• Title/Summary/Keyword: 흉부 후.전 방향 검사

Search Result 12, Processing Time 0.023 seconds

Rate of Transformation and Normal Range about Cardiac Size and Cardiothoracic Ratio According to Patient Position and Age at Chest Radiography of Korean Adult Man (한국인 성인 남성의 흉부 방사선영상에서 자세와 연령에 따른 심장 크기 및 심흉비의 정상 범위와 변환율)

  • Joo, Young-Cheol;Lim, Cheong-Hwan;Kim, Yun-Min;Jung, Hong-Ryang;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.179-186
    • /
    • 2017
  • Purpose of this study is present the normal range of cardiac size and cardiothoracic ratio according to patient position(chest PA and AP) and age of Korean adult male on digital chest X - ray, And to propose a mutually compatible conversion rate. 1,024 males were eligible for this study, among 1,300 normal chest patients who underwent chest PA and low-dose CT examinations on the same day at the 'S' Hospital Health Examination Center in Seoul From January to December 2014. CS and CTR were measured by Danzer (1919). The mean difference between CS and CTR was statistically significant (p<0.01) in Chest PA (CS 135.48 mm, CTR 43.99%) and Chest AP image (CS 155.96 mm, CTR 51.75%). There was no statistically significant difference between left and right heart in chest PA and AP images (p>0.05). CS showed statistically significant difference between Chest PA (p>0. 05) and Chest AP (p<0.05). The thorax size and CTR were statistically significant (p<0.01) in both age and chest PA and AP. Result of this study, On Chest AP image CS was magnified 15%, CTR was magnified 17% compare with Chest PA image. CS and CTR were about 10% difference by changing posture at all ages.

A Study of Magnification of Cardiac Size and Cardiothoracic Ratio on Chest Posteroanterior Projection in Digital Radiography System (디지털방사선 환경에서 흉부 후.전방향 검사 시 심장과 심흉비 확대에 관한 연구)

  • Joo, Young-Cheol;Lim, Cheong-Hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.195-196
    • /
    • 2014
  • 현재 디지털방사선 환경으로 변화하고 있는 추세에 과거 필름-스크린 방식에서 사용되던 흉부 후 전 방향 검사 시 초점 영상 수신부 간의 거리가 디지털방식의 장비에도 여전히 적용되고 있다. 이에 본 연구에서는 3개의 DR장비에서 각 영상수용체의 제조특성을 고려하였을 때 실제 심장 및 심흉비의 확대정도에 대해 알아보고, 임상에서 DR 장비를 이용한 Chest PA 검사 시 심장 및 심흉비의 확대도에 대한 정보를 제공하고자 한다.

  • PDF

Analysis of the Influence of Examination Gowns on the Image and the Suitable Fabrics for Chest AP Examinations on DR X-ray Systems (디지털 X-선 시스템에서 흉부 전·후 방향 검사 시 검사복이 영상에 미치는 영향과 적정 검사복 원단의 분석)

  • Eun-Bi Baek;Yoo-Jin Jeong;Su-Bin Lim;Sang-Jo Park;Yeong-Cheol Heo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.865-872
    • /
    • 2023
  • The purpose of this study was to analyze fabrics suitable for use as examination gowns to determine whether examination gowns affect imaging during anterior to posterior chest examinations(Chest AP) on a digital X-ray system. Examination gowns in use at five medical centers in Seoul were collected and included modal, tencel, cotton, and rayon fabrics. The selection of fabrics was based on studies that reported fabrics with good tactile, absorbent, stretchable, and wrinkle resistance. Phantoms of five hospital gowns and four fabrics, arranged in overlapping layers from one to eight, were created and examined on a digital X-ray system in both Chest AP examination. The images examined were subjected to a first-step profile analysis, a second-step signal intensity averaging analysis, and a third-step microscopic analysis. The results showed that all nine materials had an increasing impact on the image as the number of layers of fabric increased, with the modal fabric having the least impact on the image in the first, second, and third analyses. In conclusion, as the resolution of digital x-ray systems increases, the impact of examination clothing on the image will increase, and research to find suitable materials for examination clothing will continue to be necessary.

The Study of Appropriate X-ray Tube Angle for the Anterior-posterior Chest Radiography Using S-align Function (S-align 기능을 이용한 흉부 전·후 방향 검사 시 적절한 X선관 각도에 관한 연구)

