• Title/Summary/Keyword: 0-mode

Search Result 4,601, Processing Time 0.035 seconds

Fast Intra Prediction Mode Decision for HEVC (HEVC의 고속 화면내 예측 모드 결정 기법)

  • Kim, Dong-Hyun;Kim, Jae-Gon
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.9
    • /
    • pp.102-109
    • /
    • 2014
  • Intra prediction in HEVC is also significantly improved from H.264/AVC with the increased prediction modes up to 35 that results in increase of the complexity cost. Hence, a fast intra mode decision algorithm is required for real-time applications. A fast intra mode decision is proposed in this paper for further complexity reduction in addition to the RMD (Rough Mode Decision) that has been adopted into the HEVC reference software, referred to as HM, for fast intra prediction. The proposed method reduces the complexity of intra mode decision by limiting the number of search modes in both steps of RMD and the final mode decision. Experimental results show that the proposed method provide about 13.2% encoding time reduction with 1.0% BD-rate increase on average over test sequences in HM 12.0.

An Experimental Study on Exhaust Gas Reduction of Diesel Oxidation Catalyst by CVS-75 Mode in Light Duty Diesel Engine (小型디젤機關에서 CVS-75 모드에 따른 디젤 酸化觸媒裝置의 排出가스 低減에 關한 實驗的 硏究)

  • 한영출;김종춘;오용석
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.4
    • /
    • pp.457-461
    • /
    • 1999
  • Recently, increasing usage of diesel vehicle, many countries try to reduce the pollutant materials by emission regulation standard. Particularly, in our country, the supplement ratio of diesel vehicle is high, and air pollution by particulate matter(PM) is very serious. So, in theoretical study wer analyzed the formation principle of gaseous emission and PM, the characteristics of CVS-75 mode. In experimental study, we tested exhaust gas reduction of emission and PM, the characteristics of CVS-75 mode. In experimental study, we tested exhaust gas reduction of disel oxidation catalyst(DOC) by CVS-75 mode in light duty diesel vehicle. In case of an automobiletest with the 2,956cc diesel engine which DOC was equipped, CVS-75 mode which is similar to driving conditions on the road was chosen as the restrictive mode of light duty diesel automobile in our country. According to the Pt, the reduction rate of exhaust emission was estimated with using 0.1% high sulfur fuel and 0.05% low sulfur fuel.

  • PDF

Fast intra prediction mode decision based on rough mode decision and most probable mode in HEVC (HEVC에서 Rough mode decision과 Most probable mode에 기반을 둔 고속 인트라 예측 모드 결정 방법)

  • Lee, Seung-ho;Park, Sang-hyo;Jang, Euee Seon
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2013.11a
    • /
    • pp.71-74
    • /
    • 2013
  • 차세대 동영상 표준 코덱인 High Efficiency Video Coding(HEVC)은 기존의 AVC/H.264 보다 동일 화질 대비 최대 약 2배의 압축 성능을 보여준다. 이러한 HEVC의 성능을 얻기 위하여 복잡한 연산이 많은 기법이 도입되었고 이로 인하여 HEVC의 시간 복잡도는 AVC/H.264보다 더욱 증가하였다. HEVC의 시간 복잡도를 줄이기 위해서 다양한 고속 알고리즘이 논의되고 있고 인트라 예측 모드에서의 고속 알고리즘 연구 또한 많은 연구가 이루어지고 있다. 본 논문에서는 인트라 예측 모드 결정과정에서 HEVC에 구현된 Rough mode decision(RMD)와 Most probable mode(MPM)의 결과를 활용하여 고속화된 최종예측 모드 결정 방법을 제안한다. 실험 결과, HM 10.0의 All Intra 환경을 기준으로 BD-rate에서 약 0.9%의 손실과 함께 평균 24%의 속도 향상을 얻을 수 있었다.

