Technical Review of Target Volume Delineation on the Posterior Fossa Tumor : An Optimal Head and Neck Position (후두와 종양의 방사선치료 시 표적용적의 결정을 위한 적절한 치료자세 연구)

  • Yoon Sang Min;Lee Sang-wook;Ahn Seung Do;Kim Jong Hoon;YE Byong Yong;Ra Young Shin;Kim Tae Hyung;Choi Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.94-99
    • /
    • 2003
  • Purpose : To explore a 3D conformal radiotherapy technique for a posterior fossa boost, and the potential advantages of a prone position for such radiotherapy. Materials and Methods :A CT simulator and 3D conformal radiotherapy Planning system was used for the posterior fossa boost treatment on a 13-year-old medulloblastoma patient. He was placed In the prone position and Immobilized with an aquaplast mask and immobilization mold. CT scans were obtained of the brain from the top of the skull to the lower neck, with IV contrast enhancement. The target volume and normal structures were delineated on each slice, with treatment planning peformed using non-coplanar conformal beams. Results : The CT scans, and treatment In the prone position, were peformed successfully. In the prone position, the definition of the target volume was made easier due to the well enhanced tentorium, In audition, the posterior fossa was located anteriorly, and with the greater choice of beam arrangements, more accurate treatment planning was possible as the primary beams were not obstructed by the treatment table. Conclusion : .A posterior fossa boost, in the prone position, Is feasible in cooperating patients, but further evaluation is needed to define the optimal and most comfortable treatment positions.

The Results of Radiation Therapy of Limited Stage Small Cell Lung Cancer (국한된 페소세포암의 방사선 치료성적)

  • Kim Sung Hwan;Choi Byung Ok;Gil Hak Joon;Yoon Sei Chul;Bahk Yong Whee;Shinn Kyung Sub;Kim Hoon Kyo;Lee Kyung Sik
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.97-102
    • /
    • 1993
  • A retrospective analysis of various characteristics in 32 limited stage small cell lung cancer patients treated at the Department of Therapeutic Radiology in Kangnam St. Mary's Hospital, Catholic University Medical College from April 1983 to September 1991, was carried out to identify factors which had prognostic significance for survival from initiation of radiation therapy. There were 26 men and 6 women. Median age was 63 years (range: 24-78 years). The follow up duration was 1.5 to 44 months (median: 9 months). External radiation therapy was done with daily 160-180 cGy,5 fraction/week, total of 1000-6660 cGy (median: 4500 cGy) to the mediastinum by 6 MV linear accelerator. Of 32 Patients, 27 ($84.4{\%}$) patients were treated with combined modality (chemotherapy plus radiation therapy), and 5 ($15.6{\%}$) patients were treated with radiation therapy only. Complete responders were 12 patients ($37.5{\%}$), partial responders were 11 ($34.4{\%}$), and no responders were 9($28.1{\%}$). Karnofsky performance status over 70 (p<0.04), chemotherapy regimen (CAV, PV, and CAV+PV) (p<0.04),6 or more cycles of chemotherapy (p<0.007), radiation therapy over 4500 cGy (p<0.03), and radiation therapy responder (CR+PR) (p<0.003) showed a significantly favorable influence on 1 year survival rate. Age (p=0.545), sex (p=0.666), presence of superior vena cava syndrome (p=0.719), prophylactic cranial irradiation (p=0.217), and radiation therapy duration (p=0.491) had no effect on survival. Radiation induced side effects were transient esophagitis in 11 ($34{\%}$), general weakness in 9($28{\%}$), gastrointestinal symptoms in terms of nausea, vomiting and indigestion in 5 ($15{\%}$) and leukopenia in 1 ($3{\%}$).

