• Title/Summary/Keyword: 01-01

Search Result 25,973, Processing Time 0.055 seconds

Status of Water Quality in Nakdong River Districts (낙동강 수계의 수질 현황)

  • Lim, Young-Sung;Cho, Ju-Sik;Lee, Hong-Jae;Lee, Young-Han;Sohn, Bo-Kyoon;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.2
    • /
    • pp.126-134
    • /
    • 1999
  • To provide the basic information for the water improvement and control of water resource in Nakdong river districts, the physico-chemical characteristics of water in four main streams and three branch streams of the river were investigated through 36 times totally, one time per each month from January in 1995 to November in 1997. The pH values of each sites in main or branch stream of Nakdong river was pH $6.3{\sim}9.3$ range, pH range of Jukpo and Namji area at spring and fall was almost over pH 8.5, which was exceeded the water quality standard for agriculture. DO values of Nakdong river was almost $8.0{\sim}13mg/l$, except for Kangchang area in downstream of Kumho river. BOD values in Dasa area where was prior to mixing of Kumho river was $1.5{\sim}4.8mg/l$, which was under the water quality standard for agriculture(8mg/l), but BOD values followed mixing of Kumho river was over the permit standard of agricultural water as $3.8{\sim}8.9mg/l$ in Koryung, $3.4{\sim}8.4mg/l$ in Jukpo and $3.3{\sim}7.8mg/l$ in Namji according to time or season. Especially, BOD values at Gangchang area in Kumho river were $7.6{\sim}18.5mg/l$, which was over the water quality standard for agriculture and so Kumho river was a main pollutant: source of Nakdong river. COD values of main stream of Nakdong river was over the permit standard of agriculture(8mg/l) as $5.2{\sim}13.5mg/l$ in Koryvng, $5.0{\sim}12.7mg/l$ in Jukpo and $5.0{\sim}12.2mg/l$ in Namji according to time or season. And COD values was much high rather than BOD values and its gap of concentration was increased along with downstream. $NH_4-N$ of main stream of Nakdong river followed mixing of Kumho river($0.5{\sim}13.1mg/l$) was the highest affected in Koryung($0.18{\sim}5.0mg/l$) and detected much more in winter than in summer. T-N in Koryung($4.96{\sim}12.06mg/l$) followed mixing of Kumho river was significantly high rather than $2.86{\sim}4.86mg/l$ in Dasa, $4.20{\sim}8.20mg/l$ in Jukpo and $3.18{\sim}8.64mg/l$ in Namji, which was almost over the permit standard of agricultural water(1.0mg/l). T-P in Koryung($0.10{\sim}0.58mg/l$) also was significantly high rather than those $0.07{\sim}0.36mg/l$ in Jukpo and $0.08{\sim}0.4mg/l$ in Namji as over the standard of agricultural water(0.1mg/l). The concentration of T-N or T-P in Nakdong districts was trended of increasing in every year.

  • PDF

Protective Effect of Plantago asiatica L. Leaf Ethanolic Extract Against Ferric Nitrilotriacetate-Induced Prostate Oxidative Damage in Rats (랫드에서의 Fe-NTA 유발 산화스트레스에 대한 차전초 에탄올 추출물의 전립선보호 효과)

  • Hong, Seung-Taek;Hong, Chung-Oui;Nam, Mi-Hyun;Ma, Yuan-Yuan;Hong, Yun-Jin;Son, Da-Hee;Chun, Su-Hyun;Lee, Kwang-Won
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.3
    • /
    • pp.260-265
    • /
    • 2011
  • Plantago asiatica L. (P. asiatica) has been used as one of the popular folk medicines in Asia for human health care practices. Various activities of P. asiatica have been reported, such as anti-oxidant, anti-glycation, anti-inflammatory and hepatoprotective activity. Therefore, the potential of P. asiatica to reduce oxidative stress has been studied in several ways for over 20 years, especially at liver and kidney. However no investigation has been reported revealing its protective effect on prostate. Method: Treatment of P. asiatica leaf ethanolic extract (PLE) (1 g/kg body weight (b.w.), 2 g/kg b.w., or 4 g/kg b.w.) were given separately to animals for pretreatment once per day for 7 days, and on the seventh day ferric nitrilotriacetate (Fe-NTA; 0.24 mmol Fe/kg b.w.), which is known as an oxidative stress-inducer at prostate, was administrated by i.p to negative control group. At the end of the study period, dissection was carried out for detecting the prostate protective effect of PLE. Result: Fe-NTA-treated animals produced reactive oxygen species (ROS) resulting in depletion of antioxidant biomaker, such as glutathione (GSH), glutathione reductase (GR), and glutathione s-transferase (GST) and increase of lipid peroxidation in prostate. However, PLE pretreatment resulted in an increase in the GSH, GST and GR levels concentration dependent manner and in an significant decrease in the levels of lipid peroxidation. Conclusion: Our data suggest that PLE may be effective in protecting oxidative stress-induced damage of prostate, and PLE may be an chemopreventive agent against Fe-NTA-mediated prostate oxidative damage.

