• Title/Summary/Keyword: 회전기구

Search Result 270, Processing Time 0.025 seconds

Proposition of Korean Type Powered Wheelchair Seat Standards According to Age of the Human Scale (연령별 인체 치수에 따른 한국형 전동휠체어 좌석 표준규격 제언)

  • Kim, S.E.;Song, B.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.3
    • /
    • pp.237-243
    • /
    • 2015
  • As one of the most widely used assistive technology devices for the disabled in Korea, the powered wheelchair conforms to KS P ISO 7176-5 standard size which uses original version of international standard, ISO 7176-5 without technological modification. However, the international standard is not suitable for the disabled in Korea because it defines the size of wheelchair based on the body size of foreigners, which causes imbalanced posture due to limitation of movement or rotation of pelvis, pressure ulcer incidence due to excessive pressure on the thigh or popliteal space and calf, and safety of reduction due to improper posture. This study suggested the guidance of size for powered wheelchair based on human body size examined by Korean Agency for Technology and Standards, showing a great difference from the size defined in KS P ISO 7176-5 and accordingly redefinition for the size of powered wheelchair is needed.

  • PDF

A Study on the dose distribution and the accuracy of the system for small fields of high energy x-rays (고에너지 X-선 소조사야의 선량분포 및 계측에 관한 연구)

  • 이호남;지광수;김재휴;지영훈
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.32-44
    • /
    • 1995
  • I. 제 목 고에너지 X-선 소조사야의 선량분포 및 계측에 관한 연구 II. 연구의 목적 및 중요성 최근 수술이 어려운 뇌종양등에 대한 방사선수술법(Radiosurgery)이 관심의 대상이 되고 있다. 방사선수술법은 크게 나누어 200여개의 Co-60이 장착된 장치(Gamma Knife)를 이용하는 방법과, X-선치료기를 이용하는 방법은 몇개의 보조기구를 설치하면 가능한 매우 경제적인 방법이다. 따라서 Microtron을 이용한 방사선수술의 기초자료확보를 위하여 소조사야에 대한 선량과 선량분포의 측정 및 계산을 실시하였다. III. 연구의 내용 및 범위 Microtron으로부터 조사되는 6MV, 10MV, 21MV X-선의 지름 3cm이하 소조사야에 대한 정확한 선량 및 선량분포 자료를 확보하기 위해, 가. Microtron치료기와 보조장치등에 대한 정밀도 계측 및 평가 나. 보조 Collimator의 적당한 크기와 재료의 선택 및 설계, 제작. 다. 에너지와 조사야 크기 각각에 대한 여러측정장치(Ion chamber, Diode detector, TLD 및 Film등)를 이용한 선량 및 선량분포 측정. 라. 측정값들의 비교, 검토 및 측정된 자료에 의한 선량 및 선량분포의 계산을 수행했다. IV. 연구결과 및 활용에 대한 건의 본 연구에서 얻은 결과는 다음과 같다. 가. Microtron치료기와 보조장치등의 정확도의 허용 오차범위내에서 잘 일치하였다. 나. 보조 collimater adpator는 총 길이 24cm로 하였으며 재질로는 두랄미늄을 사용하였고, 보조 collimator는 low melting alloy를 사용하였으며 소조사야 크기의 정확도는 0.5mm이내에서 매우 잘 일치 하였다. 다. 방사선 수술법의 에너지 선택에 중요한 요소중의 하나인 penumbra는 6MV X-선에서 가장 적게 나타났으며 라. 소조사면에 대한 깊이-선량 백분율곡선은 모든 에너지에서 조사면이 작아질수록 표면으로 이동하는 경향을 보였다. 이상의 결과로부터 방사선 수술을 시행할 경우 수십억원에 이르는 장비의 도입이나 새로운 시설 없이 Microtron에서 조사되는 고에너지 X-선을 이용할 수 있을 것으로 사료된다. 또한 새로 구입한 측정기나 보조 Collimator를 이용하여 소조사야에 대한 선량측정기술을 습득함으로써 일반적인 소조사야의 방사선치료나 회전치료등에 활용할 수 있다.

  • PDF

The Emotional Sensibility Estimation System for Front-load Washer (드럼세탁기의 감성품질 측정 시스템)

  • Suh, Sang-Won;Lee, Chang-Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.821-826
    • /
    • 2010
  • The door-lock switch is one of the most important part in the front-load washer. As an safety system, it keeps the door locked while the front-load washer or the dish washer is working and generating heat and spin. The door of front-load washer needs the emotionality as well as the safety because the consumers always get feels when using it. In this paper, We study about emotional factors in the door of front-load washer and analyze the difference of emotionality as the structure of the door-lock switch changed. For this, we analyze the force graph by using the software and the jig which can measure the force while the door is opened or closed.

