• Title/Summary/Keyword: 횡류팬

Search Result 16, Processing Time 0.025 seconds

Development of Visualization Technique for Analysis of Internal Flow for Cross-flow Fan (횡류팬 내부 유동 분석을 위한 가시화 기법 개발)

  • Lee, A-Mi;Han, Kyu-Il;Joo, Jae-Man;Na, Seon-Uk;Kim, Dong-Won;Ko, Han-Seo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.515-516
    • /
    • 2006
  • Internal and inlet flows of a cross-flow fan have been visualized using a particle image velocimetry(PIV) to analyze a relationship with a performance of a room air conditioner(RAC). A test model which has a geometric similarity with the real RAC has been manufactured for the experiment and the flow characteristics have been analyzed with various flow rates and inlet grill angles for the cross-flow fan. The experimental results using the PIV technique have been compared with the existing numerical results. Also, a location and movement of an eccentric vortex which can affect the performance and noise of the RAC has been investigated by the PIV with various flow rates and inlet grill angles.

  • PDF

The Influence of the Intake Regions of the Cross-flow fan on the Performance and Fan Noise (횡류팬 흡입구의 위치가 성능 및 소음 특성에 미치는 영향)

  • Kim, Jin Baek;Choi, Weon Seok;Lee, Jai Kwon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.78-82
    • /
    • 2004
  • The cross-flow fan which is used for air-conditioner indoor units were studied experimentally. The recent trend shows that the room air-conditioners need to be good-looking. According to the visual design concepts the intake regions of the fan can vary, which leads to the loss of the performance and the increase of the noise of the fan. In order to optimize the performance of the fan and minimize the aerodynamic noise for the system, the performance characteristics and the noise of the cross-flow fan have been investigated at the various conditions of the intake region of the unit.

  • PDF

Flow Analyses in a Cross-Flow Fan (횡류팬 내부의 유동해석)

  • Lee H G.;Park H. K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.05a
    • /
    • pp.65-70
    • /
    • 2002
  • Cross-Flow Fan(CFF) are widely used lot industrial equipments and household electric appliances. A design method for CFFs, however, has not been well established because of the complexity of the internal flow. Numerical analysis was performed by using STAR-CD. In this study present the internal flow of CFF, which has varies pin number, and their flowrate were compared

  • PDF

A Study on Characteristics of Condensation for RAC Using Flow Visualization Technique (유동 가시화 기법을 이용한 RAC의 이슬 맺힘 특성에 관한 연구)

  • Lee, A-Mi;Kim, Dong-Won;Na, Seon-Uk;Ko, Han-Seo
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3092-3097
    • /
    • 2007
  • Although noise of a RAC can be reduced effectively by decreasing RPM, condensation problems can occur to reduce reliability of the RAC for low RPM. Thus, this research has been performed to propose a design guideline of the RAC for low-noise RPM with high reliability. The internal and external flows of the RAC have been visualized and analyzed by a PIV technique to solve the condensation problem at an outlet and impeller. Then, the design guideline has been proposed by the analyzed results and confirmed by wind-tunnel and noise tests to reduce the condensation problem. Finally the shapes of the outlet with reduced condensation problem and the impeller with low noise have been obtained in this study.

  • PDF

Numerical Analysis of Flow-Induced Noise and Fan Performance in Suction Nozzle of a Vacuum Cleaner with a Double-Blade Fan (이중 블레이드 팬이 장착된 진공청소기 흡입 노즐내 유로 유동 소음 및 팬 성능 해석)

  • Park, I-Sun;Sohn, Chae-Hoon;Lee, Sung-Cheol;Oh, Jang-Keun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2632-2637
    • /
    • 2007
  • Rotary performance and flow resistance induced by each element in suction nozzle of a vacuum cleaner with a double-blade rotary fan are investigated numerically and its relation with flow-induced noise and rotary performance is examined. Flow resistance and vorticity in suction nozzle are calculated and it is found that they are closely related with flow-induced noise. Gap between double blades, adoption of cross-flow fan, enlargement of flow inlet area, and optimization of blade number are tested for noise reduction. Finally, the effects of each method are verified experimentally. It is found that several combinations of the proposed methods can be adopted for noise reduction although the degree of reduction is not much.

