• Title/Summary/Keyword: 흡수법

Search Result 1,594, Processing Time 0.029 seconds

Metal Complexes of Ambidentate Ligand (VIII). Ni (II) and Pd (II) Complexes of Isonitrosomethylacetoacetate Imines (Ambidentate 리간드의 금속착물 (제 8 보). Isonitrosomethylacetoacetate Imine 리간드의 니켈(II) 및 팔라듐(II) 착물)

  • Bon-Chang Goo;Gang-Yeol Choi;Man-Ho Lee;In-Whan Kim
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.7
    • /
    • pp.662-671
    • /
    • 1993
  • New Ni(II) and Pd(II) complexes of isonitrosomethylacetoacetate imine derivatives, Ni(IMAA-NH)(IMAA-NH'), Ni(IMAA-NH)(IMAA-NR), $Pd(IMAA-NH)_2\;and Pd(IMAA-NR)_2(R=CH_3,\;C_2H_5,\;n-C_3H_7,\;n-C_4H_9,\;or\;CH_2C_6H_5)$, where H-IMAA-NH and H-IMAA-NR represent isonitrosomethylacetoacetate imine and N-alkylisonitrosomethylacetoacetate imine derivative, respectively, have been prepared and the structures of the complexes have been studied by elemental analyses, electronic, infrared, and $^1H-\;and\;^{13}C-NMR$ spectroscopies.

  • PDF

Preparation of poly-crystalline Si absorber layer by electron beam treatment of RF sputtered amorphous silicon thin films (스퍼터링된 비정질 실리콘의 전자빔 조사를 통한 태양전지용 흡수층 제조공정 연구)

  • Jeong, Chaehwan;Na, Hyeonsik;Nam, Daecheon;Choi, Yeonjo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.81-81
    • /
    • 2010
  • 유리기판위에 큰 결정입자를 갖는 실리콘 (폴리 실리콘) 박막을 제조하는 것은 가격저가화 및 대면적화 측면 같은 산업화의 높은 잠재성을 가지고 있기 때문에 그동안 많은 관심을 가지고 연구되어 오고 있다. 다양한 방법을 이용하여 다결정 실리콘 박막을 만들기 위해 노력해 오고 있으며, 태양전지에 응용하기 위하여 연속적이면서 10um이상의 큰 입자를 갖는 다결정 실리콘 씨앗층이 필요하며, 고속증착을 위해서는 (100)의 결정성장방향 등 다양한 조건이 제시될 수 있다. 다결정 실리콘 흡수층의 품질은 고품질의 다결정 실리콘 씨앗층에서 얻어질 수 있다. 이러한 다결정 실리콘의 에피막 성장을 위해서는 유리기판의 연화점이 저압 화학기상증착법 및 아크 플라즈마 등과 같은 고온기반의 공정 적용의 어려움이 있기 때문에 제약 사항으로 항상 문제가 제기되고 있다. 이러한 관점에서 볼때 유리기판위에 에피막을 성장시키는 방법으로 많지 않은 방법들이 사용될 수 있는데 전자 공명 화학기상증착법(ECR-CVD), 이온빔 증착법(IBAD), 레이저 결정화법(LC) 및 펄스 자석 스퍼터링법 등이 에피 실리콘 성장을 위해 제안되는 대표적인 방법으로 볼 수 있다. 이중에서 효율적인 관점에서 볼때 IBAD는 산업화측면에서 좀더 많은 이점을 가지고 있으나, 박막을 형성하는 과정에서 큰 에너지 및 이온크기의 빔 사이즈 등으로 인한 표면으로의 damages가 일어날 수 있어 쉽지 않는 방법이 될 수 있다. 여기에서는 이러한 damage를 획기적으로 줄이면서 저온에서 결정화 시킬 수 있는 cold annealing법을 소개하고자 한다. 이온빔에 비해서 전자빔의 에너지와 크기는 그리드 형태의 렌즈를 통해 전체면적에 조사하는 것을 쉽게 제어할 수 있으며 이러한 전자빔의 생성은 금속 필라멘트의 열전자가 아닌 Ar플라즈마에서 전자의 분리를 통해 발생된다. 유리기판위에 흡수층 제조연구를 위해 DC 및 RF 스퍼터링법을 이용한 비정질실리콘의 박막에 대하여 두께별에 따른 밴드갭, 캐리어농도 등의 변화에 대하여 조사한다. 최적의 조건에서 비정질 실리콘을 2um이하로 증착을 한 후, 전자빔 조사를 위해 1.4~3.2keV의 다양한 에너지세기 및 조사시간을 변수로 하여 실험진행을 한 후 단면의 이미지 및 결정화 정도에 대한 관찰을 위해 SEM과 TEM을 이용하고, 라만, XRD를 이용하여 결정화 정도를 조사한다. 또한 Hall효과 측정시스템을 이용하여 캐리어농도, 이동도 등을 각 변수별로 전기적 특성변화에 대하여 분석한다. 또한, 태양전지용 흡수층으로 응용을 위하여 dark전도도 및 photo전도도를 측정하여 광감도에 대한 결과가 포함된다.

