• Title/Summary/Keyword: 환자 피폭선량

Search Result 446, Processing Time 0.031 seconds

Assessment of Entrance Surface Dose and Image Distortion in Accordance with Abdominal Obesity in the Chest Radiography (흉부 X-선 검사에서 복부비만에 따른 입사표면선량과 영상 왜곡도 평가)

  • Kim, Boo Soon;Park, Jeong Kyu;Kwon, Soon Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.473-478
    • /
    • 2015
  • Abdominal obesity is one of the most influential index to predict of insulin resistance syndrome/metabolic syndrome in social demographic characteristics. It is matter of fact that radiation dose are increasing with development of medical treatment and device. In this study, we estimated distortion between reference image and entrance surface dose when take a chest radiography forward chest phantom assumed abdominal obesity. When angle of chest phantom incline $5^{\circ}$ forward, thoracic transverse and longitudinal diameter increase 1.22% and 0.44% each. Also cardiac transverse diameter increase 1.01% and cardio-throracic ratio (CTR) decrease 0.27% in the same situation of incline to $5^{\circ}$ forward. Thoracic transverse diameter shows the largest increase, and CTR was decreased. But entrance surface dose to phantom increase significantly 6.12% when angle of chest phantom incline $5^{\circ}$ forward. In conclusion, we have to pay attention to accurate positioning, to prevent a distortion of image through incline, and make patients not to expose to additional radiation.

A Comparison Analysis of CT Effective Dose and Image Quality according to Abdominal Diameter (복부직경에 따른 CT유효선량 및 화질변화 비교 분석)

  • Yoon, Joon;Kim, Hyeonju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.821-826
    • /
    • 2018
  • This study was performed randomly from all the patients who visited the University Hospital in Gyeonggi-do from January 1, 2018 to June 30, 2018 for the abdominal CT scan. We divided the patients into three groups and evaluated the extent of effective dose and image quality according to the area of the abdominal CT image. As a result, the effective dose was 7.34 mSv in the average area group, 8.39 mSv in the average area and 5.89 mSv in the average area. For the analysis of image quality, ROI was plotted in the same three regions according to the abdominal area. As a result, CT values were significantly different in the abdominal area classified into 3 groups (p <0.05). The results of this study can be used as a basic data for the development of a protocol that can be applied in actual clinical practice. It is thought that it can help to reduce the image quality and the radiation dose.

VCUG Studies on the Clinical Usefulness of Aids (VCUG 보조기구의 임상적 유용성에 관한 고찰)

  • Choe, Dea yeon;Kim, Dong hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.529-533
    • /
    • 2015
  • VCUG(Voiding Cystourethrography) study is being performed to check urinary reflex symptom from bladder to ureter or kidney in the method of filling the bladder with radiation opaque contrast agent. However, VCUG study have been performed impersonally, patients have to be naked and open their legs and then void. This method is so impersonal that it is immediately needed to improve the way of testing and crete new aid. Therefore, this study through producing underwear for VCUG, analysis and compares the test time of VCUG, patient radiation dose and patient satisfaction. The target of this study was 79 Male and Female patients who visited genitourinary clinic of PNUYH for their VCUG tests AXIUM Iconos R200(Siemens Medical System : Germany) and self-produced plastic underwears made by vinyl and plasic molding machine were used. The 79 patient were divided into two groups : experiment of patient and comparison group of we patient (using aid) in order to compare, testing time, DAP (dose area product) and patient satisfaction. There was time reduction, from 35.3min of comparison group to 27.8min experimentation group by 7.5min decrease. And comparison group of $4566.6{\mu}Gym^2$(DAP) decreased experimental group (using aid) of $3411.9{\mu}Gym^2$ by $1154.7{\mu}Gym^2$. In the case of patients satisfaction study, anxiety had a drop by 3.45 of comparison group to 2.51 experimentation group by 0.94 decrease. in experimental group. And shame had a drop by 4.02 of comparison group to 3.08 experimentation group by 0.94 increase. in experimental group. Difference of the smooth voiding had a drop by 1.90 of comparison group to 2.84 experimentation group by 0.94 increase. in experimental group. In addition satisfaction had a rise by 1.19 in experimental group. There were also other opinions of uncomfortableness on it and troublesome to wear. VCUG is one of the sensitive care required test. Therefore staff and the aid can give patients such comfortable and the aid can consentive on voiding. As a result test time and DAP can be reduced. It is needed to make testing at more comfortable for patients.

