• Title/Summary/Keyword: 흡수식 시스템

Search Result 177, Processing Time 0.026 seconds

Development of Membrane Disinfection Device for Recirculation of Drained Nutrient Solution (양액순환재배를 위한 박막여과식 양액재처리 장치 개발)

  • 이공인;지형진;김승희;김진영;최덕규
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.07a
    • /
    • pp.390-395
    • /
    • 2003
  • 우리나라의 수경재배 면적은 2001년말 현재 736㏊로 순환식이 296㏊, 비순환식이 440㏊를 차지하고 있다. 수경재배에서의 양액관리방법은 작물 및 재배시스템의 종류에 따라 다르지만 작물이 흡수하고 남은 양액이 양액탱크와 재배조사이를 왕복순환되는 순환방식과 양액탱크에서 재배조로 공급된 후 배출폐기되는 비순환방식(흘러버림식)으로 나누어진다. (중략)

  • PDF

Experimental Study on Compression/Absorption High-Temperature Hybrid Heat Pump with Natural Refrigerant Mixture (천연혼합냉매를 이용한 압축/흡수식 고온히트펌프의 실험적 연구)

  • Kim, Ji-Young;Park, Seong-Ryong;Baik, Young-Jin;Chang, Ki-Chang;Ra, Ho-Sang;Kim, Min-Sung;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1367-1373
    • /
    • 2011
  • This research concerns the development of a compression/absorption high-temperature hybrid heat pump that uses a natural refrigerant mixture. Heat pumps based on the compression/absorption cycle offer various advantages over conventional heat pumps based on the vapor compression cycle, such as large temperature glide, temperature lift, flexible operating range, and capacity control. In this study, a lab-scale prototype hybrid heat pump was constructed with a two-stage compressor, absorber, desorber, desuperheater, solution heat exchanger, solution pump, liquid/vapor separator, and rectifier as the main components. The hybrid heat pump system operated at 10-kW-class heating capacity producing hot water whose temperature was more than $90^{\circ}C$ when the heat source and sink temperatures were $50^{\circ}C$. Experiments with various $NH_3/H_2O$ mass fractions and compressor/pump circulation ratios were performed on the system. From the study, the system performance was optimized at a specific $NH_3$ concentration.

Performance analysis for the Characteristics of Double Stage Evaporator/Absorber for Large temperature Difference Absorption System (흡수식 대온도차 시스템에서 2단 증발/흡수기의 성능 특성에 관한 수치적 연구)

  • Park, Chan-Woo;Kang, Yong-Tae;Im, Ick-Tae;Moon, Sang-Done
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.304-308
    • /
    • 2008
  • The optimal design of two stage evaporation & absorption system which is related to the large temperature difference system was investigated numerically in the absorption refrigeration system. The concentrations at inlet & oulet of absorber are 62.9% and 56.9%, but in two stage absorption system the values are 62.2% and 56.2%. Therefore strong solution & weak solution became diluted than the standard value. The amount of weak solution circulation can be reduced in absorption refrigeration system, and the sensible heat load is more reduced to enhance the COP of system. As UAR is increased, COP becomes larger, and this means the role of top section is more important than bottom section in two stage evaporation & absorption system. But the increase of COP becomes slower at 0.7 of UAR ratio. The performance of Type2 is higher than Type1 in COP with the flow direction of cooling waters. This phenomena is due to the active absorption of vapor -absorption & lower temp. cooling water is more effective. The pressure at bottom section becomes higher & that at top section becomes lower and therefore the circulation rate can be diminished more.

  • PDF

Characteristics of Solid Regenerable $CO_2$ sorbents for Pre-combustion $CO_2$ Capture (연소전 $CO_2$ 포집용 분무건조 고체 흡수제의 물성 및 $CO_2$ 흡수 특성)

  • Baek, Jeom-In;Ryu, Jungho;Lee, Joong Beom;Eom, Tae-Hyoung;Kim, Ji-Woong;Jeon, Eon-Sik;Ryu, Chong Kul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.110.2-110.2
    • /
    • 2010
  • 현재 상용가능한 연소전 $CO_2$ 포집 기술은 습식 스크러빙 방식으로 고온의 합성가스를 상온 수준으로 온도를 낮춘 후 $CO_2$를 포집해야 하고 포집된 $CO_2$의 압력이 낮아 재압축하여 저장소로 보내야 함에 따라 큰 폭의 열효율 손실이 불가피하다. 고온 고압에서 이산화탄소를 포집할수 있는 고체 흡수제를 이용할 경우 이산화탄소 포집 치 저장 추가에 따른 시스템 효율 저하를 최소화할 수 있다. 고체 $CO_2$ 흡수제는 서로 연결된 두 개의 유동층 반응기를 순환하면서 흡수탑에서는 합성가스 중의 $CO_2$를 흡수하고 재생탑에서는 고온의 수증기와 접촉하여 흡수된 $CO_2$를 다시 배출함으로써 재생된다. 따라서 건식 재생 $CO_2$ 흡수제는 유동층 공정에 응용가능한 물성과 함께 높은 $CO_2$ 흡수능과 빠른 반응성이 요구된다. 본 연구에서는 유동층 공정에 적합한 물성을 가진 연소전 $CO_2$ 포집용 고체 흡수제를 분무건조법으로 제조하였으며, 모사 합성가스를 이용하여 열중량분석기와 기포유동층반응기를 이용하여 $200^{\circ}C$ 흡수, $400^{\circ}C$ 재생, 압력 20 bar 조건으로 반응성을 측정하였다. 개발된 고체 $CO_2$ 흡수제는 열중량분석기에서는 반응 후 10-13 wt%의 무게증가를 나타내었고 기포유동층반응기에서는 8-10 wt%의 $CO_2$ 흡수능을 보여주었다. 특히 수증기의 함량이 10% 이상에서 높은 흡수능을 나타내어 수증기가 반응에 크게 작용하고 있음을 알 수 있었다.

  • PDF

Analysis of the Operation Conditions and Energy Consumption for Each Energy Source (에너지원별 냉방기기 에너지 소비 및 운영현황 분석)

  • Kang, Yong-Tae;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.195-200
    • /
    • 2009
  • The objectives of this study are to analyze of energy consumption and operation conditions of each cooling system for gas and electric driven systems, and to compare operating cost for five different cooling systems; ice storage system, system air-condition, turbo chiller as the electric driven cooling systems, and absorption chiller and Gas driven Heat Pump (GHP) as the gas driven cooling systems. The sample designs are carried out based on the types of business, capacity, installation region and year.