• Title/Summary/Keyword: -1 Mode

Search Result 9,719, Processing Time 0.044 seconds

Effects of coarse mode aerosol on the size distribution by coagulation and condensation processes (응집 및 응축과정에 의한 대기 에어로졸 크기 분포에서의 coarse mode의 영향)

  • 정창훈;김용표;이규원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.158-159
    • /
    • 2000
  • 내기중의 입자 (aerosol)는 크게 직경이 0.01-0.1 $\mu\textrm{m}$ 대의 Aitken mode와 0.1-1 $\mu\textrm{m}$ 부근의 accumulation mode, 그리고 1 $\mu\textrm{m}$ 이상의 coarse mode로 분류할 수 있으며 대기 중에서 부유하여 서로응집(coagulation) 과 응축(condensation)풍의 과정을 겪으며 변화한다. 일반적으로 Aitken mode 의 입자들은 nucleation 둥에 의해 발생된 입자이며, accumulation mode는 Aitken mode입자간의 응집, 인위적인 배출 둥에 의하여 생성된 입자이다. Coarse mode는 주로 자연적으로 생성된 입자이며 주로 침적에 의해 제거된다. (중략)

  • PDF

다목적실용위성 1호 Maneuver Mode에서의 지상관제 DATA 분석

  • Suk, Byong-Suk
    • Aerospace Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.65-71
    • /
    • 2002
  • KOMPSAT-1 AOCS mode divided into three major mode like Sun, Maneuver, Science Mode. The Maneuver mode consist of attitude hold and Δ-V Burn submode. This paper focus on the analysis of AOCS Maneuver Mode characteristics based on on-orbit playback data. The nadir pointing performance of attitude hold submode and the process for Δ-V Burn firing with plus/ minus 90 degree pitch/ roll maneuvering was verified. And also verified that the on-orbit performance meets the AOCS subsystem specification as designed.

  • PDF

Study of Absorbed Dose and Effective Dose for Prostate Cancer Image Guided Radiation Therapy using kV Cone Beam Computed Tomography (kV Cone Beam Computed Tomography (CBCT)를 이용한 전립선암 영상유도방사선치료 시 흡수선량 및 유효선량에 관한 고찰)

  • Na, Jong-Eok;Lee, Do-Geun;Kim, Jin-Soo;Baek, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.67-74
    • /
    • 2009
  • Purpose: To evaluate the results of absorbed and effective doses using two different modes, standard mode (A-mode) and low-dose mode (B-mode) settings for prostate cancer IGRT from CBCT. Materials and Methods: This experimental study was obtained using Clinac iX integrated with On Board Imager (OBI) System and CBCT. CT images were obtained using a GE Light Speed scanner. Absorbed dose to organs from ICRP recommendations and effective doses to body was performed using A-mode and B-mode CBCT. Measurements were performed using a Anderson rando phantom with TLD-100 (Thermoluminescent dosimeters). TLD-100 were widely used to estimate absorbed dose and effective dose from CBCT with TLD System 4000 HAWSHAW. TLD-100 were calibrated to know sensitivity values using photon beam. The measurements were repeated three times for prostate center. Then, Evaluations of effective dose and absorbed dose were performed among the A-mode and B-mode CBCT. Results: The prostate absorbed dose from A-mode and B mode CBCT were 5.5 cGy 1.1 cGy per scan. Respectively Effective doses to body from A mode and B-mode CBCT were 19.1 mSv, 4.4 mSv per scan. Effective dose from A-mode CBCT were approximately 4 times lower than B-mode CBCT. Conclusion: We have shown that it is possible to reduce the effective dose considerably by low dose mode(B-mode) or lower mAs CBCT settings for prostate cancer IGRT. Therefore, we should try to select B-mode or low condition setting to decrease extra patient dose during the IGRT for prostate cancer as possible.

