A study on convective cooling characteristics has been done in the channels with heat pipes and associated Plane fins Analysis with FLUENT V5.0 lies its Purpose on the possible enhancement of heat transfer capability between an existing three in-line arrayed heatpipes and an extending four in-line arrayed heatpipes with increasing channel width. Numerical analysis is limited to the laminar flow in an isolated flow channel by employing cyclic boundary conditions for calculation purposes. Friction factors for three and four in-line arrayed heatpipes are compared with experimental results. In addition, temperature behavior at the plate fin for the three in-line arrayed heatpipes is compared with experiment. Friction factors and overall channel heat transfer coefficients (and/or Nusselt numbers) are presented as a function of Reynolds number. An increase of number of heatpipes and channel width reults in a decrease of the friction factor and doesn't not result in an increase of heat transfer performance. However. considering the 25$\%$ increase of heat load accompanies with maximum 8$^{\circ}C$ rise of average temperature of heat pipes, the four in-line array with the increase of channel width of heat pipe heat sink can be considered appropriate.
After the Fukushima accident in 2011, it was revealed that nuclear power plant has the vulnerability to SBO accident and its extension situation without sufficient cooling of reactor core resulting core meltdown and radioactive material release even after reactor shutdown. Many safety systems had been developed like PAFS, hybrid SIT, and relocation of RPV and IRWST as a part of steps for the Fukushima accident, however, their applications have limitation in the situation that supply of feedwater into reactor is impossible due to high pressure inside reactor pressure vessel. The concept of hybrid heat pipe with control rod is introduced for breaking through the limitation. Hybrid heat pipe with control rod is the passive decay heat removal system in core, which has the abilities of reactor shutdown as control rod as well as decay heat removal as heat pipe. For evaluating the cooling performance hybrid heat pipe, a commercial CFD code, ANSYS-CFX was used. First, for validating CFD results, numerical results and experimental results with same geometry and fluid conditions were compared to a tube type heat pipe resulting in a resonable agreement between them. After that, wall temperature and thermal resistances of 2 design concepts of hybrid heat pipe were analyzed about various heat inputs. For unit length, hybrid heat pipe with a tube type of $B_4C$ pellet has a decreasing tendency of thermal resistance, on the other hand, hybrid heat pipe with an annular type $B_4C$ pellet has an increasing tendency as heat input increases.
Considering heat pipe design principles in fabrication and operational performances, water is one of the most recommended working fluids to make mid to low tempera lure heat pipes. But the conventional water heat pipes might encounter the failure in a cold start-up operation when socked at a chilling temperature lower than the freezing point. If they are subjected to a heat supply for start-up at a temperature around $-20^{\circ}C$, the rate of the vapor flow and the corresponding heat transfer from the evaporator to the condenser is so small that the vapor keeps to stick on the surface of the chilling condenser wall, forming an ice layer, resulting in a liquid deficiency in the evaporator. This kind of problems was resolved by Kang et al. in 2004 by adopting a gas loading heat pipe technology to the conventional water heat pipes. This study was conducted to examine a chilling start-up procedure of gas loading heat pipes by investigating the behaviors of heat pipe wall temperatures. And the thermal resistance of the gas loaded heat pipe that depends on the operating temperatures and heat loads was measured and examined. Two water heat pipes were designed and fabricated for the comparison of performances, one conventional and the other loaded with $N_2$ gas. They were put on start-up test at a heat supply of 30 W after having been socked at an initial temperature around $-20^{\circ}C$. It was observed that the gas loaded one had succeeded in chilling start-up operation.
