• Title/Summary/Keyword: 1차 에너지

Search Result 1,706, Processing Time 0.037 seconds

Development of energy saving rotary blade for tractor(V) - research on the actual condition of rotary tilling & rotary power requirement in the central area - (에너지 절감형 트랙터 로타리날 개발 (V) - 중부지방에서의 로타리 경운작업 실태조사 및 경운부하 측정실험 -)

  • 오종진;김기대;이현동;김찬수;김성환;나건영
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.07a
    • /
    • pp.15-20
    • /
    • 2002
  • 우리나라 농용트랙터 농가 보급률은 2000년 현재 13.9%로 약 19만대 정도이며 연간 약 2만대 정도의 농용트랙터가 보급되고 있다 농작업 중 동력이 가장 크게 소요되는 경운작업은 1차 경기작업과 2차 쇄토작업으로 크게 나눌 수 있는데, 근래에는 이것을 동시 작업 화하여 작업시간과 에너지 및 경비를 절감할 수 있는 로타리 경운 작업만 실시하는 경향으로 발전하고 있다. (중략)

  • PDF

Research on the Development of Thermoelectric Generation System for Industrial Waste Heat Recovery (산업 폐열회술를 위한 열전발전시스템 개발 연구)

  • ;;;;;D.M.Rowe
    • Journal of Energy Engineering
    • /
    • v.9 no.1
    • /
    • pp.19-27
    • /
    • 2000
  • 본 연구에서는 폐열회수를 위한 열전발전기술개발의 일환으로 자체 고안한 열전발전시스템을 구성하였고 상용화된 열전모듈을 적용하여 다양한 온도범위에서 열전모듈의 출력성능을 시험하였다. 시스템에 적용된 실험용 열전소자로는 49개의 열전쌍으로 구성된 미국 A 사의 모듈과 127개의 열전쌍으로 구성된 국내 B 사에서 제조한 모듈을 사용하였으며, 열전모듈 한 개에 대하여 , 그리고 5개의 모듈을 직렬로 연결하여 온도차 ($\Delta$T)를 변화시키면서 이때의 출력변화를 측정하였고, 또한15$0^{\circ}C$로 고정된 온도차에서 부하저항을 변화시키면서 출력성능을 실험하여 발전출력에 미치는 시스템인자들을 조사하고 이를 적용한 발전시스템의 최적조건을 도출하고자하였다.

  • PDF

Stress Behaviors of Superheater Tubes under Load Change Operation in HRSG (배열회수보일러의 부하변동 운전에 따른 과열기 튜브들의 응력거동)

  • Chong, Chae-Hon;Song, Jung-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.33-39
    • /
    • 2008
  • The purpose of this study is not only to evaluate the stress behavior of tubes in superheater in HRSG during the load change operation but also to find root causes of failure from stress behavior. Firstly, temperature during operation was collected to perform stress analysis from actual HRSG. Part load and full load stress analysis which can be represented as the whole load change operations were performed using commercial finite element software. The possibility that can lead to tubes failure is found by stress analysis and its results is compared with metallurgical mircrostructure of failed tube which was taken from actual HRSG.

Secondary Air Nozzle Design of Combustion Chamber of 50 ton/day Commercial Incinerator (50톤/일 상업용 소각로 연소실 2차 공기 노즐 설계)

  • 박병수;이진욱;서정대;허일상
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.05a
    • /
    • pp.127-132
    • /
    • 1999
  • 우리나라의 도시폐기물 소각로는 화격자 위에 폐기물을 공급하고 화격자 밑에서 공기를 공급하는 스토커식 소각로를 대부분 채택하고 있다. 이러한 스토커 소각로 연소실내에서는 매우 복잡한 연소현상이 발생하는데, 연소실로 투입된 쓰레기는 먼저 건조부에서 수분의 건조가 일어나고, 화격자의 구동에 의해 쓰레기가 혼합 및 이송되면서 열분해, 가스화, 가연성분의 탈휘발화 및 연소, 일부 고정탄소의 표면연소 등의 반응이 일어난다. 그리고 1,2차 연소실에서는 휘발분 및 비산된 고체의 연소가 일어나는데, 이때 대류 및 복사열전달 등의 복잡한 현상을 수반하는 유동장이 형성된다. 더욱이 불균질한 특성을 갖는 쓰레기층 내에서의 복잡한 현상으로 인하여 발생하는 경계조건 설정의 불확실성으로 연소실내의 연소 현상을 전산해석하는 데에는 상당한 어려움이 있다.(중략)

  • PDF

A Comparative Study on the Environmental Impacts Potential Estimations from Korean Nuclear Power Generation Using LCA (LCA를 통한 국내 원전의 환경영향 평가 수행사례 비교)