The Effects of Sling and Resistance Exercises on Muscle Activity and Pelvic Rotation Angle During Active Straight Leg Raises and Pain in Patients with Chronic Low Back Pain (만성 허리통증 환자에게 슬링과 기구저항운동이 통증과 능동 뻗은발올림 동안 근활성도, 골반 회전각에 미치는 영향)

  • Kim, Dae-Hyun;Kim, Tae-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.4
    • /
    • pp.113-121
    • /
    • 2018
  • PURPOSE: This study was conducted to identify a more effective intervention in sling and resistance exercise for chronic low back pain patients. METHODS: Seventy (70) subjects were randomly divided into the sling group (SG) and resistance exercise group (REG). Muscular activity of the internal oblique (IO), external oblique (EO), rectus abdominis (RA), and pelvic rotation angle during active straight leg raise (ASLR), a pressure pain threshold (PPT) and a visual analog scale (VAS) were measured. Sling and resistance exercises were conducted for 12 weeks. Intermediate measurements were taken after 8 weeks and final measurements were taken after 12 weeks. RESULTS: Both groups showed significantly decreased RA muscle activity and significantly increased IO muscle activity (p<.05). Additionally, EO muscle activity was significantly decreased in the REG, but significantly increased in the SG (p<.05), while the pelvic rotation angle and VAS were significantly decreased in the SG (p<.05). The pressure pain threshold was significantly increased in both groups (p<.05). CONCLUSION: Based on the results of this study, a 12-week intervention seems to be effective at improving back pain in both groups. However, a lower VAS was seen in the sling group after 8 weeks of intervention. Therefore, it is recommended that the sling be applied first when establishing a chronic back pain treatment program to shorten the treatment period and reduce the pain period.

Real-time Highly Sensitive Measurement of Myocardial Infarction Biomarkers Using Silicon-based Ellipsometric Biosensors (실리콘 기반 타원편광계식 바이오센서를 이용한 심근경색 생체표지자의 실시간 초고감도 진단 농도 측정)

  • Min, Yoon Gi;Cho, Hyun Mo;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.2
    • /
    • pp.59-66
    • /
    • 2019
  • We report highly sensitive detection of myocardial infarction biomarkers, such as myoglobin and cTnI, within several hundred seconds using a rotating-analyzer ellipsometer and a biosensor with biochips fabricated on a $SiO_2$-coated tilted silicon substrate. We choose the running buffer to be pure phosphate-buffered saline (PBS) or 10% mixed human serum. When we choose the running buffer to be pure PBS, we obtain diagnostic densities of pure myocardial infarction biomarkers of up to 1 ng/ml and 5 pg/ml respectively. Meanwhile, when we use PBS with 10% human serum, the measured densities of myoglobin and cTnI were up to 1 ng/mL and 1 pg/mL respectively. The measured diagnostic densities are less than 1/15 and 1/80 (in cases of myoglobin and cTnI respectively) of those referenced by the World Health Organization.

Kinematic Design of High-Efficient Rotational Triboelectric Nanogenerator (고효율 회전형 정전 나노 발전기의 기구학적 설계)

  • Jihyun Lee;Seongmin Na;Dukhyun Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.1
    • /
    • pp.106-111
    • /
    • 2024
  • A triboelectric nanogenerator is a promising energy harvester operated by the combined mechanism of electrostatic induction and contact electrification. It has attracting attention as eco-friendly and sustainable energy generators by harvesting wasting mechanical energies. However, the power generated in the natural environment is accompanied by low frequencies, so that the output power under such input conditions is normally insufficient amount for a variety of industrial applications. In this study, we introduce a non-contact rotational triboelectric nanogenerator using pedaling and gear systems (called by P-TENG), which has a mechanism that produces high power by using rack gear and pinion gear when a large force by a pedal is given. We design the system can rotate the shaft to which the rotor is connected through the conversion of vertical motion to rotational motion between the rack gear and the pinion gear. Furthermore, the system controls the one directional rotation due to the engagement rotation of the two pinion gears and the one-way needle roller bearing. The TENG with a 2 mm gap between the rotor and the stator produces about the power of 200 ㎼ and turns on 82 LEDs under the condition of 800 rpm. We expect that P-TENG can be used in a variety of applications such as operating portable electronics or sterilizing contaminated water.

