• Title/Summary/Keyword: 환자모니터링

Search Result 387, Processing Time 0.03 seconds

Patterns Analysis of Prefrontal Brain Waves of Cancer Patients using Brain-Computer-Interface (뇌-컴퓨터-인터페이스를 이용한 암환자들의 전전두엽 뇌파 분석)

  • Han, Young-Soo;Chae, Myoung-Sin;Park, Pyung-Woon;Park, Chong-Ki
    • Journal of KIISE:Software and Applications
    • /
    • v.35 no.3
    • /
    • pp.169-178
    • /
    • 2008
  • Cancer patients have been suffered from the instability of mind/body and unbalanced homeostasis because of cancer progression and medical treatment such as chemotherapy, It is very important that appropriated actions can be promptly taken by monitoring cancer patients' mental conditions. For this reason, it is crucial to develop a monitoring method which is convenient and not harmful to their body. Brain-computer-interface(BCI) system is introduced for the purpose in this paper. Prefrontal brain waves of cancer patients and control groups have been measured by a portable neurofeedback(NF) system based on self-regulation of the human electroencephalogram(EEG). The NF system consists of the portable EEG amplifier and a headband with dry electrodes placed on Fp1 and Fp2 sites. Patterns of the prefrontal brain waves taken by computer are correlated to brain quotients by EEG-analysis program. Basic rhythm quotient, attention quotient, emotional quotient, anti-stress quotient and correlation quotient of control group have shown high significant level compared with the cancer patients group. On the other hand, the EEG patterns analysis is shown its possibility to be an important methodology of monitoring cancer patients' condition.

A Study on the Development of Sleep Monitoring Smart Wear based on Fiber Sensor for the Management of Sleep Apnea (수면 무호흡증 관리를 위한 섬유센서 기반의 슬립 모니터링 스마트 웨어 개발에 관한 연구)

  • Park, Jin-Hee;Kim, Joo-Yong
    • Science of Emotion and Sensibility
    • /
    • v.22 no.1
    • /
    • pp.89-100
    • /
    • 2019
  • Sleep apnea, a medical condition associated with a variety of complications, is generally monitored by standard sleep polysomnography, which is expensive and uncomfortable. To overcome these limitations, this study proposes an unconstrained wearable monitoring system with stretch-fiber sensors that integrate with the wearer's clothing. The system allows patients to undergo examinations in a familiar environment while minimizing the occurrence of skin allergies caused by adhesive tools. As smart clothing for adult males with sleep apnea, long-sleeved T-shirts embedding fibrous sensors were developed, enabling real-time monitoring of the patients' breathing rate, oxygen saturation, and airflow as sleep apnea diagnostic indicators. The gauge factor was measured as 20.3 in sample 4. The maximum breathing intake, measured during three large breaths, was 2048 ml. the oxygen saturation was measured before and during breath-holding. The oxygen saturation change was 69.45%, showing a minimum measurable oxygen saturation of 70%. After washing the garment, the gauge factor reduced only to 18.0, confirming the durability of the proposed system. The wearable sleep apnea monitoring smart clothes are readily available in the home and can measure three indicators of sleep apnea: respiration rate, breathing flow and oxygen saturation.

Comparative analysis of fusion factors affecting the accuracy of injection amount of remote fluid monitoring system (원격 수액모니터링 시스템의 주입량의 정확도에 영향을 주는 융합인자의 비교 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.3
    • /
    • pp.125-131
    • /
    • 2022
  • Recently, the prevalence of remotely managed patient care systems in medical institutions is increasing due to COVID-19. In particular, in the case of fluid monitoring, hospitals are considering introducing it as a system that can reduce patient safety and nurses' work. There are two products under development: a load cell method that measures weight and a method that detects drops of sap by infrared sensing. Although each product has differences in operation principle, sensor type, size, usage, and price, medical institutions are highly interested in the accuracy of the data obtained.In this study, two prototypes with different sensor methods were manufactured and the total amount of infusion per hour was measured to test the accuracy, which is the core of the infusion monitoring device. In addition, when there was an external movement, the change in the measured value of the sap was tested to evaluate the accuracy according to the measurement method. As a result of the experiment, there was a difference of less than 5% in the measurement value error of the two devices, and the load cell method showed a difference in the low-capacity measurement value and the infrared method in the high-capacity measurement value. As a result of this experiment, there was little difference in accuracy according to the sensor method of the infusion monitoring device, and it is considered that there is no problem in accuracy when used in a medical institution.

A ECG Analysis with Activity Monitrong for Healthcare of Elderly Person (노인 헬스케어를 위한 ECG분석 및 활동량 모니터링 구현)

  • Bhardwaj, Sachin;Purwar, Amit;Lee, Dae-Seok;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.347-350
    • /
    • 2007
  • An ECG analysis with activity monitoring for the home care of elderly persons or patients, using wireless sensors technology was design and implemented. The changes in heart rate occur before, during, or following behavior such as posture changes, walking and running. Therefore, it is often very important to record heart rate along with posture and behavior, for continuously monitoring a patient's cardiovascular regulatory system during their daily life activity. The ECG and accelerometer data are continuously recorded with a built-in automatic alarm detection system, for giving early alarm signals even if the patient is unconscious or unaware of cardiac arrhythmias. The hardware allows data to be transmitted wirelessly from on-body sensors to a base station attached to server PC using IEEE802.15.4. If any abnormality un at server then the alarm condition sends to the doctor' PDA (Personal Digital Assistant).

