A Study on An Integrated GEO/TES with Geothermal Heat Exchanger and Thermal Ice Storage (지중열 교환기와 빙축열조(Thermal Ice Storage)를 연계시킨 통합 지중열-빙축열조 시스템(Integrated GEO/TES))

  • Lohrenz ED.;Hahn Jeongsang;Han Hyuk Sang;Hahn Chan;Kim Hyoung Soo
    • Economic and Environmental Geology
    • /
    • v.38 no.6 s.175
    • /
    • pp.717-729
    • /
    • 2005
  • Peak cooling load of large buildings is generally greater than their peak heating load. Internal and solar heat gains are used fur selection of adquate equipment in large building in cold winter climate like Canada and even Korea. The cost of geothermal heat exchanger to meet the cooling loads can increase the initial cost of ground source heat pump system to the extend less costly conventional system often chosen. Thermal ice storage system has been used for many years in Korea to reduce chiller capacity and shift Peak electrical time and demand. A distribution system designed to take advantage of heat extracted from the ice, and use of geothermal loop (geothermal heat exchanger) to heat as an alternate heat source and sink is well known to provide many benifits. The use of thermal energy storage (TES) reduces the heat pump capacity and peak cooling load needed in large building by as much as 40 to $60\%$ with less mechanical equipment and less space for mechanical room. Additionally TES can reduce the size and cost of the geothermal loop by 1/3 to 1/4 compared to ground coupled heat pump system that is designed to meet the peak heating and cooling load and also can eliminate difficuties of geothermal loop installation such as space requirements and thermal conditions of soil and rock at the urban area.

An Initial Study on the Reliability Assurance in PET/CT Standardized Uptake Values (PET/CT 에서 표준섭취계수(SUV)의 신뢰성 확보를 위한 초기연구)

  • Park, Hoon-Hee;Kim, Jung-Yul;Lee, Seung-Jae;Park, Min-Soo;NamKoong, Hyuk;Lim, Han-Sang;Oh, Ki-Baek;Kim, Jae-Sam;Lee, Chang-Ho;Jin, Gye-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.31-42
    • /
    • 2009
  • Purpose: As the number of domestic medical institutions installing PET/CT is increasing rapidly, the transfer of PET/CT images among medical institutions is also increasing. Thus, it is necessary to collect the comparative SUV data from several medical institutions' PET/CT systems through a phantom study which semi-quantitatively compares the SUV on one bed, the change scale of the SUV on the slices, and the time of measuring. The phantom study to find differences among the SUVs from various PET/CT offers the opportunity to obtain the reliability of the SUV in PET/CT images. Materials and Methods: Ten PET/CT systems from medical institutions in Korea were used. To obtain the accurate data, the study has been using the radiation detector of Korea Research Institute of Standards and Science to verify. The internal structures of NEMA $phantom^{TM}$ were removed and Six thousand milliliters of distilled water which has 1mCi of $^{18}F$-FDG put into the phantom. The water was properly integrated with $^{18}F$-FDG using magnetic stirrer. The images were acquired at 60, 70, 80, 90, 100, 110 and 120-minutes for 3 minute each. Two hundred square centimeters of region of interests were placed and analyzed. To confirm the usefulness, the correction-table came out from patients' data. Results: The coefficient of variability of the SUV from -11.0 to 9.90 % fell into the range of international standards(${\pm}10%$) along with the SUV on a bed, the change scale of the SUV on the slices, and the time of measuring, except one PET/CT system. Using the data of the differences among the SUVs, we came to withdraw the correction-table ranging from 0.803 to 1.246. The correction-table was confirmed its usefulness through Linear Regression Analysis which was applied to normal cases. Conclusions: Although studies have been made on the variation of the SUV, there is little attention on the standardization of the SUV. Based on this study of the quantitatively comparable data about the SUV accommodating the correction-table, it would help to have more corrective diagnosis.

