• Title/Summary/Keyword: 힘센서

Search Result 319, Processing Time 0.029 seconds

Design and Implementation of a Real-Time Product Defect Detection System based on Artificial Intelligence in the Press Process (프레스 공정에서 인공지능기반 실시간 제품 불량탐지 시스템 설계 및 구현)

  • Kim, Dong-Hyun;Lee, Jae-Min;Kim, Jong-Deok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.9
    • /
    • pp.1144-1151
    • /
    • 2021
  • The pressing process is a compression process in which a product is made by applying force to a heated or unheated material to transform it into the desired shape. Due to the characteristics of press equipment that produces products through continuous compression for a short time, product defects occur continuously, and systems for solving these problems are being developed using various technologies. This paper proposes a real-time defect detection system based on an artificial intelligence algorithm that detects defects. By attaching various sensors to the press device, the relationship between equipment status and defects is defined and collected based on a big data platform. By developing an artificial intelligence algorithm based on the collected data and implementing the developed algorithm using an embedded board, we will show the practicality of the system by applying it to the actual field.

Development of gripping force and durability test standard for myoelectric prosthetic hand (근전전동의수의 파지력 및 내구성 시험 표준 개발)

  • Gook Chan Cha;Suk-Min Lee;Ki-Won Choi;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.393-399
    • /
    • 2023
  • Upper limb amputees wear an upper limb prosthesis for both aesthetic purposes and functional necessity, and in particular, in the case of amputee with both hands, it is essential to wear a myoelectric prosthetic hand capable of gripping action. The prosthetic hand operated by the EMG signal of the remaining muscles is a public insurance benefit item of the Industrial Accident Compensation Insurance, and test method standards are needed to be developed for the safety of the user and the effectiveness of the product performance. In this study, we developed systems for measuring the gripping force of myoelectric hand prosthesis by a load cell and for durability test of the prosthesis over repeated use with a proximity sensor, and propose a test method standard. Since the international test method standard has not yet been established, it is expected that Korea will be able to play a leading role in this standardization field in the future.

Piezoelectric Properties of Lead-free $Ba(Ti_{0.8}Zr_{0.2})O_3-(Ba_{0.7}Ca_{0.3})TiO_3$ Ceramics for Haptic piezoelectric Actuator (햅틱 압전 액츄에이터용 $Ba(Ti_{0.8}Zr_{0.2})O_3-(Ba_{0.7}Ca_{0.3})TiO_3$ 무면 세라믹스의 압전특성)

  • Park, Min-Ho;Lee, Kab-Soo;Yoo, Ju-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.304-304
    • /
    • 2010
  • 최근 생활에 편리하며 휴대하기 좋은 전자기기들이 개발되고 있다. 휴대폰이나 MP3와 같은 전자기기들은 거의 필수품이라고 할 정도로 우리의 일상생활에 근접하여 있다. 그 종 대표적으로 휴대폰의 종류로 스마트폰과 같은 터치스크린을 이용한 사례는 점차 상승하고 있으며 시간이 지날수록 그 수요는 더욱 많아지고 있다. 때문에 몰입감 제공을 위하여 햅틱장치의 채용이 일반화 되고 있다. 햅틱장치란 가상환경이나 원거리에 있는 환경과 사용자가 상호 작용할 때 사용자에게 촉감이나 힘의 정보를 전달하여 주는 장치로 진동 및 회동 저항에 의해 사용자로 하여금 촉감들 느낄 수 있도록 하는 장치를 뜻한다. 즉, 현실감을 전달을 중점으로 하는 햅틱장치는 빠른 응답 속도와, 진동의 주파수와 크기는 독립적으로 제어가 가능해야 하며 기계적 수용기들을 직접적으로 자극할 수 있어야 한다. 하지만 모바일 햅틱장치의 경우 크기 및 소비전력의 문제로 모든 스펙을 만족하기에는 어려워 좀 더 한정적인 느낌을 제공할 수 없다. 현재까지 모바일 장치에서 햅틱 피드백을 위하여 진동모터나, 솔레노이드, 압전 액츄에이터 등이 많이 사용되어 지고 있다. 그 중 압전 액츄에이터는 입력에너지를 기계적 출력에너지로 변환되는 효과를 이용 한 것으로 압력 센서, 초음파 센서 등 많은 분야에서 응용되고 있으며 변위 범위는 작지만, 크기가 매우 작고 변위 정밀도가 높으며 발생력과 응답속도가 빠르다는 장점이 존재한다. 이를 이용한 햅틱 압전 엑츄에이터의 제작에 사용되는 압전 세라믹스는 높은 전기적 특성을 가질수록 더 졸은 효율을 가지며 이로 인하여 보다 좋은 전기적 특성을 가지는 압전 세라믹스를 필요로 한다. 현재 많이 사용되는 PZT계 세라믹스는 우수한 전기적 특성으로 많이 사용되고 있지만 Pb의 유독성으로 인한 환경문제로 Pb가 포함된 제품을 제한하고 있어 현재 Lead-free의 연구가 이루어지고 있다. Lead-free중 Ba$(Ti_{0.8}Zr_{0.2})O_3$(BZT)는 PZT계 세라믹스를 대체할 차세대 압전 재료로 주목받고 있다. 일반적으로 Lead-free의 압전계수($d_{33}$=100~300pC/N)는 비교적 낮은 값을 보이지만 BZT의 압전계수(BZT $d_{33}$~620pC/N)는 PZT계 세라믹스의 압전계수($d_{33}$=500~600pC/N)와 비교하여 부족하지 않은 압전계수를 보여주며 PZT를 대체할 재료로 주목받고 있다. 본 실험은 햅틱 압전 엑츄에이터용 무연 압전세라믹스의 제작을 위하여 Ba$(Ti_{0.8}Zr_{0.2})O_3-(Ba_{0.7}Ca_{0.3})-TiO_3$(BZT -BCT)의 조성으로 유전 및 압전 특성을 조사하였다.

