• Title/Summary/Keyword: 횡방향 긴장

Search Result 20, Processing Time 0.024 seconds

Design Guide of Post-Tensioned Prestressed Concrete Pavement (포스트텐션 콘크리트 포장 공법 설계지침 개발)

  • Park, Hee-Beom;Kim, Seong-Min;Bae, Jong-Oh
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.17-18
    • /
    • 2010
  • This study was conducted to develop the design guide of PTCP (Post Tensioned Concrete Pavement). The behavior of PTCP was investigated by performing structural analyses and field experiments. Based on the results, the PTCP design guide was developed by determining the size of concrete slab, design environmental and vehicle loads, and amount and method of longitudinal and transverse tensioning.

  • PDF

Dynamic Behavior of External Post-tensioned Non-ballast Steel Plate Girder Railway Bridge (외부 후 긴장된 무도상 철도 판형교 동적 거동)

  • Park, Yong Gul;Park, Young Hoon;Choi, Dong Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3A
    • /
    • pp.315-322
    • /
    • 2008
  • The present study applied the external post tensioning reinforcement method for reinforcing a non-ballast steel plate girder railway bridge, and the effects of the strength of tendons and the level of post-tensioning force on the dynamic behavior are experimented and analyzed. According to the results of this study, the natural frequency was increased by the strength of tendons but it was decreased by the rise of post-tensioning force and as a consequence the introduction of post-tensioning force decreased natural frequency slightly. It was analyzed that further study is need to establish the exact relations between post-tensioning force and natural frequency. In addition, it was found that the dynamic displacement, dynamic bending stress and vertical acceleration were decreased by the external post-tensioning. On the other hand, external post-tensioning increased horizontal acceleration by up to 20%, which was around 70% of vertical acceleration. This needs further study.

The Influence of Unbonded Prestressing Force on the Lateral Torsional Stability of Girders (비부착 긴장력이 거더의 횡비틀림 안정성에 미치는 영향)

  • Lee, Jong-Han;Lee, Kun-Joon;Kighuta, Kabuyaya
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.3
    • /
    • pp.8-15
    • /
    • 2018
  • An experiment was carried out to evaluate the lateral torsional stability of a girder with respect to the location and magnitude of prestressing force. The test of evaluating the lateral displacement and stability of a girder could cause an unexpected result due to various parameters, such as material nonlinearity, initial geometric imperfections, prestressing force, and loading and support conditions. Therefore, a small model testing was programmed to control the various parameters and assess the lateral torsional stability with respect to the prestressing force. This study proposed and fabricated an experimental apparatus that can satisfy the loading and in-plane and out-of-plane support conditions and also contol the prestressing force. The result of the experiment showed that the lateral torsional stability increased when the prestressing force was applied in the bottom flange of the girder. As a result, this study proposed an analytical equation that can account for the effect of the prestressing force in the lateral torsional stability of a girder.

A Relation between Anchor Unbonded Length, Anchor Loads, and Wall Deflection in Tieback Anchored Wall (타이백 억지토류벽에서 앵커 자유장 및 앵커하중의 크기와 벽체변위와의 상관성)

  • 임유진
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.6
    • /
    • pp.187-200
    • /
    • 1999
  • An extensive investigation is performed to analyze the behavior of tieback anchored wall. Finite element method is used and several case histories are collected to investigate the relationship of wall deflection, anchor unbonded length, and anchor load. The finite element method can calculate wall deflection with changing the anchor unbonded length and the anchor load. Wall deflection normalized by excavation height can be related to anchor location so that it may produce a zone chart. It is found that a different chart showing the relation of the wall deflection, the anchor load, and anchor unbonded length can be constructed. It is necessary to collect more case histories considering soil conditions and to perform FE analysis extensively with changing bonded length to extend the capability of this relation chart into practice.

  • PDF

An Experimental Study on the Performance of Compression-Type Anchor for CFRP Tendons (CFRP 긴장재용 압착형 정착장치의 정착성능에 관한 실험적 연구)

  • Jung, Woo-Tai;Lee, Seung-Joo;Park, Young-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.5
    • /
    • pp.611-618
    • /
    • 2008
  • CFRP (carbon fiber reinforced polymer) tendons can be used as an alternative to solve the corrosion problem of steel tendons. Since CFRP tendons are vulnerable to transverse pressure and stress concentration, the conventional anchorage system used for steel tendons can create an unreliable load carrying capacity and may result in a premature failure. Therefore, it is necessary to develop the anchorage system that is well suited for CFRP tendons. There are many types of anchorage systems for CFRP tendons, which can be classified into three types: wedge-type anchorage, bond-type anchorage, and compression-type anchorage. This paper deals with the compression-type anchorage system manufactured through swaging technology. Based on the previous test results performed by the authors, the dimension of anchorage sleeve, the use and non-use of the insert, and the compression pressure on the sleeve have been selected as the major parameters affecting the performance of the compression-type anchorage. Some anchorage sleeves have been tapered to reduce the stress concentration. Test results revealed that the performance of the anchorage system depends mainly on the dimension and the compression pressure. It has been verified that the tapered sleeve can effectively reduce the stress concentration.