  • PDF

Comparison of Several Methods for the Evaluation of Available Soil P in Upland Soils (전토양(田土壤)의 유효인산 분석방법(分析方法) 비교(比較))

  • Yoon, Jung-Hui;Shin, Cheol-Woo;Ryu, In-Sao;Hong, Chong-Woon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.10 no.4
    • /
    • pp.219-224
    • /
    • 1978
  • To compare various methods for available soil P test, in terms of correlation between crop yield and amounts of available soil P, a pot experiment was conducted with soybean as test plant using four upland soils differing in phosphorus status. The results are summarized as following. 1. There was highly significant correlation between grain yield and amount of P uptake observed at the floral differentiation stage. Highly significant correlations were also observed between grain yield and available soil P of different methods, and between the amount of P uptake and available soil P. The consistency of correlations between soil P and plant parameters was Olsen${\geq}$Lancaster P>Bray No.1 P${\geq}$Bray No.2 P>Truog P. 2. The magnitute of available soil P values of different methods was in the order of Bray No.2>Lancaster P${\geq}$Bray No.1 P>Olsen P>Truog P. 3. The amounts of available P measured by various methods showed significant correlation with the amounts of Al-P, Fe-P and Ca-P. 4. As conclusion, Olsen-P, Lancaster-P, and Bray-P are reliable information for evaluating soil P status. However, Olesen-P seemed to be better than the others.

  • PDF

Microwave Absorbing Properties of Silver-coated Ni-Zn Ferrite Spheres Prepared by Electroless Plating (무전해 도금법에 의해 제조된 은 피복 Ni-Zn Ferrite Sphere의 전파흡수특성)

  • Kim, Jong-Hyuk;Kim, Jae-Woong;Kim, Sung-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.3
    • /
    • pp.202-206
    • /
    • 2005
  • The present investigation provides an electromagnetic radiation absorptive composition which comprises silver-coated ferrite microspheres dispersed in silicon rubber matrix for the aim of thin microwave absorber in GHz frequencies. Ni-Zn ferrite spheres with $50{\mu}m$ size in average were prepared by spray-drying and sintering at $1130^{\circ}C$. Conductive silver layer was plated on ferrite spheres by electroless plating. Conductive Ni-Zn ferrite sphere with uniform silver layer were obtained in the concentration of 10 g/L $AgNO_3$ per 20 g ferrite spheres. For this powder, electrical resistance is reduced as low as $10^{-2}\~10^{-3}\;\Omega$. The most sensitive material parameters with silver plating is real and imaginary parts of complex permittivity. The conductive Ni-Zn ferrite spheres have large values of dielectric constant. Due to this high dielectric constant of microspheres, matching thickness is reduced to as low as 2 mm at the frequency of 7 GHz, which is much thinner than conventional ferrite absorbers.

Study on Optimization and Skin Permeation of PIT Nanoemulsion Containing α-Bisabolol (α-Bisabolol을 함유한 PIT Nanoemulsion의 최적화 및 피부흡수연구)

  • Kim, HuiJu;Yoon, Kyung-Sup
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.1738-1751
    • /
    • 2020
  • The skin is divided into three parts: the epidermis, the dermis, and the subcutaneous fat, and the stratum corneum, which is located at the top of the epidermis, acts as a barrier that prevents drug delivery. Nanoemulsions are known to be effective in transdermal delivery of drugs through intercellular lipids because of their unique small particle size. In this study, phase inversion temperature (PIT) nanoemulsion containing α-bisabolol was optimized using response surface methodology (RSM) for effective skin absorption of α-bisabolol. As a preliminary experiment, the 25-2 fractional factorial design method and the 23 full factorial design method were performed. Box-Behnken design was performed based on the results of the factorial design method. The content of surfactant (6.3~12.6%), co-surfactant (5.2~7.8%) and α-bisabolol (0.5~5.0%) were used as factors, and the dependent variable was the particle size of the nanoemulsion. PIT nanoemulsion optimization was performed according to the RSM results, and as a result, the optimal nanoemulsion formulation conditions were predicted to be 10.4% surfactant content, 6.3% co-surfactant content, and 5.0% α-bisabolol content. As a result of the skin absorption test, the final skin absorption rate of the PIT nanoemulsion was 35.11±1.01%, and the final skin absorption rate of the general emulsion as a control was 28.25±1.69%, confirming that the skin absorption rate of the PIT nanoemulsion was better.

