• Title/Summary/Keyword: 회전효과

Search Result 1,181, Processing Time 0.025 seconds

Evaluation of the Effect of Operation of Toothbrushing Room in between Two Elementary Schools (일부 초등학교 양치교실 운영 효과 평가)

  • Seong, Mi-Gyung;Kwun, Hyeon-Sook;Moon, Sook-Ryeon;Ryu, Hae-Gyum
    • Journal of dental hygiene science
    • /
    • v.15 no.1
    • /
    • pp.24-31
    • /
    • 2015
  • This research was conducted in order to examine the effect of tooth brushing room M elementary school in Changwon-city and to provide foundation data for effective project operation afterwards. The subjects were 347 students at the M elementary school where the tooth brushing room was being taught. The control group is 289 students at J elementary school where the tooth brushing room was not being taught. Research and analysis were carried out with structured survey and examination of decayed, missing, filled teeth (DMFT) index, decayed, missing, filled tooth surface (DMFS) index and O'leary index. The data was analysed by IBM SPSS Statistics ver. 19.0 program and the result is as follows: Depends on the tooth brushing room there was difference in statistical significance in filling teeth, sealant tooth surface, filling tooth surface, missing tooth surface, DMFS, O'leary index between the subject and control group. The less the frequency of brushing, the higher the DMFT index. Negative correlation was statistically significant. With incorrect brushing method, the less the frequency, the higher the DMFS index, Negative correlation was statistically significant. When the tooth brushing room was being implemented, O'leary index became low, negative correlation was statistically significant. As a result, in order to continue the effective operation of tooth brushing room, constant supervision and monitoring on students should be acutely needed by a principal, a school nurse and teachers in charge. Also together with a systemized cooperation between a health center and a nearby university's related majors departments, the research proposes to execute constant oral health education and to expand the implementation project of the tooth brushing room at nearby elementary schools.

Evaluation of Image Quality in Micro-CT System Using Constrained Total Variation (TV) Minimization (Micro-CT 시스템에서 제한된 조건의 Total Variation (TV) Minimization을 이용한 영상화질 평가)

  • Jo, Byung-Du;Choi, Jong-Hwa;Kim, Yun-Hwan;Lee, Kyung-Ho;Kim, Dae-Hong;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.252-260
    • /
    • 2012
  • The reduction of radiation dose from x-ray is a main concern in computed tomography (CT) imaging due to the side-effect of the dose on human body. Recently, the various methods for dose reduction have been studied in CT and one of the method is a iterative reconstruction based on total variation (TV) minimization at few-views data. In this paper, we evaluated the image quality between total variation (TV) minimization algorithm and Feldkam-Davis-kress (FDK) algorithm in micro computed tomography (CT). To evaluate the effect of TV minimization algorithm, we produced a cylindrical phantom including contrast media, water, air inserts. We can acquire maximum 400 projection views per rotation of the x-ray tube and detector. 20, 50, 90, 180 projection data were chosen for evaluating the level of image restoration by TV minimization. The phantom and mouse image reconstructed with FDK algorithm at 400 projection data used as a reference image for comparing with TV minimization and FDK algorithm at few-views. Contrast-to-noise ratio (CNR), Universal quality index (UQI) were used as a image evaluation metric. When projection data are not insufficient, our results show that the image quality of reconstructed with TV minimization is similar to reconstructed image with FDK at 400 view. In the cylindrical phantom study, the CNR of TV image was 5.86, FDK image was 5.65 and FDK-reference was 5.98 at 90-views. The CNR of TV image 0.21 higher than FDK image CNR at 90-views. UQI of TV image was 0.99 and FDK image was 0.81 at 90-views. where, the number of projection is 90, the UQI of TV image 0.18 higher than FDK image at 90-views. In the mouse study UQI of TV image was 0.91, FDK was 0.83 at 90-views. the UQI of TV image 0.08 higher than FDK image at 90-views. In cylindrical phantom image and mouse image study, TV minimization algorithm shows the best performance in artifact reduction and preserving edges at few view data. Therefore, TV minimization can potentially be expected to reduce patient dose in clinics.

