• Title/Summary/Keyword: -1 Mode

Search Result 9,719, Processing Time 0.037 seconds

Dose and Image Evaluation of Pediatric Head Image according to CT Scan Mode and kVp Changes (CT Scan Mode와 관전압 변경에 따른 소아 두부 영상의 선량 및 영상평가)

  • Byeong-Je Kim;Dong-Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.801-808
    • /
    • 2023
  • In order to minimize radiation exposure and secure diagnostic value images during CT examination of the head of children, the usefulness of volume axial mode is evaluated through comparison and analysis of exposure dose and images of volume axial mode, high pitch mode, and helical mode. Image evaluation and dose evaluation were performed in CT high pitch mode, helical mode, and volume axial mode for infants under the age of 1 according to the voltages of 70, 80, and 100 kVp tubes. The image evaluation was conducted by comparing image quality by setting ROI for each image, calculating SNR and CNR, using ONE-WAY (ANOVA) to evaluated statistical significance, and cross-examining the dose evaluation using DLP values displayed in the Dose Report. When inspected using volume axial mode, DLP values were generally low, and SNR and CNR values differed by ROI and kVp. When volume axial mode evaluated the quality of the image compared to other scan modes, the difference is not uniform. For the reason, certain modes are not considered excellent, but the exposure dose was reduced the most in terms of dose. In addition, the point that the volume axial mode can be examined at its original location, short scanning time and needless of table movement is useful for CT tests for children under 1 year of age with high radiation sensitivity.

Design and analysis of a mode size converter composed of periodically segmented taper waveguide (주기적으로 분리된 광도파로로 구성된 모드 크기 변환기의 설계 및 분석)

  • 박보근;정영철
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.22-27
    • /
    • 2004
  • In this paper, we designed a mode size converter to reduce coupling loss between optical waveguide and single mode fiber. The proposed mode converter is composed of periodically segmented tapered waveguide to achieve small size and easy fabrication. For the optimally designed mode size converter at 1550nm, the taper length is 500(equation omitted), the segmentation period 5ß:, the waveguide width of fiber contact section 1.3ß:, and duty cycle 0.95. The coupling loss of the optimized mode size converter is 0.33㏈/point, which is 1.27㏈/point lower than that without the mode size converter.

Feasibility study on an acceleration signal-based translational and rotational mode shape estimation approach utilizing the linear transformation matrix

  • Seung-Hun Sung;Gil-Yong Lee;In-Ho Kim
    • Smart Structures and Systems
    • /
    • v.32 no.1
    • /
    • pp.1-7
    • /
    • 2023
  • In modal analysis, the mode shape reflects the vibration characteristics of the structure, and thus it is widely performed for finite element model updating and structural health monitoring. Generally, the acceleration-based mode shape is suitable to express the characteristics of structures for the translational vibration; however, it is difficult to represent the rotational mode at boundary conditions. A tilt sensor and gyroscope capable of measuring rotational mode are used to analyze the overall behavior of the structure, but extracting its mode shape is the major challenge under the small vibration always. Herein, we conducted a feasibility study on a multi-mode shape estimating approach utilizing a single physical quantity signal. The basic concept of the proposed method is to receive multi-metric dynamic responses from two sensors and obtain mode shapes through bridge loading test with relatively large deformation. In addition, the linear transformation matrix for estimating two mode shapes is derived, and the mode shape based on the gyro sensor data is obtained by acceleration response using ambient vibration. Because the structure's behavior with respect to translational and rotational mode can be confirmed, the proposed method can obtain the total response of the structure considering boundary conditions. To verify the feasibility of the proposed method, we pre-measured dynamic data acquired from five accelerometers and five gyro sensors in a lab-scale test considering bridge structures, and obtained a linear transformation matrix for estimating the multi-mode shapes. In addition, the mode shapes for two physical quantities could be extracted by using only the acceleration data. Finally, the mode shapes estimated by the proposed method were compared with the mode shapes obtained from the two sensors. This study confirmed the applicability of the multi-mode shape estimation approach for accurate damage assessment using multi-dimensional mode shapes of bridge structures, and can be used to evaluate the behavior of structures under ambient vibration.