A Study on the Characteristics of Dietary Behaviors and Food Intake Patterns of University Student according to the Obesity Index (대학생의 비만도에 따른 식생활 특성 및 식이섭취 양상에 관한 연구)

  • Oh Se-In;Lee Mee-Sook
    • The Korean Journal of Food And Nutrition
    • /
    • v.19 no.1
    • /
    • pp.79-90
    • /
    • 2006
  • This study was performed to investigate the dietary behaviors and food intake patterns of university students according to the obesity index(OI). The subjects were 349 students(107 males and 242 females) who were assigned to one of the following groups based on the percentage of ideal body weight: underweight(OI< 90%), normal ($90%{\leq}Ol<10%$) and overweight($OI{\geq}110%$). The dietary behaviors and food intake patterns were evaluated by questionnaires and 24 hour recall method. The results were summarized as follows. The rates of underweight, normal, and overweight students were 33.8%, 61.0%, and 5.2% respectively. The ratios of underweight was higher than overweight, especially in case of female. The 60.46% of subjects responded that they had an irregular eating habits, especially in overweight group(72.22%). The 52.44% of subjects showed skipping mealtime more than one time per day. The overweight group had a tendency to overeat themselves than other groups. The normal group had less unbalanced dietary pattern than the other groups(p<0.0019). Most subjects had a snack(96.27%). The percentage of those who drank and smoked were 86.74% and 19.54%, respectively. The smoking value was significantly higher in the overweight group(p<0.0009). The food consumption frequency by food groups was not different among the groups except instant and fast food. More than 50% subjects consumed fish, legumes & its products, and vegetables everyday. There was significantly less rate of the instant and fast food consumption frequency in the normal group(p<0.0177). The 3/4 subjects that showed the lower consumed level in RDA(< 75%) were under-nutritional state in the Fe and Ca. In case of Ca, there was a higher NAR value in the overweight group(p<0.0257) significantly, and Fe, protein, vitamin $B_1$, vitamin $B_2$, and niacin showed similar tendencies. The INQ of Fe was significantly higher in the overweight group than other groups(p<0.0335).

The Study of Radiation Reducing Method during Injection Radiopharmaceuticals (방사성의약품 투여 시 피폭선량 저감에 대한 연구)

  • Cho, Seok-Won;Jung, Seok;Park, June-Young;Oh, Shin-Hyun;NamKoong, Hyuk;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.80-85
    • /
    • 2012
  • Purpose: The whole body bone scan is an examination that visualizing physiological change of bones and using bone-congenial radiopharmaceutical. The patients are intravenous injected radiopharmaceutical which labeled with radioactive isotope ($^{99m}Tc$) emitting 140 keV gammarays and scanned after injection. The 3 principles of radiation protection from external exposureare time, distance and shielding. On the 3 principles of radiation protection basis, radiopharmaceutical might just as well be injected rapidly for reducing radiation because it might be the unopened radiation source. However the radiopharmaceuticals are injected into patient directly and there is a limitation of distance control. This study confirmed the change of radiation exposure as change of distance from radiopharmaceutical and observed the change of radiation exposure afte rsetting a shelter for help to control radio-technician's exposure. Materials & methods: For calculate the average of injection time, the trained injector measured the injection time for 50 times and calculated the average (2 minutes). We made a source as filled the 99mTc-HDP 925 MBq 0.2 mL in a 1 mL syringe and measured the radiation exposure from 50 cm,100 cm,150 cm and 200 cm by using Geiger-Mueller counter (FH-40, Thermo Scientific, USA). Then we settled a lead shielding (lead equivalent 6 mm) from the source 25 cm distance and measured the radiation exposure from 50 cm distance. For verify the reproducibility, the measurement was done among 20 times. The correlation between before and after shielding was verified by using SPSS (ver. 18) as paired t-test. Results: The radiation doses according to distance during 2 minutes from the source without shielding were $1.986{\pm}0.052{\mu}$ Sv in 50 cm, $0.515{\pm}0.022{\mu}$ Sv in 100 cm, $0.251{\pm}0.012{\mu}$ Sv in 150 cm, $0.148{\pm}0.006{\mu}$ Sv in 200 cm. After setting the shielding, the radiation dose was $0.035{\pm}0.003{\mu}$ Sv. Therefore, there was a statistical significant difference between the radiation doses with shielding and without shielding ($p$<0.001). Conclusion: Because the great importance of whole body bone scan in the nuclear medicine, we should make an effort to reduce radiation exposure during radiopharmaceutical injections by referring the principles of radiation protection from external exposure. However there is a limitation of distance for direct injection and time for patients having attenuated tubules. We confirmed the reduction of radiation exposure by increasing distance. In case of setting shield from source 25 cm away, we confirmed reducing of radiation exposure. Therefore it would be better for reducing of radiation exposure to using shield during radiopharmaceutical injection.

