• Title/Summary/Keyword: 환자 안전

Search Result 1,551, Processing Time 0.034 seconds

Ultrasound-Guided Axillary Brachial Plexus Block, Performed by Orthopedic Surgeons (정형외과 의사가 시행한 초음파 유도 액와 상완 신경총 차단술)

  • Kim, Cheol-U;Lee, Chul-Hyung;Yoon, Ja-Yeong;Rhee, Seung-Koo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.513-521
    • /
    • 2018
  • Purpose: The purpose of this study was to assess the effectiveness and complications of an ultrasound-guided axillary brachial plexus block performed by orthopedic surgeons. Materials and Methods: From March to May 2017, an ultrasound-guided axillary brachial plexus block was performed on a total of 103 cases of surgery. A VF13-5 transducer from Siemens Acuson X300 was used. The surgical site was included in the range of the anatomic sensory distribution of the blocked nerve, except for the case where an operation time of more than 2 hours was expected due to multiple injuries and the operation of the upper arm. The procedure was performed by 2 orthopedic surgeons in the same method using 50 ml of solution (20 ml of lidocaine HCl in 2%, 20 ml of ropivacaine in 0.75%, 10 ml of normal saline in 0.9%). The success rate of anesthesia induction during surgery, anesthetic induction time, anatomical range of operation, duration of postoperative analgesia and complications were investigated. Results: The results from the 2 practices were similar. The anesthesia was successful in 100 out of 103 patients (97.1%). In these patients, the average needling time was 5.5 minutes (2.5-13.2 minutes), the average induction time to complete anesthesia was 18.4 minutes (5-40 minutes), and the average duration of postoperative analgesia was 402.8 minutes (141-540 minutes). The post-anesthesia immediate complications were dizziness in 1 case, nausea and vomiting in 4 cases, and peri-oral numbness in 2 cases, but surgery was performed without problems. All these 7 cases with complications recovered on the same day. A total of 3 cases failed with anesthesia, and they were treated by an injection with local anesthesia in the operation room in 2 cases and switched to general anesthesia in 1 case. Conclusion: An ultrasound-guided axillary brachial plexus block, which was performed by orthopedic surgeons allows anesthesia in a brief period and the high success rates of anesthesia for certain surgeries of the elbow and surgeries on forearm, wrist and hand. Therefore, it can reduce the waiting time to the operating room. This technique is a relatively safe procedure and dose selective anesthesia is possible.

Comparison of Gap Pressure in Opening Wedge High Tibial Osteotomy versus Compressive Strength of Allogenous Wedge Bone Blocks (경골 근위부 개방 절골술 시 개방부 압력과 동종 쐐기 골편의 최대압축하중 비교)

  • Yoon, Kyoung Ho;Kim, Jung Suk;Kwon, Yoo Beom;Kim, Eung Ju;Lee, Myeong-Kyu;Kim, Sang-Gyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.2
    • /
    • pp.127-134
    • /
    • 2020
  • Purpose: The aims of this study were (1) to investigate the relationship between the characteristics of allogenic bone block and the compressive strength of an allogenic bone block measured by biomechanical experiments, and (2) to compare the maximum pressure load of allogenic bone block with the gap pressure measured at the high tibial opening osteotomy. Materials and Methods: Ten patients who provided informed consent for gap pressure measurements during opening wedge high tibial osteotomy (OWHTO) were included. The gap pressures were measured at 1 mm intervals while opening the osteotomy site from 8 mm to 14 mm. Seventeen U-shaped allogenous wedge bone blocks were made from the femur, tibia, and humerus. The height, width, cross-sectional area, and cortex thickness of the bone blocks were measured, along with the maximum compressive load just before breakage. The relationship between these characteristics and the maximum pressure load of the bone blocks was evaluated. The gap pressures measured in OWHTO were compared with the maximum pressure loads of the allogenous wedge bone blocks to evaluate the possibility of inserting allogenous wedge bone blocks into the osteotomy site without a distractor in OWHTO. Results: The OWHTO gap pressure increased with increasing osteotomy site opening. The mean gap pressure, which occurred at a 14-mm opening, was 282±93 N; the maximum pressure was 427 N. The maximum pressure load of the allografts was 13,379±6,469 N (minimum, 5,868; maximum, 29,130 N) and was correlated significantly with the cortical bone thickness (correlation coefficient=0.693, p=0.002) and cross-sectional area (correlation coefficient=0.826, p<0.001). Depending on the sterilization method, the maximum pressure loads for the bone blocks were 13,406±5,928 N for freeze-dried and 13,348±7,449 N for fresh frozen. The maximum compressive load of the allogenous wedge bone blocks was 13.7-times greater than that in OWHTO opened to 14 mm (5,868 N vs. 427 N). Conclusion: The compressive strength of allogenous wedge bone blocks was sufficiently greater than the gap pressure in OWHTO. Therefore, allogenous wedge bone blocks can be inserted safely into the osteotomy site without a distractor.

