• Title/Summary/Keyword: 환자 자세

Search Result 643, Processing Time 0.028 seconds

Autologous Transfusion in Pregnant Women with Significant Risk for Hemorrhage (출혈위험 임산부에서의 자가수혈)

  • Kim, Gee-Deuk;Bae, Chul-Sung;Park, Yoon-Kee;Kim, Jong-Wook;Koh, Min-Whan;Lee, Sung-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.1
    • /
    • pp.95-103
    • /
    • 1990
  • Autologous transfusion, storage of one's own blood for subsequent infusion if needed, is safe and effective in a variety of scheduled operative procedures. Obstetric involvement in such programs is very limited, however, because of concern over the possibility of inducing premature labor or causing fetal distress by blood volume change or vasovagal reactions. We describe our experience with pregnant women in this program. The incidence of vagovagal reactions of autologous donation was 9.5% (2/21). After entry into this program, 17pastients received a total 37pints, which consist of 19 Autologous and 18 Homologous. Homologous transfusion was avoided in 30% of patients receiving blood. The values of the mean haematocrits before and after hpebotomy were 34.1 % and 31.8 % respectively. It was statically significant(p<0.01). We recommended that autologous blood donation by pregnant women in third trimester is safe for mothers or infants and it should be strongly encouraged for patient with placenta previa and repeated cesarean section.

  • PDF

Guidelines and Status of Hospital Library in Korea: for Patients and Carers (국내 병원도서관 관련 기준 및 현황)

  • Rhee, Hey Young
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.29 no.4
    • /
    • pp.179-202
    • /
    • 2018
  • This study examined and analyzed the related study, Library Law, comparison of Korean Library Standards and IFLA guidelines and the status of domestic hospital library provision in order to grasp the regulations and status of domestic hospital library. As a result, the related study is very insufficient compared to overseas, and the Law and Standards for hospital libraries are not clearly and in detail in the Library Law. It is impossible to grasp the statistics and actual condition of the hospital library through the Yearbook of the Korean Library. The Korean Library Standards and IFLA guidelines also show differences in composition and key elements. According to the survey, 49 hospitals (1.3%), 8 hospitals (0.2%), 5 nursing hospitals (0.1%), 4 children's hospitals (0.1%), and 1 military hospital (0.0%) were among the 67 hospitals surveyed. Of the 49 general hospitals, 42 were advanced general hospitals, of which 17 were providing hospital libraries. The most urgent issue for providing hospital libraries is the revision of the Library Law and the Korean Library Standards, and the mandatory provision of hospital libraries, publicity through library magazines, and related research should be carried out.

Comparison of X-ray Image Quality Between Multi-Function Device(MFD) and Weight Bearing Platforms(WBPs) (다기능 보조기구와 체중부하검사 보조기구의 X선 화질 비교)

  • Gil, Jong-Won;Lee, Kwang-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.605-611
    • /
    • 2019
  • The purpose of this study is to manufacture a multi-function device (MFD) which can be applied to various types of weight-bearing view of the lower leg, and to compare the results with the images from the existing weight-bearing platforms (WBPs), thereby suggesting a clinical utilization. The MFD was manufactured, by considering the minimum adjustable heights of the platform for weight-bearing foot/ankle, platform for hindfoot alignment view, and X-ray tube of the X-ray device. A foot/ankle phantom was used to take the images of weight-bearing lateral foot in MFD and WBPs to compare the resolutions of the X-ray images using a quick modulation transfer function (MTF) program. Between both the images taken from the MFD and WBPs, there was no statistically significant difference found in the mean cycles per pixel (C/P) and the lines per image height (LPH) of the 50%-Contrast Spatial Frequency (MTF50), and 10-90% of Maximum Energy Rise Distance (10-90%), where p>0.05. The MFD is suggested for its clinical trial as a useful positioning device that can secure the patient's safety and manifoldly perform various inspections. Also, the recommendation of the positioning device as a policy can activate dedicated manufacturers, while also improving the quality of medical services.

A Case of Korean Medical Treatment on Parkinson's Disease Patient with Postural Instability, Presenting as Camptocormia (몸통굽힘증을 주소로 하는 파킨슨병 환자의 자세 이상에 대한 한의 치료 증례 1례)

  • Kim, Ha-ri;Jeong, Hye-seon;Shin, Hee-yeon;Choi, Jeong-woo;Yang, Seung-bo;Cho, Seung-yeon;Park, Jung-mi;Ko, Chang-nam;Park, Seong-uk
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.2
    • /
    • pp.220-227
    • /
    • 2019
  • Objectives: Parkinson's disease is the neurodegenerative disease that affects both motor and non-motor function, including postural instability. Camptocormia is an abnormal condition in which the thoracolumbar spine bends forward during walking or standing. However, the treatment options are limited and often not effective. The purpose of this study was to report on the Korean medical treatment of a Parkinson's disease patient with postural instability who presented with camptocormia. Methods: We used Korean medical treatment including herbal medicine (Jemageopung-tang), acupuncture and pharmacopuncture therapy to the patient who was admitted to the hospital for 21 days. The clinical symptoms were assessed with the Unified Parkinson's Disease Rating Scale (UPDRS) and walking time without assistance. Results: After treatment, the UPDRS Parts 2 and 3 scores were decreased from 5 to 3 and 20 to 9, respectively. Also, the walking time without assistance was improved. Conclusion: This study suggested that Korean medical treatment could be an effective option for treating Parkinson's disease with postural instability.

