• Title/Summary/Keyword: 환자피폭선량

Search Result 445, Processing Time 0.025 seconds

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.

The Study for Radio Protection According to a Possible Danger of Exposure During low energy X-ray Examination (저 에너지 방사선 검사 시 노출 위험성에 따른 피폭선량 방어연구)

  • Lim, Cheong-Hwan;Jeong, Cheon-Soo
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.187-188
    • /
    • 2011
  • 저 에너지 방사선검사 시 부득이하게 방사선 노출을 받게 되는 방사선 작업종사자나 환자의 보호자가 위치와 거리에 따른 방사선 피폭 선량의 감소 방안을 알아보고자 한다. Ion chamber mode 2026c, Reader기 20X6-1800을 사용하여 구강내 검사와 구강외 검사의 각각 검사실과 조정실에서의 관전압의 변화, 관전류와 조사시간의 변화, 조사방향의 변화에 따라 선량을 측정하였다. 그 결과 검사실 안에서는 최고선량이 평균 $702.8{\mu}R$으로 측정 되었으며, 조정실 안에서 측정하였을 경우 $20{\mu}R$이하의 낮은 선량을 보였으며, 후방검사보다 측방검사가 낮은 선량으로 나타났다. 방사선검사 시 위치와 거리에 따른 조사선량을 비교 분석하여, 적절한 거리 확보와 조사되는 중심방사선을 기준으로 측방($90{\sim}135^{\circ}$)에 위치함으로써 방사선 방어에 도움을 줄 것이며, 차폐문을 이용하여 방사선 피폭으로부터 감소 효과를 볼 수 있을 것이다.

  • PDF

A Study on the Environmental Radiation Dose Measurement in the Nuclear Medicine Department (핵의학과에서 환경방사선량 측정에 대한 연구)

  • Kang, Bo-Sun;Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.6
    • /
    • pp.2118-2123
    • /
    • 2010
  • Korean individual occupational exposure control is focused on the retrospective service to the over-exposed person by the reading of personal dosimeter. Since the radiophamaceuticals using in the nuclear medicine department are uncontained radiation sources, the potential exposure at working environment is very high. Moreover, a patient remains radioactive for hours or even days after the administration of a radiopharmaceutical for diagnosis or treatment. Thus, the proper working environmental exposure control must be established and executed to protect not only the affiliated employees, but also guardians accompanying patients and temporarily visiting public from the exposure by the patients. Japanese radiation protection law regulates working environmental radiation exposure by regularly measuring and filing the environmental dose for years. This study was aimed at measuring working environmental radiation dose in the nuclear medicine department of an university hospital located in Daejeon, Korea. We measured the accumulation radiation dose in air at 8 locations in the nuclear medicine department by using the same method as in Japan with glass dosimeters. The highest dose rate, 0.23 mSv per month, was measured at the waiting room, and the second one is at reception desk. Even though the doses were lower than the Korean constraint dose rate (0.3 mSv/week) at the boundary of the radiation controlled area, it was over the dose limit of public (1 mSv/y) and environment (0.25 mSv/y). Conclusionally, it was found that the new or additional procedure was necessary to less the exposure dose to the receptionist and guardians by the environmental radiation dose in the nuclear medicine department.

Measurement of Patient Dose from Computed Tomography Using Physical Anthropomorphic Phantom (물리적 팬텀을 이용한 CT 촬영 환자의 피폭 선량 측정 및 평가)

  • Jang, Ki-Won;Lee, Choon-Sik;Kwon, Jung-Wan;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.3
    • /
    • pp.113-119
    • /
    • 2005
  • The computed tomogrpahy(CT) provides a high quality in images of human body but contributes to the relatively high patient dose. The frequency of CT examination is increasing and, therefore, the concerns about the patient dose are also increasing. In this study the experimental determination of patient dose was performed by using a physical anthropomorphic phantom and thermoluminescent dosimeter(TLD). The measurements were done for the both axial and spiral scan mode. As a result the effective doses for each scan mode were 17.78mSv and 10.01 mSv respectively and the fact that the degree of the reduction in the patient dose depends on the pitch scan parameter was confirmed. The measurement methods suggested in this study can be applied for the reassessment of the patient dose when the technique in CT equipment is developed or the protocol for CT scanning is changed.

A Survey of the Management of Patient Dose at Medical Center (의료기관의 환자 피폭선량 관리 실태조사)

  • Jeon, Go-Eun;Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.23-28
    • /
    • 2009
  • Medical radiation therapy using radioactive isotope I-131 is an extremely critical part of nuclear medicine. It is important to evaluate patients' radiation exposure dose for the safe handling of radiation in the medical area. Cautions related to patients' exposure to radiation are as follows. First, the dose should not exceed the level required for medical purpose. Second, unnecessary exposure should be avoided. Third, it should be considered carefully first whether the same medical purpose is attainable without the use of radiation. For these purposes, we need to evaluate patients' radiation exposure dose. Thus, in order to promote the safety of patients in medical wards, this study sampled air using an air sampler and measured the radioactivity of the sample using a gamma counter. According to the results of measuring I-131 in medical wards, the highest level, the average and the lowest level were $404.11Bq/m^3$, $228.27Bq/m^3$ and $126.17Bq/m^3$, respectively.

