• Title/Summary/Keyword: 흡기

Search Result 571, Processing Time 0.027 seconds

The Effect of Wind-instrument Centered Music Therapy on Respiration, Oral Motor and Articulation for Patients with Cervical Cord Injury - Case Study - (취주악기를 사용한 음악치료가 경수손상환자의 호흡, 구강운동 및 조음에 미치는 영향 -사례연구-)

  • Kim, Tai youn;Park, Shin ae;Lee, Yong seok
    • 재활복지
    • /
    • v.21 no.1
    • /
    • pp.233-252
    • /
    • 2017
  • The purpose of this study is to investigate the influence on respiration, oral motor and articulation using wind-instrument centered music therapy for patients with cervical cord injury who need continuous train of respiratory muscle. Three patients with cervical cord injury who needed continuous training of respiratory muscle were selected and post data was analyzed. The harmonica using both exhalation and inspiration was selected as an wind-instrument. Each session was taken 30 ~ 40 minutes, once a week from total 6 weeks with small group. Material about every session's work was provided for individual to maintain practice after program. Oral motor and articulation test was done to assess reflecting features of maximal expiratory flow and wind-instrument of factor related breath. Maximal expiratory flow has increased by average 25ml more, articulation has increased by 3.16 points more and the movement of oral motor has increased 11.67 points more than pre-test from the analyzation. In the comparison of the details, the increase of oral motor function was confirmed from scores on the jaw and tongue except for the lips. Based on the results of this study, this study suggests that wind-instrument centered music therapy will be a practical and effective intervention for respiratory rehabilitation in patients with cervical cord injury.

A Study on the Supply Methods of Heating Energy in Rural Regions by Using Wood Chips -Focusing on the Production Method of Wood Chips for Fuel though Natural Drying Method- (목재칩을 이용한 농촌지역 난방에너지 공급 방법 연구 -자연건조 방식을 통한 연료용 목재칩 생산방법을 중심으로-)

  • An, Byeong-IL;Ko, Kyoung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.401-408
    • /
    • 2021
  • Supplies of wood chips for fuel tend to increase owing to energy decentralization and new renewable energy policies. This study suggests a technical method that is necessary in order to supply heating energy to rural regions by using wood chips for fuel. Therefore, this study investigates the effects of natural drying methods for eight months by installing a drying facility with natural ventilation capable of loading 10 tons of wood chips, and which derive a natural drying method based on this to meet the quality standards of wood chips for fuel. The study results confirm that it is possible to produce wood chips for high-quality fuel with water content at 20% or less after around 90 days of drying, provided that a drying facility with natural ventilation is equipped with materials that can be procured easily in rural regions. It is also possible to block the proliferation and fermentation of molds that affect the quality of wood chips, provided that intake and exhaust systems adhering to standards are equipped.

A Study for Failure Examples Including with Engine Oil Leakage, Poor Contact by Fin Damage and Vaporizer Inferiority on LPG Automotive (LPG 자동차의 엔진오일누설, 핀 손상에 의한 접촉불량, 베이퍼라이저 내부불량으로 인한 고장사례연구)

  • IL Kwon, Lee;Chang Ho, Kook;Sung Hoon, Ham;Seung Yong, Lee;Jae Gang, Lee;Seung Min, Han; Woo Chan, Hwang;Dae Cheon, Jang;Chang Bae, You;Jeong Ho, Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.24-29
    • /
    • 2022
  • This paper is a purpose to Analyze and study the failure examples for a engine oil leakage of camshaft bearing seal, poor contact by computer connector fin damage and vaporizer inferiority on LPG automotive. The first example, when the researcher disassembled the cylinder head of engine to establish the cause for oil leakage, he confirmed the engine oil leakage by damaged between the engine intake camshaft bearing and seal part. The second example, the connector fin of power source line that control the starting of a car supplied with engine computer. As a result, it found the fact that the engine operation stopped because of cutting of the power source by connector fin damage. The third example, it verified the engine incongruity phe cutting of the power source by connector fin damage. The third example, it verified the engine incongruity phenomenon as thd gas didn't flow the vaporizer by foreign substance deposit. Finally, it supplied a small quantity gas from vaporizer to mix. As the computer controlling mix opening condition supplied a air as opening signal, the air and fuel became rarefied state. it knew that the engine didn't produce prpper power. Therefore, a car have to throughtly inspect not in order to arise the failure symptoms.