  • PDF

Serial Survey on Group A beta-Hemolytic Streptococcal Carrier Rate and Serotyping in Elementary School Children in 1996~1998 (3년간(1996~1998) 초등학생의 A군 연쇄구균 보균율과 혈청학적 분류에 관한 연구)

  • Kim, Ji-Hyun;Kim, Ju-Ye;Kang, Hyeon-Ho;Cha, Sung-Ho;Lee, Young-Hee
    • Pediatric Infection and Vaccine
    • /
    • v.7 no.1
    • /
    • pp.143-151
    • /
    • 2000
  • Purpose : The accuracy of bacteriologic diagnosis of beta-hemolytic streptococcal pharyngotonsillitis depends on the degree of carrier rate in that area where the throat swabs are obtained and the evaluation of serological T typing as an epidemiologic marker is important to understand epidemiology of streptococcal infection. The purpose of this study is to know the carrier rates of group A streptococcus in normal children form four different areas and to find out the epidemiologic characteristic in distribution of the serotypes for 3 years. Method : Throat swabs were obtained from the tonsillar fossa of normal school children in four different areas(Uljin, Seoul, Osan, Kunsan) from March to May 1996, in Uljin in April 1997, and in Uljin in April 1998. The samples were plated on a 5% sheep blood agar plate and incubated overnight at $37^{\circ}C$ before examination for the presence of beta-hemolytic colonies. All isolated beta-hemolytic streptococcus were grouped and serotyped by T agglutination. Results : The carrier rate of beta-hemolytic streptococci and group A streptococci in 1996 were 27.6%, 18.6% at Uljin; 16.4%, 2.7% at Seoul; 33.0%, 26.0% at Osan; 20.0%, 12.3% at Kunsan, respectively. Among 1,192 normal school children from 4 different areas, we obtained 179 strains of group A streptococci. Fifty two percent of the strains were typable by T agglutination in 1996. Common T-type in 1996 were NT, T1, T3, T2 at Uljin; T12, T25 at Seoul; NT, T6, T28 at Osan; T25, T4, NT, T5 at Kunsan, in decreasing order, respectively. At Uljin, T1, T3, T25 accounted for 69% of strains in 1996, T1, T12, T25 accounted for 70% in 1997, and T12, T4 accounted for 88% in 1998. Conclusion : Higher carrier rates were found in Uljin and Osan, where there are a lower population density with scanty of medical facilities compared with another areas. We supposed that low carrier rates is likely to be related to antibiotic abuse or some epidemiologic factor. The periodic and seasonal serotyping analysis is important in monitoring and understanding the epidemiologic patterns of group A streptococci.

  • PDF

Toxin Profile in the Liver of Puffer Fish, Takifugu niphobles, and Changes in Mouse Toxicity by pH and Heating Conditions (복섬 간장의 독성분과 pH 및 가열 조건에 따른 독성의 변화)

  • Jang, Jun-Ho;Yun, So-Mi;Kim, Jung-Soo;Lee, Jong-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.5
    • /
    • pp.612-617
    • /
    • 2008
  • Tetrodotoxin (TTX) analogues were first determined from the liver extracts of puffer fish, Takifugu niphobles, by LC/MS with Hydrophilic Interaction Liquid Chromatography (HILIC). In total, 7 TTX analogues were detected within 20 minutes as follows; 5,6,11-trideoxyTTX (34.0%, 1,029.6 nmol/g), 6,11-dideoxyTTX (29.3%, 887.6 nmol/g), TTX (22.1%, 667.8 nmol/g), 4,9-anhydro-TTX (11.2%, 339.3 nmol/g), 11-deoxyTTX+5-deoxyTTX (2.6%, 78.6 nmol/g), and 4-epiTTX (0.8%, 23.6 nmol/g). Mouse toxicity of diluted liver extracts showed the highest toxicity at pH 3 (8.7 MU/mL) and decreased, as increasing pH, to 1.4 MU/mL at pH 10. At acidic (pH 5) and neutral conditions (pH 7), mouse toxicity of liver extracts (79 MU/mL) decreased slowly, as increasing temperature from $80^{\circ}C$ to $115^{\circ}C$, and time until 1 hour; in contrast, at the akaline condition (pH 9), the toxicity decreased rapidly to the more than half within 10 minutes. Individual toxicity of the fillet of T. niphobles were between $43.2{\sim}106.7$ MU, and $64{\sim}78%$ of its toxicity was eluted to soup when boiled with 3 volumes of water during 10 minutes.

