• Title/Summary/Keyword: 흡착 여과

Search Result 201, Processing Time 0.031 seconds

Effect of GAC Packing Mass in Hybrid Water Treatment Process of PVdF Nanofibers Spiral Wound Microfiltration and Granular Activated Carbon (PVdF 나노섬유 나권형 정밀여과와 입상 활성탄의 혼성 수처리에서 활성탄 충진량의 영향)

  • Kyung, Kyu Myung;Park, Jin Yong
    • Membrane Journal
    • /
    • v.27 no.1
    • /
    • pp.68-76
    • /
    • 2017
  • Flat membrane with $0.4{\mu}m$ pore size was prepared with PVdF (polyvinylidene fluoride) nanofiber, which has the advantages such as excellent strength, chemical resistance, non-toxicity, and incombustibility. The spiral wound module was manufactured with the flat membrane and a woven paper. Hybrid water treatment process was composed of the PVdF nanofibers spiral wound microfiltration and granular activated carbon (GAC) adsorption column. Effect of GAC packing mass was investigated by comparing the case of recycling or discharging the treated water using the synthetic solution of kaolin and humic acid. After each filtration experiment, water back-washing was performed, and recovery rate and filtration resistances were calculated. Also, effect of GAC adsorption was compared by measuring turbidity and $UV_{254}$ absorbance. As a result, there was no effect of GAC packing mass on turbidity treatment rate; however, the treatment rate of $UV_{254}$ absorbance was 0.7~3.6% for recycling the treated water, and increased to 3.2-5.7% for discharging the treated water. In the case of recycling the treated water, reversible filtration resistance ($R_r$) and irreversible filtration resistance ($R_{ir}$) trended to decrease as increasing GAC packing mass; however, total fitration resistance ($R_t$) was almost constant, and recovery rate of water back-washing trended to increase a little.

Assessment of Micro Organic Pollutants Removal Using Advanced Water Treatment Process and Nanofiltration Process (고도처리공정과 나노여과공정에서의 미량유해물질 제거 평가)

  • Kang, Joon-Seok;Choi, Yang-Hun;Kwon, Soon-Buhm;Yu, Young-Beom
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.8
    • /
    • pp.579-587
    • /
    • 2014
  • Various kinds of micro organic pollutants have frequently been detected from a water system. Therefore, it is considered to be very important part in the drinking water treatment system. And the research about removal process and processing efficiency have been being conducted briskly. In this study, the removal efficiency was evaluated using advanced water treatment process and nanofiltration process. The removal efficiency of nanofiltration process was very different according to physical and chemical characteristics of materials. The molecular weight of cutoff was the most influential factor in the removal efficiency. And when pKa value was higher than pH of raw water or Log Kow value was below 2, the removal efficiency of material was decreased. In case of oxidation reaction, the bigger the molecular weight of material was and the more hydrophobic a material was, the less oxidation reaction occurred. And the removal efficiency was decreased. Most unoxidized materials were removed by absorption. And the more actively oxidation reaction occurred by $H_2O_2$, the more absorption reaction increased.

Removal of Ammonia in Water using Acid-impregnated Activated Carbon and Dynamic Membrane System (산 첨착활성탄과 동적막 공정을 이용한 수중 암모니아 제거)

  • Choi, Won Kyung;Shin, Dong-Ho;Lee, Yong Taek
    • Applied Chemistry for Engineering
    • /
    • v.17 no.3
    • /
    • pp.310-316
    • /
    • 2006
  • In this study, activated carbon in a powder form was used to remove dissolved ammonia which causes a fouling smell in water. Since the adsorption capacity of common powder activated carbon is not high enough, we prepared powder activated carbon deposited on an acid solution to enhance the adsorption capacity. The acid-impregnated activated carbon was applied on the surface of porous fibril support ($10{\sim}50{\mu}m$) by which adsorption and separation processes take place simultaneously by varying effective pressure. As the result, the ammonia removal efficiency is above 60% in the mixing process which is 10~15% higher than general powder activated carbon. From the result of an experiment on the pure permeable test of a dynamic membrane, its transmittance is 400~700 LMH (liter per hour), indicating that the prepared membrane works as a microfiltration membrane. Therefore, it is expected that the membrane prepared in this way would improve the efficiency of water treatment than conventional membranes.