The Development of Stuttering Therapy Device and Clinical Application Cases Using Breathing Control Prolonged Speech Method (호흡 조절식 연장기법을 이용한 말더듬치료 장치개발 및 적용사례 연구)

  • Rhee, Kun Min;Kwon, Sang Nam;Jung, Hyo Jae
    • 재활복지
    • /
    • v.15 no.2
    • /
    • pp.147-173
    • /
    • 2011
  • The purpose of this study was to develop a stuttering therapy device to aid in stutter therapy. The research method used for this study was as follows: First, the stuttering therapy device based on analysis of the prolonged speech method used at home and abroad was designed to achieve the goal of research. Second, the stuttering therapy device was to be developed to maintain a vocalization state, to use bio-feedback visualization, to have enough inspiration, to use Korean language in this device, and to use transfer and maintenance training in daily life. Third, the stuttering therapy device effectiveness was to be verified through use in clinical cases. The results of subjects receiving speech therapy and using the breathing control prolonged speech device and SI(stuttering Interview) evaluation programs for 3 months were as follows: For subject A, the stuttered word rate was reduced from 3.20 SW/M to 0.5 SW/M. For subject B, the stuttered word rate was reduced from 1.90 SW/M to 0.75 SW/M. For subject C, the stuttered word rate was reduced from 3.37 SW/M to 0.34 SW/M. For Subject D, the stuttered word rate was reduced from 0.51 SW/M to 0 SW/M. Follow-up evaluations verified the effectiveness of how the stuttering therapy device can reduce subjects' SW/M.

CHLOROFORM IN THE AIR OF INDOOR SWIMMING POOLS AND THE OUTDOOR AIR NEAR THE SWIMMING POOLS IN A CITY OF KOREA (국내 한 도시의 실내 수영장 공기 및 수영장 인근의 실외 공기에서의 클로로포름)

  • 조완근;황영미
    • Journal of Environmental Science International
    • /
    • v.3 no.3
    • /
    • pp.253-261
    • /
    • 1994
  • Chloroform present in the swimming water disinfected with sodium hypochlorite is released to the air of swimming pools. The air chloroform concentrations were measured in two swimming pools A and B which applied both sodium hypochlorite a:d ozone. Thew mean concentrations are 28.0 $\mu\textrm{g}$/m3 and 33.6 $\mu\textrm{g}$/m3in the swimming pools A and B, respectively. On the other hand, the mean water chloroform concentrations in the swimming pools A and B were 23.9 $\mu\textrm{g}$/l and 19.5 $\mu\textrm{g}$/l, respectively. The air chloroform concentrations were lower in the swimming Bools A and B than those reported by previous studies abroad employed the swimming pools which applied sodium hypochlorite only for water disinfection. The water chloroform concentrations were also lower in this study than in the previous studies. The relationship between the air and water chloroform concentrations measured in this study was significant with p=0.002 and Rz=0.42. At similar time to the indoor air sampling, outdoor air samples were collected at two sites near each of the swimming Pools A and B. The mean outdoor air chloroform concentrations near the swiminE Pools A and B were 0.41 $\mu\textrm{g}$/m3 and 0.16 $\mu\textrm{g}$/m3, respectively. The outdoor air chloroform concentrations measured in this study were equal to or lower than those reported by previous studies abroad. 'rho chloroform dose inhaled for a typical one-hour swim was estimated to be 25.9 $\mu\textrm{g}$ per person, corresponding to a specific 0.37 $\mu\textrm{g}$/kg body weight for a reference 70 Kg male adult, while the inhalation dose of chloroform from the outdoor air was estimated to be 5.6 $\mu\textrm{g}$ per person per day, corresponding to a specific 0.08 $\mu\textrm{g}$/Kg/day for the same reference male adult.

  • PDF

A Clinical Review of Primary Tracheal Carcinoma (원발성 악성기관종양의 임상적 고찰)

  • Ryu, Jeong-Seon;Cho, Hyun-Myung;Yang, Dong-Gyoo;Lee, Hong-Lyeol;Kim, Se-Kyu;Chang, Joon;Ahn, Chul-Min;Shin, Kye-Chul;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.766-775
    • /
    • 1997
  • Background : Primary malignant tumors of the trachea are extremely rare entities and account for a mere 0.1 per cent of all malignancies of the respiratory tract. Because of vague localizing signs, symptoms and a usually negative routine chest film, the patients with tracheal tumors are often treated for asthma or chronic obstructive pulmonary disease for considerable period of time before correct diagnosis. Method : We have made a review of the 17 cases of primary tracheal tumors in recent 15 years. We reviewed the clinical features including history of smoking and respiratory symptoms, the official readings of initial routine chest film, the cytologic examination of sputum, the time of delay in diagnosis, and the response according to the therapeutic modalities. Results : Eight out of 9 patients with squamous cell carcinoma(SCC) were above 50 years old, five out of 6 patients with adenoid cystic carcinoma(ACC) were below 50 years old. The most common location of primary tracheal tumors was the upper one-third of trachea in 8 cases(47%). The most frequent symptoms were dyspnea in 13/17 cases(76%) and then stridor or wheezing, cough. and sputum in order. The routine chest roentgenographic examinations were not helpful to diagnose tracheal carcinoma and the cytologic examinations of sputums were helpful to diagnose tracheal carcinoma in only one case with adenocarcinoma. The mean times of delay in diagnosis of patients with sec and ACC were 5 months and 24.9 months respectively. We had bronchial asthma in 8 cases(47%) and tracheal tumors in 4 cases(23%) as initial clinical impression. Conclusion : We would like to perform more comprehensive diagnostic tools(high KVP technique, the fibroptic bronchoscopic examination, chest CT scan etc.) in patients who had the suggestive points for the tracheal tumorse(1. unexplained hemoptysis or hoarsness, 2. inspiratory wheezing or stridor, 3. wax and waning of dyspnea according to changes of position, 4. progressive asthmatics unresponsive to antiasthmatic therapy) and radical resection of tumor or external radiation therapy with curative aim as possible.

