• Title/Summary/Keyword: 효과성 연구

Search Result 32,534, Processing Time 0.082 seconds

Mechanism and Spray Characteristics of a Mini-Sprinkler with Downward Spray for Prevention of Drop Water (하향 분사식 미니스프링클러의 낙수방지 메카니즘과 살수 특성)

  • Kim, Hong-Gyoo;Chung, Sung-Won
    • Journal of Bio-Environment Control
    • /
    • v.16 no.3
    • /
    • pp.210-216
    • /
    • 2007
  • A study was conducted to find mechanism and spray characteristics of a mini-sprinkler with downward spray to develop a new design type to be able to prevent drop water. The experiments were executed in a plastic greenhouse to minimize the effect of the wind. Data was collected at five different operation pressures and at 4 different raiser heights. Spray characteristics of the sprinkler such as effective radius, effective area, mean application depth, absolute maximum application depth, effective maximum application depth and coefficient of variation were determined. In order to analyze the mechanism and packing supporter of sprinkler, the numerical simulation using ABAQUS was performed. The optimum pressure for preventing drop water was determined.

Endocrine Function and Growth in Children with Craniopharyngioma (소아 두개인두종 환자에서 치료 전후의 뇌하수체 기능과 성장 및 체중 변화)

  • Chung, Yoo Mi;Shin, Choong Ho;Yang, Sei Won
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.3
    • /
    • pp.277-283
    • /
    • 2003
  • Purpose : Craniopharyngiomas are often accompanied by severe endocrine disorders. Although there is universal growth hormone deficiency(GHD), the resulting growth pattern is very heterogeneous. We report the growth and endocrine outcome of 44 children with craniopharyngioma, with emphasis on initial symptoms, growth before and during growth hormone(GH) treatment and spontaneous growth in spite of GHD. Methods : We performed a retrospective study of 44 children treated at our centre between 1984 and 2002. Results : About 30% of patients had symptoms suggesting endocrine disorder at diagnosis. After surgery, multiple endocrinopathies were almost universal. Before GH therapy, height velocity was $8.00{\pm}2.71cm/yr$ in the normal growth group(n=11) and $1.79{\pm}1.10cm/yr$ in the subnormal growth group(n=7) during the first year and during the second year, $6.76{\pm}2.49cm/yr$ and $2.29{\pm}1.33cm/yr$, respectively. There was no difference of body mass index(BMI) change between before and after surgery in the two groups. Height standard deviation score(SDS) was $-1.46{\pm}0.74$ in the normal growth group and $-0.43{\pm}0.97$ in the subnormal growth group. Before GH treatment height SDS was $-1.31{\pm}1.25$ and BMI was $20.46{\pm}3.60$. During GH treatment, height SDS increased to $-0.60{\pm}1.37$ in the first, and to $-0.41{\pm}1.54$ in the second year(P<0.05), but BMI did not change significantly. Conclusion : The endocrine morbidity could develop in most children with craniopharyngioma before and after the operation and should be managed properly. Although all treated patients benefit from GH therapy, further studies are necessary to find out the possible mechanism of growth regulation in normally growing children, despite GH deficient.

Complications of transcatheter closure of atrial septal defects using the amplatzer septal occluder (심방 중격 결손의 경피적 폐쇄술 후 발생한 합병증에 관한 연구)

  • Jea, Seo Jin;Kwon, Hyo Jin;Jang, Gi Young;Lee, Jae Young;Kim, Soo Jin;Son, Chang Sung;Lee, Joo Won
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.4
    • /
    • pp.401-408
    • /
    • 2008
  • Purpose : Transcatheter closure of atrial septal defects (ASD) is currently established therapy as an alternative to surgery. But rarely, complications are reported in some studies. We report early and intermediate term complications associated with transcatheter closure of atrial septal defects using the Amplatzer septal occluder (ASO). Methods : From June 2003 to May 2006, 64 patients underwent transcatheter closure of secundum ASD or patent foramen ovale using the ASO. The ratio of male to female was 1:2.4, the median age was 17 years (range: 2.6-64 years) and their median weight was 47.5 kg (range: 2.6-64 kg). Results : The median diameter of ASD measured with transthoracic or transesophageal echocardiography was 15 mm (range: 6-28 mm), the median balloon stretched diameter was 18 mm (range: 6.5-34 mm), and the median size of device was 19.5 mm (range: 6-36 mm), was little difference with balloon stretched diameter. There were 10 cases of complications: arrhythmia (2), device malformation (2), aorta to right atrial fistula (1), hemolytic anemia (1), mitral valve encroachment (1), malposition (1), residual shunt (1), and inferior vena cava perforation (1). Conclusion : Transcatheter closure of ASD using ASO is effective and safe therapy. However, significant complications such as aorta to atrial fistula, atrial erosion, or device embolization can happen, so an appropriate selection of patient and device in relevance to size and anatomy of ASD is important for successful closure.

