• Title/Summary/Keyword: 1선

Search Result 15,803, Processing Time 0.044 seconds

Fabrication of Backscatter Electron Cones for Radiation Therapy (산란전자선을 이용한 강내측방조사기구의 제작과 특성)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.74-80
    • /
    • 2001
  • Purpose : Irradiation cones by using backscatter electrons are made for the treatment of superficial small lesions of skin, oral cavity, and rectum where a significant dose gradient and maximum surface dose is desired. Methods and Materials : Backscatter electrons are produced from the primary electron beams from the linear accelerators. The design consists of a cylindrical cone that has a thick circular plate of high atomic number medium (Pb or Cu) attached to the distal end, and the plate can be adjusted the reflected angle. Primary electrons strike the metal plate perpendicularly and produce backscatter electrons that reflect through the lateral hole for treatment. Using film and a parallel plate ion chamber, backscatter electron dose characteristics are measured. Results : The depth dose characteristic of the backscatter electron is very similar to that of the hard x-ray beam that is commonly used for the intracavitary and superficial lesions. The basckscatter electron energy is nearly constant and effectively about 1.5 MeV from the clinical megavoltage beams. The backscatter electron dose rate of $35\~85\;cGy/min$ could be achieved from modern accelerators without any modification. and the depth in water of $50\%$ depth dose from backscatter electron located at 6mm for $45^{\circ}$ angled lead scatter. The beam flatness is dependent on the slit size and the depth of treatment, but is satisfactory to treat small lesions. Conclusions : The measured data for backscatter electron energy, depth dose flatness dose rate and absolute dose indicates that the backscatter electrons are suitable for clinical use.

  • PDF

여름철 양돈장의 소독방법

  • Kim, Yong-Pal
    • The Korea Swine Journal
    • /
    • v.10 no.6 s.106
    • /
    • pp.95-99
    • /
    • 1988
  • 소독은 오염된 균수를 줄이는 것으로 집단방역의 제1방역선은 소독이요, 제2방역선은 백신접종이고, 제3방역선은 치료인 것이다. 양돈장의 효과적인 소독은 화창한 날 실시, 발판소독조관리철저, 돈방 소독은 주기적으로 실시, 돈체분무 소독, 음수소독 등이 중요하다

  • PDF

배전계통의 자동화 기술

  • 정재길
    • 전기의세계
    • /
    • v.29 no.4
    • /
    • pp.234-238
    • /
    • 1980
  • 본고의 내용은 다음과 같다. 1. 배전선의 고장구간 자동검축방식 2. 배전선의 원방감시 및 원격제어 3. 개폐기원격제어와 조합한 자동배전시스템 4. 배전선자동화의 장래

  • PDF

PHASE-DEPENDENT LINE PROFILES OF VV CEP (VV Cep의 공전궤도 위상에 따른 선 윤곽)

  • 김경미;최규홍
    • Journal of Astronomy and Space Sciences
    • /
    • v.9 no.1
    • /
    • pp.120-125
    • /
    • 1992
  • The normalized line profiles of VV Cep have been calculated by integrating the equation of transfer. The Sobolev theory was adopted and the wind velocity distribution was assumed to be V(r) = V$\infty(1-R_c/r)^{1/2}$. The peaks of the line profiles for the phase 0.06 and 0.80 appear at near half maximum and zero velocity surface of the wind, respectively.

  • PDF

Application limit of Yield Line Analysis on Welded T-joints in Cold-Formed SHS Sections (냉간성형 각형강관 T형 접합부의 항복선해석 전용한계)

  • Kang, Chang Hoon;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.3 s.70
    • /
    • pp.315-324
    • /
    • 2004
  • This study performs a yield line analysis of welded T-joints in cold-formed Square Hollow Sections (SHS) with the branch in axial compression. The existing yield line models proposed by Koto, Packer, Zhao, and CIDECT and the proposed yield line model of the previous study are compared, using the existing test results of welded T-joints in cold-formed SHS. The yield line model suggested in the previous paper, which is based on the simplified yield line analysis, is reviewed to evaluate its application limit on cold-formed SHS T-joints. In the proposed model, the round corner of the cold-formed SHS section and weld size are taken into account. Finally, the validity range of yield line analysis is determined by observing the actual failure modes and comparing the test value with the analysis value, set as ${\beta}^{\prime}{\leq}0.8$ where ${\beta}^{\prime}=0.8$, ${\beta}^{\prime}=b_1^{\prime}/b_0^{\prime}$, $b_1{^{\prime}}=b_1+t_0$ and $b_0{^{\prime}}=b_0-t_0$.

Evaluation of Lead Oxide Dosimeter for Quality Assurance of Electron Beam in Radiotherapy (방사선치료 전자선의 정도관리를 위한 Lead Oxide 선량계 평가)

  • Yang, Seungwoo;Han, Moojae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.79-83
    • /
    • 2021
  • In radiation therapy, electron beam is often used in the treatment of superficial lesion. Accurate measurements are required because electron beam interacts with them in the beam path and affects dose measurements. However, no research has been conducted on electron beam quality assurance. in this study, PbO-based dosimeter was fabricated as a basic study for electron beam quality assurance. Thus, the reproducibility and linearity of the energy of 6, 9, and 12 MeV were analyzed to evaluate measurement accuracy and precision. Reproducibility measurements show RSD value of 1.024%, 1.019% and 0.890%, respectively, at 6, 9, and 12 MeV. linearity measurements show 0.9999 R2 at 6, 9, and 12 MeV altogether. Both evaluations show that the PbO dosimeter has very good measurement accuracy and precision with excellent results.