Exploratory Study of Person Centered Care Practice in Korean Long-term Care Facilities using DCM(Dementia Care Mapping) as a tool (DCM(Dementia Care Mapping)을 활용한 한국 요양시설에서의 사람중심케어 실천의 탐색적 연구)

  • Kim, Dongseon
    • 한국노년학
    • /
    • v.41 no.2
    • /
    • pp.197-215
    • /
    • 2021
  • This study aims to evaluate Person Centered Care practice and characteristics of care services in Korean long-term care facilities using Dementia Care Mapping as a tool. DCM, systematic observational evaluation tool for measuring dementia patients' QOL, was transformed into self-report rating scale. The process of transforming DCM into a scale of 34 items involves operationalization of DCM concepts and it's adaptation into Korean long-term care practices. Review by research team of Bradford university was added to maintain DCM concept and meaning in this scale. The scale with Cronbach alpha of .88 was surveyed on 343 care workers. Survey result shows PCC value practiced by them is 3.77(of 5 likert scale) and values on each categories of PCC reveal the characteristics of care in Korean facilities; attachment(4.02), comfort(3.95), inclusion(3.89), identity(3.67) and occupation(3.41). Dementia care in Korean facilities focuses on recipients'safety, comfort but lacks individualistic care and the meaningful and fulfilling occupation for patients. Looking at the organizational and individual factors influencing DCM values, the small facilities showed higher PCC values and there are no significant difference in PCC values between public and private facilities. Managers and care workers with career of 1~2 years showed higher PCC values compared to other career ranks and lengthes. This study suggests care practice should be centered on personhood of patients in long-term care facilities, for which introduction of unit care and education of PCC for service providers including support personnel are needed. DCM and Korean DCM scale developed in this study are suggested for the PCC-based assessment on care quality.

The Effects of Communication Competence, Clinical Competence and Experience of Handover on Self-efficacy of Handover Reporting among Nursing Students (간호대학생의 의사소통능력, 임상수행능력, 인수인계 경험이 인수인계 자기효능감에 미치는 영향)

  • Oh, Hyo-Sook
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.4
    • /
    • pp.321-331
    • /
    • 2020
  • This study was conducted to investigate communication competence, clinical competence and experience of handover which influence self-efficacy of handover among nursing students. The study design was a descriptive survey. A total of 255 students were recruited from nursing departments in G-city. Structured questionnaire was self-administrated from June to September, 2019. The collected data were analyzed using t-test, ANOVA, Pearson's coefficient and stepwise multiple regression. As results of the study, communication competence 57.3, clinical competence 69.8 and self-efficacy of handover was 33.8. Self-efficacy of handover had significant differences in gender(F=4.60, p<.001), age(F=16.72, p<.001), grade(t=-6.39, p<.001), satisfaction of clinical practice(F=3.68, p=.027), education experience about handover(t=26.44, p<.001), experience of handover(t=4.84, p<.001), fear of handover(F=16.97, p<.001), and handover importance of patient's safety(F=6.42, p=.002). Self-efficacy of handover had significant positive correlations with communication competence(r=.249, p<.001) and clinical competence(r=.426, p<.001). In multiple regression analysis, fear of handover(β=-.294, p<.001), clinical competence(β=.252, p<.001), grade(β=.191, p=.001), experience of handover(β=.185, p<.001), gender(β=.150, p=.003), and education experience about handover(β=.126, p=.017) were significant factors of self-efficacy of handover explaining 40.0%(F=29.26, p<.001) of the variables. In conclusion, to enhance self-efficacy of handover for nursing students, it is necessary to develop educational program for increasing experiences of handover, education experience about handover, and clinical competence.