Advanced Water Treatment of High Turbidity Source by Hybrid Process of Photocatalyst and Alumina Microfiltration: Effect of Organic Matters at Nitrogen Back-flushing (광촉매 및 알루미나 정밀여과 혼성공정에 의한 고탁도 원수의 고도정수처리: 질소 역세척시 유기물의 영향)

  • Park, Jin Yong;Sim, Sung Bo
    • Membrane Journal
    • /
    • v.22 no.6
    • /
    • pp.441-449
    • /
    • 2012
  • Effect of humic acid (HA) with periodic nitrogen back-flushing was investigated in hybrid process of alumina microfiltration and photocatalyst for drinking water treatment. It was compared and investigated with the previous results of microfiltration water back-flushing or ultrafiltration nitrogen back-flushing in viewpoints of membrane fouling resistance ($R_f$), permeate flux (J), and total permeate volume ($V_T$). As results, the trends of membrane fouling were different depending on nitrogen or water back-flushing, and depending on ultrafiltration or microfiltration made with the same material. Also, the nitrogen back-flushing using microfiltration was more effective membrane fouling inhibition than ultrafiltration, and the nitrogen back-flushing was more effective than water back-flushing using the same microfiltration membrane. Turbidity treatment efficiencies were almost constant independent of HA concentration, but HA treatment efficiency was the maximum at HA 10 mg/L. From this results, it was shown that the treated water HA quality increased as increasing HA concentration, but HA could be removed the most effectively by photocatalyst beads adsorption and photo-oxidation at HA 10 mg/L.

Effects of Filtration on the Characteristics of Reused Waste Brine in Kimchi Manufacturing (배추 절임 중 반복사용 폐염수의 여과처리 효과)

  • Yoon, Hye-Hyun;Kim, Dong-Man
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.444-448
    • /
    • 2002
  • The waste brine gained from successively reused brine during kimchi manufacturing can cause serious water pollution. We investigated the filtration effects on the physicochemical characteristics and microbial counts of the waste brine. Chinese cabbage was salted for five times successively, and the waste brines were filtered through sand and active carbon column. While original values of salinity and soluble solid contents of waste brine were 15.4% and $18.0^{\circ}$Brix$, respectively, we observed decrease of them to 0.1% and $0.0^{\circ}$Brix$, respectively, after filtration of the waste brine through sand followed by active carbon column. The filtration also recover pH value of the waste brine to its original value, which was decreased by successive salting from 8.3 to 6.0. We also observed that COD of waste brine increased to 63.2 ppm after five times of salting but decreased to 5.1 ppm after active carbon filtration. Total viable count was also increased with successive 5 steps of salting and was not detected after active carbon-filtration.

The adsorption efficiency of ceramic filter media prepared with the steel-making slag for the removal of VOCs (휘발성 유기화합물 제거를 위한 제강슬래그로 제조된 세라믹 여재의 흡착효율)

  • Sin, Jun-Ho;Kim, Tae-Heui;Park, Kyung-Bong
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.3
    • /
    • pp.153-157
    • /
    • 2010
  • We studied the adsorption efficiency of steelmaking slag in removing volatile organic compounds (VOCs) for increasing the recycling rate of steel-making slag. Ceramic filter was prepared by mixing the steel-making slag and the diatomite which is used as adsorbents due to the advantage of the high specific surface area and regular mesopores. The adsorption efficiency for VOCs removal was about 80%, 96% and 85% in acetaldehyde, formaldehyde and ammonia, respectively. The adsorption efficiency over 80% for all The gases showed the practical possibility as the adsorption filter.

The Ultrafiltration Characteristics of Oil/Water Emulsion Using Modified Polysulfone Membrane (표면처리 한 polysulfone 막으로 오일/물 에멀젼의 한외여과 특성)

  • Jeong, Gyeong-Hwan;Lee, Kune-Woo;Kim, Kil-Jeong;Jung, Ki-Jung;Kim, Chul
    • Journal of Energy Engineering
    • /
    • v.8 no.1
    • /
    • pp.119-126
    • /
    • 1999
  • 본 연구는 polysulfone 막을 표면처리 하여 오일 폐수를 한외여과 처리하였고 이때 fouling의 감소효과를 실험하였다. 고분자나 계면활성제를 polysulfone막에 흡착시켜 표면처리를 하였다. 다양하게 표면처리된 막으로 dodecane(0.1 v%)/물 에멀젼과 dodecane-계면활성제/물 에멀젼을 회분식 실험방법으로 수행하였다. SDS로 개질한 막으로 dodecane-계면활성제/물 에멀젼을 환외여과 처리하였을 때 fouling이 가장 작게 나타났고, 재사용에 좋은 방법으로 나타났다.