Effect of Mulching with Easily-Decomposable Organic Materials on the Rice Growth and Earthworm Ecology Characteristics in Paddy Fields (분해성 피복자재의 멀칭처리가 벼 생육 및 지렁이 생태에 미치는 영향)

  • Nam, Hong-Shik;Lee, Sang-Beom;Park, Kwang-Lai;Hong, Seung-Gil;Kang, Chung-Kil;Son, Jin-Kwan;Kim, Seok-Cheol
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.4
    • /
    • pp.72-86
    • /
    • 2014
  • This study was conducted to investigate the effects of mulching of easily-decomposable organic materials including rice powder and corn starch on rice paddy fields. The treatments were including seven mulching materials each consisted of rice powder [Rice], starch with black color [Starch-B] and transparent [Starch-T] and stone powder [Stone], and conventional vinyl [Conventional], no-mulching without herbicide [Control-O] and no-mulching with herbicide [Control-C]. Rice growth and yield were different among the treatments; the highest yields were observed for [Rice] ($6.51ton\;ha^{-1}$) and [Conventional] ($6.47ton\;ha^{-1}$) followed by [Starch-T] ($6.25ton\;ha^{-1}$) and [Stone] ($6.20ton\;ha^{-1}$) which is comparable to the [Control-C] ($6.15ton\;ha^{-1}$). However, [Starch-B] showed lower rice yield ($4.93ton\;ha^{-1}$) than the [Conventional] or [Control-C]. Mean soil temperature ranged form 23.6 to $24.1^{\circ}C$ with the highest temperature for [Rice] treatment, and cumulative soil temperature was also significantly higher in the [Rice] treatment. Among the soil parameters, electrical conductivity, organic matter content, and phosphorus concentration were also different among the treatments. The amount of earthworm casting was higher for [Rice] treatment ($17.7kg\;m^{-2}$) compared to the others ($5.5{\sim}9.8kg\;m^{-2}$). It was suggested that mulching of rice fields with organic materials containing rice powder is better than others in respected to rice yield and earthworm activity.

Dosimetric Comparison of Left-sided Whole Breast Irradiation using a Virtual Bolus with VMAT and static IMRT (좌측 유방의 세기변조 방사선치료 시 Virtual Bolus 적용에 따른 선량 변화 비교 평가)

  • Lim, Kyeong Jin;Kim, Tae Woan;Jang, Yo Jong;Yang, Jin Ho;Lee, Seong Hyeon;Yeom, Du Seok;Kim, Seon Yeong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.51-63
    • /
    • 2019
  • Purpose: Radiation therapy for breast cancer should consider the change in breast shape due to breathing and swelling. In this study, we evaluate the benefit of using virtual bolus for IMRT of left breast cancer. Materials and methods: 10 patients with early breast cancer who received radiation therapy after breastconserving surgery compared the VMAT and IMRT plans using the virtual bolus method and without using it. The first analysis compared the V95%, HI, CI of treatment volume, Dmean, V5, V20, V30 of ipsilateral lung, and Dmean of heart in VMAT plan made using the virtual bolus method(VMAT_VB) to the plan without using it(VMAT_NoVB) in case there is no change in the breast. In IMRT, the same method was used. The second analysis compared TCP and NTCP based on each treatment plan in case there is 1cm expansion of treatment volume. Result: If there is no change in breast, V95% in VB Plan(VMAT_VB, IMRT_VB) and NoVB Plan(VMAT_NoVB, IMRT_NoVB) is all over 99% on each treatment plan. V95% in VMAT_NoVB and VMAT_VB is 99.80±0.17% and 99.75±0.12%, V95% in IMRT_NoVB and IMRT_VB is 99.67±0.26% and 99.51±0.15%. Difference of HI, CI is within 3%. OAR dose in VB plan is a little high than NoVB plan, and did not exceed guidelines. If there is 1cm change in breast, VMAT_NoVB and IMRT_NoVB are less effective for treatment. But VMAT_VB and IMRT_VB continue similar treatment effect compared in case no variation of breast. Conclusion: This study confirms the benefit of using a virtual bolus during VMAT and IMRT to compensate potential breast shape modification.

