• Title/Summary/Keyword: 흡입배관

Search Result 31, Processing Time 0.024 seconds

Three-One Check Valve 및 Suction Diffuser로 원가절감 효과를

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.22
    • /
    • pp.124-125
    • /
    • 1992
  • 토출배관에 Three-One Check Valve로 흡입배관에 Suction Diffuser로 시공하면 유체 차단기능, 역류방지 및 유량조절 기능 등을 겸하게 되므로 설치공간의 축소, 자재비$\cdot$인건비 절감효과를 얻을 수 있다.

  • PDF

A Study on the Free Surface Vortex in the Pipe System (배관내 자유수면에서 와류현상에 대한 연구)

  • Kim, Sang-Nyung;Jang, Wan-Ho
    • Nuclear Engineering and Technology
    • /
    • v.24 no.3
    • /
    • pp.311-318
    • /
    • 1992
  • During mid-loop operation of Nuclear Power Plant, to prevent the Decay Heat Removal System (DHRS) from failure due to air entrainment of free surface vortex in the piping system, a set of simulating experiments was performed. Through these experiments, a relation between the non-dimensionalized numbers, such as H/d, Froude number, Reynolds number, was found. It was also found that the perturbation of the system by the disturbance such as pump start, valve operation, etc., has a strong effect on the free surface vortex. Furthermore, from viewpoint of reactor safety, a modified inlet device which is reducer type is strongly recommended for the prevention of air entrainment into DHRS.

  • PDF

Experimental Study on the Blade Excitation Frequency for the Natural Frequence of Centrifugal Pump Piping Systems (원심펌프 배관계 진동에 영향을 주는 블레이드 가진주파수의 실험적 고찰)

  • 김윤제;신호길
    • Journal of Energy Engineering
    • /
    • v.10 no.4
    • /
    • pp.335-341
    • /
    • 2001
  • Pressure pulsations generated by the blade-tongue interaction induce vibration of the piping systems and the structure connected to pumps, resulting in the severe noise and fatigue fracture. Experiments were made on the natural frequencies of liquid columns in piping systems with a single suction, single stage, centrifugal volute pump. Experimental results show that the natural frequencies of the liquid columns in the pump piping systems depend on the dimensions of the pipes and the impeller shapes, and are not affected substantially by the rate of discharge and the rotating speed of the pump.

  • PDF

Fluid-Structure Interaction Analysis of Pressure Pulsation in a Suction Pipe of Compressor (압축기 흡입배관 압력 맥동의 유체-구조 연성 해석)

  • Oh, Han-eum;Jeong, Weui-Bong;Ahn, Se-Jin;Kim, Min-sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.779-780
    • /
    • 2014
  • This paper dealt with numerical estimation of pressure pulsation of the refrigerant in a suction pipe of the compressor. To evaluate the effect of reduction of pressure pulsation, a pipe system with tube was simulated using F.S.I.(Fluid-structure interaction) analysis. A commercial program was used for calculating behavior of pressure. The numerical simulation for pressure ratio of before and after going though internal structure were carried out. As a result, it was verified that the pressure after passing structure is less than the pressure before passing internal structure depending on the longitudinal frequency of structure.

  • PDF

Analysis and Experiment of Pressure Pulsation in a Suction Pipe of Compressor (압축기 흡입배관 압력 맥동 특성의 실험 및 해석)

  • Oh, Han-Eum;Jeong, Weui-Bong;Ahn, Se-Jin;Kim, Min-Sung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.10
    • /
    • pp.756-762
    • /
    • 2014
  • This paper dealt with numerical estimation of the pressure pulsation of the refrigerant in a suction pipe of the compressor. The behavior of the pressure pulsation was assumed to satisfy the wave equation. The boundary conditions and properties of refrigerant are necessary as input data of the simulation. The pulsating pressures at 15 points in a pipe were measured simultaneously from the pressure transducers. From the experimental data, the complex phase speed and impedance at the end of the pipe of the refrigerant were estimated using the signal processing and used as the input conditions of the numerical analysis. A commercial acoustic software was used to solve the behavior of pressure pulsation. The numerical results for the pressure pulsation in a pipe with and without expansion chamber were carried out and compared with those by experiments. Finally, numerical procedure to estimate the pressure pulsation in a pipe was established and verified.