Kinetic Studies of the Aggregation of 3,3'-Diethyl Oxacarbocyanine onto Polyacrylic Acid (폴리아크릴산 용액에서의 옥사카르보시안닌 색소분자의 회합현상에 대한 반응속도론적 연구)

  • Lee, Hong;Im, Eun Suk;Bae, Hyeon Ok
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.11
    • /
    • pp.792-799
    • /
    • 1994
  • The spectral changes of 3,3'-diethyl oxacarbocyanine(DOC) in the aqueous solution and in the presence of polyacrylic acid(PAA) were studied by means of absorption and fluorescence spectroscopy. The spectral change of DOC in the aqueous solution with concentration changes is attributed to the formation of dimer. In the presence of PAA, the characteristic changes of metachromatic band with changes of P/D (the ratio between available binding site and the dye concentration) are found and the discussions are made in terms of stacking theory. A kinetic study of the interaction between DOC and PAA was also investigated by the absorption and fluorescence stopped-flow spectroscopy. The observed relaxation effect in PAA-DOC system can be described quantitatively by assuming two relaxation processes occur.

  • PDF

Measurement of optical coefficients of multiple scattering media by using frequency domain spectroscopy (주파수 영역 분광법을 이용한 다중산란 매질의 광학계수 측정)

  • 전계진;윤길원;김건식;전성만;박승한
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.357-363
    • /
    • 1999
  • A frequency domain spectroscopic system was constructed to investigate the optical properties of multiple scattering media. The alternating current (AC) and phase lag components of backscattered light were measured by using the heterodyne detection method. Absorption and transport scattering coefficients were computed from the values based on diffusion theory. Predictions showed excellent matches in comparison with actual values of absorption and scattering. Predictable ranges of the optical coefficients were analyzed in terms of the distance between light source and detector, and modulation frequencies. A proposed compact experimental set-up using laser diodes can be utilized to estimate non-invasively the optical properties of multiple scattering media such as biological tissues.

  • PDF

Measurement of Absorption and Scattering Coefficients of Biological Tissues by Time-Resolved Reflectance Method (시간 분해 반사율에 의한 생체조직의 흡수계수와 산란계수 측정)

  • Jeon, Kye-Jin;Park, Seung-Han;Kim, Ung;Yoon, Gil-Won
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.499-505
    • /
    • 1997
  • A non-invasive technique to measure absorption and scattering coefficients was investigated The reflected backscattered light from the surface of phantom and biological tissue was obtained by using a time-correlated single photon counting system in pico-second time domain. The absorption and scattering coefficients were acquired by the time of peak and asymptotic behavior of the time-resolved reflectance curve and agreed well the ones that is obtained with deconvolution method It was found that the approximation method was good for biological medium to calculate optical properties due to its convenience and accuracy.

  • PDF

A Study on Improving the Capacity of Absorbing Boundary Using Dashpot (점성감쇠기를 이용하는 흡수경계의 성능 향상에 관한 연구)

  • Kim, Hee-Seok;Lee, Jong-Seh
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.629-640
    • /
    • 2007
  • In this paper an analytical study is carried out to improve the capacity of absorbing boundary using dashpot, one of the most widely used absorbing boundaries in FEM. Using 2-D harmonic plane wave equation, absorbing boundary condition is modified to maximize its capacity according to the incident angle. Validity of the absorbing boundary conditions which is modified is investigated by adopting the solution of Miller and Pursey. The Miller and Pursey's problem is then numerically simulated using the finite element method. The absorption ratios are calculated by comparing the displacements at the absorbing boundary to those at the free field without the absorbing boundary. The numerical study is carried out through comparison of displacement at the interior region and the boundary of the numerical model.

Bone Region Extraction by Dual Energy X-ray Absorbtion Image Decomposition (Dual Energy X-ray 흡수 영상의 분해를 통한 뼈 영역 추출)

  • Kwon, Ju-Won;Cho, Sun-Il;Ahn, Young-Bok;Ro, Yong-Man
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.9
    • /
    • pp.1233-1241
    • /
    • 2009
  • Over the 50 percents of women who are older than 45 years have osteoporosis. Because people hardly recognize this disease by themselves, the researches that measure bone mineral density have been doing widely to detect osteoporosis in the early stage. The most widely used methods for bone mineral density measurement are based on the X-ray imaging. Among them, DEXA(Dual-energy X-ray Absorptiometry) imaging is one of the important methods in bone mineral density measurement. DEXA images are useful methods to increase diagnosis efficiency by reducing anatomic noise as two images obtained from two different energy levels. However, it has some problems to a calibration parameter determined by the heuristic method for bone extraction. In this paper, we propose the method to extract bone in DEXA image using calibration parameter based on anatomic attenuation coefficient. The experimental results reveal that the proposed method is effective.

  • PDF