  • PDF

The Current of Ultrapure Water System (초순수 제조공정현황)

  • 이창소
    • Membrane Journal
    • /
    • v.6 no.3
    • /
    • pp.127-140
    • /
    • 1996
  • 국내의 초순수 제조장치는 90% 이상이 이온교환수지를 사용하는 이온교환법과 UF, R/O System과 같은 Membrane을 사용하는 Membrane System을 병행하여 적용하고 있다. 국내 초순수처리 Plant에서는 통상 전처리 System과 1차 순수제조 System및 초순수 System이 상호 연결되어 Plant가 구성 운영되고 있다. 전처리 System에는 응집침전, 여과 흡착, 살균 등이 적용되고 있으며 여과 System에 Membrane을 적용할 수 있으나 국내에서는 특별한 경우를 제외하고 대부분 전처리 여과 System에 Media Filter를 사용한다. 전처리 System도 순수처리 장치의 전처리로는 없어서는 안되는 System이지만 여기에는 전처리 System을 제외하고 국내에서 적용하고 있는 초순수처리 System의 공정현황과 각 System별 특징을 설명하였다. 초순수 System에는 요구 수질에 따라 다소 차이가 있지만 반도체 공업에서 사용되는 초순수 System이 이중 최고의 Grade로 반도체공업에서 적용되고 있는 System을 기준하였다. 특히 Membrane을 적용한 초순수제조 System이 증가하고 있어 R/O, ED, EDR, CDI(EDI)와 같은 Membrane System의 특성과 원리를 검토하였다.

  • PDF

In situ iron/manganese removal and permeability improvement at the river bank filtration site (강변여과수내 철망간 저감 및 투수성 개선)

  • Kim, Byung-Woo;Kim, Byung-Goon;Hur, Young-Teck;Kim, Dong-Sup;Kim, Hong-Suck
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.228-228
    • /
    • 2018
  • 강변여과는 지하수 인공함양 방식 중 유도함양(induced recharge) 또는 간접함양 방식에 속한다. 이는 하천 및 강변 부근에 집수시설을 설치한 후, 미고결층 대수층(unconsolidated aquifer)의 자연 오염 저감능을 이용하여 지표수를 간접 취수하는 방식으로 수질이 불량한 지표수가 대수층을 관류하면서 희석, 화학적 이온 교환 및 반응, 흡착, 생물막(biofilm; 미생물에 의한 자연저감), 여과 등을 통하여 수질이 개선된다. 강변여과수내의 용존 농도가 높은 철과 망간은 수처리 비용증가, 용수관정 및 시설물의 수명단축을 초래한다. 따라서 강변여과 지역의 미고결 대수층에서 효과적인 철과 망간 동시 제거(vyredox)를 위해 에어서징(air surging)과 블록 서징(block surging)을 실시하기 위해서 실내 물탱크 모델(water tank model)에서 에어서징에 따른 공기 순환 우물시스템을 관찰하였으며, 이를 바탕으로 현장시험(Test bed)에 적용하였다. 미고결 대층수층에서의 철 망간은 음용수 기준치(각각 0.3 mg/L)를 초과하고 있으며, 강변여과 취수 개발 및 이용을 제한하는 요인이 되고 있다. 본 연구에서 사용된 에어서징과 블록서지 기술은 자갈층 및 미고결 대수층에 충진된 슬라임 및 폐색(clogging)을 제거함과 동시에 관정 주변의 대수층의 투수성 개선과 산화환경으로 치환되며, 대수층에 잔존하는 철/망간의 산화물들을 관정내로 빼낼 수 있는 방법이다. 따라서 서징에 따른 폐색 제거효율을 검토한 결과에서 철 망간 이온농도 저감효과와 관정 주변의 수리전도도(hydraulic conductivity) 및 저류계수(coefficient of storage)가 증가한 것으로 나타났다. 이와 같이 강변여과에 의한 폐색은 미고결층내 공기주입 및 블록서지를 통하여 철/망간 이온농도 저감 및 수리특성 개선 효과에 유용한 것으로 평가된다.

  • PDF