Comparison study of dermal cell toxicity and zebrafish brain toxicity by humidifier sterilizer chemicals (PHMG, PGH, CMIT/MIT) (가습기 살균제 성분(PHMG, PGH, CMIT/MIT)의 사람 피부세포 독성 및 제브라피쉬 뇌신경 독성 비교 연구)

  • Cho, Kyung-Hyun;Kim, Jae-Ryong
    • Korean Journal of Environmental Biology
    • /
    • v.38 no.2
    • /
    • pp.271-277
    • /
    • 2020
  • Toxicities to many organs caused by humidifier disinfectants have been reported. Recently, humidifier disinfectants have been reported to cause cardiovascular, embryonic, and hepatic toxicities. This study was designed to investigate the toxic mechanism of humidifier disinfectants and compare toxicity in a cellular model and a zebrafish animal model. Because brain toxicity and skin toxicity have been less studied than other organs, we evaluated toxicity in a human dermal cell line and zebrafish under various concentrations of humidifier disinfectants that included polyhexamethyleneguanidine phosphate (PHMG), oligo-[2-(2-ethoxy)-ethoxyethyl-guanidinium-chloride] (PGH) and methylchloroisothiazolinone/methylisothiazolinone (CMIT/MIT). A human dermal fibroblast cell line was treated with disinfectants (0, 2, 4, 6, 8, and 16 mg L-1) to compare their cytotoxicity. The fewest PHMG-treated cells survived (up to 33%), while 49% and 40% of the PGH- and CMIT/MIT-treated cells, respectively, survived. The quantification of oxidized species in the media revealed that the PHMG-treated cells had the highest MDA content of around 28 nM, while the PGH- and CMIT/MIT-treated cells had 13 and 21 nM MDA, respectively. As for brain toxicity, treatment of the zebrafish tank water with CMIT/MIT (final 40 mg L-1) for 30 min resulted in a 17-fold higher production of reactive oxygen species (ROS) than in the control. Treatment with PGH or PHMG (final 40 mg L-1) resulted in 15- and 11-fold higher production, respectively. The humidifier disinfectants (PHMG, PGH, and CMIT/MIT) showed severe dermal cell toxicity and brain toxicity. These toxicities may be relevant factors in understanding why some children have language disorders, motor delays, and developmental delays from exposure to humidifier disinfectants.

Evaluation of Image Quality in Low Tube-Voltage Chest CT Scan (흉부 CT 검사 시 저 관전압 영상의 화질평가에 관한 연구)

  • Kim, Hyun-Ju;Cho, Jae-Hwan;Park, Cheol-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.4
    • /
    • pp.135-141
    • /
    • 2010
  • Purpose : The patients who visited this department for pulmonary disease and need CT scans for Follow-up to observe change of CT value, evaluation of image quality and decrease of radiation dose as change of kVp. Subjects and Methods : Subjects were the patients of 20 persons visited this department for pulmonary disease and Somatom Sensation 16(Semens, Enlarge, Germany) was used. Measurement of CT value as change of kVp was done by setting up ROI diameter of 1cm at the height of thyroid, aortic arch, right pulmonary artery in arterial phase image using 100 kVp, measuring 3 times, and recorded the average. CT value of phantom was measured by scanning phantoms which means contrast media diluted by normal saline by various ratio with tube voltage of 80 kVp, 100 kVp, 120 kVp, 140 kVp and recorded the average of 3 CT values of center of phantom image. In analysing radiation dose, CTDIVOL values of the latest arterial phase image of 120 kVp and as this research set that of 100 kVp were analyzed comparatively. 2 observers graded quality of chest images by 5 degrees (Unacceptable, Suboptimal, Adequate, Good, Excellent). Results : CT value of chest image increased at 100 kVp by 14.06%~27.26% in each ROI than 120 kVp. CT value of phantom increased as tube voltage lowered at various concentration of contrast media. CTDIVOL decreased at 100 kVp(5.00 mGy) by 36% than 120 kVp(7.80 mGy) in radiation dose analysis. here were 0 Unacceptable, 1 Suboptimal, 3 Adequate, 10 Good, 6 Excellent in totally 20 persons. Conclusion : Chest CT scanning with low kilo-voltage for patients who need CT scan repeatedly can bring images valuable for diagnose, and decrease radiation dose against patients.