Assessment of DRL for Computed Tomography in Local Hospital (지역병원에서의 전산화단층촬영 검사에 대한 DRL 평가)

  • Choi, Seok-Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.619-625
    • /
    • 2022
  • In the field of imaging medicine, computed tomography is one of the most common test methods and one of the most frequently used test methods in hospitals. However, it is accompanied by a very high radiation exposure compared to other test methods. In order to reduce exposure, CT scans should be performed only when absolutely necessary, and even if the tests are performed because they are absolutely necessary, a protocol that serves the purpose of the test and allows the test to be performed in a small dose should be used. In this study, we wanted to learn about the most up-to-date radiation dose usage information used by the region's leading general hospitals and develop a diagnostic reference level (DRL). In the experimental results, the Head CT and Abdomen CT tests showed that DLP was higher than the NRPB (U.K) and Korean DRL. The DLP values used by Chest CT were low for all 3 types of CT devices. The hospital found that efforts to reduce exposure should be made during CT examinations, and in particular, Head CT and Abdomen CT determined that efforts to reduce exposure were necessary.

Effects of Single Vessel PCI (Percutaneous Coronary Intervention) using DCR (Dynamic Coronary Road map) on Fluoroscopy Time and Patient Radiation (동적 심혈관 로드맵을 이용한 중재적 시술이 투시 시간 및 환자 피폭에 미치는 영향)

  • Jong-Gil Kwak;Young-Hyun Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.551-556
    • /
    • 2023
  • Angiography equipment is used to evaluate and treat coronary artery disease. As a common feature of equipment, radiation is used, and function development for dose reduction is being carried out by each company. Therefore, the difference depending on whether DCR installed in angiography equipment is used is analyzed from a radiological point of view to prove the effect. Among 431 patients who underwent coronary artery intervention from March 2021 to February 2023, 250 patients with retrospective data were selected. And than among the 250 subjects obtained, 91 patients used the cardiovascular roadmap function during single-vessel intervention, and 159 patients did not use the roadmap. When DCR was used, total dose area product (34.57 uGy/m2 : 69.15 uGy/m2), total air kerma dose (688.47 mGy : 1640.4 mGy), fluoroscopy dose (23.87 uGy/m2 : 49.91 uGy/m2) and fluoroscopy time (723.55 s : 366.03 s), total number of images (17 : 26) showed lower values and were statistically significant than those not used. The use of DCR function in single vessel coronary intervention is thought to be radiologically safer as single vessel coronary intervention using dynamic cardiovascular DCR showed lower perspective time and perspective dose than procedures performed without the DCR.

Usability of Digital Tomosynthesis in Mammography (유방 촬영에서 디지털 토모신테시스(Digital Tomosynthesis)의 유용성)

  • Lee, Mi-Hwa;Jung, Hong-Rayng
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.151-152
    • /
    • 2015
  • 유방 검사에서 Tomosynthesis는 Mammogram과 비교하여 유방 병변 구별에 우수하고 확연한 대조도 차이를 보이며 추가적인 유방촬영 검사나 재촬영을 감소시킴으로서 장기적으로 환자의 피폭선량이 감소하는 효과를 보이므로 유방 병변 진단의 효과를 높일 수 있는 유용한 검사이다.