전기 철도 차량의 A.C 모터 속도제어에는 여러 개의 GTO thyristor와 다이오드가 필요하다. 그런데 이러한 반도체 소자들은 약 1~2 kW의 열을 발생하기 때문에 냉각장치가 필요하며 이러한 반도체의 냉각에는 Perfluorocarbon(PFC)을 작동유체로 하는 히트파이프를 많이 사용하고 있다. 본 연구에서는 PFC 히트파이프의 증발 및 응축 열전달 계수에 미치는 관련변수로 주입율, 관의 내부 표면상태, 경사각, 증기압, 열유속 등의 영향을 파악하고, 열전달 계수를 예측할 수 있는 상관식을 제시하고자 하였다. 이를 위해 내부 표면에 그루브가 설치된 동관과 표면이 매끈한 외경 15.88mm인 동관을 이용하여 주입율이 다른 총 길이 520mm의 PFC 히트파이프와 열사이폰을 제작하고 실험을 수행하였다. 증발 열전달 계수는 열유속 15~45 kW/$m^2$의 범위일 때 2 kW/$m^2$K~5.5 kW/$m^2$K 사이의 분포를 보였다. 실험결과는 수정계수 CR=1.3을 적용할 때 Rohsenow의 핵비등 상관식과 실험치가 매우 접근된 결과를 보였으며 이러한 결과는 내부 벽면 그루브의 열전달 촉진효과이다. 응축 열전달 계수의 측정치는 1.5kW/$m^2$K~3.5kW/$m^2$K 사이의 분포를 보였으며 Nusselt 막응축 모델에 수정계수 CN=4를 도입함으로써 매우 접근된 예측이 가능하였다. 증발부 체적에 대한 작동유체 주입율은 40~100%의 범위가 적절하였다. 그리고 30$^{\circ}$이상의 경사각에서는 경사각의 영향이 미소하였다.
An experimental study was performed for understanding the limiting power and heat transfer characteristics of an MHP having the diameter of 3 or 4 mm which could be applied to cooling of miniature electronic equipment such as the notebook PC CPU etc. The experimental parameters which are inclination, structure of the wick, the length of the condenser and the total heat pipe were considered. The MHP with a woven-wired wick has the advantages of the improvement in capillary limit, the effective attachment tightly toward wall and the convenience in construction of wick. Cooling performance of the present MHP was compared with that of MHP with grooved, fine fiber and sintered type wick which were applied by existing enterprises. With respect to the inclination of$ -5^{\circ}$ , an MHP having the diameter of 3 or 4 mm shows the limiting power of 6~14 W. Therefore, it is expected that the MHP of the present study has sufficient applicability of cooling of notebook PC of which the amount of heat generated is about 12 W.
신재생에너지 분야 중 특히 태양에너지를 이용하는 분야는 자원의 무한 및 청정성 때문에 그 사용량이 증가 추세에 있다. 우리나라에서 태양열에너지의 이용률이 전체 에너지 사용량 중 아직 미미한 실정이지만, 근래 정부의 정책적 지원에 힘입어 이 분야에 대한 연구가 활발히 이루어지고 있다. 본 연구는 태양열집열기의 형상 변화에 따른 집열효율을 조사하기 위하여 단일진공관 태양열집열기를 이용한 실험 및 이중진공관 태양열집열기와의 비교 실험을 수행하였다. 그 결과, 본 실험장치에서 히트 파이프의 최고온도의 차이로부터 태양열집열기 형상 변화에 따른 집열효율의 변화를 확인할 수 있었다. 또한 본 연구대상 태양열집열기의 히트파이프의 온도가 비교대상 태양열집열기보다 높음에도 불구하고 방열핀의 온도가 낮게 관측되었다. 이것은 본 연구대상의 태양열집열기는 히트파이프 방열부인 헤드부와 방열핀 사이의 접촉저항이 비교대상의 접촉저항보다 크다는 것을 나타내며, 집열효율을 높이기 위해서는 태양열집열기의 여러 부분의 성능개선뿐만 아니라 접촉저항에 의한 집열손실도 감소시켜야 함을 확인할 수 있었다.
현대 주택이 고기밀 고단열로 건축되기 때문에 에너지 절감의 이점이 있는 반면 오염된 공기로 인한 많은 부작용이 발생하고 있다. 이런 부작용을 해결하기 위해 환기장치를 사용하여 실내 공기 환경을 개선하고 있다. 본 연구에서는 자동차용 에어컨의 열교환기로 사용되고 있는 평행류형 열교환기의 배기열 회수 환기장치로 적용 가능성을 알아보기 위해 냉매 충진량에 따른 열교환 효율 특성을 시험적으로 평가 하였다. 본 연구에서 사용된 히트 파이프는 환기장치에 적용이 가능하도록 분리형으로 제작되었다. 작동유체는 R22 냉매이고 유체의 충진량은 40~60(%vol.)로 10(%vol.) 단위로 충진 하였다. 환기량은 전면풍속을 기준으로 0.3~1.5m/s로 0.3 m/s 간격으로 바꿔 가며 측정하였다. 시험결과 최대 효율을 가지는 냉매 충진량이 환기량에 따라 다름을 알 수 있었고, 실험 결과 분석을 통하여 분리형 히트파이프의 환기량에 따른 최적 냉매 충진량을 찾을 수 있었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.