  • PDF

Analysis of Patient Effective Dose in PET/CT; Using CT Dosimetry Programs (CT 선량 측정 프로그램을 이용한 PET/CT 검사 환자의 예측 유효 선량의 분석)

  • Kim, Jung-Sun;Jung, Woo-Young;Park, Seung-Yong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.77-82
    • /
    • 2010
  • Purpose: As PET/CT come into wide use, it caused increasing of expose in clinical use. Therefore, Korea Food and Drug Administration issued Patient DRL (Diagnostic Reference Level) in CT scan. In this study, to build the basis of patient dose reduction, we analyzed effective dose in transmission scan with CT scan. Materials and Methods: From February, 2010 to March 180 patients (age: $55{\pm}16$, weight: $61.0{\pm}10.4$ kg) who examined $^{18}F$-FDG PET/CT in Asan Medical Center. Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY) and Discovery STe8 (GE healthcare, USA) were used in this study. Per each male and female average of 30 patients doses were analyzed by one. Automatic exposure control system for controlling the dose can affect the largest by a patient's body weight less than 50 kg, 50-60 kg less, 60 kg more than the average of the three groups were divided doses. We compared that measured value of CT-expo v1.7 and ImPACT v1.0. The relationship between body weight and the effective dose were analyzed. Results: When using CT-Expo V1.7, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.46{\pm}1.18$ mSv, $9.36{\pm}1.96 $mSv and $9.36{\pm}1.96$ mSv for 30 male patients respectably $6.29{\pm}0.97$ mSv, $10.02{\pm}2.42$ mSv and $9.05{\pm}2.27$ mSv for 30 female patients respectably. When using ImPACT v1.0, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.54{\pm}1.21$ mSv, $8.36{\pm}1.69$ mSv and $9.74{\pm}2.55$Sv for 30 male patients respectably $5.87{\pm}1.09$ mSv, $8.43{\pm}1.89$ mSv and $9.19{\pm}2.29$ mSv for female patients respectably. When divided three groups which were under 50 kg, 50~60 kg and over 60 kg respectably were 6.27 mSv, 7.67 mSv and 9.33 mSv respectably using CT-Expo V1.7, 5.62 mSv, 7.22 mSv and 8.91 mSv respectably using ImPACT v1.0. Weight and the effective dose coefficient analysis showed a very strong positive correlation(r=743, r=0.693). Conclusion: Using such a dose evaluation programs, easier to predict and evaluate the effective dose possible without performing phantom study and such dose evaluation programs could be used to collect basic data for CT dose management.