  • PDF

Design and Analysis of Square Beam Type Piezo-electric Vibrating Gyroscope (압전세락믹을 이용한 사각보형 진동자이로의 설계, 제작 및 평가)

  • 이정훈;박규연;이종원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.282-286
    • /
    • 1995
  • 일반적으로 관성계 내의 물체에 대한 동적특성의 파악을 위해서는 속도, 가속도 및 각속도, 각가속도에 대한 정보를 필요로 하며 자이로는 이중에서 각속도를 측정하는 장치이다. 운동하는 질량에 회전각속도가 인가될 때 발생되는 코리올리힘을 측정하여 회전각속도를 검출하는 개념의 각속도 센서인 진동자이로는 성능이 회전형 자이로에 비해 떨어지나 구조가 간단하고 소형이며 대량생산이 가능한 장점이 있다. 진동자이로의 효시로는 1950년 영국의 Sperry Gyroscope Company의 "Gyroton"이며, 전자기력을 이용한 가진과 측정이 그 특징으로서 실험실 조건에서 지구의 자전속도를 측정할 수 있었다. 그후 1960년대에 General Electric에서 "VYRO"라는 모델을 개발했는데 압전소자를 이용하여 가진과 측정을 하는 방법이 사용되었다. 1980년대에 Watson Ind., Soderkvist등은 센서자체가 압전물질로 만들어진 자이로를 실험하였고 1990년도에 들어서는 진동자이로의 원리를 마이크로 머시닝 기술과 연계시켜서 소형 경량화와 대량생산을 목표로 연구가 일부 진행되고 있다. 현재 제품화되어 실제 응용되고 있는 예로는 무라다사의 삼각프리즘 형태의 자이로, 토킨사의 원통형 자이로 등이 있으며 이러한 자이로는 캠코더 화면의 안정화 장치에 주로 사용되고 있다. 본 논문에서는 압전소자의 압전, 전왜 방정식으로 출발하여 자이로헤드의 동적 거동을 해석하였다. 진동자이로는 물체의 공진주파수에서의 진동현상을 이용하며, 두 방향의 고유진동수를 일치시켜야 하는 등의 설계조건이 있다. 이러한 조건을 만족하도록 사각보 구조를 기본으로 하여 새로운 형태의 자이로헤드를 고안하였다. 자이로헤드의 구동회로를 설계, 해석하고 각속도를 측정할 수 있는 검출회로를 설계하여 설계된 진동자이로의 동적 특성을 확인하고 보정회로를 이용하여 사용 주파수 영역을 넓혔다.이용하여 사용 주파수 영역을 넓혔다.러한 강이성들이 보장되는 제어이론들 중 H$_{\infty}$ 제어이론이 많이 연구/응용 되고 있다. 특히 공칭 플랜트 모델과 함께 사용되는 플랜트 모델과 함께 사용되는 플랜트 불확실성 모델은 직접적으로 성능 및 안정도에 영향을 미치므로 주의 깊게 선정해야 한다. 방법의 실질적인 적용에는 어려움이 있다. 본 연구에서는 기존의 방법들의 단점을 극복할 수 있는 새로운 회귀적 모우드 변수 규명 방법을 개발하였다. 이는 Fassois와 Lee가 ARMAX모델의 계수를 효율적으로 추정하기 위하여 개발한 뱉치방법인 Suboptimum Maximum Likelihood 방법[5]를 기초로 하여 개발하였다. 개발된 방법의 장점은 응답 신호에 유색잡음이 존재하여도 모우드 변수들을 항상 정확하게 구할 수 있으며, 또한 알고리즘의 안정성이 보장된 것이다.. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field and the

