• 제목/요약/키워드: -1 Mode

검색결과 9,760건 처리시간 0.044초

파노라마 촬영시의 두경부 주요기관의 등가선량, 유효선량 및 위험도 (EQUIVALENT DOSE, EFFECTIVE DOSE AND RISK ASSESSMENT FROM PANORAMIC RADIOGRAPHY TO THE CRITICAL ORGANS OF HEAD AND NECK REGION)

  • 조봉혜;나경수;이애련
    • 치과방사선
    • /
    • 제25권2호
    • /
    • pp.437-445
    • /
    • 1995
  • The purpose of this study was to evaluate the equivalent and effective dose, and estimate radiation risk to the critical organs of head and neck region from the use of adult and child mode in panoramic radiography. The results were as follows. 1. The salivary glands showed the highest equivalent and effective dose in adult and child mode. the equivalent and effective dose in adult mode were 837μSv and 20.93μSv, those in child mode were 462μSv and 11.54μSv, respectively. 2. Total effective doses to the critical head and neck organs were estimated 34.21μSv in adult mode, 20.14μSv in child mode. From these datas, the probabilities of stochastic effect from adult and child mode were 2.50x10/sup -6/ and 1.47x10/sup -6/. 3. The other remainder showed the greatest risk of fatal cancer. The risk estimate were 4.5 and 2.7 fatal malignancies in adult and child mode from million panoramic examinations. The bone marrow and thyroid gland showed about 0.1 fatal cancer in adult and child mode from these examinations.

  • PDF

접착이음의 계면균열에 대한 파괴인성 및 평가방법 (Mehods of Fracture Toughness and Evaluation for Interface Crack in Adhesively Bonded Joints)

  • 정남용
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 춘계학술대회 논문집
    • /
    • pp.220-226
    • /
    • 1998
  • In this pater, a method of strength evaluation applying fracture mechanics in adhesively bonded joints of A1/A1 materials was investigated. Various adhesively bonded joints of double-cantilever beam with a interfacial crack in its adhesive layer were prepared for the fracture toughness test of comprehensive mixed mode conditions from nearly pure mode I to mode II. The experiment of fracture toughness was carried out under various mixed mode conditions with an interfacial crack and critical energy release rate, Gc by the experimental measurements of compliances was determined. From the results, fracture toughness on mixed mode with an interfacial crack is well characterized by strain energy release rate and a method of strength evaluation by the fracture toughness in adhesively bonded joints of A1/A1 materials was discussed.

  • PDF

모드변환 가능한 단권변압기를 이용한 CMOS 전력증폭기 (CMOS Power Amplifier Using Mode Changeable Autotransformer)

  • 류현식;남일구;이동호;이옥구
    • 전자공학회논문지
    • /
    • 제51권4호
    • /
    • pp.59-65
    • /
    • 2014
  • 본 논문에서는 전력증폭기의 효율을 증가시키기 위해서 모드변환 가능한 단권변압기를 제안한다. 모드변환 가능한 단권변압기를 통해 전력증폭기의 저 전력 모드 동작 시 효율을 개선할 수 있다. 이 논문에서는 0.18-${\mu}m$ CMOS 표준 공정을 이용하여 듀얼모드 단권변압기를 이용한 CMOS 전력증폭기를 설계하였다. 고 전력 모드와 저 전력 모드에서 단권변압기의 1차 권선의 권선수를 조절하여 전력증폭기의 동작을 최적화하였다. EM 시뮬레이션 및 전체 회로 시뮬레이션 결과 제안된 멀티모드 CMOS 전력증폭기의 출력전력이 24dBm일 때 전력부가효율(PAE)이 10.4%에서 멀티모드 동작으로 26.1% 로 상승하여 전력증폭기의 성능 개선되었다.