  • PDF

Decreased of Patient Dose by Built-in Filter in Pelvis A-P Projection (골반촬영 시 내장된 필터를 이용한 환자선량 감소)

  • Shin, Seong-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.8
    • /
    • pp.233-239
    • /
    • 2012
  • This study was performed to find a method to decrease the radiation exposure of patients when obtaining anteroposterior pelvic images maintaining the quality of the image by using the copper filter built in the DR equipment now being used in our hospital. We measured the level of radiation by changing the filters from none filter to 0.1mmCu, 0.2mmCu, and 0.3mmCu and detected the organ level of radiation by PCXMC program. As a result, high levels of radiation were detected in the bladders and testicles and the levels were decreased as the thickness of the filter was increased and the amount of decrease was the highest in 0.1mmCu. And we asked for the expert opinions to 3 radiologists and as a result, only images obtained by 0.1mmCu filter out of all the images on which copper filters were used were accepted as the ones with diagnostic value same as none filter. At this time, the incident dose on the pelvic region was 0.895mGy which was smaller than the one in none filter by 47%. Therefore, using 0.1mmCu when obtaining anteroposterior pelvic images can effectively decrease the radiation exposure of patients.

A Study on the Radiation Exposure Dose of Brain Perfusion CT Examination a Phantom (Phantom을 이용한 뇌 관류 CT검사에서 방사선 피폭선량에 관한 연구)

  • Jung, Hong-Rynag;Kim, Ki-Jeong;Mo, Eun-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.5
    • /
    • pp.287-294
    • /
    • 2015
  • The purpose of this study, was Let's examine the exposure dose at the time of cerebral blood flow CT scan of acute ischemic stroke patients. In particular, long-term high doses of radiation sensitive organs and we Measured using phantom and a glass dosimeter. Apply the existing protocol suggested by the manufacturer (fixed time delay technique) and the proposed new convergence protocol (bolus tracking technique), reporting to measure the dose, dose reduction was to prepare the way. Results up to 39.8% as compared to the existing protocols in a new suggested convergence protocol, a minimum of 5.8% was long-term dose is reduced. Test dose of $CDTI_{vol}$ and DLP values decreased 25%, respectively, were measured at less than recommended dose. Try checking the protocol set out in the existing based on the analysis result of the above, by applying the proposed new convergence protocol by reducing the dose would have to contribute to improved public health. It is believed to be research continues to find the optimum protocol in the other tests.

The patient dose calculation model on the Exell program (촬영조건에 의한 환자 피폭선량의 자동계산 프로그램)

  • Kim, Jung-Min;Seok, Jin-Yong
    • Journal of radiological science and technology
    • /
    • v.25 no.2
    • /
    • pp.35-38
    • /
    • 2002
  • Recently, They are usually recording the patient information on the Hospital Information System. In the department of Radiology, For the purpose of assuming patient exposed dose, Authors contrived the mathematical calculation model by use of x-ray out put data on the Excel program, if they in put the exposure factors (kVp, mAs, thickness), the program could automatically calculate the patient Skin dose. The assuming data by three dimensional equation has average errors within ${\pm}5%$, there for We could make good use of clinical field in department of radiology.

  • PDF

Changes in External Radiation Dose Rate for PET-CT Test Patients (PET-CT 검사 환자의 외부 방사선량률 변화)

  • Kim, Su-Jin;Han, Eun-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.103-107
    • /
    • 2012
  • This paper analyzes changes in the external radiation dose rate of PET-CT test patients as a part of providing basic materials for reduction of radiation exposure to PET-CT test patients. In theory the measurement of external radiation dose rate of PET-CT test patients shows that the further the distance from the patient injected with radioactive pharmaceutical and a longer time elapsement from the injection leads to a smaller amount of radiation. Particularly, the amount of radiation marked the highest in the chest was at 4.17 minutes immediately after the intravenous injection and in the head after 77.47 minutes after urination in advance to the PET-CT test. As in the generalized information, it is desired to keep distance between the patient and caretakers or professionals to reduce the amount of radiation exposure from PET-CT test patients and to resume contact the patient after the time when the radiation has reduced. If contact is unavoidable, it is desired to keep at least 200cm from the patient. In addition, the amount of radiation reached the highest in the chest at first and then in the head from 77 minutes after injection. Accordingly, it would be helpful in achieving the optimization if contact is made based on the patient's physical characteristics. This study is significant as it measures changes in radiation the dose rate by; distance from the PET-CT test patient, time elapsed, and specific parts of body. Further studies based on the findings in this paper are required to analyze changes in radiation dose rate in accordance with individual characteristics unique to PET-CT patients and to utilize the results to reduce the amount of radiation patient, caretakers and professions are exposed.

Dose assessment according to Differences in the Content of Iodine in Contrast Media used in Interventional Procedure (중재적 시술에 사용하는 조영제의 요오드(53I) 함유량 차이에 따른 피폭선량 평가)

  • Bak, Hyeok;Jeon, Ju-Seob;Kim, Yong-Wan;Jang, Seong-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.3
    • /
    • pp.337-345
    • /
    • 2014
  • The purpose of this study is to evaluate exposure dose and absorbability according to differences in the content of iodine in contrast media used in interventional procedure and angiography. There were 7 levels of iodine content as 240, 270, 300, 320, 350, 370, and 400 I $mg/m{\ell}$. The higher iodine content was, the more elevated exposure dose and absorbability were. The output dose was about 8.5% from iodine content with 350I $mg/m{\ell}$ higher than that with 270 I $mg/m{\ell}$ in TACE. These results mean that contrast media can have an effect on patient's exposure dose and high iodine content contrast media results in elevation of patient's exposure dose.