• Title/Summary/Keyword: 회전 표적

Search Result 111, Processing Time 0.027 seconds

Quality Assurance of Volumetric Modulated Arc Therapy Using the Dynalog Files (다이나로그 파일을 이용한 부피세기조절회전치료의 정도관리)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Kim, Yon-Lae;Yang, Hyung-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.577-585
    • /
    • 2016
  • The purpose of this study is to evaluate the accuracy of beam delivery QA software using the MLC dynalog file, about the VMAT plan with AAPM TG-119 protocol. The Clinac iX with a built-in 120 MLC was used to acquire the MLC dynalog file be imported in MobiusFx(MFX). To establish VMAT plan, Oncentra RTP system was used target and organ structures were contoured in Im'RT phantom. For evaluation of dose distribution was evaluated by using gamma index, and the point dose was evaluated by using the CC13 ion chamber in Im'RT phantom. For the evaluation of point dose, the mean of relative error between measured and calculated value was $1.41{\pm}0.92%$(Target) and $0.89{\pm}0.86%$(OAR), the confidence limit were 3.21(96.79%, Target) and 2.58(97.42%, OAR). For the evaluation of dose distribution, in case of $Delta^{4PT}$, the average percentage of passing rate were $99.78{\pm}0.2%$(3%/3 mm), $96.86{\pm}1.76%$(2%/2 mm). In case of MFX, the average percentage of passing rate were $99.90{\pm}0.14%$(3%/3 mm), $97.98{\pm}1.97%$(2%/2 mm), the confidence limits(CL) were in case of $Delta^{4PT}$ 0.62(99.38%, 3%/3 mm), 6.6(93.4%, 2%/2 mm), in case of MFX, 0.38(99.62%, 3%/3 mm), 5.88(94.12%, 2%/2 mm). In this study, we performed VMAT QA method using dynamic MLC log file compare to binary diode array chamber. All analyzed results were satisfied with acceptance criteria based on TG-119 protocol.

Simulation of Spinning Concentric Annular Ring Reticle Seeker and IRCCM using Correlation Coefficient (회전 동심원 레티클 탐색기의 시뮬레이션 및 상관계수를 이용한 반대응기법)

  • 홍현기;장성갑;두경수;최종수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5A
    • /
    • pp.763-771
    • /
    • 2000
  • Reticle systems, which are widely used in infrared (IR) missile seekers, are considered to be the classical approach for estimating the position of a target in the field of view (FOV). This paper presents an effective simulation tool that gives tracking results of the concentric annular ring reticle seeker. We construct the concentric annular ring reticle seeker on Matlab-Simulink for a dynamic simulation. Our simulation model provides tracking results in various cases, and is applicable to the study of the development of the advanced seekers. While false targets such as flares are presented in the FOV, simulation results show that the existing seeker cannot determine a precise target location. In order to decrease the susceptibility to countermeasures such as flares, we propose an efficient counter-countermeasure using the correlated relationship of modulated signals and the references. We have ascertained that the reticle seeker using our technique make more effective target tracking than previous seekers.

  • PDF

Verification of Target Position in Stereotactic Radiosurgery Based on Photon Knife System (Photon Knife 시스템에 근거한 뇌정위 방사선수술에서 표적위치 확인)

  • 최태진;김진희;김옥배
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.99-107
    • /
    • 2003
  • This study was performed to prepare the verification film for localizing beam-target position with the Photon Knife radiosurgery system (PKRS) using linear accelerator(Mitsubishi, Model ML-15MDX). We developed a laser calibration system using a reticle of transparent lucite to detect Inlet and outlet beams. We verified fixation of the second collimator with film mounted on a holder in the shape of an octagon block 5cm apart from the isocenter. The film was exposed to photon beams of linear accelerator at an interval of 45 degrees during the gantry movement. There were no shifts in the beam of the second collimator during gantry movement. We used a position marker which is designed a head-shaped small lead block and a 10 mm in diameter of steel bead in the plastic tube. The position marker helped to verify the beam directions with patient position in multi-arc and trans-multi-arc of PKRS The verification of beam alignments showed an average 0.8$\pm$0.26 mm discrepancy in LINAC-gram images of PKRS. In our study, the couch movement was $\pm$5 mm laterally, while it shook $\pm$ 2 mm toward the couch axis. The couch, however, was immediately returned to the initial site after shaking. Thus, we postulate that the beam-target position(s) should be verified with LINAC-gram in a stereotactic radiosurgery system to achieve the accuracy of beam-target alignment.