Tranexamic Acid Reduces Postoperative Blood Loss in Reverse Total Shoulder Arthroplasty (역행성 견관절 전치환술에서 트라넥삼산의 출혈 및 수혈 감소 효과)

  • Park, Kee Young;Kim, In Bo;Kim, Eun Yeol;Lee, Kwang Suk
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.5
    • /
    • pp.391-397
    • /
    • 2021
  • Purpose: Tranexamic acid (TXA) can reduce perioperative blood loss and the frequency of blood transfusions in lower extremity surgery. On the other hand, the effects of TXA on reverse total shoulder arthroplasty (rTSA) remain undetermined. This study evaluated the efficacy of TXA on perioperative blood loss, transfusion requirements, and the change in the hemotologic index. Materials and Methods: This study evaluated patients who underwent rTSA from September 2009 to July 2020. The patients were classified into two groups. The TXA group were administered TXA intravenously and topical TXA during surgery. The non-TXA group was not administered TXA. The quantity of hemovac drainage, which represented the postoperative blood loss, transfusion requirements, and postoperative change in hemoglobin and hematocrit level, were recorded. Results: The TXA and non-TXA groups consisted of 93 and 84 patients, respectively. The preoperative demographics showed no significant differences in age (72.0±7.0 vs. 71.5±5.8, p=0.656), sex (male:female, 28:65 vs. 23:61, p=0.689) and the prevalence of hypertension and diabetes (hypertension:diabetes:both, 36:3:13 vs. 32:3:8, p=0.806) between the two groups. There were significant differences in the requirements of transfusion (0 vs. 9, p=0.001), hemovac drainage at the 1st (98.8±61.2 ml vs. 162.7±98.8 ml, p<0.001), the 2nd postoperative day (73.8±48.4 ml vs. 91.5±54.5 ml, p=0.024), hemoglobin level at the 1st (11.7±1.2 g/dl vs. 11.2±1.4 g/dl, p=0.048), 3rd (10.9±1.2 g/dl vs. 10.2±1.2 g/dl, p<0.001), and 6th (11.2±1.3 g/dl vs. 10.7±1.3 g/dl, p=0.020) postoperative day, and the hematocrit level at the 1st (35.0%±3.6% vs. 32.5%±3.8%, p=0.001), 3rd (32.3%±5.0% vs. 29.8%±3.6%, p<0.001), and 6th (33.5%±3.8% vs. 31.5%±3.7%, p<0.001) postoperative day between the two groups. Conclusion: Intravenous and topical intra-articular TXA can reduce the transfusion requirement and blood loss in rTSA.

Measuring Intracellular Mycobacterial Killing Using a Human Whole Blood Assay (인체 전혈 모델을 이용한 세포내 결핵균 살균력에 관한 연구)

  • Cheon, Seon-Hee;Song, Ho-Yeon;Lee, Eun-Hee;Oh, Hee-Jung;Kang, In-Sook;Cho, Ji-Yoon;Hong, Young-Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.5
    • /
    • pp.497-509
    • /
    • 2002
  • Background : The mechanisms through which cellular activation results in intracellular mycobacterial killing is only partially understood. However, in vitro studies of human immunity to Mycobacterium tuberculosis have been largely modeled on the work reported by Crowle, which is complicated by several factors. The whole blood culture is simple and allows the simultaneous analysis of the relationship between bacterial killing and the effect of effector cells and humoral factors. In this study, we attempted to determine the extent to which M. tuberculosis is killed in a human whole blood culture and to explore the role of the host and microbial factor in this process. Methods : The PPD positive subject were compared to the umbilical cord blood and patients with tuberculosis, diabetes and lung cancer. The culture is performed using heparinized whole blood diluted with a culture medium and infected with a low number of M. avium or M. tuberculosis $H_{37}Ra$ for 4 days by rotating the culture in a $37^{\circ}C$, 5% $CO_2$ incubator. In some experiments, methlprednisolone- or pentoxifyline were used to inhibit the immune response. To assess the role of the T-cell subsets, CD4+, CD8+ T-cells or both were removed from the blood using magnetic beads. The ${\Delta}$ log killing ratio was defined using a CFU assay as the difference in the log number of viable organisms in the completed culture compared to the inoculum. Results : 1. A trend was noted toward the improved killing of mycobacteria in PPD+ subjects comparing to the umbilical cord blood but there was no specific difference in the patients with tuberculosis, diabetes and lung cancer. 2. Methylprednisolone and pentoxifyline adversely affected the killing in the PPD+ subjects umbilical cord blood and patients with tuberculosis. 3. The deletion of CD4+ or CD8+ T-lymphocytes adversely affected the killing of M. avium and M. tuberculosis $H_{37}Ra$ by PPD+ subjects. Deletion of both cell types had an additive effect, particularly in M. tuberculosis $H_{37}Ra$. 4. A significantly improved mycobacterial killing was noted after chemotherapy in patients with tuberculosis and the ${\Delta}$ logKR continuously decreased in a 3 and 4 days of whole blood culture. Conclusion : The in vitro bactericidal assay by human whole blood culture model was settled using a CFU assay. However, the host immunity to M. tuberculosis was not apparent in the human whole blood culture bactericidal assay, and patients with tuberculosis showed markedly improved bacterial killing after anti-tuberculous chemotherapy compared to before. The simplicity of a whole blood culture facilitates its inclusion in a clinical trial and it may have a potential role as a surrogate marker in a TB vaccine trial.