  • PDF

The Quantitative Assessment of Renal Function and Size by Differences of Acquisition Counts in $^{99m}Tc$-DMSA Renal Scan ($^{99m}Tc$-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가)

  • Shim, Dong-Oh;Kim, Ho-Sung;Chung, Eun-Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.117-121
    • /
    • 2010
  • Purpose: In nuclear medicine study, there are two methods, preset count method and preset time method, to acquire static images. We usually use preset count method for static image in $^{99m}Tc$-DMSA renal scan, but occasionally use preset time method. In case of using preset count method, we always acquire same counts but it causes a difference of scan time. In case of using preset time method, it takes same scan time to acquire images but it causes different counts. Therefore, the purpose of this study is to investigate any differences of function and formal information in both kidney by acquisition counts Materials and Methods: From January 11, 2010 to March 31, 2010, we analyzed the 30 patients (M: 11, W: 19). who were examined by $^{99m}Tc$-DMSA scan and have one side of functioning kidney relatively between 40~60%. And the patients who have cold and hot region in image were analyzed but we did not accept images of patients when it was hard to divide kidney into cortex. There was no division between subjects and age of subjects is $14.83{\pm}22.07$ old. We used the BrightView gamma camera from PHILIPS. To analyze function and formal of kidney, we used JET stream release 3.0 version from PHILIPS. Using SPSS 12.0 program, we compared descriptive statistics and paired T-test. Images were acquired sequentially in the same parameters, but there are three methods which different from acquisition time and scan time, 100 kcounts, 300 kcounts and 7 minutes method (exceed 300 kcounts). To assess function and formal information of kidney, we measured renal relative function, geometric mean and size of kidney and analyzed each difference. Results: In case of renal relative function in both kidney, 100 kcounts method was $50.52{\pm}3.64%$. 300 kcounts method was $50.38{\pm}3.66%$ and 7 minutes method was $49.91{\pm}3.40%$ and there were no statistical significant differences between each method. In case of geometric mean, 100 kcounts method was $50.08{\pm}3.25%$. 300 kcounts method was $49.89{\pm}3.40%$ and 7 minutes method was $49.91{\pm}3.24%$. And also, there were no statistical significant differences. When comparing size of kidney, 100 kcounts method was $8.23{\pm}1.96$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.35{\pm}1.97$ cm. In case of right kidney, 100 kcounts method was $7.91{\pm}1.88$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.25{\pm}1.96$ cm. From those values, we recognized that there were significant differences each method (p<0.05). Conclusion: From results of this study, there were no statistical differences in renal relative function and geometric mean by acquisition counts. However, in shape of kidney, the more acquisition counts are increasing, the more size of kidney is getting big. And there were statistical significant differences. Therefore, to perform reliable quantitative result, preset count method is more desirable than preset time method. Especially, in case of a follow-up test, if we use preset time method, it will cause differences of formal results in kidney due to acquisition counts each time we examine patients.

  • PDF

Usefulness Evaluation of Open Mouth View when PET/CT scan In Tongue Cancer Patients (Tongue Cancer 환자에서 PET/CT 검사 시 Open Mouth 촬영법의 유용성 평가)

  • Kim, Jae Hwan;Yun, Jong Jun;Jung, Ji Wook;Kim, Jung Wook;Hwang, Ju Won;Ji, Hye In
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.14-20
    • /
    • 2016
  • Purpose Tongue cancer is 1.8% of all cancer tumors occur in the tongue, it is known that the high incidence enough to account for 75% of oral cancer conducted a PET / CT examination for early diagnosis, metastasis, staging, etc. and. Tongue when PET / CT scan of a cancer patient and a Torso taken to close mouth lesions if the condition was caused due to the overlapping or corresponding artifacts are not clearly observed. The purpose of this study is to evaluate the changes that occur during PET / CT scan with open mouth and its usefulness under. Materials and Methods From June 2015 to March 2016 complained of herein by May 21 had received a diagnosis of tongue cancer underwent PET / CT scan patients were treated with a target (16 males, 5 female). The first was taken to close mouth Torso state, it was taken to add 1 bed open mouth condition. Tumor (T), measuring the Normal Tongue (NT), Lymph Node (LN) standard intake coefficient by setting a region of interest in the (standardized uptake value, SUV) SUVmean, the average value was measured SUVmax, drawn to each region of interest 3 times and Background (Carotid artery) was out of the SUV. In Chapter 3 of the slice to the tumor clearly visible by setting the region of interest to measure the change Tumor size was calculated average value. Gross Image resolution assessment were analyzed statistically through were divided into 1-5 points by the Radiation 7 people in 2, more than five years worked in specialized nuclear medicine compare to proceed with the blind test nonparametric test (wilcoxon signed rank test). (SPSS ver.18) Results $SUV_{mean}$ T's were in close mouth $5.01{\pm}2.70$ with open mouth $5.48{\pm}2.88$ (P<0.05), $SUV_{max}$ were respectively $8.78{\pm}5.55$ and $9.70{\pm}5.99$ (P<0.05). $SUV_{mean}$ in the NT were respectively $0.43{\pm}0.30$ and $0.34{\pm}0.24$ (P=0.20), $SUV_{max}$ was $0.56{\pm}0.34$ and $0.45{\pm}0.25$ (P=0.204). LN $SUV_{mean}$ were respectively $1.62{\pm}1.43$ and $1.69{\pm}1.49$ (P=0.161), $SUV_{mean}$ was $2.09{\pm}1.88$ and $1.99{\pm}1.74$ (P=0.131). Tumor size change is close mouth $4.96{\pm}4.66cm^2$ $5.33{\pm}4.64cm^2$ with 7.45% increase was (P<0.05), gross image resolution evaluation is $2.87{\pm}0.73$, $3.77{\pm}0.68$ with open mouth examinations 30.5% increase was (P<0.05). Conclusion Tumor SUV on the changes that had an increase in open mouth during inspection, the normal tongue and lymph node, but there was no significant difference in the change slightly. It is also one open mouth PET / CT scan will provide improved image to all patients with tongue cancer, but it could be confirmed that similar overall through the blind test, or tumor size changes and showing a high resolution image. It can be the perfect alternative method for problems that occur when the close mouth Open mouth PET / CT scan, but is believed to be through the open mouth to observe the boundary of overlapping or tumor of the oral cavity other structures a little more clearly. Tongue cancer patients how to recommend that the shooting further open mouth PET / CT.