  • PDF

The effect of working parameters on removal of casting gold alloy using a piezoelectric ultrasonic scaler with scaler tip in vitro (압전방식 초음파 치석제거기의 작업조건에 따른 치과주조용 합금의 삭제에 관한 연구)

  • Cha, Kuk-Bong;Kim, Won-Kyung;Lee, Young-Kyoo;Kim, Young-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.2
    • /
    • pp.139-148
    • /
    • 2009
  • Purpose: Ultrasonic scalers have been widely used for removing biofilm which is considered as major etiologic factor of periodontal disease. The purpose of this study was to evaluate the effect of working parameters of piezoeletric ultrasonic scaler with scaler tip (No. 1 tip) on casting gold alloy removal. Methods: Type III dental casting gold alloy (Firmilay$^{circledR}$, Jelenko Inc, CA, USA) was used as substitute for tooth substance. Piezoeletric ultrasonic scaler and No.1 scaler tip (P-Max$^{circledR}$, Satelec, France) were selected. The selected working parameters were mode (P mode, S mode), power setting (2, 4, 8) and lateral force (0.5 N, 1.0 N, 2.0 N). The effect of working parameters was evaluated in terms of ablation depth, ablation width and ablation area. Results: Mode influenced ablation depth and ablation area. Power also influenced ablation depth and ablation area. Especially, Power 2 and power 8 showed statistically significant difference. Lateral force had influence on ablation width, and 0.5 N resulted significant increase compared with 1.0 N and 2.0 N. Ablation depth was influenced by mode, power and lateral force and defect width was influenced by lateral force. Ablation area was influenced by mode and power. Conclusions: It can be concluded that the use of piezoelectric ultrasonic scaler with No. 1 scaler tip in S mode and high power may result in significant loss of tooth substance.

The Effect of Construction Methods on Geothermal Exchange Rates of Cast-in-place Energy Piles (현장타설말뚝형 에너지 파일의 시공형태별 지중 열교환량에 관한 연구)

  • Park, Yong-Boo;Nam, Yu-Jin;Sim, Young-Jong;Sohn, Jeong-Rak
    • Land and Housing Review
    • /
    • v.3 no.2
    • /
    • pp.169-175
    • /
    • 2012
  • In recent, there are many studies associated with energy piles to save initial construction cost for ground source heat pump system. In this study, to evaluate geothermal exchange rates two types (a connection type and a slinky type) of cast-in-place energy piles (PRD, 4.5m in depth, 1,200 mm in diameter) were constructed for the tests and their efficiencies were compared with numerical analysis results. As a result, starting with operation, geothermal exchange rate gradually decreases due to exchange of lower ground temperature. In the case of connection type, temperature difference is $0.37^{\circ}C$ in heating mode and $0.34^{\circ}C$, in cooling mode, respectively. In addition, in case of a connection type, geothermal exchange rate in heating mode is 2,314W/m and in cooling mode, 252.2W/m whose value is 9% higher than in heating mode. In the case of slinky type, the average geothermal exchange rate in heating mode is 168.0W/m, which is about 27% lower than that of connection type.

Effect of Grating Phase in DFB Lasers with an Anti-reflection Coated Mirror (AR 코팅된 DFB 레이저에서 격자 위상의 영향)

  • Kwon, Kee-young;Ki, Jang-geun;Cho, Hyun-mook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.463-468
    • /
    • 2021
  • In this paper, when a refractive index grating and a gain grating were simultaneously present in a DFB laser having a wavelength of 1.55 ㎛, a dielectric film coating was applied so that reflection did not occur on the right mirror surface, so that 𝜌r=0. In case of 𝛿L>0, the characteristics of the oscillation frequency and oscillation gain were analyzed. When the grating phase of the left mirror surface continues to decrease from 𝜋, the graph lines of each mode gradually shift to the left. In case of 𝜅L=10, the threshold gain of the oscillation mode is the lowest. In this case, the mode selectivity is relatively low. From 𝜅L=0.5 to 𝜅L=6, the mode selectivity and the frequency stability are excellent. In the case of DFB lasers with an anti-reflection coated mirror, the threshold gain of the oscillation mode increases but the mode selectivity is about twice as excellent, compared with DFB lasers of having two cleaved facets.

Comparison on the Error Rates of Calibration Modes in Intervention (인터벤션에서 Calibration Mode에 대한 오차율 비교)