  • PDF

Development of Elbow Wearable Robot for Elderly Workers (고령층 근로자들을 위한 팔꿈치 착용형 로봇의 개발)

  • Lee, Seok-Hoon;Lee, Si-Haeng;Kim, Jung-Yup
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.6
    • /
    • pp.617-624
    • /
    • 2015
  • This paper describes the development of a wearable robot to assist the elbow muscle for use by elderly workers in aging societies. Various previously developed wearable robots have drawbacks in terms of their price, portability, and slow recognition of the wearer's intention. In this paper, emphasis is placed on the following features to minimize these drawbacks. The first feature is that an actuator is attached only at the elbow joint that withstands the highest moment during arm motion to reduce the weight, volume, and price of the robot and increase its practicality. The second is that operation of the wearable robot is divided into two modes, a tracking mode and a muscle strengthening mode, and the robot can automatically switch between these modes by analyzing the wearer's intention through the brachial muscle strength measuring device developed in this study. The assistive performance of the developed wearable robot is experimentally verified by motion tracking experiments without an external load and muscle strengthening experiments with an external load. During the muscle strengthening experiments, the power of the muscle of the upper arm is measured by a commercial electromyography (EMG) sensor. Motion tracking performance at a speed of $120^{\circ}/s$ and muscle assistance of over 60 % were obtained using our robot.

Development and Reliability of Intraoral Appliance for Diagnosis and Control of Bruxism (이갈이 진단 및 조절용 구내장치의 개발과 신뢰도 조사)

  • Kim, Seung-Won;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.69-77
    • /
    • 2005
  • The purposes of this study were to develop and introduce a novel intraoral appliance for bruxism composed of power switch and biofeedback device and further to examine inter- and intra-reliability of the appliance prior to clinical tests. The newly-developed appliance consisted of detection sensors, a central processing unit (CPU), a reactor and a storage unit and a displayer. Compact-sized, waterproof switches were selected as bruxism detection sensor and any sensor activation by clenching or grinding event was processed at the CPU and transmitted, by radio wave, to the reactor and storage unit and triggered auditory or vibratory signal, subsequently producing biofeedback to the patient with bruxism. The data on bruxing event in the storage unit can be displayed on the computer, making it possible analyzing frequency, duration and nature of bruxism. Cast models were obtained from ten volunteers with normal occlusion to evaluate reliability of the appliances. For inter-operator reliability on the intraoral appliances, each operator of the two fabricated the appliance for the same subject and compared the minimal contact forces provoking auditory biofeedback reaction in vertical, lateral and central directions. Intra-operator reliability was also investigated on the appliances made by a single operator at two separate times with an interval of two days. Conclusively, the newly-developed appliance is compact and safe to use in oral circumstance and easy to make. Furthermore, it had to be proven reliability excellent enough to apply in clinical settings. Thus, it is assumed that this appliance with the processor and the storage of data and auditory or vibratory biofeedback function is available and useful to analyze and control bruxism.

A Study on The New Conceptual Faucet Design to Which Flow-meter is attached (유량 측정기기 부착 수전금구 디자인에 관한 연구)

  • 박성룡
    • Archives of design research
    • /
    • v.17 no.2
    • /
    • pp.351-362
    • /
    • 2004
  • Generally, they respond to a phenomenon, with their any way, which they have looked at in their surroundings, and also put into their action successively and variously according as what it is. A person who has not so much problems in experiential education added to mental and physical ability prefers controlling his manner by himself as seeing, listening and feeling to being cured it by other physical support. Meanwhile, even though there are tools that we use conveniently in everyday life, it is sometimes required that user is able to control his action by himself with a certain interactive function to deal with a accidental situation. For example, in the home, when they were cooking, washing dishes and taking a bath they would not often control their minds on how to act about flowing water through the faucet going back and forth between saving and easygoing. By reasons of those statements, the project has been studied to propose the new conceptual faucet which digital technology is applied to, for recognizing the volume of water flowed through water pipe as counting it with built-in flow meter, and then saving water as controling the water-flow with faucet lever. It means that homemakers can observe the flow rate of water from the faucet placed in front of the sink in kitchen and control it right away for saving water. For studying this project, the kinds and features of the various flow-meters that measure the volume of water-flow were researched and analyzed for taking a reasonable type to the new ideal faucet. According to this analyzing, turbine-flow-meter was selected as appropriate form for the digital display-built-in faucet that would be presented in this project. As the next step, the basic structure was created for developing a new conceptual faucet. Finally two models have been presented through several steps for making the suitable shape to the new style faucet.