  • PDF

The Assessment of Scattered Ray According to the Beam Thickness of Z-axis in MDCT(Multi Detector Computed Tomography) (MDCT(다배열검출기 전산화단층촬영장치)에서 Z-축의 빔 두께에 따른 산란선의 평가)

  • Ryu, Gwi-Bok;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Dong, Kyung-Rae;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • The purpose of this study is to measure scattered ray which is occurred except for Z-axis range of the detector in MDCT's iso-center and present the basic data about the standard for reduction of scattered ray. The development of MDCT brings out the enlargement of beam thickness to the patient's Z-axis, which distributes to the increase in exposure dose according to the rise of scattered ray. Also MDCT brings out the increase of scattered ray about 4times more than SDCT. To evaluate scattered ray according to the change of beam thickness on MDCT, we measured scattered ray of MDCT's Z-axis beam thickness by using one 16-slice CTs and two 64-slice CTs. We used the ionization chamber 60ml 2026C as the equipment of measurement. In our results, we found out that the change of scattered ray according to the beam thickness in the same kVp has increase of scattered ray. Secondly we found out the increase of scattered ray according to the increase of kVp. Lastly we found out the decrease of scattered ray according to the increase of the distance from the ionization chamber.

Local Control and Survival in Radiation Treatment of Locally Advanced Non-Small Cell Lung Cancer (III 병기 비소세포성 폐암의 방사선 치료성적)

  • Song, Mi-Hee;Yong, Jin-Young;Oh, Won-Young;Yoo, Nam-Soo;Whang, In-Soon
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.311-319
    • /
    • 1993
  • The retrospective analysis was performed on 37 patients with stage III non small cell lung cancer who received the radiotherapy from Feb. 1986 to Dec. 1990 at the Dept. of Radiation Oncology, National Medical Center. This analysis, with 29 patients $(78.4\%)$ having been followed from 10 to 60 months, was done to know the survival rate and significant prognostic factor. The actuarial 2,5-year survival rates were $20.6\%,6.9\%$ in our all patients and median survival time was 10 months. Of patients with KPS (Karnofsky prformance status) greater than $80\%,$ the 2, 5 year survival rate and median survival time were $29.2\%,9.7\%$ and 13 months, respectively. The 2-year survival rate and median survival time of patients with KPS less than $80\%\;were\;13.7\%$ and 7 months, respectively. The survival difference according to performance status was statisticaly significant $(29.2\%\;vs.\;13.7\%)(p<0.05).$ In stage IIIa, the 2,5-year survival rate and median survival rate and median survival time were $29.2\%,9.7\%$ and 12 months, respectively. The 2-year survival rate and metian survival time of stage IIIb were $8.6\%$ and 10 months, respectively. The survival difference between stage IIIa and IIIb did not show statistical significance (p>0.1). Of the prognostic factors, the difference of survival rate by initial performance status was statistically significant (p<0.05). But the difference of survival rates by pathologic cell type, stage, total radiation dose, radiotherapy response, and cmbination with chemotherapy were not statistically significant.

  • PDF

Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City (1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로)

  • Dong, Kyung-Rae;Lee, Seun-Joo;Kweon, Dae-Cheol;Goo, Eun-Hoe;Jung, Jae-Eun;Lee, Kyu-Su
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within $1.5^{\circ}$. Of all fifty hospitals 30.0% were beyond $3^{\circ}$. The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible.

Analysis of Factors Influencing the Integrated Bolus Peak Timing in Contrast-Enhanced Brain Computed Tomographic Angiography (Computed Tomographic Angiography (CTA)의 검사 시 조영제 집적 정점시간에 영향을 미치는 특성 인자를 분석)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Jung, Jae-Yong;Yun, Jung-Soo;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.59-69
    • /
    • 2016
  • The objective of this study was to analyze the factors influencing integrated bolus peak timing in contrast-enhanced computed tomographic angiography (CTA) and to determine a method of calculating personal peak time. The optimal time was calculated by performing multiple linear regression analysis, after finding the influence factors through correlation analysis between integrated peak time of contrast medium and personal measured value by monitoring CTA scans. The radiation exposure dose in CTA was $716.53mGy{\cdot}cm$ and the radiation exposure dose in monitoring scan was 15.52 mGy (2 - 34 mGy). The results were statistically significant (p < .01). Regression analysis revealed, a -0.160 times decrease with a one-step increase in heart rate in male, and -0.004, -0.174, and 0.006 times decrease with one-step in DBP, heart rate, and blood sugar, respectively, in female. In a consistency test of peak time by calculating measured peak time and peak time by using the regression equation, the consistency was determined to be very high for male and female. This study could prevent unnecessary dose exposure by encouraging in clinic calculation of personal integrated peak time of contrast medium prior to examination.