Dose Rate of Restroom in Facilities using Radioisotope (방사성동위원소 사용시설(내/외) 화장실의 외부선량률)

  • Cho, Yong-Gwi;An, Seong-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.237-246
    • /
    • 2016
  • This study is therefore aimed at measuring the surface dose rate and the spatial dose rate in and outside the radionuclide facility in order to ensure safety of the patients, radiation workers and family care-givers in their use of such equipment and to provide a basic framework for further research on radiation protection. The study was conducted at 4 restrooms in and outside the radionuclide facility of a general hospital in Incheon between May 1 and July 31, 2014. During the study period, the spatial contamination dose rate and the surface contamination dose rate before and after radiation use were measured at the 4 places-thyroid therapy room, PET center, gamma camera room, and outpatient department. According to the restroom use survey by hospitals, restrooms in the radionuclide facility were used not only by patients but also by family care-givers and some of radiation workers. The highest cumulative spatial radiation dose rate was 8.86 mSv/hr at camera room restroom, followed by 7.31 mSv/hr at radioactive iodine therapy room restroom, 2.29 mSv/hr at PET center restroom, and 0.26 mSv/hr at outpatient department restroom, respectively. The surface radiation dose rate measured before and after radiation use was the highest at toilets, which are in direct contact with patient's excretion, followed by the center and the entrance of restrooms. Unsealed radioactive sources used in nuclear medicine are relatively safe due to short half lives and low energy. A patient who received those radioactive sources, however, may become a mobile radioactive source and contaminate areas the patient contacts-camera room, sedation room, and restroom-through secretion and excretion. Therefore, patients administered radionuclides should be advised to drink sufficient amounts of water to efficiently minimize radiation exposure to others by reducing the biological half-life, and members of the public-family care-givers, pregnant women, and children-be as far away from the patients until the dose remains below the permitted dose limit.

Effect of Korean Ginseng on the Expression of Transferrin Receptor in the Liver Cell Membrane of Rat (백서의 간세포막에서 Transferrin Receptor의 발현에 미치는 인삼의 영향)

  • Lim Jong-Ho;Hong Jang-Hee;Hur Gang-Min;Seok Jeong-Ho;Lee Jae-Heun
    • Journal of Ginseng Research
    • /
    • v.23 no.2 s.54
    • /
    • pp.105-114
    • /
    • 1999
  • To investigate the effects of korean ginseng on the expression of transferrin receptor (TfR) in the liver cell membrane, we had carried out the experiments of $[^{3}H]thymidine$ uptake, $^{125}I-transferrin$ binding, and TfR mRNA expression in the liver after partial hepatectomy of normal and 3'-methyl-4-dimethylaminoa-zobenzene (3'-Me-DAB) treated rat with or without treatment of korean gingseng. $[^3H]thymidine$ uptake was not changed in the liver of 3'-Me-DAB or ginseng treated rat compared to that of control rat, but increased in that of partial hepatectomy of normal or 3'-Me-DAB treated rat. And this increased $[^{3}H]thymidine$ uptake was lowered slightly by the treatment of ginseng. Transferrin binding sites in the liver plasma membrane of ginseng treated rat with or without partial hepatectomy were similar, but increased in that of 3'-Me-DAB treated rat with or without partial hepatectomy compared to those of each control rat and these increased binding sites were reduced by ginseng treatment. Transferrin binding affinity (l/kd) was not changed by ginseng treatment, but tended to decrease in the liver of 3'-Me-DAB treated rat or in those after partial hepatectomy of all groups and reverse by ginseng treatment in 3'-Me-DAB treated rat. The expression of TfR mRNA was increased in the liver of 3'-Me-DAB treated rat with partial hepatectomy (peak at 24 hours), but lowered by ginseng treatment in this rat. From these results, it is suggested that korean ginseng has no effect on the increased expression of TfR with decreased affinity in the cell membrane of regenerated liver after partial hepatectomy of rat, but could inhibt that of 3'-Me-DAB treated rat through the regulation of DNA synthesis or TfR mRNA in partial.