Mode Control Design of Dual Buck Converter Using Variable Frequency to Voltage Converter (주파수 전압 변환을 이용한 듀얼 모드 벅 변환기 모드 제어 설계)

  • Lee, Tae-Heon;Kim, Jong-Gu;So, Jin-Woo;Yoon, Kwang-Sub
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.4
    • /
    • pp.864-870
    • /
    • 2017
  • This paper describes a Dual Buck Converter with mode control using variable Frequency to Voltage for portable devices requiring wide load current. The inherent problems of PLL compensation and efficiency degradation in light load current that the conventional hysteretic buck converter has faced have been resolved by using the proposed Dual buck converter which include improved PFM Mode not to require compensation. The proposed mode controller can also improve the difficulty of detecting the load change of the mode controller, which is the main circuit of the conventional dual mode buck converter, and the slow mode switching speed. the proposed mode controller has mode switching time of at least 1.5us. The proposed DC-DC buck converter was implemented by using $0.18{\mu}m$ CMOS process and die size was $1.38mm{\times}1.37mm$. The post simulation results with inductor and capacitor including parasitic elements showed that the proposed circuit received the input of 2.7~3.3V and generated output of 1.2V with the output ripple voltage had the PFM mode of 65mV and 16mV at the fixed switching frequency of 2MHz in hysteretic mode under load currents of 1~500mA. The maximum efficiency of the proposed dual-mode buck converter is 95% at 80mA and is more than 85% efficient under load currents of 1~500mA.

How Does the Presentation Mode of Product Information Affect Product Evaluation? : The Mediation of Construal Level and the Moderation of Response Time

  • Cho, Hyun Young
    • International Journal of Contents
    • /
    • v.16 no.1
    • /
    • pp.44-56
    • /
    • 2020
  • The purpose of this study was to examine how the presentation mode (sequential- vs. simultaneous-mode) of information influences its evaluation. Three experiments revealed the interaction effect between the presentation mode and the valence of the product information. When respondents read about the positive aspects of the product, the evaluation was higher in the simultaneous presentation mode than in the sequential presentation mode. For negative product information, respondents' evaluation was higher in the sequential presentation mode than in the simultaneous presentation mode. The simultaneous presentation mode intensified the impact of the information valence on evaluation. This study proposed that the sequential and the simultaneous presentation modes prime high and low construal levels, respectively. The mediation analysis provides support for such a prediction. Finally, the mediating effect of construal levels in evaluation was shown to disappear when respondents focused on the product information for a longer duration, while the mediation effect remained when the response time was short.

Development Of Virtual Reality System For The Training And Assessment Of Proprioception During Upper-limb Reaching Task: A Pilot Study (상지재활 훈련동안 자기수용감각의 훈련 및 평가를 위한 가상현실 시스템 개발: 예비연구)

  • Cho, Sang-Woo;Ku, Jeong-Hun;Han, Ki-Wan;Lee, Hyeong-Rae;Park, Jin-Sick;Lee, Won-Ho;Shin, Young-Seok;Kim, Hong-Joon;Kang, Youn-Joo;Kim, In-Young;Kim, Sun-I.
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.749-753
    • /
    • 2008
  • Proprioception defined it as the ability to detect, the spatial position or movement of joints using balance, power of the muscle, agility in the internal parts of the body. In existing study for improvement of proprioception, reaching task training provided a feedback; the assessment was not provided a feedback. But, this has problem that it can not guide a proprioception from situation with visual feedback. Virtual reality technique can solve the problem of way providing feedback during training. In this study, we developed proprioception training program using virtual reality and pilot study is performed. VR task were composed three modes. In mode 1, real-time movement of the body was provided using visual feedback. In mode 2, body position was provided using visual feedback when participant have specific response. And in mode 3, body position was not provided. VR task is performed five sessions at each mode and one session performed one by one a three target. In the result of this study, the moving time toward the target from mode 3 was smaller than the moving time toward the target from mode 1 (p= 0.001). The correlation was statistically significant between mode 2 and mode 3 while be offering visual feedback position of mode 2 1session. But, the correlation was not statistically significant between mode 2 and mode 3 after be offered visual feedback position of mode2 1session (p = 0.012). Training environment of mode 1 shows which training used visual feedback than proprioception. Mode2 can execute training of proprioception because first session acquires visual feedback by proprioception. The next study will be verification of the system for training or assessment by clinical experiment.