Perception and Attitude on Augmented Reality Smart Glass for Healthcare Convergence Simulation (증강현실(AR) 스마트글라스 보건의료 융합 시뮬레이션에 대한 인식 및 태도)

  • Lee, Youngho;Choi, Jongmyung;Yoon, Hyoseok;Kim, Sun Kyung
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.1
    • /
    • pp.369-377
    • /
    • 2021
  • Augmented reality smart-glass enables healthcare providers to use patient and their care related information without interference of workflow. In addition, augmented reality smart-glass simulation had advantages in improving competency via remote collaboration and real-time information sharing. This study investigated perception and attitude regarding augmented reality smart glass based healthcare simulation on three different groups of healthcare major students, computer major students, developers and faculties. Using convenience sampling method, data were obtained from 95 participants and statistical analysis were performed using SPSS 25.0. Developer and faculty group showed the highest scores, followed by healthcare major students. There was the high expectation on augmented reality smart-glass for skill acquisition and the high performance and big screen were essential features of device. The findings of this study revealed that differences between healthcare and computer major students exist and strategies to reduce those gaps are required to adopt augmented reality smart glass in healthcare settings.

Factors influencing success and safety of AED retrieval in out of hospital cardiac arrests in Singapore

  • NG, Jonathan Shen You;HO, Reuben Jia Shun;YU, Jae Yong;NG, Yih Yng
    • The Korean Journal of Emergency Medical Services
    • /
    • v.26 no.2
    • /
    • pp.97-111
    • /
    • 2022
  • Purpose: Automated External Defibrillator (AED) usage in out-of-hospital cardiac arrests (OHCAs) improves the survival of patients. In Singapore, public AEDs are protected by locked boxes with a 'break glass' mechanism to deter theft. Community responders have sustained injuries while breaking glass to retrieve AEDs. This unprecedented study aimed to elucidate the factors influencing successful retrieval of an AED and to document the prevalence of injuries. Methods: A survey was created and distributed. Participants were required to have responded to an OHCA in the past 12 months. Comparison tests were performed with the Fischer-Freeman-Halton Exact test or Pearson chi square test at 5% significance levels, and with multiple logistic regression with a logit link function. Results: Eighty-eight participants were eligible. The success of retrieving an AED was found not to be impacted by occupation, age, gender or time. Participants who responded to an OHCA because of activation by the myResponder App were more likely to retrieve an AED successfully. (AOR 11.111, 95% CI: 2.141-58.824) Conclusion: Use of the myResponder mobile application is associated with the greater success of retrieving an AED. Successful retrieval of an AED is not impacted by time, gender, age, or the occupation of the responder. Community responders in Singapore remain motivated to respond to Cardiac Arrests despite risk of injury.

A Study on the Usefulness of an Ankle Joint Examination Assistive Device using a 3D Printing (3D 프린터를 이용한 발목관절 검사 보조기구의 유용성연구)

  • Dong-Hee Hong;Eun-hye Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1099-1108
    • /
    • 2023
  • The mortise view radiography procedure is an ankle joint examination and observes the presence of trauma, sprain, or dislocation suspected in the ankle joint. The auxiliary equipment used during the mortise view radiography procedure can generate artifacts in the radiograph images and is not diverse enough to be custom-made for each patient; not cost-efficient. The purpose of this study is to create a custom assistive device to support mortise view radiography procedure. This study utilized 3D printing technology to create the mortise view radiography procedure assistive device (ShinHan Device; SHD). The lengths of the tibiotalar joint (TTJ), talar calcaneal joint (TCJ), and medial joint (MJ) were measured and evaluated by five researchers using both SHD and the prototype Hologic tool. The mean ranges were found to be 39.42-39.47 mm for TTJ, 31.41-31.57 mm for TCJ, and 21.21-21.23 mm for MJ while using SHD device. On the other hand, the measurements showed mean ranges of 39.73-39.79 mm for TTJ, 31.46-31.50 mm for TCJ, and 21.31-21.35 mm for MJ while using the Hologic tool. Based on this study results, the error ranges at all positions decreased by 24% for TTJ, 17% for TCJ, and 36% for MJ when using SHD device compared to the Hologic tool. Moreover, when SHD was used, it allowed for a highly reproducible examination posture (ICC = 0.99), and it enabled the acquisition of radiograph images without artifacts, which were present in the Hologic tool.

