• Title/Summary/Keyword: 1차원 열전달 분석

Search Result 19, Processing Time 0.046 seconds

A Study on Thermal Conduction in Oyster Shell Incorporating Gypsum Objects (굴패각 배합 석고재료의 열전도 특성 연구)

  • Kwon, Sung-Hyun;Cho, Daechul
    • Clean Technology
    • /
    • v.19 no.2
    • /
    • pp.90-94
    • /
    • 2013
  • We investigated one-dimensional thermal conduction for gypsum objects incorporating oyster shell powder. We presumed that according to the portion of oyster shell in the hybrid structure conductive characteristics of that would also change as some physicochemical properties such as volatile organic compound (VOC) adsorption were found to be changed considerably. Based on Fourier's 2nd law of heat conduction an analytical analysis in a flat slab (one axis perpendicular to an infinite plane) was performed. We found that composition of oyster shell and conduction-related coefficients and parameters could greatly influence on the thermal profile of that conduction, and some model experiments also served for it in the affirmative.

Characterization of vertical temperature distribution in Hyporheic zone (지하수-지표수 혼합구간의 수직 온도 분포 특성 분석)

  • Kim, Hee-Jung;Lee, Jin-Yong;Lee, Seong-Sun;Hyun, Yun-Jung;Lee, Kang-Kun
    • Journal of Wetlands Research
    • /
    • v.13 no.2
    • /
    • pp.265-273
    • /
    • 2011
  • Hyporheic zone, where groundwater-stream water mixing occurs, sensitively responds to heat of groundwater and stream water temperature. Variation of stream water temperature has short time period and time dependent, because stream water temperature is influenced by daily fluctuation and seasonal air temperature. On the other hand, groundwater temperature is insignificant. In this study, we conducted 1-dimensional heat transfer analysis. The results show that there are differences of temperature distribution between gaining stream and losing stream with flux in hyporheic zone. Especially, variations of hyporheic water temperature show a significant difference in adjacent streambed, Also, the results shows that distribution of temperature was more affected by groundwater direction than intensity of flux.

A Study on Heat Transfer Characteristics of Laser Cutting for the CSP 1N Sheet Using High-power CW Nd:YAG Laser (고출력 CW Nd:YAG 레이저를 이용한 CSP 1N 박판 절단공정의 열전달 특성 분석)

  • Ahn, Dong-Gyu;Kim, Min-Su
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.5 no.1
    • /
    • pp.51-58
    • /
    • 2006
  • The objective of this research work is to investigate into heat transfer characteristics of the laser cutting of CSP 1N sheet using high power CW Nd:YAG laser. In order to investigate the heat transfer characteristics, three dimensional quasi stationary and steady-state heat transfer analysis has been carried out. The laser heat source is assumed as a volumetric heat source with a gaussian heat distribution in a plane. Through the comparison of the results of analyses with those of experiments, the proper finite element model has been obtained. In addition, characteristics of the three-dimensional heat transfer and temperature distribution have been estimated by the finite element model. Finally, the minimum temperature at the center for cutting of the material has been estimated.

  • PDF

Application of One-Dimensional Heat Transfer Models for Performance Prediction of a Thermodiode (열다이오드의 열전달 성능 예측을 위한 일차원 모델적용 연구)

  • Chun, Won-Gee;Kang, Yong-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.77-87
    • /
    • 2002
  • 그 열흐름의 방향이 인위적으로 조절 가능한 열다이오드 시스템에 관하여 일차원적 열전달 모델을 통하여 시스템의 열성능을 분석하였다. 열다이오드 시스템은 다수의 폐회로 유체 순환 루프로 구성되었으며 루프의 양단은 각각 태양열 흡열판과 방열판에 부착되었다. 한편, 열흐름의 방향 조절을 위하여 루프를 구성하는 튜브재의 연결 부위는 회전 가능한 조인트로 연결하였으며 열매체포는 물을 사용하였다. 본 연구에서는 열다이오드 시스템에 대하여 간단한 1차원 모델을 이용하여 시스템의 열성능을 평가하였으며 아울러 실측 결과와의 비교를 통하여 본 모델의 적용을 통한 시스템의 장기 예측에 대한 가능성을 확인하였다.

Application of Discrete Element Method to Evaluate Thermal Conductivity of Backfill Materials for Horizontal Ground Heat Exchanger (수평형 지중열교환기용 되메움재의 열전도도 평가를 위한 개별요소법 적용 연구)

  • Han, Eunseon;Yi, Jihae;Shon, Byonghu;Choi, Hangseok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.123.1-123.1
    • /
    • 2010
  • 수평형 지중열교환기의 최적설계를 위해서는 되메움재의 광물특성 및 입자크기, 열전도도(thermal conductivity), 열용량(heat capacity)등과 같은 열적 특성을 파악 하는 것은 중요하다. 수평형 지중 열교환기용 되메움재의 열전도도를 파악하기 위해 비정상 열선법을 적용한 QTM-500을 사용하여 포화도에 따른 천연규사-물-공기 혼합물의 열전도도를 측정하였다. 측정된 열전도도를 개별요소법(Discrete Element Mothod)에 근거한 2차원 수치해석 프로그램인 PFC2D(Particle Flow Code in 2 Dimension)를 이용하여 비교 분석하였다. 수치해석에서는 혼합물의 건조밀도를 일정하게 유지한 상태에서 포화도에 따라 가상의 물 입자 개수를 변화시켰다. 개별요소법을 이용한 열전달 수치해석에서는 입자의 접촉을 통해 발생한 thermal pipe에 의해 열전달이 이루어진다. 이러한 thermal pipe의 열전도도는 접촉된 두 입자의 열전도도와 접촉면의 평균 열전도도를 고려하여 적용하였다.