  • PDF

Evaluation of Effective and Organ Dose Using PCXMC Program in DUKE Phantom and Added Filter for Computed Radiography System (CR 환경에서의 흉부촬영 시 Duke Phantom과 부가여과를 이용한 유효선량 및 장기선량 평가)

  • Kang, Byung-Sam;Park, Min-Joo;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • By using a Chest Phantom(DUKE Phantom) focusing on dose reduction of diagnostic radiation field with the most use of artificial radiation, and attempt to reduce radiation dose studies technical radiation. Publisher of the main user of the X-ray Radiological technologists, Examine the effect of reducing the radiation dose to apply additional filtering of the X-ray generator. In order to understand the organ dose and effective dose by using the PC-Based Monte Carlo Program(PCXMC) Program, the patient receives, was carried out this research. In this experiment, by applying a complex filter using a copper and Al(aluminum,13) and filtered single of using only aluminum with the condition set, and measures the number of the disk of copper indicated by DUKE Phantom. The combination of the composite filtration and filtration of a single number of the disk of the copper is the same, with the PCXMC 2.0. Program looking combination of additional filtration fewest absorbed dose was calculated effective dose and organ dose. Although depends on the use mAs, The 80 kVp AP projection conditions, it is possible to reduce the effective amount of about 84 % from about 30 % to a maximum at least. The 120 kVp PA projection conditions, it is possible to reduce the effective amount of about 71 % from about 41 % to a maximum of at least. The organ dose, dose reduction rate was different in each organ, but it showed a decrease of dose rate of 30 % to up 100 % at least. Additional filtration was used on the imaging conditions throughout the study. There was no change in terms of video quality at low doses. It was found that using the DUKE Phantom and PCXMC 2.0 Program were suitable to calculate the effect of reducing the effective dose and organ dose.

Reduction of Radiation Dose for Injection of Radioisotope using Shielding Device (방사성동위원소 투여 시 차폐기구를 이용한 방사선 피폭 저감)

  • Lim, Jong-Nam;Kim, Hyung-Tae;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.291-296
    • /
    • 2019
  • Nuclear medicine have often used to diagnose cancers. The main absorbed dose from radiation to a radiation worker resulted from open radioisotopes. Methods for reducing the radiation dose to a radiation worker from radioisotopes injected to patients were studied. The shield device of 0.2 mmPb was manufactured as a size of $300mm{\times}500mm{\times}150mm$. By using dosimeters of Nanodot, the absorbed doses for thyroid, chest and genital organ were measured with and without a shielding device and with syringe shield and shielding device together. The highest absorbed dose of 0.908 mGy reduction of 20.8% as 0.719 mGy was in the genital organ by using the syringe shield and a shielding device together. A effective dose for a radiation worker during 1 year was expected to 1.223 mSv at the chest, which was decrease as 0.994 mSv by shielding device and syringe shield together. When open radioisotope is injected to a patient for examination, the only use of a shielding device results in the reduction of radiation dose to radiation workers.

Evaluation of Breast Dose in Mammography for Breast Implant Patient using a Monte Carlo Simulation (몬테칼로 모의모사를 이용한 유방성형술 환자의 유방선량평가)

  • Kim, Ji-Soo;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.253-259
    • /
    • 2020
  • Mammography has the advantage of being economical, simple and effective in detecting microcalcification, but breast is a highly sensitive organ and is accompanied by the risk of an over-exposure. While accurate dose assessments are important to prevent this, current breast dose assessments are limited to breast implant patients. This purpose of this study was to identify dose variations due to tube voltages by forming a mock-up with breast implants for an accurate dosimetric assessment on breast implant patients. As a result, doses from the presence of breast implants were smaller than those from the absence of the mammal. As the result of the change of the voltage to 26, 28, 30, and 32 kV, the imcreased tube voltage included larger dose regardless of the presence of Breast implant. Therefore, it is believed that diagnosis recommendations for breast implants will be possible if further studies on internal and external bioretical imaging and quality assessment are carried out as the basis for this study.