  • PDF

Evaluation of beam delivery accuracy for Small sized lung SBRT in low density lung tissue (Small sized lung SBRT 치료시 폐 실질 조직에서의 계획선량 전달 정확성 평가)

  • Oh, Hye Gyung;Son, Sang Jun;Park, Jang Pil;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.7-15
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate beam delivery accuracy for small sized lung SBRT through experiment. In order to assess the accuracy, Eclipse TPS(Treatment planning system) equipped Acuros XB and radiochromic film were used for the dose distribution. Comparing calculated and measured dose distribution, evaluated the margin for PTV(Planning target volume) in lung tissue. Materials and Methods : Acquiring CT images for Rando phantom, planned virtual target volume by size(diameter 2, 3, 4, 5 cm) in right lung. All plans were normalized to the target Volume=prescribed 95 % with 6MV FFF VMAT 2 Arc. To compare with calculated and measured dose distribution, film was inserted in rando phantom and irradiated in axial direction. The indexes of evaluation are percentage difference(%Diff) for absolute dose, RMSE(Root-mean-square-error) value for relative dose, coverage ratio and average dose in PTV. Results: The maximum difference at center point was -4.65 % in diameter 2 cm size. And the RMSE value between the calculated and measured off-axis dose distribution indicated that the measured dose distribution in diameter 2 cm was different from calculated and inaccurate compare to diameter 5 cm. In addition, Distance prescribed 95 % dose($D_{95}$) in diameter 2 cm was not covered in PTV and average dose value was lowest in all sizes. Conclusion: This study demonstrated that small sized PTV was not enough covered with prescribed dose in low density lung tissue. All indexes of experimental results in diameter 2 cm were much different from other sizes. It is showed that minimized PTV is not accurate and affects the results of radiation therapy. It is considered that extended margin at small PTV in low density lung tissue for enhancing target center dose is necessary and don't need to constraint Maximum dose in optimization.

Simulation of 2-color Concentric Annular Ring Reticle Seeker and Counter-countermeasure using LMS Algorithm (2-color 동심원 레티클 탐색기의 시뮬레이션 및 LMS 방법을 이용한 반대응능력)

  • 홍현기
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.12A
    • /
    • pp.1990-1999
    • /
    • 2001
  • This paper presents a dynamic simulation loop that gives tracking results of 2-color concentric annular ring (CAR) reticle seeker. Our simulation tool includes the target/flare model and a proportional navigation guidance (PNG) loop. The CAR reticle system performances and the flare effects are analyzed in various scenarios. When a flare is present in the field of view (FOV), the simulation results show that the reticle seeker cannot keep a precise target tracking. In this paper, we propose 2-color counter-countermeasure (CCM) using the least mean square (LMS) method to cope with a presence of IR flare. The proposed method makes a simultaneous process in two infrared (IR) wavelength bands: MWIR add SWIR. The simulation results have shown that our adaptive IRCCM algorithm can achieve an effective cancellation of the flare signal with a relatively high intensity.

  • PDF

Three-dimensional Distortion-tolerant Object Recognition using Computational Integral Imaging and Statistical Pattern Analysis (집적 영상의 복원과 통계적 패턴분석을 이용한 왜곡에 강인한 3차원 물체 인식)

  • Yeom, Seok-Won;Lee, Dong-Su;Son, Jung-Young;Kim, Shin-Hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.10B
    • /
    • pp.1111-1116
    • /
    • 2009
  • In this paper, we discuss distortion-tolerant pattern recognition using computational integral imaging reconstruction. Three-dimensional object information is captured by the integral imaging pick-up process. The captured information is numerically reconstructed at arbitrary depth-levels by averaging the corresponding pixels. We apply Fisher linear discriminant analysis combined with principal component analysis to computationally reconstructed images for the distortion-tolerant recognition. Fisher linear discriminant analysis maximizes the discrimination capability between classes and principal component analysis reduces the dimensionality with the minimum mean squared errors between the original and the restored images. The presented methods provide the promising results for the classification of out-of-plane rotated objects.