Evaluation on Usefulness of Stereotactic Radio Surgery using $Fraxion^{(R)}$ System ($Fraxion^{(R)}$ System을 이용한 뇌 정위적 방사선 수술 유용성 평가)

  • Kim, Tae Won;Park, Kwang Woo;Ha, Jin Sook;Jeon, Mi Jin;Cho, Yoon Jin;Kim, Sei Joon;Kim, Jong Dae;Shin, Dong Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.345-354
    • /
    • 2014
  • Purpose : We evaluated the usefulness of $Fraxion^{(R)}$ system and s-thermoplastic mask by analyzing setup error when stereotactic radiousurgery (SRS) was treated for brain metastasis. Materials and Methods : 6 patients who received definite diagnosis as brain metastasis between May 2014 and October 2014 were selected. 3 patients were immobilized s-thermoplastic mask and mouthpiece (group1), while $Fraxion^{(R)}$ system was used for the other 3 patients (group2). Cone Beam Computerized Tomography (CBCT) scan was acquired to register planning CT scan. The registration offset was compared for each group. We compared and reported the errors using maximum, minimum, mean, and standard deviation of registration offsets. Furthermore, We used the same method as patient specific quality assurance to verify absorbed dose of PTV. Results : The setup error which is registration offset was reduced 83% in x, 40% in y, and 92% in z-direction when $Fraxion^{(R)}$ system was used compared to the case of using s-thermoplastic mask and mouthpiece. In addition, using $Fraxion^{(R)}$ system showed improved results in rotational components, pitch (rotation along x-axis), roll (y), and yaw (z) which were reduced 64, 88, and 87% respectively compared to the case of using s-thermoplastic mask and mouthpiece. In dosimetry results, when s-thermoplastic mask and mouthpiece used, absorbed dose was reduce 83% compared to before and after registration. However, using $Fraxion^{(R)}$ system showed only 1.9%. All percentage were calculated with respect to average value. Conclusion : Using $Fraxion^{(R)}$ system including mouthpiece, Fraxion frame, frontpiece, and thermoplastic mask, showed better repeatability and precision compared to using s-thermoplastic mask and mouthpiece, which is consequently considered as more improved immobilization system.

The evaluation of properties for radiation therapy techniques with flattening filter-free beam and usefulness of time and economy to a patient with the radiation therapy (Flattening filter-free beam을 이용한 방사선 치료 기법의 특성 및 환자의 시간적.경제적 유용성 평가)

  • Goo, Jang Hyeon;Won, Hui Su;Hong, Joo Wan;Chang, Nam Jun;Park, Jin Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.363-368
    • /
    • 2014
  • Purpose : The aim of this study was to appraise properties for radiation therapy techniques and effectiveness of time and economy to a patient in the case of applying flattening filter-free (3F) and flattening filter (2F) beam to the radiation therapy. Materials and Methods : Alderson rando phantom was scanned for computed tomography image. Treatment plans for intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and stereotactic body radiation therapy (SBRT) with 3F and 2F beam were designed for prostate cancer. To evaluate the differences between the 3F and 2F beam, total monitor units (MUs), beam on time (BOT) and gantry rotation time (GRT) were used and measured with $TrueBeam^{TM}$ STx and Surveillance And Measurement (SAM) 940 detector was used for photoneutron emitted by using 3F and 2F. To assess temporal and economical aspect for a patient, total treatment periods and medical fees were estimated. Results : In using 3F beam, total MUs in IMRT plan increased the highest up to 34.0% and in the test of BOT, GRT and photoneutron, the values in SBRT plan decreased the lowest 39.8, 38.6 and 48.1%, respectively. In the temporal and economical aspect, there were no differences between 3F and 2F beam in all of plans and the results showed that 10 days and 169,560 won was lowest in SBRT plan. Conclusion : According as the results, total MUs increased by using 3F beam than 2F beam but BOT, GRT and photoneutron decreased. From above the results, using 3F beam can decrease intra-fraction setup error and risk of radiation-induced secondary malignancy. But, using 3F beam did not make the benefits of temporal and economical aspect for a patient with the radiation therapy.