  • Kong, Chang gi;Ryu, Young hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.619-626
    • /
    • 2020
  • This study aimed to identify the error rates in Catheter Calibration Mode, Auto Calibration Mode, and Segment Calibration Mode among many calibration modes as a quantitative evaluation tool used for predicting the diameter and length of balloon or stent in percutaneous intravascular balloon dilatation or stent insertion. Our experiment was conducted with Copper Wire of 2 mm × 80 mm (diameter × length) manufactured elaborately for quantitative evaluation in calibration and Metal Ball of 5, 10, 15, 30, and 40 mm and Acryl Phantom of 25 mm, 50 mm, 75mm, 100 mm, 125 mm, 150mm, 175 mm, and 200 mm. At each height, subtraction images were acquired with a cineangiograph and Stenosis Analysis Tool as a software provided by the equipment company was used for measurement. To evaluate the error rates in Catheter Calibration Mode, Copper Wire was put on each acryl phantom before shooting. Copper Wire of 2 mm in diameter was set as a diameter for catheter, and Copper Wire of 8 mm in length was measured with Multi-segments. As a result, the error rates appeared at 1.13 ~ 5.63%. To evaluate the error rates in Auto Calibration Mode, the height of acryl was entered at each height of acryl phantom and the length of 8 mm Copper Wire was measured with Multi-segments and as a result, the error rates appeared at 0 ~ 0.26%. To evaluate the error rates in Segment Calibration Mode, each metal ball on the floor of table was calibrated and the length of 8 mm Copper Wire on each acryl phantom was measured and the length of 8 mm Copper Wire depending on the changes of acryl phantom height was measured with Mutli-segments and as a result, the error rates appeared at 1.05 ~ 19.04%. And in the experiment on OID changes in Auto Calibration Mode, the height of acryl phantom was fixed at 100mm and OID only changed within the range of 450 mm ~ 600 mm and as a result, the error rates appeared at 0.13 ~ 0.38%. In conclusion, it was found that entering the height values in Auto Calibration Mode, among these Calibration Modes for evaluating quantitative vascular dimensions provided by the software was the calibration method with the least error rates and it is thus considered that for calibration using a metal ball or other objects, putting them in the same height as that of treatment sites before calibrating is the method that can reduce the error rates the most.

A Study on Failure Mode and Effect Analysis (FMEA) for Preoperative Risk Prevention (오류유형 영향분석(FMEA)을 적용한 수술준비 위험예방활동의 효과)

  • Kim, Chang Hee;Lee, Mi Hyang
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.22 no.5
    • /
    • pp.415-423
    • /
    • 2016
  • Purpose: The purpose of this research was to provide patients with safe preoperative preparatory procedures by removing any risk factors from the preparatory procedures by using failure mode and effects analysis, which is a prospective risk-managing tool. Methods: This was a research design in which before and after conditions of a single group were studied, Failure mode and effects analysis were applied for the preparatory procedures done before operations. Results: The preparation omission rate before the operation decreased from 2.70% to 0.04%, and operation cancellation rate decreased from 0.48% to 0.08%. Conclusion: Failure mode and effects analysis which remove any risk factors for patients in advance of the operation is effective in preventing any negligent accidents.

Study of the non-linearity of cable damper to enhance damping performance of stay cable (사장교 케이블의 감쇠성능 향상을 위한 댐퍼의 비선형성 연구)

  • Seo, Ju-Won;Koh, Hyun-Moo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.147-156
    • /
    • 2007
  • This study offers a design procedure of optimum cable damper for multi-mode vibration control with nonlinear damper and also investigate the relation between mode and amplitude dependency. The proposed multi-mode damping index, which is defined as a energy loss ratio of cable potential, is a main component of optimization problem of optimum nonlinear damper. In order to include the amplitude dependency of nonlinear damper, it is assumed to exist three kinds of multi-mode patterns such as ambient vibration, support excitation and rain-win induced vibration. The optimum damper exponent depends on amplitude patterns. In case of ambient vibration, optimum factor is less than 0.5. In case of support excitation or rain-wind induced vibration is between 0.5 and 1.0. In this study, the effects of cable sag and inclination angle are included in the asymptotic design equation of damped cable structures.

  • PDF

Study of the Non-linearity of Cable Damper to Enhance Damping Performance of Stay Cable (사장교 케이블의 감쇠성능 향상을 위한 댐퍼의 비선형성 연구)

  • Seo, Ju-Won;Koh, Hyun-Moo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.9
    • /
    • pp.785-796
    • /
    • 2007
  • This study offers a design procedure of optimum cable damper for multi-mode vibration control with nonlinear damper and also investigates the relation between mode and amplitude dependency. The proposed multi-mode damping index, which is defined as a potential energy loss ratio of cable vibration, is a main component of optimization problem of optimum nonlinear damper. In order to include the amplitude dependency of nonlinear damper, three types of multi-mode patterns such as ambient vibration, support excitation and rain-wind induced vibration are assumed. The optimum damper exponent depends on amplitude patterns. In case of ambient vibration, optimum factor is less than 0.5 and in case of support excitation or rain-wind induced vibration it is between 0.5 and 1.0.