  • Park, Myeong-Ju;Joo, Young-Cheol;Kim, Min-Suk;Yuk, Jeong-Won;Kim, Han-Yong;Kim, Dong-Hwan
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.299-304
    • /
    • 2022
  • This study uses the 'S-align' function to present a reference value of the X-ray tube angle for the realization of an image similar to that of the chest PA image during chest AP radiography. This study targeted dummy phantom and used a 17"×17" DR image receptor. The irradiation conditions were 110 kVp, 160 mA, 50 ms, and the distance between the central X-ray and the image receptor was set to 180 cm and 110 cm, respectively. The end of the catheter was placed at the 11th thoracic height to indicate the nasogastric tube. In the case of lung apex length measurement, the mean value of measurement was 30.53±0.47 in PA. T 0°, TCA 5~25°, TCE 5~15° were 21.07±0.29, 27.60±0.21, 34.13±0.44, 39.86±0.31, 45.96±0.61 mm, 54.13±0.37 mm, 16.16±0.46 mm, 9.81±0.35 mm, 2.75±0.30 mm, respectively. For the depth of the catheter end, the average value measured at PA was 6.70±0.31 mm. T 0°, TCA 5~25°, TCE 5~15° were 15.72±0.38 mm, 24.10±0.50 mm, 29.24±0.86 mm, 34.35±0.35 mm, 41.06±1.08 mm, 48.07±0.38 mm, 12.85±0.25 mm, 7.92±0.36 mm, 3.01±0.39 mm, respectively. The length of the lung apex was similar to that of chest PA when the angle of incidence was adjusted from 5° to 10° in the leg direction, and the depth of the catheter tip was most similar when the X-ray tube angle was incident at 10° in the head direction. Therefore, To change the X-ray tube angle according to the purpose of the examination during the chest AP radiography using 'S-align' function is considered necessary.

A Comparative Study of Patient Dose and Image Quality according to the Presence or Absence of Grid During Chest PA Radiography using an Auto Exposure Control System (자동 노출 조절장치를 사용한 흉부 후·전 방향 방사선 검사 시 격자 유·무에 따른 환자 선량과 영상품질 비교 연구)

  • So-min Lee;Han-yong Kim;Dong-hwan Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.573-579
    • /
    • 2023
  • This study compares dose difference between the presence or absence of grid in Chest PA radiography using auto exposure control and compares image quality among presence, absence or virtual grid, and proposes a new clinically useful grid combination for chest radiography. The human body phantom was placed Chest PA position and the dosimeter was placed at T6. The same irradiation conditions and field size were applied. 30 images were obtained in the state in which grid was applied and in the state in which grid was not applied, and an additional 30 images in which the virtual grid was applied to the image without the grid were obtained. Radiation dose was presented to entrance surface dose. The image quality was analyzed by comparing the signal-to-noise and contrast-to-noise ratio. ESD decreased by 48% when the grid was not used, compared to when the grid was used. SNR and CNR increased by 32% and 30% compared to grid use when grid was not used, respectively. In the case of using the virtual grid, it increased by 18% and 16% respectively, compared to the case of using the grid. As a result of this study, it is believed that when using a virtual grid instead of a grid, the quality of the image can be maintained while reducing the patient dose.

Optimal Height of Shielding Plate of Radiation in Posteroanterior Chest Radiography for Pregnant Women on Korea (한국인 임산부의 흉부 후-전 방향 방사선검사 시 적절한 차폐막 높이)

  • Joo, Young-Cheol;Kim, Gyoo-Hyung
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.97-102
    • /
    • 2018
  • The purpose of this study is to provide the basic data for reducing unnecessary radiation dose to the abdomen and fetus of pregnant women by presenting proper height of shielding protector for efficient abdominal shielding in chest PA examination of Korean pregnant women. The subjects of this study were 288 persons who were eligible for this study among 798 pregnant women who had chest PA examination from January 1, 2015 to December 31, 2016 Retrospective study was performed. Measurements was performed from the apex of the right and left lungs to costophrenic angle of the right and left lungs and to the lowest costophrenic angle among the right and left lungs at the top of the image(this line called Joo's line in this study). The mean of the right and left lung height of pregnant women were 259.09 mm and 263.57 mm, respectively. Also, the average height of the Joo's line designed by the researcher for proper abdominal radiation protection was 322.15 mm. For proper and efficient abdominal radiation protection for pregnant women, it is necessary to adjust the shielding according to the height of the pregnant woman. It is appropriate that the height of the shielding protector should be adjusted so that the upper part of the shield is located at 342.30 mm below from upper part of the detector.

Radiological Measurements of Lung Field Size in Normal Korean using Digital Chest Posteroanterior Radiography (디지털 흉부 후·전 방향 방사선영상을 이용한 정상 한국인 폐 크기의 영상의학적 계측)

  • Park, Yeo-Jin;Joo, Young-Cheol;Lee, Il-Soo
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.1-6
    • /
    • 2018
  • The purpose of this study is to provide baseline data on lung field size measured radiological method by chest PA image in normal Korean. The subject of this study is 496 normal persons who performed chest PA examination using x-ray digital radiography system. The measurement method is from the apex of right and left lung to the costophrenic angle of both lung, from the top of the image to the lowest costophrenic angle of both lung and transverse line of the largest lung area. As a result of this study, the following conclusions were obtained. A lung field size of male is larger than the female(p<0.05). The younger the age, the longer both lung length and total lung height statistically significant. As a increase height and length, A lung field size was increased(p<0.05). But, BMI is not associated with a lung field size. This study will be data of reference data when radiological technologists perform chest PA examination.