  • PDF

Larch Pellets Fabricated with Coffee Waste and the Commercializing Potential of the Pellets (커피박과 낙엽송 목분을 이용한 펠릿 제조 및 이에 대한 상용화 검토)

  • Yang, In;Han, Gyu Seong;Oh, Seung Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.1
    • /
    • pp.48-59
    • /
    • 2018
  • This study was conducted to suggest the effective management and recycling processes of coffee waste, which can be easily obtained from coffee shops and coffee-related products industries. Prior to the fabrication of pellets, the potential of coffee waste as a raw material of pellet was investigated through the examination of its chemical compositions and fuel characteristics. Major gradient included in coffee waste was holocellulose, followed by fat/oil and protein. Coffee waste contained a small quantity of ash (0.7%), such as calcium, sodium, potassium and magnesium. Interestingly, coffee waste was easily dried probably due to its porous structure. Pellets fabricated with coffee waste and larch sawdust showed good fuel characteristics, such as moisture content, ash content, density and durability. The pellets exceed greatly the minimum requirements of $1^{st}$-grade wood pellet standard designated by National Institute of Forest Science (NIFOS). Particularly, the high calorific value of coffee waste showed the potential as a raw material of pellet. However, owing to high nitrogen and sulfur contents, coffee waste is like to be used as a raw material of wood pellet for combined heat and power plants equipped with a reduction system of $NO_x$ and $SO_x$ gases. On the other hand, 91 wt% larch sawdust and 9 wt% coffee waste are required to fabricate the $1^{st}$-grade wood pellets designated by NIFOS. Pellets fabricated with the conditions are estimated to have nitrogen content of 0.298% and sulfur content of 0.03%. Lastly, if amounts of coffee waste and sawdust in the production of wood pellets are adequately adjusted according to its purchasing price, the manufacturing cost of pellet can effectively be reduced. In addition, it is expected tp prepare the effective recycling process of waste and to relieve the environmental burden with the reduction of waste from the commercialization of coffee waste/larch pellets.

Treatment Outcome of Postoperative Radiotherapy in Extrahepatic Bile Duct Cancer (간외담관암의 수술 후 방사선치료 성적)

  • Choi, Young-Min;Cho, Heung-Lae
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.27-34
    • /
    • 2003
  • Purpose : To evaluate the efficacy of radiotherapy, and the factors affecting survival in patients of extrahepatic bile duct cancer, by analyzing the results of postoperative radiotherapy Materials and Methods : Between October 1991 and July 2001, 21 patients with extrahepatic bile duct cancer, who received radiotherapy after a radical resection, were retrospectively reviewed. The patients' ages ranged from 39 to 75 years, with a median of 61 years, and a male to female ratio of 16 to 5. The numbers of patients with proximal and distal bile duct cancer were 14 and 7, respectively. From the postoperative pathological examination, 19 of the patients were found to have microscopic residues, and 7 to be lymph node positive. Patients with AJCC stages I, II and III were 10, 10 and 1, respectively. The total radiation dose administered was 4,500$\~$6,300 cGy, with a median dose of 5,040 cGy. The follow up period was 20$\~$81 months, with a median of 57.5 months. Results : The overall and disease free survival rates at 3 and 5 years were 41.0 and 29.3$\%$, and 41.6 and 29.7$\%$, respectively. The influences of age, sex, tumor location, differentiation, microscopic residue, neural invasion, 7 and N stage, the stage itself, the dose of radiation and chemotherapy, on survival were evaluated. The T stage and the stage itself were found to be significant from a univariate analysis (p<0.05), but the degree of significance was limited by the small number of patients. A recurrence occurred in 12 patients (57.1$\%$), 5 in locoregional sites, 4 in distant sites and 3 in a combination of locoregional and distant sites, and the sites of distant metastasis were the liver, 6, and the bone, 1 Grade 2 or 3 acute leucopenias occurred in 2 patients and grade 2 chronic peptic ulcers occurred in 4, who were all recovered by conservative management. Conclusion : Postoperative radiotherapy is feasigbls in extrah데atic bile duct cancer, with tolerable toxicity, but prospective studies, with a large patient enrollment, are needed for the evaluation of the effects of postoperative radiotherapy and the related prognostic factors.

