied, which are often not realistic. In this paper, an approach using vibration power flow is introduced to deal with vibration isolations in a more practical way. Procedures of this approach and some results of research are presented. Difficulties in this method are also discussed.

  • PDF

Vibration isolation with smart fluid dampers: a benchmarking study

  • Batterbee, D.C.;Sims, N.D.
    • Smart Structures and Systems
    • /
    • 제1권3호
    • /
    • pp.235-256
    • /
    • 2005
  • The non-linear behaviour of electrorheological (ER) and magnetorheological (MR) dampers makes it difficult to design effective control strategies, and as a consequence a wide range of control systems have been proposed in the literature. These previous studies have not always compared the performance to equivalent passive systems, alternative control designs, or idealised active systems. As a result it is often impossible to compare the performance of different smart damper control strategies. This article provides some insight into the relative performance of two MR damper control strategies: on/off control and feedback linearisation. The performance of both strategies is benchmarked against ideal passive, semi-active and fully active damping. The study relies upon a previously developed model of an MR damper, which in this work is validated experimentally under closed-loop conditions with a broadband mechanical excitation. Two vibration isolation case studies are investigated: a single-degree-of-freedom mass-isolator, and a two-degree-of-freedom system that represents a vehicle suspension system. In both cases, a variety of broadband mechanical excitations are used and the results analysed in the frequency domain. It is shown that although on/off control is more straightforward to implement, its performance is worse than the feedback linearisation strategy, and can be extremely sensitive to the excitation conditions.

전달율 행렬의 특이치를 이용한 다입력/다출력 제진대계의 절연성능 평가법 (Evaluation method of isolation performance for MIMO isolation table using singular value of transmissibility matrix)

  • 선종오;김광준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.324-329
    • /
    • 2012
  • Isolation tables are widely used for precision equipments and their isolation performances have been usually expressed and evaluated by transsmissibility. However, transmissibility is a concept for 1-degree of freedom(DOF) system. In practice, isolation tables are supproted by more than 4 springs. Each spring is subjected to vertical and horizontal ground vibrations, and also the table has more than 1-DOF. Therefore, isolation tables should be treated as multi-input/multi-output(MIMO) system of which isolation performance is expressed by transmissibility matrix. However, the matrix is too complicated to be an index for a system. In this paper, maximum singular value of transmissibility matrx is suggested as a simple performance index of a MIMO isolation system. Physical meaning of singular value is explained using a simple a 2-DOF isolation table. Furthermore, maximum singular values of passive, 3-DOF active and 6-DOF active isolation tables are obtained through experiments, and their meaning are explained and compared with each other.

  • PDF

헤테로-시넵틱 신경회로망을 이용한 유압시스템의 진동제어 (Active vibration isolation of a hydraulic system using the hetero-synaptic neural network)

  • 정만실;조동우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 춘계학술대회 논문집
    • /
    • pp.273-277
    • /
    • 1995
  • Many hudraulic components have nonlinearities to some extent. These nonlinearities often cause the time delay, thus degrading the performance of the hydraulic control systems and making it difficult to modelthem. In this paper, a new vibration isolation control algorithm that eliminates the necessity of a sophiscated modeling of hydraulic system was proposed. The algotithm is a hybrid type control shecheme consisting of a linear controller and a hetero-synaptic neural network controller. Using this control scheme, simulations and experiments were performed for 1 DOF(Degree of freedom) and 2 DOF vibration isolation. The hybrid type control algorithm can isolate the base vibration signifcantly rather than linear control algorithm. And from the weights in hetero-synaptic neural network, we can get the 2nd equivalent differentialmodel of the hydraulic control system with on-line control operation. This equivalent model provides us with much information, such as stability and the characteristics of the control system.

  • PDF

수치적 시뮬레이션과 충격 시험을 통한 수직방향 진동절연 완충기 설계 및 성능 평가 (Design and Performance Evaluation of the Vibration Absorber of Vertical Direction Using Numerical Simulation and Shock Test)