  • PDF

A Study on User-Centric Force-Touch Measurement using Force-Touch Cover (포스 터치 커버를 이용한 사용자 중심적 포스 터치 측정에 관한 연구)

  • Nam, ChoonSung;Suh, Min-soo;Shin, DongRyeol
    • Journal of Internet Computing and Services
    • /
    • v.18 no.3
    • /
    • pp.37-48
    • /
    • 2017
  • Touch interface has been introduced as one of the most common input devices that are widely used in the Smart Device. Recently Force-Touch interface, a new approach of input method, having the power recognition mechanism, has been appeared in Smart industries. Force-Touching determining multiple things (the geographical and pressure values of touching point) in one touching act allows users to provide more than one input methods in a limited environments. Force-Touching Device is required different user communicational interaction than other common Smart devices because it is possible to recognize various inputs in the one act. It means that Force-Touching is only able to understand and to use the pressure sensitive values, not other Smart input methods. So, we built Force-Touch-Cover that makes typical Smart-Device to have Force-Touching interfaces. We analysis the accuracy of the Force-Touching-Cover's sensor and also assessment the changes in pressure values depending on the pressure position. Via this Paper, We propose the implement of user-oriented Force-Touching interface that is based on users' feedback as our conclusion.

A Preliminary Drop Test of a Type IP-2 Transport Package with a Bolted Lid Type (볼트체결방식의 IP-2형 운반용기의 낙하예비시험)

  • Kim Dong-Hak;Seo Ki-seog;Park Hong Yun;Lee Kyung Ho;Yoon Jeong-Hyoun;Lee Heung-Young
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11a
    • /
    • pp.339-347
    • /
    • 2005
  • A type IP-2 transport package should prevent a loss or dispersal of the radioactive contents and a more than $20\%$ increase in the maximum radiation level at any external surface of the package when it were subjected to the drop test under the normal conditions of transport. If a shielding thickness of IP-2 transport package is thick, a bolted lid type may prevent a loss or dispersal of the radioactive contents than the door type of ISO containers which are generally used as a type IP-2 transport package. In this paper, to evaluate the effect of drop directions on the bolt tension and the coherence of a bolt, the drop tests of preliminary small model are tested and evaluated for seven directions before the drop test of a type IP-2 transport package with a bolted lid type under the normal conditions of transport. Seven drop directions which are a bottom-vertical drop, a lid-vortical drop. a horizontal drop and four corner drops have been carried out. Using a force sensor, the bolt tension during the drop impact is measured. The coherence of bolt is evaluated by the difference between the fastening torque of bolt before a drop test and the unfastening torque of bolt after a drop impact.

  • PDF

Design of the control Algorithm for Improvement of the Convenience the Active-type Walking Aid (전동 보행보조기의 편의성 향상을 위한 제어기 설계)

  • Lee, D.K.;Kong, J.S.;Goh, M.S.;Kang, S.J.;Lee, S.M.;Lee, E.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.17-25
    • /
    • 2011
  • This paper aims to find the optimal control gain for enhancing the convenience of electric walking frames and design a control algorithm. With the recent advances in medical technology, there has been a rapid increase in the aging population and a variety of mobile walking frames have been developed for improvement of the quality of life. However, the manual walking frames of such mobile aids don't have any electric motor which helps facilitate elderly users' walking and thus are not efficient enough for the old people of weak strength to use especially when moving on uneven surfaces such as slopes or thresholds. The types of electric walking frames have been developed to overcome such inefficiency. Electric walking frames require users' control operations for motor driving unlike manual frames. Therefore, when they are not properly handled, it causes considerable inconvenience to their users. The present study compared the electric walking frames with manual ones in terms of operational convenience and attempted to improve the user convenience of walking frames varying the control value for user convenience based on certain standards. This paper presented a haptic sensor designed to recognize the will to walk and measure the degree of convenience and proposed a control algorithm for improvement of convenience. For user convenience, this paper evaluated the relative convenience of walking frames in view of changing differences between the center of vehicle (COV) and the center of position (COP). With the employment of an electric walking frame and a new measuring method, all the processes were experimentally tested and validated.