The Results of Combined Modality Treatment with Transurethral Resection, Cisplatin and Radiation Therapy for Invasive Bladder Cancer (침윤성 방광암에서 경요도적절제술 및 Cisplatin과 방사선의 병용치료의 효과)

  • Oh, Yoon-Kyeong
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.311-317
    • /
    • 1991
  • Ten patients with deep muscle-invading bladder carcinoma (clinical stages T3a to T4b) who were not candidates for cystectomy were treated with combined modality treatment with transurethral resection, cisplatin chemotherapy and pelvic irradiation from 1989 through 1990, and were analyzed retrospectively. All patients were not candidates for cystectomy because the tumors were judged unresectable or they were not fit for a radical cystectomy. Of the patients 5 had clinical stage T3a, 3 stage T3b and 2 stage T4b disease. The minimum follow-up was 16 months. The complete response rate is 60$\%$ for all patients. The complete responses were achieved in 4 of 5(80$\%$) with stage cT3a, in 2 of 3(67$\%$)with stage cT3b and in none of 2(0$\%$) with stage cT4b. The partial responses were achieved in 2, so an overall response rate was 80$\%$. All six patients with grade I or II transitional cell carcinoma showed complete responses. Four patients with higher grade tumors showed partial responses in 2 and no response in 2, and all died of their bladder cancer. Six patients who showed complete responses after treatment are alive and only one of them showed a local recurrence 10 months after treatment. Distant metastases developed in 3 patients: lungs in 2(cT4b) of those who were never locally free of disease and spine in 1 patient (cT3b) among those with a partial response. Two patients died of metastases to lungs. During the follow-up diarrhea occurred in one which was improved after conservative treatment. On the basis of this analysis it is suggested that combined modality treatment seems to be a tolerable regimen and can be offered with a relatively high probability of success and conservation of bladder function in those with less advanced tumors by clinical stage and low grade.

  • PDF

A Study on the Change of Image Quality According to the Change of Tube Voltage in Computed Tomography Pediatric Chest Examination (전산화단층촬영 소아 흉부검사에서 관전압의 변화에 따른 화질변화에 관한 연구)

  • Kim, Gu;Kim, Gyeong Rip;Sung, Soon Ki;Kwak, Jong Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.503-508
    • /
    • 2019
  • In short a binary value according to a change in the tube voltage by using one of VOLUME AXIAL MODE of scanning techniques of chest CT image quality evaluation in order to obtain high image and to present the appropriate tube voltage. CT instruments were GE Revolution (GE Healthcare, Wisconsin USA) model and Phantom used Pediatric Whole Body Phantom PBU-70. The test method was examined in Volume Axial mode using the pediatric protocol used in the Y university hospital of mass-produced material. The tube voltage was set to 70kvp, 80kvp, 100kvp, and mAs was set to smart mA-ODM. The mean SNR difference of the heart was $-4.53{\pm}0.26$ at 70 kvp, $-3.34{\pm}0.18$ at 80 kvp, $-1.87{\pm}0.15$ at 100 kvp, and SNR at 70 kvp was about -2.66 higher than 100 kvp and statistically significant (p<0.05) In the Lung SNR mean difference analysis, $-78.20{\pm}4.16$ at 70 kvp, $-79.10{\pm}4.39$ at 80 kvp, $-77.43{\pm}4.72$ at 100 kvp, and SNR at 70 kvp at about -0.77 higher than 100 kvp were statistically significant. (p<0.05). Lung CNR mean difference was $73.67{\pm}3.95$ at 70 kvp, $75.76{\pm}4.25$ at 80 kvp, $75.57{\pm}4.62$ at 100 kvp and 20.9 CNR at 80 kvp higher than 70 kvp and statistically significant (p<0.05) At 100 kvp of tube voltage, the SNR was close to 1 while maintaining the quality of the heart image when 70 kvp and 80 kvp were compared. However, there is no difference in SNR between 70 kvp and 80 kvp, and 70 kvp can be used to reduce the radiation dose. On the other and, CNR showed an approximate value of 1 at 70 kvp. There is no difference between 80 kvp and 100 kvp. Therefore, 80 kvp can reduce the radiation dose by pediatric chest CT. In addition, it is possible to perform a scan with a short scan time of 0.3 seconds in the volume axial mode test, which is useful for pediatric patients who need to move or relax.