  • PDF

Characteristics of Braid bars by Double Fourier Analysis (2중 퓨리에 해석에 의한 망상하천에서 사주의 특성 분석)

  • Jang, Chang-Lae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.529-533
    • /
    • 2012
  • 본 연구에서는 실내실험을 통하여, 하안침식을 고려한 망상하천에서 저수로의 이동특성을 조사하며, 2중 퓨리에 해석에 의하여 사주의 거동특성을 분석하였다. 실내실험은 평균입경이 1.4 mm이고, 표준편차가 1.35인 균일사로 10 cm 의 두께로 전체가 균등하게 채워진, 길이가 12 m, 넓이 2 m 수로에서 수행하였다. 각 시간별 하도의 지형변화에 대하여 2 중 Fourier 해석에 의한 지배적인 성분, 즉 모드(mode)의 변화를 분석하였다. 여기서 1-1 mode는 교호사주(alternate bars)이고, 1-2 mode와 2-2 mode는 2차 횡방향 모드로서 중앙 사주(central bars)를 나타낸다. 1-3 mode와 2-3 mode는 한 단면에서 횡방향으로 3개의 사주가 형성된 것(triple row bars)를 나타낸다. 초기에는 1-1 mode인 교호사주가 지배적이지만, 시간이 증가함에 따라, 교호사주인 1-1 mode는 감소하고, 한 단면에서 3개의 사주가 형성되는 2-3 mode가 지배적인 것으로 나타났다. 이러한 원인은 시간이 지나면서 사주가 발달하고, 하안침식이 되면서, 하폭이 증가하여 상대적으로 수심이 감소하면서 복렬사주가 발달하기 때문이며, Colombini 등(1987)이 이론적으로 예측한 결과와 잘 일치한다. 한 단면에서 3개의 모드가 나타나는 것은 하상에서 변화를 일으키는데 중요한 역할을 한다. 직선하도에서 사주의 수가 증가하는 것은 교호사주의 강한 비선형으로 상호작용하기 때문이다.

  • PDF

Instability of High-Speed Impinging Jets(II) (고속 충돌제트의 불안정 특성)

  • Gwon, Yeong-Pil;Im, Jeong-Bin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.4
    • /
    • pp.450-467
    • /
    • 1998
  • The characteristics of the unstable impinging circular jet is investigated based on the frequency characteristics and the sound field of the impinging-tones. Two symmetric modes S1 and S2, associated with low frequency and high frequency respectively, and one helical mode H have been observed. At low speed the S2 mode is dominant and switched by the S1 mode as the speed increases. When the jet speed is high the S1 mode is very active over the impinging distance from half the nozzle diameter to its ten times, while the S2 mode occurs at shorter distance corresponding to stage 2 and 3. The helical mode H seems unstable, likely to be influenced much by the experimental environment, and occurs at relatively high speed with almost the same frequency characteristics as the S2 mode. By estimating the convection speed of the unstable jet, it is found that the ratio of the convection speed to the jet speed decreases with both Strouhal number and Reynolds number and the speed of S2 mode is faster than the Si mode. When the present experimental results are compared with the previous investigations performed for the hole tone and the impinging tone with a small plate, the S1 mode is found to be associated with the ring vortex of large diameter with low speed, but the S2 mode with the vortex of small diameter with high speed. In addition, the frequency is found to be influenced by the nozzle configuration but the characteristics is almost the same. From the impinging distance and frequency range, it can be deduced that S1 mode is related with the jet column mode and S2 mode with the shear mode.

A 'Mode 3' Science Policy Framework for South Korea - Toward a Responsible Innovation System

  • Kim, Gouk Tae
    • STI Policy Review
    • /
    • v.8 no.2
    • /
    • pp.23-48
    • /
    • 2017
  • This article advocates for a Mode 3 science policy. Compared to the university research-based Mode 1 knowledge production system and the knowledge application-centric Mode 2 innovation system, Mode 3 can be defined as a system that integrates both Mode 1 and Mode 2-type knowledge production models. In this article, based on the major characteristics of the Mode 3 scientific knowledge production system, I agree with the advocates of Mode 3 that constructing a knowledge society requires an inclusive form of knowledge production and innovation system through the democratization of knowledge production as well as the promotion of social values. Moreover, the mechanisms for creating accountable innovation in the Mode 3 system should be given more attention from the science research and policy communities to make public policy for scientific and technological innovation more reflective of social changes. Similar to the ways that the Mode 1 and Mode 2 scientific knowledge production approaches have influenced the development of science policy models, the Mode 3 scientific knowledge production approach, or Mode 3 science, also has the potential to shape a new science policy model. I will refer to this as Mode 3 science policy. In an effort to conceptualize the democracy- and society-centric Mode 3 science policy model, I will articulate science policy strategies in four science policy domains in South Korea from the context of the Mode 3 science approach. These include (1) evaluation of publicly-funded research activities, (2) valorization of scientific knowledge (that is, enhancement of the value of scientific knowledge through governmental action), (3) development of a science policy decision-making support system, and (4) anticipatory foresight of science, technology and society. When adopting and implementing a Mode 3 science framework, one progressive change is to increase socially desirable innovation such as responsible innovation.