H.264 / MPEG-4 AVC에서의 B 픽쳐를 위한 시간적 다이렉트 모드 (Temporal Directmode for B Picture in H.264 / MPEG-4 AVC)

  • 전병문
    • 방송공학회논문지
    • /
    • 제7권4호
    • /
    • pp.300-309
    • /
    • 2002
  • 본 논문은 H.264 / MPEG-4 AVC 비디오 코덱에서 쌍예측 픽쳐의 시간적 다이렉트 모드의 모션벡터를 유포하는 방법을 소개한다. 우선, 다이렉트 모드의 list 1 레퍼런스 픽쳐에 있는 동일 위치 블록에서의 시간적 다이렉트 모드의 모션벡터 유포를 위해 사용될 모션벡터 결정 방법과 상기 결정된 모션벡터가 가리키는 레퍼런스 픽쳐를 다이렉트 모드의 list 0 레퍼런스 픽쳐로 결정하는 방법을 제시한다. 또한 동일 위치의 매크로블록이 인트라 모드를 예측모드로 가지고 있을 때, 코딩 효율을 높이기 위한 방법으로써 레퍼런스 픽쳐 인덱스 및 다이렉트 모드의 모션벡터를 공간적으로 예측하는 기법을 제시한다. 그리고, 쌍예측 픽쳐 매크로블록과 다이렉트 모드의 list 1 레퍼런스 픽쳐에 있는 동일 위치 블록은 프레임 모드 또는 피일드 모드로 코딩이 이루어질 수 있으므로 4가지 경우에 대한 다이렉트 모드의 모션벡터 연산 방법을 소개한다. 마지막으로, 실험을 통한 공간적 다이렉트 모드와의 성능평가 결과를 보임으로써, 본 논문이 제시한 기법이 H.264 / MPEG-4 AVC의 시간적 다이렉트 모드에 적용될 수 있음을 보여준다.

Temperature effects on brittle fracture in cracked asphalt concretes

  • Ayatollahi, Majid-Reza;Pirmohammad, Sadjad
    • Structural Engineering and Mechanics
    • /
    • 제45권1호
    • /
    • pp.19-32
    • /
    • 2013
  • Cracking at low temperatures is one of the frequently observed modes of failure in asphalt concretes. In this investigation, fracture tests were performed on cracked asphalt concrete subjected to pure mode I and pure mode II loading at different subzero temperatures. An improved semi-circular bend (SCB) specimen containing a vertical crack was used to conduct the experiments. The SCB specimens produced from the gyratory compacted cylindrical samples were compressively loaded, and critical stress intensity factors, $K_{If}$ and $K_{IIf}$, were then calculated using peak loads obtained from the tests. The experimental results showed that with decreasing the temperature, mode I and mode II critical stress intensity factors increased first but below a certain temperature they both decreased. It was also found that at a fixed temperature, the mode II fracture resistance of the asphalt concrete was higher than its mode I fracture resistance.

Mode Selection of Leaky Lamb Waves in Steel Plate

  • ;;;나원배
    • 한국해양공학회지
    • /
    • 제22권1호
    • /
    • pp.6-12
    • /
    • 2008
  • The dispersion and attenuation of Lamb and Leaky Lamb waves propagating in a 1 mm-thick steel plate were investigated. For acquiring a long(or large) range inspection capability, the fundamental symmetric and anti-symmetric wave modes(S0 and A0) over law frequencies were studied. Based on the dispersion curves, as well as pitch-catch and multi-mode simulations, it was shown that the S0 mode over law frequencies is the proper mode to minimize the dispersion and attenuation. In addition, it was shown that the S0 mode couldbe easily distinguished under multi-mode simulation since it has a larger group velocity than the A0 mode.