  • PDF

Physiologic Changes During Bronchoscopy in Mechanically Ventilated Patients (기계환기중인 환자에서 기관지내시경 검사에 따른 생리적 변화)

  • Pyun, Yu Jang;Suh, Gee Young;Koh, Won-Jung;Yu, Chang-Min;Jeon, Kyeongman;Jeon, Ik Soo;Ham, Hyoung Suk;Kang, Eun Hae;Chung, Man Pyo;Kim, Hojoong;Kown, O Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.5
    • /
    • pp.523-531
    • /
    • 2004
  • Background : Bronchoscopy in patients on mechanical ventilation is being performed much more frequently. However, there is little data on the changes in physiologic parameters and no established mechanical ventilation protocol during bronchoscopy. A decreasing or the removal of positive end-expiratory pressure (PEEP) during bronchoscopy may precipitate severe hypoxemia and/or derecruitment. Methods : Our standardized mechanical ventilation protocol, without changing the PEEP level, was used during bronchoscopy. The physiological parameters were measured during the bronchoscopic procedure. Results : During bronchoscopy, respiratory acidosis, elevation of peak pressure, elevation of heart rate and auto-PEEP were developed, but were reversible changes. Procedure-related gross barotraumas or other severe complications did not developed. Conclusion : No serious complications developed during bronchoscopy under our standardized mechanical ventilation protocol when the PEEP level remained unchanged. The procedure time should be kept to a minimum to decrease the exposure time to undesirable physiological changes.

Clinical Characteristics of the Epidemic Mycoplasma pneumoniae Pneumonia Outbreak in 2003~2004 (2003년 하반기에 유행한 Mycoplasma pneumoniae 폐렴의 특징에 대한 고찰)

  • Kwon, Hye-Oak;Park, Shin-I;Lee, Jun-Ho
    • Pediatric Infection and Vaccine
    • /
    • v.12 no.2
    • /
    • pp.114-123
    • /
    • 2005
  • Purpose : A wide, epidemic outbreak of M. pneumoniae pneumonia occurred throughout Korea in late 2003. Compared with previous years, the 2003 outbreak resulted in more severe cases and in an increased incidence of extrapulmonary symptoms and/or complications. We compared the clinical characteristics for M. pneumoniae pneumonia of 2003 to those of the past years. Methods : One hundred six children diagnosed with M. pneumoniae pneumonia by serologic tests at Bundang Cha General Hospital between Aug 2003 to April 2004 were enrolled. Medical records were reviewed retrospectively, for clinical, laboratory and radiological aspect as well as complications. The pleural effusions of 3 patients who underwent thoracentesis were also analyzed. Results : The duration of fever, cough, rhinorrhea, and sore throat was $8.2{\pm}4.7$, $22.1{\pm}4.8$, $8.4{\pm}2.1$, $4.3{\pm}1.2$ days, respectively. The incidence (percentage) and duration of abdominal pain, vomiting, diarrhea, headache, skin rash, arthralgia was $5.1{\pm}2.5$ (21.9%), $3.4{\pm}2.1$ (17.1%), $4.3{\pm}1.8$ (16.2%), $3.5{\pm}2.1$ (14.4%), $5.5{\pm}0.7$ (5.9%) and $4.6{\pm}1.3$ days (4.9%), respectively. The mean duration of admission and treatment were $7.4{\pm}4.3$ days and $21.6{\pm}11.1$ days. Higher values of CRP and ESR on admission were positively correlated with the duration of fever and length of admission. The findings of pleural effusion were similar to those seen in TB pleurisy. Complications, including myocarditis (2 cases), arthritis (3 cases), vasculitis (5 cases), asthma (3 cases), ARDS (1 case), and DIC (2 cases) were observed in 14.1% of patients. Conclusion : We found a number of characteristics of M. pneumoniae pneumonia among cases from late 2003 that were different from those of previous years. This outbreak resulted in more severe cases and in an increased incidence of extrapulmonary symptoms and/or complications. A multicenter study is needed to verify the changes in clinical characteristics observed during the 2003 outbreak from previous ones.