  • 박상길;방승우;권오철;이정윤;오재응
    • 한국소음진동공학회논문집
    • /
    • 제18권5호
    • /
    • pp.558-563
    • /
    • 2008
  • Vibration/shock affects biggest taking a train subtraction of vehicle and durability decline. Therefore, absorber is used for vibration/shock isolation and various qualities of the material and design are applied to isolation. This paper proposes vibration/shock absorber that applies 'Disc' spring. Through comparison with 'Disc' spring that has nonlinearity and coil spring that is having linearity, see effect that nonlinearity of isolation gets in vibration/shock Isolation. Coil spring and 'Disc' spring are non-linear numerical analysis and simulation through theory for this, get and investigate comparison result through an experiment finally. Expressed and formulated shock through 'Runge-Kutta' method/impact response to nonlinear-vibration-equation of 1 degree of freedom for numerical analysis. Double half sine pulse of excitation used and analyzed result through spectrum response analysis here. Response of disc spring is compared to response of coil spring by changing $h_o/t$ ratio with computer simulation and the usage of disc spring is increased through analysis of effect of design factors. The purpose of this paper is that the shock response of disc spring is calculated through numerical simulation and to design the optimal absorber under the limited condition. And then, the isolation effect was analyzed through the shock test.

수치 모델링과 충격 시험을 통한 수직방향 진동절연 완충기의 성능 평가 (Performance Evaluation of the Vibration Absorber of Vertical Direction using Numerical Modeling and Shock Test)

  • 박상길;방승우;권오철;이정윤;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.990-993
    • /
    • 2008
  • Vibration/shock affects biggest taking a train subtraction of vehicle and durability decline. Therefore, absorber is used for vibration/shock isolation and various qualities of the material and design are applied to isolation. This paper proposes vibration/shock absorber that applies 'Disc'spring. Through comparison with 'Disc' spring that has nonlinearity and coil spring that is having linearity, see effect that nonlinearity of isolation gets in vibration/shock isolation. Coil spring and 'Disc' spring are non-linear numerical analysis and simulation through theory for this, get and investigate comparison result through an experiment finally. Expressed and formulated shock through 'Runge-Kutta' method/impact response to nonlinear-vibration-equation of 1 degree of freedom for numerical analysis. Double half sine pulse of excitation used and analyzed result through spectrum response analysis here. Response of disc spring is compared to response of coil spring by changing ho/t ratio with computer simulation and the usage of disc spring is increased through analysis of effect of design factors. The purpose of this paper is that the shock response of disc spring is calculated through numerical simulation and to design the optimal absorber under the limited condition. And then, the isolation effect was analyzed through the shock test.

  • PDF

Study on Satellite Vibration Control using Adaptive Control Scheme

  • Oh, Se-Boung;Oh, Choong-Seok;Bang, Hyo-Choong
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제6권2호
    • /
    • pp.1-16
    • /
    • 2005
  • Adaptive control methods are studied for the Satellite to isolate vibration in spite of the nonlinear system dynamics and parameter uncertainties of disturbance. First, a centralized control scheme is developed based on the particle swarm optimization(PSO) algorithm and feedback theory to automatically tune controller gains. A simulation study of a 3 degree-of-freedom device was conducted to evaluate the performance of the proposed control scheme. Next, since a centralized control scheme is hard to construct model dynamics and not goad at performance when controller and systems environment are easily changed, a decentralized control scheme is presented to avoid these defects of the centralized control scheme from the point of view of production and maintenance. It is based on the adaptive control methodologies to find PID controller parameters. Experiment studies were conducted to apply the adaptive control scheme and evaluate the performance of the proposed control scheme with those of the conventional control schemes.

MR 감쇠기와 FPS를 이용한 하이브리드 면진장치의 퍼지제어 (Fuzzy control of hybrid base-isolator with magnetorheological damper and friction pendulum system)

  • 김현수
    • 한국지진공학회논문집
    • /
    • 제9권1호통권41호
    • /
    • pp.61-70
    • /
    • 2005
  • 본 연구에서는 하이브리드 면진장치가 설치된 단자유도 구조물에 대하여 진동대 실험을 수행하였다. 본 연구에서 사용된 하이브리드 면진장치는 네 개의 FPS와 한 개의 MR 감쇠기로 구성하였다. 다양한 크기 및 특성을 가진 지진하중을 하이브리드 면진장치가 설치된 구조물에 가하여 진동제어 성능을 평가하였다. 본 연구에는 준능동 MR 감쇠기의 저항력을 효과적으로 조절하기 위하여 퍼지제어기를 사용하였고 구조물에 부착된 계측기를 통하여 변위 및 가속도를 피드백으로 이용한다. 수동 및 준능동 제어기법을 사용하여 얻은 구조물의 응답을 서로 비교하였고 그 결과 FPS와 MR 감쇠기의 조합으로 다양한 특성의 하중을 받는 구조물의 진동제어를 효과적으로 수행할 수 있음을 알 수 있다.