  • PDF

On the Wood Properties of Genus Pinus Grown in Korea (소나무속(屬)의 재질(材質)에 관(關)한 시험(試驗))

  • Jo, Jae-Myeong;Kang, Sun-Goo;Ahn, Jung-Mo;Lee, Chan-Ho;Jo, Nam-Suk;Shim, Chong-Supp;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.96-108
    • /
    • 1982
  • Pinus is one of the most important species supplying domestic industrial timbers such as constitutional lumber, pulpwood, and mine props. It occupies nearly 50 percent of the total forest resources in Korea. With above conception, to develop this forest resources and to obtain the basic data on the reasonable and effective utilization of Pinus, this study was carried out. Five species (P. koraiensis S. et Z., P. densiflora S. et Z., P. thunbergii Parlat, P. densiflara far erecta, P. rigida Miller) grown in Kwangnoong experimental forest stand, Chungcheongnam-Do, and Gangwon-Do regions were selected as sample trees. Anatomical, physical, mechanical and chemical properties of them were investigated.

  • PDF

The Study about Application of LEAP Collimator at Brain Diamox Perfusion Tomography Applied Flash 3D Reconstruction: One Day Subtraction Method (Flash 3D 재구성을 적용한 뇌 혈류 부하 단층 촬영 시 LEAP 검출기의 적용에 관한 연구: One Day Subtraction Method)