Analysis of Seismic Performance of Modular Containment Structure for Small Modular Reactor (소형 원자로용 모듈화 격납구조의 내진성능 분석)

  • Park, Woo-Ryong;Yhim, Sung-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.409-416
    • /
    • 2020
  • The seismic performance of a containment structure should be secured to maintain the structural soundness of a containment structure under various earthquakes that occur globally. Therefore, an analysis of the seismic performance of a modular containment structure for a small modular reactor is also required. To analyze the seismic performance of modular containment, FEM models with contact surfaces between the modules and tendon were prepared and the modal and seismic analyses were performed. The displacement, stress, and gap size of modular containment under earthquake wave were analyzed. The effects of the tendon force, friction coefficient, and earthquake wave on the seismic performance were analyzed. The seismic performance of monolithic containment was also analyzed for comparison. In the 1st and 2nd natural modes, which most likely affect, the modular containment showed horizontal dynamic behavior, which is similar to monolithic containment, because of the combined effects of the tendon force and friction force between modules. When the combined effect is sufficient, the seismic performance of the modular containment is secured over a certain level. An additional increase in seismic performance is expected when some material with a larger friction coefficient is adopted on the contact surface.

Effects of Design Parameters on Structural Performance of Precast Piers with Bonded Prestressing Steels (부착 긴장재를 가진 조립식 교각 설계변수의 구조성능에 미치는 영향)

  • Shim, Chang-Su;Yoon, Jae-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1A
    • /
    • pp.15-26
    • /
    • 2010
  • Quasi-static tests were conducted to evaluate structural performance of precast piers prestressed by bonded prestressing steels. Combinations of prestressing bars and normal reinforcing bars, embedded steel tubes and prestressing strands were used as continuous steels crossing the joints of a precast pier. Main design parameters were steel ratio, magnitude of prestress force, and section details. Flexural strength and energy dissipation capacity of precast columns with higher steel ratio showed better performance due to continuous steels after opening of the joints. Precast piers with embedded members showed stable behavior after reaching maximum loads resulting in higher displacement ductility and energy dissipation capacity increased as the introduced prestress increased. Self-centering behavior at early stages and stress increase of confining reinforcements were observed from highly prestressed columns. Combination of prestressing steels and normal reinforcing bars should be used in design to prevent rapid strength degradation after reaching the maximum load.

An Experimental Study for Performance of PSC-I Girders with 60MPa High-Strength Concrete (설계강도 60MPa급 고강도 PSC의 내하성능 검토)

  • Lee, Jae-Yong;Min, Kyung-Hwan;Yang, Jun-Mo;Cheong, Hai-Moon;Ahn, Tae-Song;Yoon, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.9-12
    • /
    • 2008
  • PSC-I girder is widely used in designing bridge. Currently partial advanced country have constructed bridge with high strength concrete, while in-country rather less concrete strength(40MPa) has been used to build bridge girder. So, this paper presents characteristics and behavior of member casted by high strength concrete to apply practically. For this aim, 4 girders were fabricated to investigate performance and structural behavior. Prior to test, structural analysis was performed with common program. Steel gages and concrete gage were filled up to measure longitudinal and vertical strain of reinforcement and concrete. Linear Variable Differential Transducer and concrete surface gage were also set to measure deflection and strain of concrete. Load-deflection relation and crack mode were analyzed at transfer and test and compared with the structural analysis

  • PDF

Evaluation of Seismic Performance of Prefabricated Bridge Piers with a Circular Solid Section (중실원형단면 조립식 교각의 내진 성능 평가)

  • Kim, Hyun-Ho;Shim, Chang-Su;Chung, Chul-Hun;Kim, Cheol-Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.3 s.55
    • /
    • pp.23-31
    • /
    • 2007
  • Fast bridge construction has been increasingly needed according to the changed construction environment. This paper deals with quasi-static tests on precast piers for bridge substructures. One of the most crucial aspect of the design of precast prestressed concrete bridge piers is the seismic performance. Seven precast pier elements were fabricated. The amount of prestressing bars, the prestressing force, and the location and number of the joint between segments were the main test parameters. Test results showed that the introduced axial prestress made the restoration of the deformation under small lateral displacement and minor damage. However, there was no effect of the prestress when the plastic hinge region was damaged severely due to large lateral displacement. Judging from the observed damage, the design of the joints in precast piers should be done for the first joint between the foundation and the pier segment. The amount of the necessary prestressing steel may be designed to satisfy the P-M diagram according to the service loads, not by having the same steel ratio as normal RC bridge piers. In order to satisfy the current required displacement ductility, it is necessary to have the same amount of the transverse reinforcements as RC piers. As the steel ratio increases, the energy absorption capacity increases. The number of joints showed a little influence on the energy absorption capacity.

An Experimental Study on Splitting Bond Strength of RC Column Reinforced with External Steel-Band (스틸밴드로 외부 보강된 철근콘크리트 기둥의 부착강도에 관한 실험적 연구)

  • Kim, Chang-Sik;Yoon, Seung-Joe;Ho, Seung-Woong;Yoon, Pil-Joong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.41-49
    • /
    • 2014
  • In order to investigation splitting bond strength of the deformed longitudinal reinforcing bars in the R C members strengthened laterally with the external steel-band, a total 9 sets of test re-bars with and without active confining force given by the external steel-band are pulled monotonically until failure. Test results indicate that the bond strength becomes higher with the increase in number of steel-band sets and their initial stress magnitude. This is due to the active confining force given by the steel-band, and passive confining forces given by the steel-band and transverse reinforcements, in which the passive confinement effect varies depending on the magnitude of active confining force. An equation to estimate the splitting bond strengths for the R C members strengthened laterally with the external steel-band is developed based on the several experimental results of the present study.