Fluoroscopic the equipment study in accordance with the entrance surface dose study of patients and practitioners (투시 검사 시 장비에 따른 환자와 시술자의 입사표면선량 연구)

  • Yang, Hae-Doo;Hong, Seon-Sook;Seong, Min-Sook;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.13-18
    • /
    • 2013
  • Purpose : Fluoroscopy equipment, depending on the type of changes that occur in the patient's position ESD and study the patient's scatter ray of ESD Practitioners considered a comparative analysis was to evaluate the correct dose. Materials and Methods : HITACHI four overtube type TU-8000 Flat Detector and Under tube C-Arm Philips' Multi Diagnost Eleva with Flat Detector type were measured by. Each devices is a measure of the patient's esd randophantom position in tabel unfors Xi multi funtion then fixed to the abdomen fluoroscopy and 10 seconds, spot was measured three times, practitioners of the incident surface dose by considering the patient's scatter ray of the table for each device in the average human stomach 21cm thickness acrylic phantom ($25cm{\times}25cm$) Place the practitioner position after position randophantom unfors Xi multi funtion in the thyroid and stomach 1 minute by a fixed one-time fluoroscopy and measured. Results : 10 seconds and the patient perspective of the c-arm ESD 1.2 times smaller on the AP and oblique measurements were measured in the 6-13 times smaller. spot positions to changes in the measured three times on the AP of the abdomen, ESD is 18 times smaller c-arm measurements and the oblique measurement was 19-30 times smaller. And 1 minute at practitioners fluoroscopy esd in the thyroid 2.12 times the c-arm, chest 1.75 times less the dose was measured. On the AP, depending on the device, but the lack of dose difference oblique positions of the two devices depending on changes in the area due to changes in both the AP than on the dose increased, the difference in dose between the two devices, the maximum difference was approximately 27 times. Conclusion : Fluoroscopic equipment at the time of inspection in accordance with changes in dose according to the patient and the patient's positions changes, because the area of the scatter ray considering the change of dose measurements be made, and study of the equipment according to the characteristics of the efficiency and the exposure of the patient and practitioner is considered smooth study equipment manufacturers that can be done is to build the system and think that is also important. Various fluoroscopy when you check future changes in many factors of change in dose for the equipment in the laboratory system by considering the scatter ray radiation shielding for the management to take advantage of reckless undertube have been utilized as more exposure Reduction activities can help is considered as the direction.

  • PDF

A study of beam hardening effect reduction occur in brain CT (Brain CT에서 발생하는 선속경화현상 감소방안에 관한 연구)

  • Kim, Hyeon-ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8479-8486
    • /
    • 2015
  • This study aim is occur in brain CT cause of beam hardening effect and reducing method, We will scan Bone opaque bead phantom on variation of image on the influence factor with equipment called 'Samatom Senation 16' with following listed herein : tube voltage, tube current, slice thickness, gantry angle, base line which affect beam-hardening effect. After that we are going to start Quantitative Analysis resulted in previous scanning and Qualitative Assessment with CT image sheet evaluation. result of quantitative analysis 140kVp $31.56{\pm}2.89HU$ on tube voltage, 150mA $-3.87{\pm}0.12HU$ on tube current, 3mm on slice thickness, and $13.31{\pm}1.03HU$ IOML on gantry angle which was the least beam-hardening effect. Like Qualitative Analysis, we went through Qualitative Assessment and most of valuers got a result of 140kVp on tube voltage, 150mA on tube current, 3mm on slice thickness. As before valuers evaluated gantry angle that scanned image from IOML or OML was the least beam-hardening effect occured. There are meaningful differences when we compare all theses factors statistically(P<0.05). therefore We consider that Minimizing artifact that caused by beam-hardening effect can provide better quality of image to deciphers and patients. if we rise tube voltage in permissible dose limit, set tube current in a limit that does not effect to image quality, use slice thickness too thin enough to harm resolution, use IOML or OML on gantry angle.