Usefulness of the Mammography and the Breast Ultrasound (유방의 X선 검사와 초음파 검사의 유용성 연구)

  • Lee, In-Ja;Park, Kye-Yeon
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.349-356
    • /
    • 2007
  • Conclusions below are drawn after survey date from 1,969 samplers of mammography and 1,531 breast ultrasound for 10 months, from 1 July 2006 to 30 April 2007. 1. Ages between 40 and 50 of samplers take the largest part of age distribution, and 68.57% of mammography and 71.32% of samplers are fallen under the category. 2. Samplers judged by diseased patients are 31.95% samplers of mammography and 45.79% samplers of breast ultrasound. 3. Age distributions of diseased patients were from 30 to 60 in mammography, 30 to 50 in breast ultrasound. 4. Breast ultrasound shows little difference between left side and right side of diseased part, but mammography shows significant diseased part in both sides. 5. As a result of reading examination, there is higher probability of detection in order of Calcification, Nodular, Mass in mammography. And Cyst, Nodular, Mass in breast ultrasound. 6. As a reading examinations, probability of judging a certain disease in high in mammography, but breast ultrasound shows 1 or 2 kinds of disease.

  • PDF

A Study on the Factors of Spatial Scattered Ray Occurrence in the X-ray Radiography Room (엑스선 촬영실의 공간산란선 발생 인자에 관한 연구)

  • Na, Soo-Kyung;Han, Sang-Hyo
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.393-399
    • /
    • 2009
  • In this study, we measured the dose distribution of scattered ray in X-ray radiography room using an ion chamber and examined the dependency of scattered ray content on the scattered ray source and exposure condition. To study the factors of scattered ray occurrence in the acryl phantom, we measured the change in the scatted ray content according to the X-ray tube voltage (40~140 kV) and the field size ($10{\times}10\;cm^2$, $20{\times}20\;cm^2$, $35{\times}35\;cm^2$). For the $35{\times}35\;cm^2$ field size, the side-scattering rate ranged from 3.1% to 14.5%. The scattered ray contributions of the phantom, collimator, X-ray tube and wall were also measured. The scattered ray contribution of the phantom was higher than 95.4% for the entire tube voltage, and those of the collimator, X-ray tube and wall were 2.6%, 1.3% and 0.7%, respectively.

  • PDF

A study on the highly sensitive metal nanowire sensor for detecting hydrogen (수소감지를 위한 고감도의 금속 나노선 센서에 관한 연구)

  • An, Ho-Myoung;Seo, Young-Ho;Yang, Won-Jae;Kim, Byungcheul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.9
    • /
    • pp.2197-2202
    • /
    • 2014
  • In this paper, we report on an investigation of highly sensitive sensing performance of a hydrogen sensor composed of palladium (Pd) nanowires. The Pd nanowires have been grown by electrodeposition into nanochannels and liberated from the anodic aluminum oxide (AAO) template by dissolving in an aqueous solution of NaOH. A combination of photo-lithography, electron beam lithography and a lift-off process has been utilized to fabricate the sensor using the Pd nanowire. The hydrogen concentrations for 2% and 0.1% were obtained from the sensitivities (${\Delta}R/R$) for 1.92% and 0.18%, respectively. The resistance of the Pd nanowires depends on absorption and desorption of hydrogen. Therefore, we expect that the Pd nanowires can be applicable for detecting highly sensitive hydrogen gas at room temperature.

금속선을 삽입한 고체 추진제의 연소 특성 연구

  • 유지창;박영규;김인철;황갑성;현형수
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.85-92
    • /
    • 1995
  • HTPB/AP/Al이 기본 조성인 ADP 302 혼합형 추진제를 대상으로 4종의 금속선(Ag, Cu, Al, Ni-Cr)을 삽입하여 금속선 직경(0.1mm~0.8mm)별로 압력에 따른 금속선과 인접한 추진제의 연소 속도($r_w)를 측정하여 금속선 삽입 추진제의 연소 속도 증가비($r_w$/$r_sb$)와 압력 지수( n )의 변화를 고찰한 결과 금속선 종류에 따른 연소 속도 증가비($r_w$/$r_sb$)는 Ag> Cu>Al>Ni-Cr선을 삽입한 추진제의 순으로 나타났고 금속선의 열확 산 계수의 크기순과 일치하였다. Buckingham $\pi$ 이론을 적용한 무차원 해석으로부터 실험식을 구하여, 이 실험식에 의해 계산된 ($r_w)와 실험으로부터 얻어진 ($r_w)를 서로 비교하여 본 결과 잘 부합됨을 알 수 있었다. 또한 금속선 수에 따른 추진제 그레인의 연소 면적을 해석적으로 계산하여,($r_w$/$r_sb$)가 2, 3, 4, 5 배로 증가함에 따른 시간에 따른 연소 면적 증가비의 변화를 금속선 수에 따라서 비교하여 본 결과 정상 상태에서의 그레인의 연소 면적의 증가비($A_b$/$A_0$)는 금속선에 인접한 추진제의 연소 속도 증가비($r_w$/$r_sb$)와 일치했으며, 정상 상태의 연소 면적 증가비는 삽입된 금속선의 수와는 무관하며 정상 상태에 도달하는 시간에만 영향을 주는 것으로 나타났다.

  • PDF