  • PDF

Reduction of Flow-Induced Noise in Suction Nozzle of a Vacuum Cleaner by Adopting a Cross-Flow Fan (횡류팬을 적용한 진공청소기 흡입노즐내 유동 소음 저감에 관한 연구)

  • Park, I-Sun;Sohn, Chae-Hoon;Lee, Sung-Cheol;Oh, Jang-Keun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.935-938
    • /
    • 2007
  • In suction nozzle of a vacuum cleaner, where flow-induced noise is generated mainly by flow resistance, several ideas to reduce noise are investigated. To increase fan performance, blade number is optimized and a centrifugal fan is replaced by a cross-flow fan, In addition, gear ratio of fan to drum brush is changed. It is found that fan performance is increased by adopting these methods. Next, the blade height of the fan is decreased to reduce sound pressure level, which causes inevitably decrease in fan performance. Eventually, flow-induced noise is reduced by 6.3 dBA in its overall level with the fan performance maintained.

  • PDF

Optimum Design of a Cross Flow Fan (횡류팬의 최적설계방안)

  • Kim Dong-Hoon;Park Hyung-Koo
    • Journal of computational fluids engineering
    • /
    • v.8 no.4
    • /
    • pp.50-57
    • /
    • 2003
  • Cross-flow fans are widely used in various applications, due to their large capacity of mass flow and size compactness. The flow field of the cross-flow fan is, however, complex and has many design parameters. Thus, the general design guide has not been sufficiently established yet and the design strategies of cross-flow fans have been mostly based on experiments. In the present study, the performance and their two-dimensional flow characteristics are numerically analyzed by using the STAR-CD(commercial computational fluid dynamics code). The simulation is done by varying the several design parameters such as the impeller blade shapes and the gap between the stabilizer and impeller. The computational results are compared with the experimental data at the fan outlet region. Finally, some helpful guides for the optimum design of cross-flow fans are proposed.

NUMERICAL PREDICTION OF THE CROSS-FLOW FAN PERFORMANCE AND NOISE CHARACTERISTICS BY UNSTRUCTURED FLOW SOLVER ALGORITHM (비정렬 격자기법을 이용한 횡류팬(Cross-Flow Fan)의 비정상 유동해석)

  • Cho Yong;Moon Young J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.11a
    • /
    • pp.36-41
    • /
    • 1998
  • The cross-flow fan performance and its sound noise characteristics are predicted by computational methods. The unsteady incompressible Navier-Stokes equations in moving coordinates are solved by a SMAC method on unstructured triangular meshes, using a sliding mesh technique at the interface between the domain rotating with blades and the rest stationary part. The computationally predicted fan performance was favorably compared with experiment, and some numerical aspects of simulating the cross-flow fan are discussed. With the computed unsteady flow field, aeroacoustic sound noise of the fan is predicted by the Lighthill-Curie equation. The unsteady surface pressure fluctuations on stabilizer enables a prediction of BPF noise of the uniform pitch blade fan quite accurately. The aeroacoustic sound noise characteristics of both uniform and random pitch blade fans are also examined by SPL spectrum analysis.

  • PDF

Optimum Design of a Cross Flow Fan (횡류팬의 최적설계방안)

  • Kim D. H.;Park H. K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.08a
    • /
    • pp.176-181
    • /
    • 2003
  • The cross-flow fans are widely used in various applications, due to their large capacity of mass flow and the size compactness. The flow fields of the cross-flow fan is, however, complex and it has many design parameters. Thus the general design guide has not sufficiently established yet, and the design strategies of cross-flow fans have been based on experiments. In the present study, the cross-flow fan performance and its two-dimensional flow characteristics are numerically analyzed by using the STAR-CD. The simulation is done by varying the several design parameters such as impeller blade shapes, the gap between the stabilizer and impeller. The computational results are compared with the experimental data at the fan outlet region. Finally some helpful guides for the optimum design of the cross-flow fan are proposed.

  • PDF