Studies on the Effects of Amylase Addition to Rice Extrusion on the Rheological Properties of the Extrudate for Weaning Food Base (압출조리를 이용한 쌀 이유식 제조에서 아밀라제 첨가가 물성변화에 미치는 효과)

  • Lee, Gang-Gweon;Kim, Ji-Yong;Lee, Cherl-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.670-678
    • /
    • 1994
  • The effects of amylase addition during extrusion cooking of rice on the physico-chemical properties of the extrudates were investigated in order to develop rice-based Korean style weaning food products. A laboratory-built single screw extruder was used, the enzymes used were Termamyl 120LS(amylase from Bacillus licheniformis, NOVO Co.), BAN 240L(amylase from Bacillus amylolichuefaciens, NOVO Co.) and malt powder. By the addition of enzymes, the water soluble index of the extrudates increased by 3 times compared to that of the extrudates without enzyme and the concentration of reducing sugar in the extrudates increased drastically at 28 feed moisture. The gel permeation chromatographic pattern showed that the large molecular starch fractions diminished by the addition of enzyme during extrusion and the low molecular fraction increased. The residual enzyme activity in the extrudate were 27% for the most thermo-resistance enzyme by treating at $140^{\circ}C$ in the metering section of the extruder. The sediment volume of the extrudate dispersion increased as the metering section temperature increased to $140^{\circ}C$ . By the addition of enzymes the viscosity of extrudate dispersion was redused $1/4{\sim}1/200$ of that of the extrudates without enzyme. It allowed to use 1.8 times of solid material to the weaning food formulation to attain the same level of consistency as the commercial products. It proves that the addition of amylase during rice extrusion is effective to increase the energy density of weaning food by starch degradation, which results in the increases of water solubility, reducing sugar content, dispersibility and fluidability.

  • PDF

The Kinematics Analysis of the Badminton High Clear Motion in Woman Middle School Student (여자중학생 배드민턴 하이클리어 동작의 운동학적 분석)

  • Kim, Chang-Bum;Ryu, Jae-Kwang
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.91-107
    • /
    • 2002
  • This research got the following conclusion as result that analyzed high clear action kinematically to 4 C girls' junior high school badminton players who are situated in Chungchong-bukdo. 1. Most of the subject didn't rotate their right shoulder and elbow joint at back swing and moved speedy to shuttle cock. And an cooperation action of joint decreases displaying only a good action on both subject`s specification joint part. 2. When the subject S1 and S2 swing slowly and largely the joint of shoulder and elbow and then the speed of right wrist and racket head is fast, the cooperation action of joint is better than other subject. 3. An angle change of right shoulder showed angle that all subjects are great being caused in softness of joint and angular velocity was exposed that load enough Impact force and increase the speed of racket head as angular velocity decreases rapidly in Impact except subject S3. 4. All subjects of right elbow angle change showed similar form and was exposed that subject S2 sees form of impact stage serious bends from back swing and do not use force effectively in angular velocity. 5. Angle of right wrist appeared that the speed of shuttle cock is decelerated because fast bends of wrist is not formed shortly after Impact because all subject do not accomplish big angle shortly after back swing. Angular velocity can assume that the subject S1 and S4 are using and move fast strong snap shot offering angular velocity value of Impact stage sound (-). 6. While size of Impact stage knee angle accomplishes angle that is big both subject, hip joint angles sees small angle and is playing swing that do on upper body and arm without using strong waist force that is composition action with knee and hip joint.