The Molecular Weight Dependance of Paramagnetic Gd-chelates on T1 and T2 Relaxation Times (상자성 복합체의 분자량에 따른 T1 및 T2 자기이완시간에 관한 연구)

  • Kim In-Sung;Lee Young-Ju;Kim Ju-Hyun;Sujit Dutta;Kim Suk-Kyung;Kim Tae-Jeong;Kang Duk-Sik;Chang Yong-Min
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.61-66
    • /
    • 2006
  • To evaluate the T1, T2 magnetic relaxation properties of water molecule according to molecular weight of paramagnetic complex. 4-aminomethyicyclohexane carboxylic acid (0.63 g, 4 mmol) was mixed with the suspension solution of DMF (15 ml) and DTPA-bis-anhydride (0.71 g, 2 mmol) to synthesize the ligand. The ligand was then mixed with $Gd_2O_3$ (0.18 g, 0.5 mmol) to synthesize Gd-chelate. For the measurement of magnetic relaxivity of paramagnetic compounds, the compounds were diluted to 1 mM and then the relaxation times were measured at 1.57 (64 MHz). Inversion-recovery pulse sequence was employed for T1 relaxation measurement and CPMG (Carr-Purcell-Meiboon-Gill) pulse sequence was employed for T2 relaxation measurement. In case of inversion recovery sequence, total 35 images with different inversion time(T1)s ranging from 50 msec to 1,750 msec. To estimate the relaxation times, the signal intensity of each sample was measured using region of Interest (ROI) and then fitted by non-linear least square method to yield T1, T2 relaxation times and also R1 and R2. Compared to T1=($205.1{\pm}2.57$) msec and T2=($209.4{\pm}4.28$) msec of Omniscan (Gadodiamide), which is commercially available paramagnetic MR agent, T1 and T2 values of new paramagnetic complexes were reduced along with their molecular weight. That is, T1 value was ranged from $(96.35{\pm}2.04)\;to\;(79.38{\pm}1.55)$ msec and T2 value was ranged from $(91.02{\pm}2.08)\;to\;(76.66{\pm}1.84)$ msec. Among new paramagnetic complexes, there is a tendency that the R1 and R2 increase as the molecular weight is increases. As molecular weight of paramagnetic complex increases, T1 and T2 relaxation times reduce and thus the increase of relaxivity (R1 and R2) Is proportional to molecular weight.

  • PDF

Base-metal Mineralization in the Cretaceous Gyeongsang Basin and Its Genetic Implications, Korea: the Haman-Gunbug-Goseong(-Changwon) and the Euiseong Metallogenic Provinces (한국 경상분지 백악기 비철금속 광화작용과 그 성인적 의의: 함안-군북-고성(-창원) 및 의성 광상구를 중심으로)

  • 이상렬;최선규;소칠섭;유인창;위수민;허철호
    • Economic and Environmental Geology
    • /
    • v.36 no.4
    • /
    • pp.257-268
    • /
    • 2003
  • The Cretaceous magmatism in the Gyeongsang Basin, Korea, led to the formation of two contrasting metallogenic provinces: the Haman-Gunbug-Goseong(-Changwon) (HGGC) and the Euiseong (EU). The mineralization in the HGGC metallogenic province represents copper, gold and iron of porphyry-related deposits that display close relationships in time and space with subvolcanic granitoids. Much of copper-gold-forming events in this province are consistently constrained to the period between ca. 89 and 81 Ma. The hydrothermal systems of copper-gold vein deposits in the HGGC province are associated with ore-forming fluids of high to intermediate temperature (300∼50$0^{\circ}C$) with high salinity (20∼55 equiv. wt. % NaCl). The ore-forming fluids become progressively more diluted by the incorporation of decreased quantities of magmatic water further from the nearby intrusion, suggesting significant input and fluid mixing of a meteoric water component to the magmatic fluids during the late stage of geothermal systems. In contrast, the EU metallogenic province is characterized by polymetallic vein deposits that are consistently constrained to a period of 78∼60 Ma. The geothermal systems of polymetallic vein deposits in the EU province are derived from a narrow range of intermediate temperature (200∼40$0^{\circ}C$) with relatively low salinity(1∼7 equiv. wt.% NaCl). It may represent a mixed fluid of magmatic and meteoric waters. The base-metal mineralization in the Gyeongsang Basin shows a close spatial and temporal distinction between the proximal environment derived from shallow-level granitoids in the southwestern HGGC province and the distal condition derived from volcanic environments in the northwestern EU province.