Investigation of Domestic and Foreign Unexpected Antibodies for Emergency Blood Transfusion (응급수혈을 위한 비예기 항체의 국내·외 실태조사)

  • Weonjoo, Hwang;Sang-Hee, Lee;Chang-Eun, Park
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.4
    • /
    • pp.279-284
    • /
    • 2022
  • Certain pre-transfusion tests are not commonly performed during emergency blood transfusion. In this study, we reviewed and analyzed the data of post-blood transfusion antibody screening tests to establish the effects of unexpected antibodies causing hemolytic transfusion reactions. We reviewed information published domestically and internationally, and selected the data of 68,602 antibody screening tests and 528 antibody identification tests conducted at P hospital. We found that unexpected antibody positive (1198,1.74%), Rh type (161, 30.49%), Lewis type (67, 12.69%), others (Di (a), 28, 5.30%). The anti-E type positive was 93 (17.61%), and that of the cases with anti-C (13, 2.46%). Only data of domestic cases were included for analysis that were published before 2007, which established the presence of antibodies of the following types and numbers of cases: anti-E (196, 22.45%), anti-Le a (82, 9.39%), and anti-E+C (60, 6.87%). In 2018, anti-E (107, 17.12%), anti-E+Canti-E+C (56, 8.96%), and anti-Di a (28, 4.48%) were detected. In other domestic cases, S hospital was detect to anti-E, anti-Le a, anti-E+C. The Anti-E, anti-D, anti-E+C, and anti-C+E were detected in D hospital. In Saudi Arabia, Anti-D, anti-E, and anti-Jka was detected. The Anti-M, Anti-N, Anti-Le (a), and Anti-D were detected in India. Requests for emergency blood transfusion increased 1.8 times after the opening of the trauma center. This study has the disadvantage of being a cross-sectional study. additional studies are needed to provide basic information on alternative treatments that can increase the safety and reduce the side effects of hemolytic transfusion in emergency transfusion situations.

Evaluation and Verification of the Attenuation Rate of Lead Sheets by Tube Voltage for Reference to Radiation Shielding Facilities (방사선 방어시설 구축 시 활용 가능한 관전압별 납 시트 차폐율 성능평가 및 실측 검증)

  • Ki-Yoon Lee;Kyung-Hwan Jung;Dong-Hee Han;Jang-Oh Kim;Man-Seok Han;Jong-Won Gil;Cheol-Ha Baek
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.489-495
    • /
    • 2023
  • Radiation shielding facilities are constructed in locations where diagnostic radiation generators are installed, with the aim of preventing exposure for patients and radiation workers. The purpose of this study is seek to compare and validate the trend of attenuation thickness of lead, the primary material in these radiation shielding facilities, at different maximum tube voltages by Monte Carlo simulations and measurement. We employed the Monte Carlo N-Particle 6 simulation code. Within this simulation, we set a lead shielding arrangement, where the distance between the source and the lead sheet was set at 100 cm and the field of view was set at 10 × 10 cm2. Additionally, we varied the tube voltages to encompass 80, 100, 120, and 140 kVp. We calculated energy spectra for each respective tube voltage and applied them in the simulations. Lead thicknesses corresponding to attenuation rates of 50, 70, 90, and 95% were determined for tube voltages of 80, 100, 120, and 140 kVp. For 80 kVp, the calculated thicknesses for these attenuation rates were 0.03, 0.08, 0.21, and 0.33 mm, respectively. For 100 kVp, the values were 0.05, 0.12, 0.30, and 0.50 mm. Similarly, for 120 kVp, they were 0.06, 0.14, 0.38, and 0.56 mm. Lastly, at 140 kVp, the corresponding thicknesses were 0.08, 0.16, 0.42, and 0.61 mm. Measurements were conducted to validate the calculated lead thicknesses. The radiation generator employed was the GE Healthcare Discovery XR 656, and the dosimeter used was the IBA MagicMax. The experimental results showed that at 80 kVp, the attenuation rates for different thicknesses were 43.56, 70.33, 89.85, and 93.05%, respectively. Similarly, at 100 kVp, the rates were 52.49, 72.26, 86.31, and 92.17%. For 120 kVp, the attenuation rates were 48.26, 71.18, 87.30, and 91.56%. Lastly, at 140 kVp, they were measured 50.45, 68.75, 89.95, and 91.65%. Upon comparing the simulation and experimental results, it was confirmed that the differences between the two values were within an average of approximately 3%. These research findings serve to validate the reliability of Monte Carlo simulations and could be employed as fundamental data for future radiation shielding facility construction.