헬리콘 플라즈마의 전기적 특성 (Electrical Characteristics of Helicon Wave plasmas)

  • 윤석민;김정형;서상훈;장흥영
    • 한국진공학회지
    • /
    • 제5권1호
    • /
    • pp.85-92
    • /
    • 1996
  • The external electricla characteristics of helicon wave plasmas were measured over a wide range of RF power and magnetic filed. External parameters. such as antenna voltage , current, phase shift, and interanl parameter, electron density were measured at 7MHz, 1mTorr Ar discharge . The equivalent discharge resistance and reactance, and the power transfer efficiency were calculated through these measurements. There are a helicon mode which produces high density plasma by helicon wave and a lowmode which produces low density plasma by capaictive electric field. In case of the helicon mode, the anternna voltage and current were lower than those of the low-mode. The phase difference between voltage and current decreased suddenly at the transition point from the low-mode to the helicon mode. Equivalent resistance and power efficiency increased and reactance decreased suddenly at the transition point. These results mean that the power transperred to plasma and the nutual coupling between the antenna and plasma increase as the mode changes from the low-mode to the helicon mode.

  • PDF

Stability analyses of dual porosity soil slope

  • Satyanaga, Alfrendo;Moon, Sung-Woo;Kim, Jong R.
    • Geomechanics and Engineering
    • /
    • 제28권1호
    • /
    • pp.77-87
    • /
    • 2022
  • Many geotechnical analyses require the investigation of water flow within partially saturated soil zone to incorporate the effect of climatic conditions. It is widely understood that the hydraulic properties of the partially saturated soil should be included in the transient seepage analyses. However, the characteristics of dual porosity soils with dual-mode water retention curve are normally modelled using single-mode mathematical equation for simplification of the analysis. In reality, the rainwater flow can be affected significantly by the dual-mode hydraulic properties of the soil. This paper presents the variations of safety factor for dual porosity soil slope with dual-mode water retention curve and dual-mode unsaturated permeability. This paper includes the development of the new dual-mode unsaturated permeability to represent the characteristics of soil with the dual-mode water retention curve. The finite element analyses were conducted to examine the role of dual-mode water retention curve and dual-mode unsaturated permeability on the variations of safety factor under rainfall loading. The results indicate that the safety factor variations of dual porosity soil slope modelled using the dual-mode water retention curve and the unsaturated permeability equation are lower than those of dual porosity slope modelled using single-mode water retention curve and unsaturated permeability equations.

훈련기 스핀모드 향상을 위한 수직 풍동시험 (The Vertical Wind Tunnel Test for Spin Mode Improvement of KTX-1)

  • 고준수;정인재
    • 제어로봇시스템학회논문지
    • /
    • 제11권3호
    • /
    • pp.228-232
    • /
    • 2005
  • This paper presents the efforts of the studies for improvement of spin characteristics of KTX-1 #02 through rotary balance test, forced oscillation test and spin mode analysis. During the full scale development design stage, we had fullfilled a lot of spin flight test, spin mode analysis. Based on all of the efforts, KTX-1 had been developed as a successful trainer with excellent spin characteristics.

천부지각 2차원 속도구조를 위한 레일리파의 군속도와 위상속도 역산의 비교 연구 (A Study of the comparison of Inversion of Rayleigh wave Group and Phase Velocities for Regional Near-Surface 2-Dimensional Velocity Structure)

  • 이보라;정희옥
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2006년도 공동학술대회 논문집
    • /
    • pp.51-59
    • /
    • 2006
  • 서해안 조간대에서 24 channel 탐사기로 획득한 표면파 자료의 위상속도와 군속도를 구한다음, 이를 역산하여 그 결과를 비교하였다. 위상속도의 분산곡선은 tau-p stacking 방법에 의하여, 군속도의 분산곡선은 wavelet analysis와 Multiple Filtering Technique의 두가지 방법을 사용하여 구하였다. 위상속도의 오차가 군속도의 오차보다 더 큰 것을 확인하였다. 군속도의 경우, wavelet analysis가 Multiple Filtering Technique 보다 fundamental mode와 higher mode를 구분하는데 더 효과적이었다. 역산결과, 군속도의 fundamental mode와 1st higher mode 를 동시에 사용했을 때, 공간적 해상도가 가장 좋았다. 이연구는 천부 지반의 S파 속도 구조를 구하는데, 군속도의 higher mode를 포함한 군속도 분산곡선을 사용하는 것이 효과적임을 시사한다.

  • PDF