The Efficiency of Bank Underwriting of Corporate Securities in Korea (국내 자본시장 증권인수기능의 효율성에 관한 연구 : 은행계열과 비은행계열 금융기관 비교 분석)

  • Baek, Jae-Seung;Lim, Chan-Woo
    • The Korean Journal of Financial Management
    • /
    • v.27 no.1
    • /
    • pp.181-208
    • /
    • 2010
  • In July 2007, Korean government has passed "The Capital Market and Financial Investment Services Act" to further develop the capital markets and the Act was to become effective in February 2009. Using a large sample of Korean firms, we have examined (i) the effect of underwriting activities on the firm value (bond spread) comparing commercial bank and investment bank, and (ii) the determinants of the firm value changes following underwriting activities of bank. To test our goal, we collected a wide range of samples of data for bond issuing activities executed by Korean firms listed on the Korea Stock Exchange (KSE) between 2000 and 2003. Our paper is distinguished from previous studies on this subject in a way that we analyzed the effect of corporate bond underwriting activities with regard to commercial banking and investment banking. Initially, we set up a hypothesis that "Certification View" and "Conflict-of-interest View" are major driving forces behind cross-firm differences in performance following bond issuance. We find that, in general, underwriting by investment bank (securities company) brings a positive effect on the firm value (spread between bench mark rate and bond issuing rate). This result indicates that firm value has been negatively affected by the bank underwriting and provides the evidence for "Conflict-of-interest View" in Korea. Our studies have also revealed that any change in firm value following bond issuance is positively related with the firm size (total asset), operating performance, liquidity (cashflow), and equity ownership by foreign investors. Overall, our results support the view that bank underwriting activities can play an important role in determining firm value and financial strategies under "The Capital Market and Financial Investment Services Act" of 2007.

  • PDF

Spent SCR Catalyst Leach Liquor Processed for Valuable Metals Extraction by Solvent Extraction Technique (SCR 폐촉매 침출액으로부터 용매추출법에 의한 유가금속의 추출)

  • Sola, Ana Belen Cueva;Jeon, Jong-Hyuk;Lee, Jin-Young;Parhi, Pankaj Kumar;Jyothi, Rajesh Kumar
    • Resources Recycling
    • /
    • v.29 no.2
    • /
    • pp.55-61
    • /
    • 2020
  • Selective catalytic reduction (SCR) has been a promising technology to reduce the air pollution caused by nitrogen oxides (NOx) in several industries. The consumption of SCR catalysts increases every year as technology evolves, however those have a limited lifespan and usually end up in landfills after they deactivate. Currently, the most widely used catalyst for and stationary applications is V2O5-WO3/TiO2 which can contain around 50% wt V2O5 and 7-10% wt of WO3. The vast uses for both vanadium and tungsten and the worldwide interest in recycling methods that allow for the extraction of metals from secondary sources represent the major motivation for this research. The extraction time, pH dependency, extraction concentration studies were carried out using Aliquat 336 in exxol D80 as the extractant. It was determined that to optimize the extraction of both metals 30min of contact time with an organic phase containing 0.5mol/L of Aliquat 336 are needed at a slightly acidic pH (~5.0). In addition, counter McCabe-Thiele studies allowed us to determine that one stage is necessary for the removal of 99% of vanadium while 2 stages are necessary for the extraction of tungsten and counter current simulations proved that the theoretical approach was correct.