  • PDF

A Study on Standardization on the Flight Controller Mode in Remotely Piloted Aircraft Drone : Focused on Drone Controller Mode Preference (원격조종항공기 드론 조종기모드 표준화 연구 : 드론 조종기모드 선호도를 중심으로)

  • Park, Wontae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.4
    • /
    • pp.69-75
    • /
    • 2019
  • Remotely Piloted Aircraft (RPA) controls as a type of unmanned aerial vehicle (drone) is growing rapidly and its flight controller stick disposition is required standardization. We should standardize RPA drone flight control disposition because the flight pilot of RPA is hard to be trained so the flight controller stick differences impairs safety and wastes time and effort of flight controller industry. So this study researches the on-going standardization of RPA drone flight control disposition in Korea and foreign countries. Also this paper analyzes and researches of expert about RPA drone flight controller function and application of flight control mode. I accomplished expert research about standardization plan of unmanned flight control mode and confirm the necessity. Nowadays mode1 and 2 are mostly used in Korea so I carried out preference investigation for two modes. There were 4 preferences choices of RPA drone control mode necessity (importance) and recommendation of standardization modes. They answered that necessity of standardization is important considering pilot training, flight safety and positive development of drone industry. The result of standardization mode preference is that they prefer mode 2 (drone maker 86%, training facilities and research facilities 58%, government bureau 60%). Overall preference result shows that mode 1 24%, mode 1&2 16%, mode 2 60%. So they preferred mode 2 by 60%. The differences between two modes are the direction of throttle and pitch. Direction of throttle and pitch operate opposite way. They prefer mode 2 because mode 2 has similarities of manned flight control mode. Significance of this study is that it showed the necessity of standardization and flight control preference in a quantitative way. It will help drone standardization in related industries and development direction near future.

Attenuation of Fundamental Longitudinal Guided Wave Mode in Steel Pipes Embedded in Soil

  • Lee, Ju-Won;Shin, Sung-Woo;Na, Won-Bae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.6
    • /
    • pp.539-547
    • /
    • 2010
  • In this study, characteristics of the fundamental longitudinal guided wave mode, L(0,1), which is a usual mode employed in the inspection of the above-ground pipe, of the buried pipe were numerically investigated considering property changes in the surrounding soil. Results showed that soil conditions are significantly affecting the attenuation of L(0,1) mode in the pipe embedded in soil. Especially, if the soil is partially saturated, the attenuation of L(0,1) mode is larger and is very similar regardless of the degree of water saturation in the surrounding soil. However, when the soil is fully saturated, the attenuation of L(0,1) mode is less and show different trend with its partially saturated counterparts.

