• Title/Summary/Keyword: 환류

Search Result 409, Processing Time 0.024 seconds

Polyphenol Contents and Antioxidant Activity of Lepista nuda (민자주방망이버섯의 폴리페놀 함량과 항산화활성)

  • Lee, Yang-Suk;Joo, Eun-Young;Kim, Nam-Woo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.10
    • /
    • pp.1309-1314
    • /
    • 2006
  • This study analyzed the contents of vitamin C, polyphenol compounds, and evaluated the inhibitory activities against xanthine oxidase and tyrosinase of Lepista nuda extract prepared by the reflux and microwave-assisted methods. The vitamin C content of the fresh L. nude was $9.92{\pm}0.02$ mg/100 g. The content of phenolic compounds in the fresh L. nuda was $1.87{\pm}0.02\;mg/g$. The ethanol extracts prepared by reflux method and microwave-assisted method showed the highest phenol contents of $12.06{\pm}0.12\;mg/g\;and\;11.84{\pm}0.17\;mg/g$, respectively. The inhibitory rates on xanthine oxidase and tyrosinase of ethanol extracts prepared by the microwave assisted method showed the highest value of 99.78% and 30.30% at the concentration of $3,000{\mu}g/mL$. The inhibitory activities on xanthine oxidase and tyrosinase were increased depending on the extract concentration.

A Study on the ZVZCS Three Level DC/DC Converter without Primary Freewheeling Diodes (1차측 환류 다이오드를 제거한 ZVZCS Three Level DC/DC 컨버터에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Baek, Soo-Hyun;Kwon, Soon-Do;Kim, Pil-Soo;Gye, Sang-Bum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.66-73
    • /
    • 2002
  • This paper presents ZVZCS(Zero-Voltage and Zero-Current Switching) Three Level DC/DC Converter without primary freewheeling diodes. The new converter presented in this paper used a phase shirt control with a flying capacitor in the primary side to achieve ZVS for the outer switches. A secondary anxiliary circuit which consists of one small capacitor, two small diodes and one coupled inductor, is added in the secondary to provide ZVZCS conditions to primary switches, ZVS for outer switches and ZCS for inner switches. Many advantages include simple secondary auxiliary circuit topology, high efficiency, and low cost make the new converter attractive for high power applications. Also the circulating current flows through the circuit so that it causes the needless coduction loss to be occurred in the devices and the transformer of the circuit The new converter has no primary auxiliary diodes for freewheeling current. The principle of operation, feature and design considerations are illustrated and verified through the experiment with a 1[㎾] 50[KHz]IGBT based experimental circuit.

Determination the optimum extraction method for saponin lancemasides in Codonopsis lanceolata (더덕 사포닌인 lancemasides의 최적 추출 방법 구명)

  • Lee, Min Ju;Nam, Ju Hee;Um, In Eeok;Kang, Chang Keun;Rho, Il Rae
    • Korean Journal of Food Science and Technology
    • /
    • v.51 no.2
    • /
    • pp.103-108
    • /
    • 2019
  • This study was conducted to select the optimal extraction method of codonopsis lanceolata saponin. To investigate the lancemasides content depending on each extraction method, various extractions were performed: reflux (methanol and butanol), hot water, as well as ultrasonic bath (40 kHz; continuous irradiation/interval irradiation) and ultrasonicator (20 kHz) extractions. From the result, the overall lancemasides content were the highest in ultrasonic bath (MeOH; continuous irradiation) extraction, followed by ultrasonic bath (water; continuous irradiation)>ultrasonic bath (MeOH; interval irradiation)>ultrasonicator (MeOH)>hot water>MeOH reflux>BuOH reflux extractions in that order. Sample drying method prior to ultrasonic bath extraction was more effective shade drying than freeze drying. Effective duration and temperature of extraction was 2 hr at $64^{\circ}C$. And ingredient change diverted from aster saponin Hb to lancemasides was identified by extraction condition such as extraction time and temperature.

3상 Thyristor Inverter동작 Mode의 Vector해석법 1

  • 황영문
    • 전기의세계
    • /
    • v.23 no.4
    • /
    • pp.32-35
    • /
    • 1974
  • Thyristor inverter의 유형은 Switching기능에 따라 분류하고 있는데, 크게 나누어 Bridge형 converter와 Cycloconverter로 나누는데, 여기서는 이중 3상 Bridge형 Thyristor Inverter에 대한 전력변환과정을 Vector해석법에 의하여 그 개요를 설명하고, 여기에 현재 가장 효율적 switching방식이라 보고 있는 펼스폭변조환류게이트방식(Pulsewidth modulation commutation gating system)을 적용하였을 때의 효과를 첨가 설명코자 한다.