Comparison of the Clinical Outcomes of a Single Injection Adductor Canal Block with the Concomitant Use of Transdermal Buprenorphine and Continuous Adductor Canal Block after Total Knee Arthroplasty (슬관절 인공관절 전치환술 후 일회 주사 내전근관 차단술 및 경피성 Buprenorphine 병합 요법과 도관 삽입 지속적 내전근관 차단술의 임상결과 비교)

  • Huh, Jung-Wook;Park, Man-Jun;Ko, Young-Chul;Ha, Dong-Jun;Park, Joon-Hyung;Lee, Woo-Myung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.5
    • /
    • pp.411-417
    • /
    • 2019
  • Purpose: To compare the clinical outcomes of single injection adductor canal block (SACB), continuous adductor canal block (CACB), and the concomitant use of transdermal buprenorphine after total knee arthroplasty (TKA). Materials and Methods: A total of 125 patients who underwent TKA were divided into three groups and the clinical results were retrospecitively compared. Group I was comprised of patients with pain controlled by SACB (n=41). Group II consisted of patients with pain controlled by both SACB and transdermal buprenorphine (10 ㎍/h) (n=44). Group III contained patients with pain controlled by CACB (n=40). The visual analogue scale (VAS) was used as the pain control indicator and the patients were measured on a VAS for resting on the bed (VAS-Rest) at 12 hours, 24 hours, and 48 hours after surgery. The VAS while doing continuous passive motion (VAS-CPM) on the first and second postoperative day was also measured. In addition, the total amount of medications used (Butopahn, Tridol, and Ketorac) for the intravenous patient controlled analgesia (PCA) was counted for 48 hours after surgery. As the indicator of the functional recovery outcome, the incidence of nausea and vomiting was observed for 48 hours after surgery. The maximum knee joint flexion range and maximum walking distance on the first and second postoperative day, and the total length of stay at the hospital were compared. Results: The VAS-Rest was similar in the three groups at 12 hours after surgery, but at 24 hours and 48 hours after surgery, group II and III a lower VAS-CPM and total amount of medications used for PCA than group I (p<0.05). The three groups showed a low incidence of nausea and vomiting, maximum knee joint flexion range, and similar walking distance and total length of stay at the hospital. Conclusion: The combination of SACB and transdermal buprenorphine has great pain control effect initially. On the other hand, it is not associated with catheter complications and it is convenient to use and safety toward the renal function. Therefore, the concomitant use of SACB and transdermal buprenorphine can be an effective pain control method after TKA.

Experimental investigation of the photoneutron production out of the high-energy photon fields at linear accelerator (고에너지 방사선치료 시 치료변수에 따른 광중성자 선량 변화 연구)