Mixed Mode Interlaminar Fracture Behaviors of Carbon Fabric/Epoxy Composites (탄소섬유직물/에폭시 복합재의 혼합모우드 층간파괴 거동)

  • Yoon, Sung-Ho;Heo, Kwang-Soo;Oh, Jin-Oh
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.1
    • /
    • pp.58-65
    • /
    • 2007
  • Mixed mode interlaminar fracture behaviors of carbon fabric/epoxy composites were investigated through MMF (Mixed Mode Flexural) test by varying mixed mode ratio ranging from 20% to 90%. Mixed mode interlaminar fracture criteria based on NL point and 5% offset point were also suggested in order to predict mixed mode interlaminar fracture behaviors. Fracture surfaces and crack propagating behaviors were examined through a travelling scope and a scanning electron microscope. According to the results, mixed mode interlaminar fracture behaviors can be predicted by mixed mode interlaminar fracture criterion with m=1.5 and n=0.5 on the basis of NL point or mixed mode interlaminar fracture criterion with m=2 and n=3 on the basis of 5% offset point. Fracture surfaces and crack propagating behaviors are sensitive to mixed mode ratios. MMF test can be successfully applicable in evaluating mixed mode interlaminar fracture toughness of carbon fabric/epoxy composites.

Effects of Soaansintang(SOAT) on the hemodynamics and electrocardiogram of isolated rat hearts induced by electrical stimulation (소아안신탕(小兒安神湯)이 STRESS를 유발한 흰쥐의 적출심장(摘出心臟)에 미치는 영향)

  • Lee Seung-Jun;Lee Jin-Yong;Kim Deok-Gon
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.14 no.2
    • /
    • pp.1-32
    • /
    • 2000
  • It has long been known that SOAT is effective for sudden palpitation occurring unexpectedly in Oriental Medicine. However, effect of SOAT on the isolated heart has not been studied yet. The purpose of this study is to investigate the effect of SOAT on hemodynamics and ECG of isolated rat hearts induced by electrical stimulation using Langendorff perfusion apparatus for nonworking heart. SOAT extract was manufactured by water-alcohol precipitated method. Sprague-Dawley rats weighting $120{\sim}150g$ were used for the experiments, Subject animals were divided into four groups, which are consisted of 1) control(Group orally administered by normal saline 1ml for 14days), 2) sample A(Group orally administered by SOAT extract 1ml for 14days), 3) sample C(Group injected by SOAT extract 0.5ml after stimulation, 4) sample C(Group injected by SOAT extract 1ml after stimulation. To evluate the effects of SOAT on hemodynamics and ECG of isolated rat heart induced by stimulation, heart rate, left ventricular pressure, systolic power, diastolic power, coronary artery perfusion volume and ECG were measured using Langendorff apparatus in both stimulation mode(5 volts, 450 beats/min) and arrythmic mode(5 volts, 420 beats/min including 60 beats/min) The results obtained are as follows : 1. After receiving stressful electrical stimuli, isolated heart showed the heart rate, left ventricular pressure, systolic power, diastolic power, coronary artery perfusion volume were all decreased temporarily, but perfusion continued longer recovery to the control state appeared. However, the coronary artery perfusion volume diminished continuously. 2. The heart rates did not change significantly with both stimulation mode and arrhythmic mode, among experimental groups. 3. The left ventricular pressure showed with both stimulation mode and arrhythmic mode, the significant changes(p<0.05) especially in the injection sample group. In case of stimulation mode, low concentration injection group(0.5ml) was more significantly increased rather than high concentration group(1ml) and in case of arrhythmic mode, high density group(1ml) was so increased than the other(0.5ml). 4. For the systolic power and diastolic power, no significant changes were noticed in the stimulation mode, but in the arrhythmic mode of injection sample groups, significant change(p<0.05) was noticed in both systolic power and diastolic power. Specially the high concentration group(1ml) showed more significant increase than the low concentration group. 5. For the coronary artery perfusion volume, no significant change difference among sample groups was observed in both the stimulation mode and the arrhythmic mode. 6. For the ECG recordings, arrhythmia was induced by electrical stimulus of arrythmia mode and after the stimulus was removed, irregular wave appeared temporarily, but as perpusion continued, recovery to the control state was abtained like the stimulation mode. According to the above results, SOAT significantly changed the hemodynamic data from the electrically stressed, isolated hearts of connected Langendorff perfusion apparatus and we propose SOAT has the direct effects on the muscular function of heart.

  • PDF