  • PDF

Successful 20 hours Canine Allograft Preservation with new Solution Containing Triiodothyronine - Development of new lung preservation solution II - (삼요드티로닌을 포함한 폐보존액을 이용한 20시간 폐보존 - 새로운 폐 보존액의 개발 II -)

  • 성숙환;김영태;김주현
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.413-421
    • /
    • 1999
  • Background: Ischemia reperfusion injury is known to contribute to the major causes of the early graft failure in lung transplantation. Triiodothyronine (T3) has been suggested to ameliorate ischemia reperfusion injury from both in vivo and in vitro experiments of various organs. Prospecting its beneficial effect for pulmonary allograft preservation, we made a new solution by adding T3 into the extracellular type dextran solution. Material and Method: Twelve adult mongrel dogs underwent left lung allotransplantation. Six donor dogs were flushed with the new solution(Group 1, n=6), and the remaining six were flushed with Euro-Collins solution to serve as controls(Group 2, n=6). Allografts were stored in each preservation solution for 20 hours at 4$^{\circ}C$. Left single lung transplantations were performed. The right pulmonary artery and the right main bronchus were clamped at 15 minutes after the reperfusion and maintained throughout the experiment to evaluate the transplanted left lung function. Result: Arterial carbon dioxide tension was better in group 1 than in group 2 throughout the experiment period and the difference was statistically significant at 2 hours after reperfusion(28.0${\pm}$3.0 mmHg and 53.1${\pm}$17.4 mmHg, p<0.05). The differences of arterial oxygen partial pressure, peak airway pressure and pulmonary vascular resistance showed no statistical significance. The malondialdehyde(MDA) level, measured from tissue obtained at 120 minutes after reperfusion showed no statistically significant difference. The tissue wet/dry ratio of group 1(649${\pm}$27 %) was significantly lower than that of group 2(686${\pm}$71 %, p<0.05). The microscopic examination revealed varying degrees of injury represented mainly by findings such as perivascular neutrophil infiltration, capillary hemorrhage and interstitial congestion. These findings were less severe in group 1 than those in group 2. Conclusion: The new solution demonstrated superior allograft preservation after 20 hour ischemia compared to Euro-Collins solution in canine single left lung transplantation model, these results suggest that T3 might be a promising agent for pulmonary allograft preservation.

  • PDF

A Theoretical Model for the Analysis of Residual Motion Artifacts in 4D CT Scans (이론적 모델을 이용한 4DCT에서의 Motion Artifact 분석)

  • Kim, Tae-Ho;Yoon, Jai-Woong;Kang, Seong-Hee;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.145-153
    • /
    • 2012
  • In this study, we quantify the residual motion artifact in 4D-CT scan using the dynamic lung phantom which could simulate respiratory target motion and suggest a simple one-dimension theoretical model to explain and characterize the source of motion artifacts in 4DCT scanning. We set-up regular 1D sine motion and adjusted three level of amplitude (10, 20, 30 mm) with fixed period (4s). The 4DCT scans are acquired in helical mode and phase information provided by the belt type respiratory monitoring system. The images were sorted into ten phase bins ranging from 0% to 90%. The reconstructed images were subsequently imported into the Treatment Planning System (CorePLAN, SC&J) for target delineation using a fixed contour window and dimensions of the three targets are measured along the direction of motion. Target dimension of each phase image have same changing trend. The error is minimum at 50% phase in all case (10, 20, 30 mm) and we found that ${\Delta}S$ (target dimension change) of 10, 20 and 30 mm amplitude were 0 (0%), 0.1 (5%), 0.1 (5%) cm respectively compare to the static image of target diameter (2 cm). while the error is maximum at 30% and 80% phase ${\Delta}S$ of 10, 20 and 30 mm amplitude were 0.2 (10%), 0.7 (35%), 0.9 (45%) cm respectively. Based on these result, we try to analysis the residual motion artifact in 4D-CT scan using a simple one-dimension theoretical model and also we developed a simulation program. Our results explain the effect of residual motion on each phase target displacement and also shown that residual motion artifact was affected that the target velocity at each phase. In this study, we focus on provides a more intuitive understanding about the residual motion artifact and try to explain the relationship motion parameters of the scanner, treatment couch and tumor. In conclusion, our results could help to decide the appropriate reconstruction phase and CT parameters which reduce the residual motion artifact in 4DCT.