  • Kim, Yeon Su;Yoon, In Ha;Bae, Sun Myeong;Kang, Tae Young;Baek, Geum Mun;Kim, Sung Hwan;Nam, Uk Won;Lee, Jae Jin;Park, Yeong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.257-264
    • /
    • 2014
  • Purpose : Photoneutron dose in high-energy photon radiotherapy at linear accelerator increase the risk for secondary cancer. The purpose of this investigation is to evaluate the dose variation of photoneutron with different treatment method, flattening filter, dose rate and gantry angle in radiation therapy with high-energy photon beam ($E{\geq}8MeV$). Materials and Methods : TrueBeam $ST{\time}TM$(Ver1.5, Varian, USA) and Korea Tissue Equivalent Proportional Counter (KTEPC) were used to detect the photoneutron dose out of the high-energy photon field. Complex Patient plans using Eclipse planning system (Version 10.0, Varian, USA) was used to experiment with different treatment technique(IMRT, VMAT), condition of flattening filter and three different dose rate. Scattered photoneutron dose was measured at eight different gantry angles with open field (Field size : $5{\time}5cm$). Results : The mean values of the detected photoneutron dose from IMRT and VMAT were $449.7{\mu}Sv$, $2940.7{\mu}Sv$. The mean values of the detected photoneutron dose with Flattening Filter(FF) and Flattening Filter Free(FFF) were measured as $2940.7{\mu}Sv$, $232.0{\mu}Sv$. The mean values of the photoneutron dose for each test plan (case 1, case 2 and case 3) with FFF at the three different dose rate (400, 1200, 2400 MU/min) were $3242.5{\mu}Sv$, $3189.4{\mu}Sv$, $3191.2{\mu}Sv$ with case 1, $3493.2{\mu}Sv$, $3482.6{\mu}Sv$, $3477.2{\mu}Sv$ with case 2 and $4592.2{\mu}Sv$, $4580.0{\mu}Sv$, $4542.3{\mu}Sv$ with case 3, respectively. The mean values of the photoneutron dose at eight different gantry angles ($0^{\circ}$, $45^{\circ}$, $90^{\circ}$, $135^{\circ}$, $180^{\circ}$, $225^{\circ}$, $270^{\circ}$, $315^{\circ}$) were measured as $3.2{\mu}Sv$, $4.3{\mu}Sv$, $5.3{\mu}Sv$, $11.3{\mu}Sv$, $14.7{\mu}Sv$, $11.2{\mu}Sv$, $3.7{\mu}Sv$, $3.0{\mu}Sv$ at 10MV and as $373.7{\mu}Sv$, $369.6{\mu}Sv$, $384.4{\mu}Sv$, $423.6{\mu}Sv$, $447.1{\mu}Sv$, $448.0{\mu}Sv$, $384.5{\mu}Sv$, $377.3{\mu}Sv$ at 15MV. Conclusion : As a result, it is possible to reduce photoneutron dose using FFF mode and VMAT method with TrueBeam $ST{\time}TM$. The risk for secondary cancer of the patients will be decreased with continuous evaluation of the photoneutron dose.

Respiratory Gas Exchange and Ventilatory Functions at Maximal Exercise (최대운동시의 호흡성 가스교환 및 환기기능)

  • Cho, Yong-Keun;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.900-912
    • /
    • 1995
  • Background: Although graded exercise stress tests are widely used for the evaluation of cardiorespiratory performance, normal standards on respiratory gas exchange and ventilatory functions at maximal exercise in Koreans have not been well established. The purpose of this study is to provide reference values on these by sex and age, along with derivation of some of their prediction equations. Method: Symptom-limited maximal exercise test was carried out by Bruce protocol in 1,000 healthy adults consisting of 603 males and 397 females, aged 20~66 years. Among them VC, $FEV_1$ and MVV were also determined in 885 cases. All the subjects were members of a health center, excluding athletes. During the exercise, subjects were allowed to hold on to front hand rail of the treadmill for safety purpose. Results: The $VO_2\;max/m^2$, $VCO_2\;max/m^2$ and $V_E\;max/m^2$ were greater in males than in females and decreased with age. The RR max in men and women was similar but decreased slightly with age. The $V_T$ max was markedly greater in men but showed no significant changes with age in either gender. The mean of $V_T$ max/VC, $V_E$ max/MVV and BR revealed that there were considerable ventilatory reserves at maximal exercise even in older females. The regression equations of the cardinal parameters obtained using exercise time(ET, min), age(A, yr), height(Ht, cm), weight(W, kg), sex(S, 0=male; 1=female), VC(L), $FEV_1$(L) and $V_E$ max(L) as variables are as follows: $VO_2\;max/m^2$(L/min)=1.449+0.073 ET-0.007A+0.010W-0.006Ht-0.209S, $VCO_2\;max/m^2$(L/min)=1.672+0.063ET-0.008A+0.010W-0.005Ht-0.319S, VE max/$m^2$(L/min)=58.161+1.503ET-0.315A-9.871S or VE max/$m^2$(L/min)=47.873+6.548 $FEV_1$-5.715 S, and VT max(L)=1.497+0.223VC-0.493S. Conclusion: Respiratory gas exchange and ventilatory variables at maximal exercise were studied in 1,000 non-athletes by Bruce protocol. During exercise, the subjects were allowed to hold on to hand rail of the treadmill for safety purpose. We feel that our results would provide ideal target values for patients and healthy individuals to be achieved, since our study subjects were members of a health center whose physical fitness levels were presumably higher than ordinary population.