Surgical Treatment of Ventricular Tachycardia After Total Correction of Tetralogy of Fallot- Report of a case (TOF 완전교정술후 발생한 심실빈맥의 외과적 절제술 -치험1례보고-)

  • 장병철;김정택
    • Journal of Chest Surgery
    • /
    • v.29 no.6
    • /
    • pp.639-645
    • /
    • 1996
  • A 14-year-old male patient with previous surgical repair of tetralogy of Fallot was admitted with hemodynamically significant ventricular tachycardia (VT). On preoperative electrophysiologic study (EPS), the morphology of documented VT was RBBB of vertical axis with 320 msec cycle length. The endocardial mapping during VT delineated the origin of VT at right ventricular outflow tract (RVOT), where the patch was attached. The clinical VT had a clockwise reentry circuit around the patch with the earliest activation at the same site seen during the preoperative EPS. The previously placed right ventricular outflow patch and fibrous tissue were removed. During a postoperative EPS, it was no longer possible to induce the VT. Ventricular tachycardia following repair of tetralogy of Fallot seen in this patient was caused by a macro-reentry around the right ventricular outflow patch. We were able to ablate the VT with the aid of a detailed mapping of its epicardial activation sequence.

  • PDF

Prognostic Factors Affecting Postoperative Morbidity and Mortality in Destroyed Lung (파괴폐의 술후 합병증과 사망에 영향을 미치는 예후 인자)

  • 홍기표;정경영;이진구;강경훈;강면식
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.387-391
    • /
    • 2002
  • Background: Postoperative morbidity and mortality in destroyed lung are relatively high. We tried to identify the prognostic factors affecting postoperative morbidity and mortality in destroyed lung through a retrospective study. Material and method: The retrospective study was undertaken in 112 patients who had undergone pneumonectomy or pleuropneumonectomy for destroyed lung at Severance Hospital from 1970 to 2000. We analyzed the correlation between postoperative morbidity and mortality and etiology, duration of disease, preoperative FEV1, presence or absence of peroperative empyema, operation timing, the side of operation, duration of operation, and operation type. Result: There were 55 men and 57 women, aged 20 to 81 years (mean 44 years). Etiologic diseases were tuberculosis in 86 patients(76.8%) including tuberculos empyema in 20 and tuberculous bronchiectasis in 4, pyogenic empyema in 12(10,7%), bronchiectasis in 12(10.7%), and lung abscess in 2(1.8%). Postoperative morbidity were 25%(n=28) and postoperative mortality was 6%(n=7). The presence of preoperative empyema(p=0.016), pleuropneumonectomy(p=0.037) and preoperative FEV1 of less than 1.75 L(P=0.048) significantly increased the postoperative morbidity, If operation time was less than 300min, postoperative morbidity(p=0.002) and mortality(p=0.03) were significantly low. Conclusion: Postoperative morbidity and mortality in destroyed lung were acceptable. Postoperative morbidity and mortality were significantly low when operation time was less than 300 min. Preoperative existence of empyema, pleuropneumonectomy and preoperative FEV1 of less than 1.75 L significantly increased postoperative morbidity.

Transthoracic Fine Needle Aspiration Biopsy in Localized Pulmonary Lesions: Diagnostic Accuracy and Complications (국소적 흉부 병변에서 세침 흡입 생검의 진단 성적 및 합병증)

  • Yang, Suck-Chul;Kim, Yeon-Soo;Kim, Soon-Kil;Kim, Tae-Wha;Lee, Kyung-Sang;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo;Lee, Jung-Hee;Jeon, Seok-Chol;Lee, Jung-Dal
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.685-694
    • /
    • 1995
  • Introduction: Transthoracic fine needle aspiration biopsy(TNAB) has shown to be a resonably safe, simple, and accurate procedure in diagnosis of intrathoracic lung lesions. We reviewed the results of 1,005 TNAB of chest lesions performed on 930 patients with 20 or 22-gauze needles over a period of 10 years. Methods: From November 1983 to June 1995, 1,005 cases in 930 patients with an undiagnosed lung lesion underwent TNAB at the Hanyang University Hospital: 66% were men and 34% were women. Most of the patients were 40~60 years old and the youngest patient was 3 years of age. Result: 540 patients had various malignant chest lesions and 322 patients had benign pulmonary lesions. The diagnostic accuracy of TNAB was 96.1 percent in malignant diseases with one false positive result and 90.1% in benign diseases. A definitive diagnosis was not obtained in the remaining 68 patients. The most common diagnoses among 519 malignancy chest lesions with TNAB were the following: squamous cell lung carcinoma, 31.7%; adenocarcinoma, 24.7%; small cell lung carcinoma, 16.7%; metastatic cancer, 14.2%; large cell lung carcinoma, 6.2% and so on. Complications included pneumothorax in 12.3% necessitating chest tube drainage in 0.6%. Minor hemoptysis occurred in 3.6%. There was no death directly attributable to the procedure. Conclusion: We concluded that TNAB permits a direct approach to all kinds of localized lung lesions with a high degree of accuracy and without major complications.

  • PDF