RHRS에서의 공기흡입 방지에 관한 모의실험

  • 김상녕;장완호
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.277-283
    • /
    • 1996
  • 원자력 발전소의 일차계통 부분충수운전시 잔열제거 계통 입구에서 자유수면 와동으로 인해 계통에 공기가 흡입될 수 있으며 이로 인해 계통이 상실되거나 계기에 오차가 유발되어 많은 안전상의 문제를 야기할 수 있다. 이러한 문제들을 해결할 수 있도록 흡입구의 구조를 개선하기 위해 다양한 구조에 대해 실험을 수행한 결과 깔때기 모양과 우회유로를 설치한 경우. 그리고 기존 T자형에 와동 방지판을 부착하는 것이 매우 효과적임이 밝혀졌다. 하지만 깔때기 모양이나 우회유로의 경우는 배관구조의 변경이 필요하여 따라서 기존 발전소나 신설 발전소에 적용시 문제점이 많으므로 필요시 붙이고 불필요하면 제거가능한 탈착식인 다공 와동 방지판을 최종적으로 선정하였다. 이 경우에 대하여 1/4 축소 실험장치로 실험한 결과 운전유량 영역에서 와동의 발생으로 인한 공기흡입과 펌프의 정지를 획기적으로 줄여주는 것으로 밝혀졌다.

  • PDF

원자로 냉각재계통 RTD SCOOP내부 유속계산

  • 윤덕주;이창섭
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.42-47
    • /
    • 1996
  • 기존의 우회배관을 제거하고 원자로냉각재배관에 직접 RTD를 삽입하여 온도를 측정할 경우 취수부내의 유속이 기존에 비해 어떻게 변하는지 고찰하고자 한다. 이는 RTD응답시간 요건을 만족하기 위해서는 RTD SCOOP 내부유속이 3ft/sec이상이 되어야만 하기 때문에 중요하다. 이러한 유속을 계산하기 위해 취수부를 단순화하고 보수적인 가정에 의해 유체역학적으로 계산한 결과 이러한 요건을 만족하는 결과를 얻을 수 있었다. 또한 흡입구와 출구 Hole에서 차압의 대부분이 발생하므로 이부분의 부차계수가 유량계산에 절대적으로 영향을 미치고 있으며 아울러 원자로냉각재유량의 크기에 따라 미치는 영향을 계산한 결과 거의 비례적으로 증가하고 있으며 출구직경을 확대하므로 유량을 3.5 ft/sec까지 증가시킬 수 있다는 결과를 얻었다.

  • PDF

The study of CFD Modelling and numerical analysis for MSW in MBT system (생활폐기물 전처리시스템(MBT)의 동역학적 수치해석 및 모델링에 대한 연구)

  • Lee, Keon joo;Cho, Min tae;Na, Kyung Deok
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.3
    • /
    • pp.77-86
    • /
    • 2010
  • In this study, the model of the indirect wind suction waste sorting machine for characteristics of the screening of waste was studied using computational fluid dynamics and the drag coefficient for the model and the suction wind speed were obtained. The wind separator are developing by installing a cyclone air outlet to the suction blower impeller waste is selective in a way that does not pass the features and characteristics of the inlet pipe of the pressure loss and separation efficiency can have a significant impact on. Using Wind separator for selection of waste in the waste prior research on the aerodynamic properties are essential. For plastic cases, it is reasonable to take the drag coefficient between 0.8 and 1.0, and for cans, compression depending on whether the cans, the drag coefficient is in the range from 0.2 to 0.7. The separation efficiency of waste as change suction speed was the highest efficiency when the suction speed was 25~26 m/s. Shape of the inlet, depending on how the transfer pipe of the duct pressure loss occurs because the inlet velocity changes through the appropriate design standards to allow for continued research is needed.