A Measurement of Proton Beam Energy using Carbon Target for Medical Cyclotron (탄소 표적물을 사용한 의료용 싸이클로트론의 양성자 에너지 측정)

  • Chai, Jong-Seo;Ha, Jang-Ho;Kim, Yu-Seok;Lee, Dong-Hun;Lee, Min-Yong;Hong, Seong-Seok
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.3
    • /
    • pp.350-354
    • /
    • 1995
  • 한국 원자력 연구소 부설 원자력병원에 설치된 AVF 싸이클로트론을 이용하여 요즈음 핵의학에 널리 사용되는 PET 용 싸이클로트론의 에너지를 검정 할 수 있고 양성자 과잉 핵종인 싸이클로트론 동위원소의 생산 수율에 중요한 변수인 양성자에너지를 탄소에 입사시켜 입사빔의 Range와 에너지를 측정하는 방법을 제시하였다. 본 실험에서 사용된 양성자 빔의 양성자 에너지는 35 MeV와 50 MeV 사이였으며, 탄소 막은 두께 6.3mm, 밀도 $1.712 g/cm^3$를 사용하였다. 탄소 표적물을 $0.9^{\circ}$씩 스텝 모터를 사용하여 회전시킴으로 두께를 변화 시켜 공칭 에너지에 대한 Range를 측정함으로써 입사된 양성자의 에너지를 구하였고 이를 인출반경과 RF주파수를 바탕으로 상대론 적으로 계산된 에너지와 비교하였다.

  • PDF

How Image Quality Affects Determination of Target Displacement When Using kV Cone-beam Computed Tomography (CBCT) (kV Cone-beam CT를 사용한 치료준비에서 재구성 영상의 품질이 표적 위치 결정에 미치는 영향)

  • Oh, Seung-Jong;Kim, Si-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.207-211
    • /
    • 2006
  • The advent of kV cone-beam computed tomography (CBCT) integrated with a linear accelerator allows for more accurate Image-guided radiotherapy (IGRT). IGRT is the technique that corrects target displacement based on internal body information. To do this, the CBCT Image set is acquired just before the beam is delivered and registered with the simulation CT Image set. In this study, we compare the registration results according to the CBCT's reconstruction quality (either high or medium). A total of 56 CBCT projection data from 6 patients were analyzed. The translation vector differences were within 1 mm in all but 3 cases. For rotation displacement difference, components of all three axes were considered and 3 out of 168 ($56{\times}3$ axes) cases showed more than lo of rotation differences.

  • PDF

A Study for Vision-based Estimation Algorithm of Moving Target Using Aiming Unit of Unguided Rocket (무유도 로켓의 조준 장치를 이용한 영상 기반 이동 표적 정보 추정 기법 연구)

  • Song, Jin-Mo;Lee, Sang-Hoon;Do, Joo-Cheol;Park, Tai-Sun;Bae, Jong-Sue
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.315-327
    • /
    • 2017
  • In this paper, we present a method for estimating of position and velocity of a moving target by using the range and the bearing measurements from multiple sensors of aiming unit. In many cases, conventional low cost gyro sensor and a portable laser range finder(LRF) degrade the accuracy of estimation. To enhance these problems, we propose two methods. The first is background image tracking and the other is principal component analysis (PCA). The background tracking is used to assist the low cost gyro censor. And the PCA is used to cope with the problems of a portable LRF. In this paper, we prove that our method is robust with respect to low-frequency, biased and noisy inputs. We also present a comparison between our method and the extended Kalman filter(EKF).

High Frequency Scattering from Cylindrical Scatterer (원통형 산란체의 고주파 산란 특성)

  • Kim Kitaek;Yoon Kwan-Seob;La Hyoungsul;Na Jungyul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.8
    • /
    • pp.441-446
    • /
    • 2005
  • This paper presents the changes of acoustic scattering pattern from a single cylinder and two identical cylinders in both theoretical calculations and experimental measurements. Bi-static scattering pattern by single cylinder and two parallel cylinders (length 2m, radius 30mm) was measured in $5m\times5m\times5m$ water tank using high frequency projector (120 kHz) and hydrophone. The results show similar agreement between experiment and theory. In case of single cylinder scattering. omni-directional pattern was observed in backward but there are fluctuations or target strength in forward. Interference between each cylinder's scattering fields produce fluctuations of target strength in all directions of two cylinders.