  • 정환삼;김성호;하재주;김태운
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2004.11a
    • /
    • pp.277-282
    • /
    • 2004
  • 본 연구에서는 환경경영의 중요한 수단으로 대두되고 있는 전과정분석(Life Cycle Analysis; LCA)을 통해 원자력 발전기술을 평가한 주요 사례의 분석과정과 결과들을 비교하였다. 이는 선진국들이나 글로벌 선진기업들에서 채택하기 시작한 글로벌 환경친화성의 입증 요구 추세 속에서, 모든 재화의 생산에 전력은 필수 투입물이라는 점에서 그 중요성을 감안하여 수행되었다. 본 연구에서는 국내 전력의 40% 이상 공급을 담당하고 있는 원자력발전 기술을 중심으로 비교하였다. 우리나라의 대표적인 연구를 간 비교 결과 그 값의 차이는 최대 10^5 정도에 이르러, 이는 외국의 경우 10^1 수준의 차이를 보이는 데 비해 다소 많은 것으로 조사되었다. 이러한 차이는 사례에 따라 모형의 단순화 정도에 기인한 것으로 판단되며, 이는 전력의 타산업 기반성이나 국내 전력LCA 분석능력의 함양이 중요하다는 점에 비추어 시급히 개선되어야 할 것이라 제안한다.

  • PDF

Numerical Analysis of Forced and Mixed Convection around the Circular Cylinder for Compressible Flow (압축성 유동장에서의 원형 실린더 주위의 강제 및 혼합대류에 대한 수치 해석)

  • 최윤호;이현찬;유재석;김기현
    • Journal of Energy Engineering
    • /
    • v.4 no.1
    • /
    • pp.126-139
    • /
    • 1995
  • 저속의 압축성 유동장에서의 원형 실린더 주위의 유동 및 열전달특성을 해석하였다. 비압축성 유동장에서의 실린더 주위의 유동 및 열전달현상에 대하여는 실험과 수치해석을 포함한 광범위한 연구가 진행되어 왔으며 매우 잘 알려져 있다. 실린더 벽면과 주위 유동장의 온도차가 큰 경우, 밀도의 변화가 커지므로 유동장은 압축성 유체가 되나 지배 방정식의 복잡함과 적절한 수치해석 방법의 부족으로 실린더 주위의 유동장을 압축성유체로 해석한 경우는 매우 드물다. 현재 압축성유동 해석에 널리 사용되는 time marching algorithm은 저속의 유동장 해석시 지배방정식에 나타나는 eigenvalue들의 괴리에 의하여 수렴속도가 현저히 떨어지게 된다. 본 연구에서는 이와 같은 난점을 극복할 수 있는 time-derivative preconditioning 방법을 사용하여 온도차가 큰 유동장에서의 강제 및 혼합대류에 대한 계산을 수행하였고 이들의 열전달특성을 비교하였다. 강제대류의 경우 실린더 벽면 온도의 증가에 따른 밀도 감소의 영향은 유동장의 Re수를 감소시켜 확산의 영향을 증가시키면서, 혼합대류의 경우 부력의 영향은 가열되는 유동장의 범위와 재순환 영역을 강제대류에 비해 현저히 감소시킨다.

  • PDF

Analysis of Air Temperature and Humidity Distributions and Energy Consumptions according to Use of Air Circulation Fans in a Single-span Greenhouse (단동온실 내 공기순환팬 사용에 따른 온습도 및 에너지소비량 비교 분석)

  • Lee, Tae Seok;Kang, Geum Choon;Kim, Hyung Kweon;Moon, Jong Pil;Oh, Sung Sik;Kwon, Jin Kyung
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.276-282
    • /
    • 2017
  • The aim of this study was to compare and analyze air temperature and humidity distribution and energy consumptions according to using air circulation fans in single-span greenhouses. The greenhouses located in Cheongnam-myeon, Cheongyang-gun, Chungcheongnam-do, Korea. There were cherry tomatoes in the greenhouses and the size of greenhouses was as follows;ridge height : 3.2 m, wide : 6 m, length : 95 m. The heating system was composed of a hot-water boiler and 6 FCUs(Fan Coil Unit)-4 FCUs were on bottom with duct and 2 FCUs were installed at 2.0 m. A total of 18 air circulation fans(impeller's diameter : 230 mm) were bilaterally arranged in 2 rows in the experimental greenhouse. The sensors for measuring air temperature and humidity were located at a quarter and three quarters of a length. The height of sensors were 0.8 m, 1.8 m. To calculate energy consumption in greenhouses, water temperature at inlet and outlet in a water pump, volume of water were measured. Form February 3rd to March 23th, temperature, humidity and energy consumptions were measured during heating time(6pm~7am). In a greenhouse without fans, the average differences of temperature and humidity were $0.75^{\circ}C$, 2.31%, respectively. The operation of fans showed their differences to $0.42^{\circ}C$, 1.8%. The standard deviation of temperature and humidity between measuring points in the greenhouse with fans was lower than the greenhouse without fans. Total energy consumptions in a greenhouse without fans were 4,673 kWh. In the greenhouse with fans, the total energy consumptions were 4,009 kWh. The energy consumptions in a greenhouse with fans 14.2% were less than the greenhouse without fans. Therefore, air circulation makes temperature and humidity uniform and saves energy consumptions for heating.