  • PDF

The Changes of Brain Injury Markers(S100-$\beta$, Neuron-Specific enolase) After Retrograde Cerebral Perfusion Under Total Circulatory Arrest in Pigs (돼지에서 역행성 뇌관류 시행 후 혈청 및 소변의 뇌손상 관련지표(S100-$\beta$, Neuron-specific enolase)의 변화)

  • 김상윤;김만호;김경환
    • Journal of Chest Surgery
    • /
    • v.35 no.12
    • /
    • pp.847-853
    • /
    • 2002
  • We previously published the data that proved the safety of retrograde cerebral perfusion for 120 minutes. At this time, we planned to check the neuron-specific enolase and S100-$\beta$ in serum and urine to assess the possibility of early detection of cerebral injury. Material and Method: We used pigs(Landrace species) weighing 35 kg and performed RCP for 120 minutes. After the weaning of cardiopulmonary bypass, we observed the pigs for another 120 minutes. Systemic arterial pressure, central venous pressure, and serum and urine levels of neuron-specific enolose (NSE) and S100$\beta$ protein were checked. Central venous pressure during RCP was maintained in the range of 20 to 25 mmHg. Result: Serum levels of NSE(ng/$m\ell$) were 0.67$\pm$0.18(induction of anesthesia), 0.53$\pm$0.47(soon after CPB), 0.44$\pm$0.27(20min alter CPB), 0.24$\pm$0.09(RCP 20min), 0.37$\pm$0.35(RCP 40min), 0.33$\pm$0.21 (RCP 60min), 0.37$\pm$0.22(RCP 80min), 0.41$\pm$0.23(RCP 100 min), 0.48$\pm$0.26(RCP 120min), 0.42$\pm$0.29(30min after rewarming), 0.35 $\pm$0.32(60min after rewarming, 0.42$\pm$0.37(CPBoff 30min), 0.47$\pm$0.34(CPBOff 60min), 0.47$\pm$0.28(CPBOff 90min), and 0.57$\pm$0.29(CPBOff 120min). There was no statistically significant difference in levels between before and after RCP(ANOVA, p>0.05). Urine levels of NSE also showed no statistically significant difference in levels between before and after RCP. There was no correlation between urine and serum levels of NSE(Pearson correlation, p>0.05). Serum levels of S100$\beta$ protein(ng/$m\ell$) during the same time frames were 0.14$\pm$0.08, 0.15$\pm$0.07, 0.22$\pm$0.15, 0.23$\pm$0.07, 0.28$\pm$0.10, 0.40$\pm$0.05, 0.47$\pm$0.03, 0.49$\pm$0.12, 0.43$\pm$0.11, 0.46$\pm$0.15, 0.62$\pm$0.17, 0.77$\pm$0.21, 0.78$\pm$0.23, 0.77$\pm$0.23, and 0.82$\pm$0.33. There was statistically significant difference in levels between before and after RCP(ANOVA, p<0.05). Urine levels of NSE also showed statistically significant difference in levels between before and after RCP(ANOVA, p<0.05). There was significant correlation between urine and serum levels of NSE(Pearson correlation, p<0.05). Conclusion: The author observed the increase in serum and urine levels of S100$\beta$ after 120 minutes of RCP. Significant correlation between serum and urine levels was observed. The results were considered to be the fundamental data that could correlate this study with human-based study.