  • PDF

Analysis of Temperature and Total Heat of Heated Glass through Experimental Measurement and Three-Dimensional Steady-State Heat Transfer Analysis (실측실험과 3차원 정상상태 열전달 해석을 통한 발열유리의 온도 및 전열량 분석)

  • Lee, Do-Hyung;Yoon, Jong-Ho;Oh, Myeong-Hwan
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.111-116
    • /
    • 2015
  • Heat loss from windows and condensation occuring on its surface due to its lower insulation value causes much discomfort to occupants. In this study, Heated glass was used to make a basic study on prevention of condensation on glass surface for its heating functionality through experimental measurement and simulation analysis of total heat flux on the interior and exterior surface of glass. Error between experimental results and three dimensional steady-state heat transfer analysis were caused firstly, beacuse in the experimental chambers, cold chamber and steady temperature and humidity chamber, air temperature setting was not constant but rather ON/OFF control, and secondly, due to error rate in heat flux meter due to heat flux direction even in stable conditions.

A Study on the Visualization of Ice-formation Phenomena of Bath Water to Decide Maintenance Period of Gas Heater (가스히터 보수주기 결정을 위한 히터내부 열전달 매체액 결빙현상 가시화에 관한 연구)

  • Lee J. H.;Ha J. M.;Sung W. M.
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.3 s.15
    • /
    • pp.1-8
    • /
    • 2001
  • This study was carried out for the purpose of determination of maintenance period and investigation of weak point due to freeze when the gas heater of KOGAS valve station Is not operated in winter season. 3-dimensional non-linear numerical simulation was conducted in order to predict the time and location which bath water in heater reaches to ice point. FLUENT V 5.0, commercial code, is used for thermal fluid flow analysis. We thought this was problem of heat conduction solving the energy equation and modeled gas heater by using the real geometry and scale for performing the 3-dimensional simulation. It was analyzed complex heat transfer phenomena considering convection due to air on surface, conduction in insulation material, natural convection of liquid in heater and heat loss through the pipe.

  • PDF

Numerical Analysis for Thermal Response of Silica Phenolic in Solid Rocket Motor (고체 로켓 추진기관에서 실리카/페놀릭 열반응 해석 연구)

  • Seo, Sangkyu;Hahm, Heecheol;Kang, Yoongoo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.521-528
    • /
    • 2017
  • In this paper, the numerical analysis for heat conduction of silica/phenolic composite material, which is used for solid rocket nozzle liner or insulator, was conducted. 1-D Finite Difference Method for the analysis of silica/phenolic during the firing of solid rocket motor was used to calculate the heat conduction considering the surface ablation and the thermal decomposition. The boundary condition at the nozzle wall took into account the convective heat transfer, which was obtained by integration equation. The numerical results of the surface ablation and char depth were compared with the results of test motor that is TPEM-10. It was found that the result of calculation is favorably agreed with the thermal response of test motor.

  • PDF

Numerical Analysis for Thermal Response of Silica Phenolic in Solid Rocket Motor (고체 로켓 추진기관에서 실리카/페놀릭 열반응 해석 연구)

  • Seo, Sangkyu;Hahm, Heecheol;Kang, Yoongoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.4
    • /
    • pp.76-84
    • /
    • 2018
  • In this paper, the numerical analysis for heat conduction of silica/phenolic composite material, used for solid rocket nozzle liners or insulators, is conducted. A 1-dimensional finite difference method for the analysis of silica/phenolic during the firing of a solid rocket motor is used to calculate heat conduction, considering surface ablation and thermal decomposition. The boundary condition at the nozzle wall, considering the convective heat transfer, is obtained via integration equations. The numerical results of the surface ablation and char depth are compared with the results of a TPEM-10 test motor, finding that the result of calculation agrees with the thermal response of the test motor.

Design and Optimization of Vibration-resistant and Heat-insulating Support Structure of Fuel Cylinder for LNG Vehicles (차량용 LNG 연료 용기의 내진동 단열지지구조 설계 및 최적화)

  • Kwon, Hyun-Wook;Hwang, In-Cheol
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.6-11
    • /
    • 2014
  • To optimize the design of fuel cylinder for LNG vehicles, we introduced the design parameters of the inner and the outer tank of the vessel support structure by analyzing the structural characteristics of conventional design. We selected the inner and outer diameter of the hollow support bars and a dimension of the inner structure of the vessel among the design parameters for design optimization. In this study the temperature distribution and thermal stress of the support structure were evaluated by using the utility program as MSC/MARC. The evaluation criteria are first mode natural frequency, total transferred energy through support structure and thermal stress. The developed design satisfied the design criteria and it was made of prototype. The prototype was verified through three-dimensional vibration testing and thermal performance test.