Development of Preliminary Quality Assurance Software for $GafChromic^{(R)}$ EBT2 Film Dosimetry ($GafChromic^{(R)}$ EBT2 Film Dosimetry를 위한 품질 관리용 초기 프로그램 개발)

  • Park, Ji-Yeon;Lee, Jeong-Woo;Choi, Kyoung-Sik;Hong, Semie;Park, Byung-Moon;Bae, Yong-Ki;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.113-119
    • /
    • 2010
  • Software for GafChromic EBT2 film dosimetry was developed in this study. The software provides film calibration functions based on color channels, which are categorized depending on the colors red, green, blue, and gray. Evaluations of the correction effects for light scattering of a flat-bed scanner and thickness differences of the active layer are available. Dosimetric results from EBT2 films can be compared with those from the treatment planning system ECLIPSE or the two-dimensional ionization chamber array MatriXX. Dose verification using EBT2 films is implemented by carrying out the following procedures: file import, noise filtering, background correction and active layer correction, dose calculation, and evaluation. The relative and absolute background corrections are selectively applied. The calibration results and fitting equation for the sensitometric curve are exported to files. After two different types of dose matrixes are aligned through the interpolation of spatial pixel spacing, interactive translation, and rotation, profiles and isodose curves are compared. In addition, the gamma index and gamma histogram are analyzed according to the determined criteria of distance-to-agreement and dose difference. The performance evaluations were achieved by dose verification in the $60^{\circ}$-enhanced dynamic wedged field and intensity-modulated (IM) beams for prostate cancer. All pass ratios for the two types of tests showed more than 99% in the evaluation, and a gamma histogram with 3 mm and 3% criteria was used. The software was developed for use in routine periodic quality assurance and complex IM beam verification. It can also be used as a dedicated radiochromic film software tool for analyzing dose distribution.

High-resolution Spiral-scan Imaging at 3 Tesla MRI (3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상)

  • Kim, P.K.;Lim, J.W.;Kang, S.W.;Cho, S.H.;Jeon, S.Y.;Lim, H.J.;Park, H.C.;Oh, S.J.;Lee, H.K.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.108-116
    • /
    • 2006
  • Purpose : High-resolution spiral-scan imaging is performed at 3 Tesla MRI system. Since the gradient waveforms for the spiral-scan imaging have lower slopes than those for the Echo Planar Imaging (EPI), they can be implemented with the gradient systems having lower slew rates. The spiral-scan imaging also involves less eddy currents due to the smooth gradient waveforms. The spiral-scan imaging method does not suffer from high specific absorption rate (SAR), which is one of the main obstacles in high field imaging for rf echo-based fast imaging methods such as fast spin echo techniques. Thus, the spiral-scan imaging has a great potential for the high-speed imaging in high magnetic fields. In this paper, we presented various high-resolution images obtained by the spiral-scan methods at 3T MRI system for various applications. Materials and Methods : High-resolution spiral-scan imaging technique is implemented at 3T whole body MRI system. An efficient and fast higher-order shimming technique is developed to reduce the inhomogeneity, and the single-shot and interleaved spiral-scan imaging methods are developed. Spin-echo and gradient-echo based spiral-scan imaging methods are implemented, and image contrast and signal-tonoise ratio are controlled by the echo time, repetition time, and the rf flip angles. Results : Spiral-scan images having various resolutions are obtained at 3T MRI system. Since the absolute magnitude of the inhomogeneity is increasing in higher magnetic fields, higher order shimming to reduce the inhomogeneity becomes more important. A fast shimming technique in which axial, sagittal, and coronal sectional inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the inhomogeneity map is applied. For phantom and invivo head imaging, image matrix size of about $100{\times}100$ is obtained by a single-shot spiral-scan imaging, and a matrix size of $256{\times}256$ is obtained by the interleaved spiral-scan imaging with the number of interleaves of from 6 to 12. Conclusion : High field imaging becomes increasingly important due to the improved signal-to-noise ratio, larger spectral separation, and the higher BOLD-based contrast. The increasing SAR is, however, a limiting factor in high field imaging. Since the spiral-scan imaging has a very low SAR, and lower hardware requirements for the implementation of the technique compared to EPI, it is suitable for a rapid imaging in high fields. In this paper, the spiral-scan imaging with various resolutions from $100{\times}100$ to $256{\times}256$ by controlling the number of interleaves are developed for the high-speed imaging in high magnetic fields.

  • PDF