  • Choi, Jong-Sook;Jung, Woo-Young;Ryu, Jae-Kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.102-109
    • /
    • 2009
  • Purpose: Flash 3D (pixon(R) method; 3D OSEM) was developed as a software program to shorten exam time and improve image quality through reconstruction, it is an image processing method that usefully be applied to nuclear medicine tomography. If perfoming brain diamox perfusion scan by reconstructing subtracted images by Flash 3D with shortened image acquisition time, there was a problem that SNR of subtracted image is lower than basal image. To increase SNR of subtracted image, we use LEAP collimators, and we emphasized on sensitivity of vessel dilatation than resolution of brain vessel. In this study, our purpose is to confirm possibility of application of LEAP collimators at brain diamox perfusion tomography, identify proper reconstruction factors by using Flash 3D. Materials and methods: (1) The evaluation of phantom: We used Hoffman 3D Brain Phantom with $^{99m}Tc$. We obtained images by LEAP and LEHR collimators (diamox image) and after 6 hours (the half life of $^{99m}Tc$: 6 hours), we use obtained second image (basal image) by same method. Also, we acquired SNR and ratio of white matters/gray matters of each basal image and subtracted image. (2) The evaluation of patient's image: We quantitatively analyzed patients who were examined by LEAP collimators then was classified as a normal group and who were examined by LEHR collimators then was classified as a normal group from 2008. 05 to 2009. 01. We evaluate the results from phantom by substituting factors. We used one-day protocol and injected $^{99m}Tc$-ECD 925 MBq at both basal image acquisition and diamox image acquisition. Results: (1) The evaluation of phantom: After measuring counts from each detector, at basal image 41~46 kcount, stress image 79~90 kcount, subtraction image 40~47 kcount were detected. LEAP was about 102~113 kcount at basal image, 188~210 kcount at stress image and 94~103 at subtraction image kcount were detected. The SNR of LEHR subtraction image was decreased than LEHR basal image about 37%, the SNR of LEAP subtraction image was decreased than LEAP basal image about 17%. The ratio of gray matter versus white matter is 2.2:1 at LEHR basal image and 1.9:1 at subtraction, and at LEAP basal image was 2.4:1 and subtraction image was 2:1. (2) The evaluation of patient's image: the counts acquired by LEHR collimators are about 40~60 kcounts at basal image, and 80~100 kcount at stress image. It was proper to set FWHM as 7 mm at basal and stress image and 11mm at subtraction image. LEAP was about 80~100 kcount at basal image and 180~200 kcount at stress image. LEAP images could reduce blurring by setting FWHM as 5 mm at basal and stress images and 7 mm at subtraction image. At basal and stress image, LEHR image was superior than LEAP image. But in case of subtraction image like a phantom experiment, it showed rough image because SNR of LEHR image was decreased. On the other hand, in case of subtraction LEAP image was better than LEHR image in SNR and sensitivity. In all LEHR and LEAP collimator images, proper subset and iteration frequency was 8 times. Conclusions: We could archive more clear and high SNR subtraction image by using proper filter with LEAP collimator. In case of applying one day protocol and reconstructing by Flash 3D, we could consider application of LEAP collimator to acquire better subtraction image.

  • PDF

A Survey on Consumption Behaviors of the Fast-Foods in University Students (대학생의 패스트푸드 소비행태에 관한 연구)

  • Cho, Kyu-Seok;Im, Byoung-Soon;Kim, Seok-Eun;Kim, Gye-Woong
    • Korean Journal of Human Ecology
    • /
    • v.14 no.2
    • /
    • pp.313-319
    • /
    • 2005
  • This survey was conducted in order to obtain the basic data for desirable consumption habits through investigation and analysis of university students' fast food consumption behaviors. Questionnaires were collected from a total of 374 male and female students living in big or small and medium-sized cities in August, 2004. The contents surveyed were utilization and expenses of fast foods, choice of fast foods, relationship between fast foods and a diet, and characteristics of fast food restaurants. The results obtained are summarized as follows: 1. The ratio of the surveyees varied according to gender, residence, and the size of a city they're living in. For example, males took up 48.66% of the surveyees, while females did 51.34%. The ratio of residents in apartments and stand-alone houses was 54.81% and 45.19% each. 47.33% of the respondents were living in big cities, while 52.67% of them in small and medium-sized cities. 2. 70.1% of the surveyees responded that they are with friends when having fast foods. There was a highly significant difference between male and female in the type of eating companions (p<0.001). The average number of days that they eat fast foods was 1 to 2 times a week, which accounted for 63.7% of the respondents. However, in the case of eating foods, there was no significant differences between two sexes. 3. 64.2% of the surveyees paid more than 20,000 won to buy fast foods for a week, which showed no significant differences between genders. They tend to split a bill, rather than one person pays all. There was a highly significant difference between genders in paying method (p<0.001). 4. 52.1 % of the respondents chose a menu themselves. Their most favored food was chickens (26.5%), which showed a statistically significant difference between genders (p<0.001). 46.8% of them preferred coke as a drink, which had no significant difference between genders. 42.2% of the surveyees had fast foods between lunch and dinner, which also had no significant difference between genders. The most important factor in choosing a menu was its taste (62.8%), which indicated a significant difference between males and females (p<0.05). 5. The preference to fast foods was due to the influence of western culture (36.4%) and eating-out habits (29.1%), which was significantly different between genders (p<0.05). Those who eat fast foods answered they have normal weight and normal body type (49.5%). 24.3% of them were relatively fat with significant difference between genders (p<0.05). 63.4% of the surveyees thought themselves not picky with foods, and there was a significant difference between genders (p<0.05). 78.3% of them mostly preferred franchise restaurants because they are convenient and cheap.

  • PDF