Mode Analysis of Cascaded Four-Conductor Lines Using Extended Mixed-Mode S-Parameters

  • Zhang, Nan;Nah, Wansoo
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2016
  • In this paper, based on the mode analysis of four-conductor lines, the extended mixed-mode chain-parameters and S-parameters of four-conductor lines are estimated using current division factors. The extended mixed-mode chain-parameters of cascaded four-conductor lines are then obtained with mode conversion. And, the extended mixed-mode S-parameters of cascaded four-conductor lines can be predicted from the transformation of the extended chain-parameters. Compared to the extended mixed-mode S-parameters of four-conductor lines, the cross-mode S-parameters are induced in the extended mixed-mode S-parameters of cascaded four-conductor lines, due to the imbalanced current division factors of cascaded two sections. The generated cross-mode S-parameters make the equivalent different- and common-mode conductors not independent from each other again. In addition, a new mode conversion, which applies the imbalanced current division factors, between the extended mixed-mode S-parameters and standard S-parameters is also proposed in this paper. Finally, the validity of the proposed extended mixed-mode S-parameters and mode conversion is confirmed by a comparison of the simulated and estimated results of shielded cable.

Comparison of Characteristics between $L_1-B_4$ mode and $L_1-B_8$ mode Ultrasonic Motors ($L_1-B_4$모드와 $L_1-B_8$모드 초음파 선형 전동기의 특성 비교)

  • U, Sang-Ho;Kim, Dong-Yeon;Kim, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1518-1520
    • /
    • 2002
  • Purpose of this research compares best transfer speed about applied frequency and voltage using characteristic of $L_1-B_4$ mode and $L_1-B_8$ mode linear ultrasonic motor that use piezoelectric effect. By method of study, analyzed best transfer speed measuring and comparison load status that use actuality telephone card in $L_1-B_4$ mode linear ultrasonic motor and no-load status of $L_1-B_8$ mode linear ultrasonic motor. Experiment result is applied frequency(58.4Hz) in $L_1-B_4$ mode linear ultrasonic motor (load state) and the best transfer speed by 19.8[cm/s] at applied voltage(56V) point. Also, $L_1-B_8$ mode linear ultrasonic motor (no-load state) is best transfer speed by applied frequency(27.9kHz) and 32.96[cm/s] at applied voltage (50V) point.

  • PDF

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF

Mark XIIA(Mode 5) IFF System Integration and Certification Test for Surface to Air Missile System (유도무기체계 모드 5 피아식별 체계통합 및 인증시험)

  • Kim, Woo-Hyun;Jung, Se-Young;Lee, Yun-Soo;Chang, Se-Myong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.160-168
    • /
    • 2022
  • The new IFF mode, Mode-5 replacing Mode-4, has already been established by the US DoD for its allies and NATO forces. A IFF retrofit program for replacing the Mark XII Mode-4 with Mark XIIA Mode-5 is in progress in order to overcome the security limitations of the former in R.O.K. IFF certification test for the new mode, Mode-5, has been performed on medium range surface to air missile platform of the Korean armed forces for the first time in R.O.K and this is regarded as a monumental event in Korean defense industry. The present paper is a discussion on the procedures applied to the IFF system retrofit and integration, lessons learned from AIMS test with the US AIMS PO as observer. The minimum modification from the existing Mark XII Mode-4 to Mark XIIA Mode-5 and evolutional adaption from previous design including interoperability are required for the system retrofit. Letter of Certification was received from the US AIMS PO after the tests. The authors propose that the lessons learned and know-how acquired during the tests are managed by the R.O.K Government as the standard structure of a database. It is expected that the use of the database will reduce the developmental difficulties and risk, also increase efficiency in future developments and other projects.