A Study of the Effect, Safety and Saving Expense by Reusing Hemodialyzer (재사용(再使用) 투석기(透析器)의 효과(效果) ${\cdot}$ 안정성(安定性) 및 비용절감(費用節減)에 관한 연구(硏究))

  • Jung, Ha-Chung
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.3 no.1
    • /
    • pp.93-106
    • /
    • 1997
  • By the increase of the rate of existence of the hemodialyzing patients, they were required the long run treatment. Regardless of medical insurance expansion, hemodialyzing cost much expenses so that hospital has been considering the reuse of hemodialyzer and flowing euqipments along with the diverse study and progress of the ways of hemodialyzing and medical instruments. This study was aimed to provide the basic materials regarding the reuse of hemodialyzer which is used for the patients of chronic renal disease. The reusing program in the artificial kidney center of K hospital has been used for this study from 50 patients aften one year result from Sep. 1995 through Aug. 1996. Automatic equipment of DRS-4 made by Seratronic Co., was used as the equipment and it was retreated with the function test simultaneously. Compliaction and confirmation of the infection were by the records of the hemodialysis of the patients. SPSS was used for the analysis of the materials by computerization. The character of the patients and the rate of removal was by mistake and percentage, function test and rate of complication by Ftest(ANOVA) and the rate of complication per items by ${\chi}^2$ and Ftest. As the post test the Duncan's test was used for the statistically significant different variables in the standard of p<.05 after Ftest. The followings are the summary of the result : 1) In the function test of the new hemodialyzer and the reused one, and in all of CA110 and CF15.11, the dialyzer ultrafiltration coeffient(KUf) was appeared to have been higher in the reusing groups than the first use ones. This has been the normal limit showing no troubles with them. 2) In the function test of the new and reused hemodialyzer, in all of CA110 and CF15.11, the total blood volume was appeared to have been the less value in the reuse groups than the new ones. This was the price within 80% of the first price that both showed possible for use. 3) The result of reuse hemodialyzer of CA110 was $29.48{\pm}7.83$ in average in the test of leak test while $17.3{\pm}7.96$ in reuse of CF15.11. The normal limit of <60 was the leak test result. So both of the hemodialyzer was normal for reuse. 4) The rate of removal of Blood Urea Nitrogen(BUN) was 72.25% in CA110 hemodialyzer by reusing 16-20 times as the highest rate showing the better result in the reuse hemodialyzer, while in CF15.11 hemodialyzer showed 71.16% by highest rate in the first use by the highest rate with no difference from the reuse. 5) The rate of removal of serum creatinine of CA110 was 64.08% by highest rate in reuse of 1-5 times by showing better result in reuse hemodialyzer. While in CF15.11 66.47% the highest by reuse of 16-20 times showing no difference from each other. 6) No patients were admitted or precribed by antibiotics in relation with reuse dialyzer and no reports were shown about hepatitis $B{\cdot}C$. AIDS in fection. 7) Of the total 248 episods of complication due to the hemodialyzing, 86 by first use, 73 by 1-5 times, 35 by 6-10 times, 35 by 11-15 times and 19 by 16-20 times have been shown which have had no significant difference between the groups. 8) In the comparison of the expense for the hemodialyzer, there was the effect of saving 11,597.6 Won between the first and reuse hemodialyzer. And by decreasing the extracted materials, they did the great role of disposing the waste matters.

  • PDF