Analysis of Energy Preference in the 4th Industrial Revolution Based on Decision Making Methodology (의사결정 방법론 기반 4차 산업혁명 시대 에너지 선호도 분석)

  • Nam, Soo-Tai;Shin, Seong-Yoon;Jin, Chan-Yong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.328-329
    • /
    • 2021
  • Newly, the fourth industrial revolution is a way of describing the blurring of boundaries between the physical, digital, and biological worlds. It's a fusion of advances in AI (artificial intelligence), robotics, the IoT (Internet of Things), 3d printing, genetic engineering, quantum computing, and other technologies. At the world economic forum in Davos, switzerland, in january 2016, chairman professor klaus schwab proposed the fourth industrial revolution for the first time. In order to apply the AHP (analytic hierarchy process) analysis method, the first stage factors were designed as Natural, Water, Earth and Atom energy. In addition, the second stage factors were organized into 9 detailed energies presented in the conceptual model. Thus, we present the theoretical and practical implications of these results.

  • PDF

In/Si (111)-$4{\times}1$ 표면의 상전이에 대한 연구

  • Yeo, Jong-Hun;Jeon, Yu-Jin;Sim, Hyeong-Jun;Lee, Geun-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.143-143
    • /
    • 2012
  • In/Si (111)-$4{\times}1$ 표면은 저온에서의 $8{\times}2$ 주기의 상과 상온에서의 $4{\times}1$ 주기의 상 사이에 상전이가 나타나는 것으로 알려져 있다. 지금까지의 연구에 의하면 저온 $8{\times}2$ 주기의 상에서는 최근 제시된 hexagon 구조 모형이 가장 설득력 있게 받아들여지고 있으나, 상온 $4{\times}1$ 주기의 상에 대해서는 정적인(static) 구조 모형과 동적요동(dynamic fluctuation) 모형이 제안되었다. 이 두 가지 구조 모형은 모두 2차 상전이를 의미하지만, 최근 엔트로피를 고려한 이론계산 결과는 이 상전이가 1차 상전이를 가짐을 시사하였다. 그래서 우리는 이 표면의 상전이를 저에너지전자회절 실험을 통하여 연구하였고, 온도를 상온에서 저온으로 낮출 때와 저온에서 상온으로 높일 때의 회절세기 변화로부터 가열과 냉각의 두 과정에서 상전이 온도가 서로 다르게 나타나는 히스테리시스 곡선을 보임을 관찰하였다. 이는 주사터널링현미경 이미지에서 $4{\times}1$ 상온 구조와 $8{\times}2$ 저온 구조가 상전이 온도 근처에서 공존하는 것으로 관찰되는 것과 상통하는 결과로 1차 상전이임을 나타낸다. 이에 우리는 이 표면의 구조 상전이가 1차 상전이인 것으로 결론지으며, 이와 함께 표면의 결함이 상전이에 미치는 영향에 대해서도 논의할 것이다.

  • PDF

Analysis of Trophic Structures and Energy Flows in Aquatic Ecosystem of the Lower Reaches of the Nakdong River (낙동강 하류 수 생태계의 영양구조와 에너지 흐름)

  • Jang, Sung-Hyun;Zhang, Chang-Ik;Na, Jong-Hun;Lee, Jung-Ho
    • Korean Journal of Environmental Biology
    • /
    • v.26 no.4
    • /
    • pp.292-302
    • /
    • 2008
  • The purpose of this study was to analyze the trophic structures and the energy flows in the lower reaches of the Nakdong River using the Ecopath model (Walter et al., 1997). The sampling and analyses were carried out at 6 sampling sites of the lower reaches of the Nakdong River on May and November in 2007. Total of 9 groups detritus, macrophytes, phytoplankton, zooplankton, zoobenthos, Cyprinus carpio, Hemibarbus labeo, Micropterus salmoides and other fishes were considered to assess the trophic relationship, energy flows and interactions among them in the study. As a result, it was concluded that the lower reaches of the Nakdong River was consisted of producers (Detritus, Macrophytes, Phytoplankton), primary consumers (Zooplankton, Zoobenthos, Cyprinus carpio, Hemibarbus labeo, Other fishes) and secondary consumer (Micropterus salmoides). The total system throughput was estimated at 2.7 kg m$^{-2}$ year$^{-1}$ including a consumption of 52%, exports of 9.1%, respiratory flows of 18.0% and flows into detritus of 20.9%. MTI (mixed trophic impacts) analysis demonstrated that Pseudobagrus fulvidraco had positive impact on Cyprinus carpio, Carassius cuvieri and Carassius auratus. On the other hand, other fishes had negative impact on Cyprinus carpio, Carassius cuvieri and Carassius auratus. Also, all the functional groups except detritus had a negative impact on themselves.