• 제목/요약/키워드: 흡수사이클

검색결과 75건 처리시간 0.038초

저온 열원의 활용을 위한 흡수 발전/냉각 복합 사이클의 열적 해석 (Thermal Analysis of a Combined Absorption Cycle of Cogeneration of Power and Cooling for Use of Low Temperature Source)

  • 김경훈
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.413-420
    • /
    • 2011
  • Thermodynamic cycles using binary mixtures as working fluids offer a high potential for utilization of low-temperature heat sources. This paper presents a thermodynamic performance analysis of Goswami cycle which was recently suggested to produce power and cooling simultaneously and combines the Rankine cycle and absorption refrigeration cycle by using ammoniawater mixture as working fluid. Effects of the system parameters such as concentration of ammonia and turbine inlet pressure on the system are parametrically investigated. Results show that refrigeration capacity or thermal efficiency has an optimum value with respect to ammonia concentration as well as to turbine inlet pressure.

저온재생기2열원2중효용(低溫再生器2熱源2重效用) Parallel Flow Cycle의 특성(特性) 해석(解析) (Simulation of the performance characteristics of the double effect Parallel flow cycle with secondary heat at the low temperature qenerator)

  • 최국광;이동호
    • 태양에너지
    • /
    • 제17권3호
    • /
    • pp.43-49
    • /
    • 1997
  • 본 연구는 저온재생기에서 용액 재생 열원으로 저온열을 보조열원으로 이용가능한 2열원 2중효용 흡수 사이클특성을 규명하기 위한 방법으로 병렬 용액 순환형 2중 효용 흡수 사이클 해석을 수행한다. 본 해석은 저온 재생기에서 필요한 재생열의 일부를 태양열 또는 배열 등과 같은 저온 보조 가열원을 이용하여 열의 유용성 검증을 위한 기초 수단으로 가열원 입구 온도, 용액 순환량을 변화시켜 2중효용 parallel flow cycle 의 특성을 규명한다.

  • PDF

흡수식을 이용한 에너지 장거리 수송/변환 기술

  • 강용태
    • 대한설비공학회지:설비저널
    • /
    • 제33권3호
    • /
    • pp.11-18
    • /
    • 2004
  • 흡수식 사이클을 이용한 에너지의 장거리수송 기술을 소개하고 경제성평가 결과를 제시한다. 현재 에너지수요 측면에서 가장 높은 증가율을 보이고 있는 것이 바로 대도시 및 산업단지의 냉$.$난방 및 급탕용 에너지이다. 냉$.$난방에 사용되는 에너지는 10$0^{\circ}C$미만의 저온으로서 고열원 에너지인 화석연료의 사용은 에너지사용 면에서 비효율적이다. 따라서 산업지 역에서 버려지는 폐열원등의 각종 미활용에너지를 이용하여 냉$.$난방부하를 충족시킬 수 있는 에너지 절약형 시스템의 개발이 매우 중요한 과제로 대두되고 있다. 일반적으로 미활용에너지 및 폐열에너지 공급지역은 소비지역으로부터 멀리 떨어져 있다. 지금까지 흡수식시스템은 냉동 및 냉방의 개념에서 기술개발 및 실용적운전이 이루어져 왔으나, 본 논문에서는 흡수식시스템을 이용한 에너지의 장거리수송 및 변환 기술을 소개하고자 한다.

  • PDF

극저사이클 재하하에서 앵글 강부재의 파괴실험 (Tests on Failure of Steel Angles due to Very Low-Cycle Fatigue of Loading)