Optimization of MRI Protocol for the Musculoskeletal System (근골격계 자기공명영상 프로토콜의 최적화)

  • Hong Seon Lee;Young Han Lee;Inha Jung;Ok Kyu Song;Sungjun Kim;Ho-Taek Song;Jin-Suck Suh
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.21-40
    • /
    • 2020
  • Magnetic resonance imaging (MRI) is an essential modality for the diagnosis of musculoskeletal system defects because of its higher soft-tissue contrast and spatial resolution. With the recent development of MRI-related technology, faster imaging and various image plane reconstructions are possible, enabling better assessment of three-dimensional musculoskeletal anatomy and lesions. Furthermore, the image quality, diagnostic accuracy, and acquisition time depend on the MRI protocol used. Moreover, the protocol affects the efficiency of the MRI scanner. Therefore, it is important for a radiologist to optimize the MRI protocol. In this review, we will provide guidance on patient positioning; selection of the radiofrequency coil, pulse sequences, and imaging planes; and control of MRI parameters to help optimize the MRI protocol for the six major joints of the musculoskeletal system.

Treating Idiopathic Parkinson's Disease with Bonoesikpungjigyeong-tang: A Case Study on "Delayed On" and "Wearing Off" Phenomena after Long-term Levodopa Intake (레보도파 약효 지연 현상 및 약효 감소 현상으로 인한 자세불안정 및 전신탈력감을 호소하는 특발성 파킨슨병 환자에 대한 보뇌식풍지경탕 치험 1례)

  • Siyun Sung;Dabin Lee;Seongeun Huh;Sunghee Hong;Ye-chae Hwang;Gyeongmuk Kim;Han-Gyul Lee;Sang-Kwan Moon;Woo-Sang Jung;Seungwon Kwon
    • The Journal of Internal Korean Medicine
    • /
    • v.45 no.2
    • /
    • pp.219-233
    • /
    • 2024
  • A 69-year-old female diagnosed with idiopathic Parkinson's disease and treated with anti-Parkinsonian medications, including levodopa, for 7 years presented with complaints of wearing-off phenomenon and delayed onset of medication efficacy, resulting in postural instability and feeling of severe exhaustion. The patient underwent a 50-day course of treatment with Bonoesikpungjigyeong-tang formula. The effects of the treatment were evaluated by recording the average time to onset of medication efficacy, the average time to medication wearing-off, and discomfort due to wearing-off phenomenon. Postural instability was assessed using the Numeric Rating Scale (NRS). The patient's overall quality of life was assessed using the EQ-5D-3L. After 50 days of treatment, the average time to onset of medication efficacy decreased, and the average time to medication wearing-off increased. Discomfort due to wearing-off phenomenon and postural instability decreased. This case suggests that Bonoesikpungjigyeong-tang might be an alternative for improving discomfort caused by long-term levodopa intake.

The Evaluation of Attenuation Difference and SUV According to Arm Position in Whole Body PET/CT (전신 PET/CT 검사에서 팔의 위치에 따른 감약 정도와 SUV 변화 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Purpose: For better PET imaging with accuracy the transmission scanning is inevitably required for attenuation correction. The attenuation is affected by condition of acquisition and patient position, consequently quantitative accuracy may be decreased in emission scan imaging. In this paper, the present study aims at providing the measurement for attenuation varying with the positions of the patient's arm in whole body PET/CT, further performing the comparative analysis over its SUV changes. Materials and Methods: NEMA 1994 PET phantom was filled with $^{18}F$-FDG and the concentration ratio of insert cylinder and background water fit to 4:1. Phantom images were acquired through emission scanning for 4min after conducting transmission scanning by using CT. In an attempt to acquire image at the state that the arm of the patient was positioned at the lower of ahead, image was acquired in away that two pieces of Teflon inserts were used additionally by fixing phantoms at both sides of phantom. The acquired imaged at a were reconstructed by applying the iterative reconstruction method (iteration: 2, subset: 28) as well as attenuation correction using the CT, and then VOI was drawn on each image plane so as to measure CT number and SUV and comparatively analyze axial uniformity (A.U=Standard deviation/Average SUV) of PET images. Results: It was found from the above phantom test that, when comparing two cases of whether Teflon insert was fixed or removed, the CT number of cylinder increased from -5.76 HU to 0 HU, while SUV decreased from 24.64 to 24.29 and A.U from 0.064 to 0.052. And the CT number of background water was identified to increase from -6.14 HU to -0.43 HU, whereas SUV decreased from 6.3 to 5.6 and A.U also decreased from 0.12 to 0.10. In addition, as for the patient image, CT number was verified to increase from 53.09 HU to 58.31 HU and SUV decreased from 24.96 to 21.81 when the patient's arm was positioned over the head rather than when it was lowered. Conclusion: When arms up protocol was applied, the SUV of phantom and patient image was decreased by 1.4% and 9.2% respectively. With the present study it was concluded that in case of PET/CT scanning against the whole body of a patient the position of patient's arm was not so much significant. Especially, the scanning under the condition that the arm is raised over to the head gives rise to more probability that the patient is likely to move due to long scanning time that causes the increase of uptake of $^{18}F$-FDG of brown fat at the shoulder part together with increased pain imposing to the shoulder and discomfort to a patient. As regarding consideration all of such factors, it could be rationally drawn that PET/CT scanning could be made with the arm of the subject lowered.

  • PDF