  • PDF

Design and Implementation of Integrated IEEE802.15.4 Wireless Mobile Care Application (집적형 IEEE 802.15.4 무선 모바일케어 응용시스템의 설계 및 적용)

  • Yau, Chiew-Lian;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.482-485
    • /
    • 2007
  • Recent generation of wireless computing has focus on the integrating of exisitng technologies to enhance the mobile capabilities and developing a new approaches to meet the needs of the growing pool of applications. This paper describes an integrated IEEE802.15.4 wireless CDMA based healthcare system that interacts and received the data wirelessly from wireless medical devices of patient and forward to medical center by using the cellular network. Mobile application had been developed not only as the middle ware to handle the receive and transmit of medical data between wireless sensor network and cellular network but also provides the interface for monitoring and analyzing the health condition of patients continuously at cellular phone regardless of its physical location. This system thus enables the remote healthcare monitoring and supports medical data seamlessly roams between IEEE802.15.4 wireless network and CDMA network beyond and outside the hospital environment.

  • PDF

Design and Implementation of the Web-based Monitoring System for an Artificial Heart (웹 기반 인공심장 모니터링 시스템의 설계와 구현)

  • 정진한;최재순;이지훈;민병구
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.131-137
    • /
    • 2002
  • The remote monitoring system including hemodynamic information and pump status of the implanted animal could be helpful during the in vivo experiment or clinical trial for an artificial heart Implantation. In order to monitor the course of the in vivo experiment continuously and anywhere, web-based remote monitoring system was developed, which can monitor pressures(AoP, LAP, RAP, PAP) and flow information as well as the pump operating conditions. The system consists of data sending, storing viewer part. The data sending part was constructed using component object model and the viewer part was constructed using the Java applet. In addition, the dialog box was introduced to communicate earth other instantly and the alarming function was also introduced when the hemodynamic values were out of the desired ranges. The developed remote monitoring system was applied during the in vivo experiment of the BVAD (Bi-ventricular Assist Device) implantation for 1 month and showed designed work without failure.

Development of ROM Measurement Device capable of IoT-based Real-time Monitoring for Rehabilitation Patients (재활환자를 위한 IoT 기반의 실시간 모니터링이 가능한 ROM 측정 장치 개발)

  • Kang, Min-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.111-116
    • /
    • 2018
  • In this thesis, the range of motion of the joint was measured using a flexible sensor without using a goniometer, and the measured values were transferred to a smart device. Current range of joint motion measurement is measured by a person using a goniometer. Since the method of measuring by a person is different according to the measuring method and position of the measuring person, it is difficult to make consistent measurement, and an error may occur. The sensor for measurement is a flexible sensor that measures the resistance value that changes according to the movement of the joint. The sensed value can be transmitted to the smart device wirelessly through the ROM sensor node. Also, the sensed analog values were converted to digital values using an ADC. The converted value can be transmitted to the smart device wirelessly through the sensor node. The developed ROM measuring device can perform more consistent measurement than the measurement using general articulator and real time monitoring by interlocking with smart device, so that rapid diagnosis according to the movement of the joint can help the patient's rapid treatment and rehabilitation medical advancement will be.

Design of Integrated medical sensor node and Mobile Vital Healthcare diagnosis System (통합형 메디컬센서노드와 모바일 환자생체정보 관리 시스템 설계)

  • Lee, Seung-chul;Gwon, Tae-Ha;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.302-305
    • /
    • 2009
  • The Multiple vital signs management system using Mobil phone is designed with Wireless sensor network and CDMA which are integrated to create a wide coverage to support various environments like inside and outside of hospital. Health signals from medical sensor node are analysed in cell phone first for real time signal analyses and then the abnormal vital signs are sent and save to hospital server for detail signal processing and doctor's diagnosis. We developed integrated vital access processor of sensor node to use selective medical interface(ECG, Blood pressure and sugar module) and control the self-organizing network of sensor nodes in a wireless sensor network. chronic disease such as heart disease and diabetes is able to check using graph view in mobile phone.

  • PDF

A Study on the Development and Testing of Ringer Injection IoT System (링거 주입 IoT 시스템 개발 및 시험에 관한 연구)

  • Cho, Chung-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.4
    • /
    • pp.787-796
    • /
    • 2019
  • In this paper, we propose the design and test measure of Ringer injection IoT system for controling the ringer injection status and notifying the server system of the collected status informations such as the completion of injection, the remaining liquid, the injection status, and the emergency alarming of the urgent patients. We design the circuit diagrams composed of linger injection sensors, switches, status indicators, wireless communication functionalities, and propose the controlling and monitoring algorithms for sensing the linger injection status and notifying the collected status informations to a server system. Furthermore, we derive the testing criteria, such as linger liquid sensing time, sensing distance, operating temperature, input power, power consumption, and wireless communication speed, and analyze the test results.

Design and Error Verification of Intravenous Injection Detection System that Combines Load Cell and Gyro Sensor (로드셀과 자이로센서를 융합한 수액 감지 시스템 설계 및 오차 검증)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.1
    • /
    • pp.127-132
    • /
    • 2021
  • The intravenous injection monitoring system used by medical institutions was developed to remotely provide patients with the amount of intravenous injected and the termination point of the injection. In order to measure the amount of intravenous injection input, the weight or flow rate of the level going out from the inside to outside of the intravenous injection can be observed with a measuring sensor. The criteria for devices that apply herein are accuracy and vigilance. In addition, it is compact and should be easy to use when installing intravenous injection on patients. In medical institutions, the accuracy of the measured values must be high, and economically inexpensive devices are required. In this study, low-cost small-weight-centered load cell sensors were applied, and algorithms were applied to reduce the artefact by external movement by converging with gyro sensors for accuracy of measurements. As a result, it was possible to reduce the error of measurement, thereby improving the accuracy of the intravenous injection monitoring measurement value.