  • 박연수;김성칠;임정순
    • 대한토목학회논문집
    • /
    • 제12권4_1호
    • /
    • pp.23-32
    • /
    • 1992
  • 본 연구의 목적은 지진에 의한 강구조 부재의 소성피로손상 및 파괴에 크게 영향을 미치는 중요한 인자를 추출하여 그들간의 정량적 관계를 규명하는 것이다. 이를 위해, 앵글 강부재에 대하여 5~30 사이클 정도의 극저사이클 피로파괴실험을 실시하였다. 실험은 축방향 상대변위에 의해 제어된 반복 하중하에서 행하였으며, 앵글 시험체는 재하초기에 비탄성 전체좌굴 또는 국부좌굴이 발생하였다. 실험결과, 극저사이클 피로파괴하에서 강부재의 에너지 흡수능력은 재하이력과 파괴모우드에 따라 크게 변한다는 것을 알 수 있었고, 균열발생부에서 잔류 국소변형률의 최대치는 재하패턴 변형모우드 폭두께비에 관계없이 25~40% 정도였다.

  • PDF

吸氣冷却-蒸氣噴射 가스터빈 사이클에 관한 열역학적 연구 (A Thermodynamic Study on Suction Cooling-Steam Injected Gas Turbine Cycle)

  • 박종구;양옥룡
    • 대한기계학회논문집
    • /
    • 제16권1호
    • /
    • pp.77-86
    • /
    • 1992
  • 본 연구에서는 사이클은 터빈 출구로 부터 배출되는 폐열을 최대한 회수하여 얻은 증기를 연소기내에 분사시킴으로써 부가적인 압축기 및 비출력의 상향을 기할수 있다.아울러 폐열이용 암모니아 흡수기 냉동기를 구동하여 압축기 입구 온도를 낮 춤에 의해 열효율 및 비출력의 증대는 물론 대기온도 변화에 따른 기관 성능의 변동을 감소시킬 수 있다.

삼중효용 LiBr/물 흡수식 냉방기의 사이클 시뮬레이션 (Cycle simulation of a triple effect LiBr/water absorption chiller)

  • 조광운;정시영;정은수
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.79-87
    • /
    • 1998
  • Basic design of a 50USRT(175㎾) triple effect absorption chiller driven by hot gas has been carried out for both parallel and series flow cycles. Parallel flow cycle showed higher COP, however, the temperature in the generator was also higher than that in series flow cycle. Dynamic operation behavior of a parallel flow system at off-design conditions, such as the change in heat transfer medium temperature or the construction change of the system components, has been investigated in detail. It was found that the cooling capacity was seriously decreased by reducing hot gas flow rate and UA-value in the high temperature generator. However, the system COP was improved, because thermal load in the system components was reduced. The COP and the cooling capacity was found to be improved as cooling water temperature decreased or chilled water temperature increased. The optimum ratio of solution distribution could be suggested by considering the COP, the cooling capacity and the highest temperature in the system, which is critical for corrosion.

  • PDF

$H_{2}O/LiBr+HO{(CH_{2})}_{3}OH$를 이용한 2중 효용 흡수식 냉동기 특성해석 (Characteristic Analysis of Double Effect Absorption Refrigeration Machine using $H_{2}O/LiBr+HO{(CH_{2})}_{3}OH$)

  • 문춘근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.792-799
    • /
    • 1998
  • Further improvement of existing $H_{2}O/LiBr$ absorption refrigeration machine is absolutely neces-sary to promote the utilization of gas-cooling system Among various methods to improve the per-formance of the absorption refrigeration machine this research has focused on the use of a new working fluid that has better properties than the existing $H_{2}O/LiBr$ working fluid. In the series of the research, $H_{2}O/LiBr+HO{(CH_{2})}_{3}OH$ system was selected as the most promisable candidate. The absorption refrigeration machine is water-cooled double-effect, $H_{2}O/LiBr+HO{(CH_{2})}_{3}OH$ sys-tem with series flow type. In this study we found out the characteristic of new working solution through the cycle simulation and compared the result with that of LiBr solution to evaluate. Theoptimum designs and operating conditions were determined based on the operating constraints and the coefficient of performance. Results demonstrate that new working fluid subsrantially increases COP by as much as 10% and has a wider working range with 8% higher crystallization limits compared to the conventional $H_{2}O/LiBr$.

  • PDF