Evaluation of canal preparation for apical sealing with various Ni-Ti rotary instruments (수 종의 Ni-Ti 회전 기구들을 이용한 치근단 폐쇄 향상을 위한 근관 확대 평가)

  • Shin, Yoo-Seok;Shin, Su-Jung;Song, Min-Ju;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.300-305
    • /
    • 2011
  • Objectives: The aim of this study was to evaluate the various NiTi rotary instruments regarding their ability to provide a circular apical preparation. Materials and Methods: 50 single canal roots were selected, cut at the cementodentinal junction and the coronal 1/3 of the canals was flared using Gates Glidden burs. Samples were randomly divided into 5 experimental groups of 10 each. In group I, GT files, Profile 04 and Quantec #9 and #10 files were used. In Group II Lightspeed was used instead of Quantec. In Group III, Orifice shaper, Profile .06 series and Lightspeed were used. In Group IV, Quantec #9 and #10 files were used instead of Lightspeed. In Group V, the GT file and the Profile .04 series were used to prepare the entire canal length. All tooth samples were cut at 1 mm, 3 mm and 5 mm from the apex and were examined under the microscope. Results: Groups II and III (Lightspeed) showed a more circular preparation in the apical 1mm samples than the groups that used Quantec (Group I & IV) or GT files and Profile .04 series.(Group V)(p < 0.05) There was no significant difference statistically among the apical 3, 5 mm samples. In 5 mm samples, most of the samples showed complete circularity and none of them showed irregular shape. Conclusions: Lightspeed showed circular preparation at apical 1 mm more frequently than other instruments used in this study. However only 35% of samples showed circularity even in the Lightspeed Group which were enlarged 3 ISO size from the initial apical binding file (IAF) size. So it must be considered that enlarging 3 ISO size isn't enough to make round preparation.

The Benefit of KT-2000 Knee Ligament Arthrometer in Diagnosis of Anterior Cruciate Ligament Injury (슬관절 전방 십자 인대 파열의 진단에 있어서 KT-2000 기기의 유용성)

  • Park, Jai-Hyung;Kim, Hyoung-Soo;Jung, Kwang-Gyu;Yoo, Jeong-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.82-88
    • /
    • 2004
  • Purpose: In this study, we intended to ascertain the benefit of KT-2000 Knee arthrometer(KT-2000) in the diagnosis of ACL(Anterior cruciate ligament) injury by comparing the anterior displacement of normal knee with that of ACL deficient knee. Materials and Methods: We designated two examiners to measure the anterior displacement of the knee joint of 30 healthy individuals, using KT-2000, at 30$^{\circ}$ flexion setting of muscle full relaxation, contraction, 25$^{\circ}$ internal rotation and 25$^{\circ}$ external rotation and analyzed these results according to the variables and measured the preoperative anterior displacement of the ACL injured knee in the 30 patients who have gone through an arthroscopic ACL reconstruction later. Results: The results of examiner 1 are 6.5${\pm}$1.5 mm, 2.5${\pm}$0.9 mm, 4.8${\pm}$1.2 mm, 6.4${\pm}$1.3 mm in right knee and 5.6${\pm}$1.3 mm, 2.1${\pm}$0.8 mm, 4.5${\pm}$1.2 mm, 5.2${\pm}$1.3 mm in left knee, in order of muscle full relaxation, contraction, 25$^{\circ}$ internal rotation and 25$^{\circ}$ external rotation. The results of examiner 2 are 6.9${\pm}$1.2mm, 2.9${\pm}$1.1mm, 5.6${\pm}$1.6mm, 6.9${\pm}$1.5mm in right, 5.5${\pm}$1.7 mm,1.9${\pm}$0.9 mm, 5.1${\pm}$1.9 mm, 5.7${\pm}$1.6 mm in left knee, The side to side difference of examiner 1 in the setting of muscle relaxation is 0.9${\pm}$1.0 mm. The anterior displaement of ACL injured knee is average 11${\pm}$2.93 mm and difference of average 6.5${\pm}$2.31 mm form that of normal. In comparison between the right and left knees of healthy individuals, the both results of two examiners showed the statistical difference in the setting of muscle full relaxation but, the results showed the side to side difference below 2 mm in 25case(83%), 21case(70%) respectively and above 3 mm in just 1 case. In the comparison between the normal and ACL injured knees, the results show the statistical difference of the side to side difference in the setting of muscle relaxation(p<0.05). Conclusion: The KT-2000 result is affected by relaxation of muscles around knee, flexion angle of knee joint, rotation of tibia, the strength of displacing force, time of the test and physical factors as height and weight. However, the Accuracy of diagnosis of ACL injury by KT-2000 will increase if the examiner is skillful and the tests are made on the exact position of knee joint.

  • PDF

A Study on the Standards of South Korea Type Manual Wheelchair in Accordance with the Human Body Size of Adult (성인인체치수에 따른 한국형수동휠체어 표준규격에 관한 고찰)

  • Kim, S.E.;Song, B.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.63-68
    • /
    • 2013
  • Manual wheelchair is one of the most used assistant device in Korea and the size of the wheelchair is defined as KS P ISO 7176-5 which follows the ISO 7176-5 standard size. But the standard often doesn't fit to Korean people because the ISO was enacted by foreigners' body sizes. Actually the result of survey from the Korean Agency for Technology and Standards showd that the designated sizes of height, width, deep of seat except armrest and the height of backrest of a chair in the present KS P ISO 7176-5 are much bigger and the height of armrest is smaller than the sizes investigated by the survey. In case the disabled person has a long wheelchair use time everyday, the posture of user should be uncomfortable because the mismatched size should cause user's pelvis rotations, slouching pose and low stability. Also, inside of knee may touch the wheelchair seat and user can't keep a correct posture. In this paper, the body sizes of Korean disabled person were investigated and the correct wheelchair sizes for Korean people are provided.

  • PDF

Analysis of traction and power requirement for forage harvester (조사료 수확기의 견인력 및 소요동력 분석)

  • Hong, Seongha;Kang, Daein;Cho, Yongjin;Lee, Kyouseung
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.80-80
    • /
    • 2017
  • 국내에서 대부분 생산되는 사료(사일리지) 수확 작업은 베일 생산 및 비닐 래핑 작업이 독립적으로 수행되고 있어서 비효율적이다. 본 연구에서 개발한 조사료 수확기는 수집, 롤링, 베일 네트 생성, 래핑, 래핑 종료 및 베일 방출작업을 통합적으로 수행하도록 설계-제작하였다. 통합형 다목적 조사료수확기의 설계는 3D 디자인 툴 (CATIA V5R18)을 이용하여 실시하였으며, 기구부 23 파트 어셈블리, 전기제어 어셈블리, 유압요소기술을 통합하여 통합시작기를 제작하였다. 기초 프레임, 오거장치파트, 픽업장치파트, 하부롤러파트, 상부롤러파트, 하부 프레임 및 주행부 파트, 래핑회전파트, 롤러부 구동 동력부, 유압파트, 전기제어파트, 드로우바파트, 체결 및 컨트롤러 파트 등 25개 파트로 구성되어 있다. 본 연구에서 개발한 시작기의 견인력 및 소요동력 분석은 선행 연구에서 사용한 Brixius (1987) 제안 모델을 체택하여 분석하였다. 이 Brixius 제안 모델은 견인력 예측에서 토양변수 및 토양강도 특성을 나타내는 원추지수 (Cone Index, CI)를 이용하여 트랙터의 견인력 예측에 사용하였다. 또한 트랙터-조사료수확기 시스템의 소요 견인력을 예측하는데 있어, 트랙터-조사료수확기 시스템이 운용되는 토양조건과 트랙터의 마력에 따른 소요 견인력 특성을 분석하기 위해 대표적으로 3수준의 토양조건 (CI: 356 kPa, 543 kPa, 1,429 kPa)을 적용하였으며, 베일의 개당 최대무게는 최고 수준인 옥수수 기준으로 800 kgf를 적용하였다. 본 연구에서 적용된 3수준의 CI 조건은 연구팀에서 선행연구과정 (토양특성에 따른 최적 경운작업 시스템 개발, 2006)에서 분석한 전국 10개 지역의 33개 지점의 경반층 CI지수의 측정범위인 1,050-3,170 kPa에 대해 견인력이 많이 소요되는 열악한 조건 수준을 적용하였다. 각 작업에 사용된 소요동력은 베일 작업시 (ASABE D497.7, 2011) 그리고 래핑작업시 (Zhortuylov et al., 2013)를 사용하였으며 두 소요마력을 트랙터-조사료 수확기 시스템의 필요 소요마력의 합계로 계산하였다. 트랙터-조사료수확기 시스템의 최소 소요 동력, 차축 소요 동력과 PTO 소요 동력을 Zoz and Grisso (2003)을 이용하여 계산하였다. 연구에서는 기본적으로 ASAE의 작업속도 및 작업효율을 적용하였는데, 적용된 조사료수확기의 현장 작업효율은 60-86%의 범위이고 일반적으로 70%를 적용하고 이때 작업속도는 2.5-8.0 km/h이며 전형적으로 5.0 km/h를 기준하고 있다. 자주식 (SP; sief-propelled machine) 조사료수확기의 경우 작업속도가 2.5-10.0 km/h의 범위에서 작업효율은 60-85% 범위이다. 적용되는 조사료 수확기의 작업효율인 60-85% 범위에서 일반적으로 적용되는 작업효율인 70%를 적용하면 트랙터의 소요동력은 95hp를 적정 작업환경으로 하였다.

  • PDF