  • PDF

DC-DC콘버어터의 해석법

  • 김희준
    • 전기의세계
    • /
    • v.36 no.9
    • /
    • pp.665-672
    • /
    • 1987
  • 본고에서는 상태평균화법의 일반적인 성질을 설명하고, 여러종류의 콘버어터회로중 가장 안정성에 뛰어난 전류환류형회로에 적용시킴으로서 그 기본특성을 명확히 하며, 이 외에 강압형, 승압형, 승강압형의 전형적인 회로에 적용시킨 결과를 정리하여 명시하고 비교고찰함으로서 상태평균화법이 통일적인 해석에 적합한 해석법이란 점을 기술하였다.

  • PDF

Changes of Total Polyphenol Content and Antioxidant Activity of Ligularia fischeri Extracts with Different Microwave-Assisted Extraction Conditions (마이크로웨이브 추출조건에 따른 곰취 추출물의 총 폴리페놀 함량 및 항산화작용의 변화)

  • 권영주;김공환;김현구
    • Food Science and Preservation
    • /
    • v.9 no.3
    • /
    • pp.332-337
    • /
    • 2002
  • This study was undertaken in order to compare reflux extraction(RE) and microwave-assisted extraction(MAE) in extraction efficiency and establish optimum microwave extraction conditions in obtaining Ligularia fischeri extracts. A considerable reduction in extraction time was accomplished by MAE. When 70% methanol 50% methanol 70% ethanol, or 50% ethanol was used, MAE extract contained equal levels of soluble solid and total polyphenol as obtained by RE. The optimum microwave-assisted extraction conditions for Ligularia fischeri were achieved by 120∼150 watts of microwave energy and 4∼8 minutes of extraction time. No significant changes were found in antioxidant activity with DPPH scavenging method over the variation of microwave energy or extraction time. The use of diluted methanol or ethanol improved soluble solid content(30%), total polyphenol content(2.7%) and antioxidant activity(68%).

Double-Ended Active Clamp Full Bridge DC/DC Converter (Double-Ended 능동 클램프 풀 브리지 DC/DC 컨버터)

  • Shin, Yong-Saeng;Jang, Young-Su;Roh, Chung-Wook;Hong, Sung-Soo;Kim, Dong-Joong;Kim, Hak-Yong;Kim, Don-Sik;Lee, Hyo-Bum;Han, Sang-Kyoo
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.394-396
    • /
    • 2008
  • 기존 위상천이 풀 브리지 컨버터의 경우 구조가 간단하고, 모든 스위치의 영전압 스위칭 동작이 가능하기 때문에 고전압/대전력용으로 널리 사용되고 있다. 그러나 위상천이 풀 브리지 컨버터의 경우 환류구간동안 입력 에너지가 출력으로 전달되지 못하고 순환하므로 도통손실이 큰 단점이 있다. 따라서 본 논문에서는 환류구간이 존재하지 않으며, 출력인덕터 전류 리플을 최소화 할 수 있어 대전류 시스템에 매우 적합한 새로운 Double Ended 능동 클램프 풀 브리지 DC/DC 컨버터를 제안한다. 최종적으로 제안된 회로의 정상상태 동작에 관하여 이론적으로 분석하고, Psim 모의실험을 수행하며, 실제로 1.2KW급 서버용 전원장치에 적용하여 타당성을 검증한다.

  • PDF

ZCS-PWM Boost Converter Dropped Voltage and Current Stress of a Free-Wheeling Diode (환류 다이오드의 전압, 전류스트레스가 강하된 ZCS-PWM Boost Converter)

  • Kim, Myung-O;Kim, Young-Seok;Lee, Gun-Haeng
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.11
    • /
    • pp.540-546
    • /
    • 2005
  • This paper presents a boost circuit topology driving in high - frequency It solves the problem which arised from hard-switching in high-frequency using a period of resonant circuit and operating under the principle of ZCS turn-on and ZCZVS turn-off commutation schemes. In the existing circuit, it has the high voltage and current stress in free- wheeling diode. But in the proposed circuit, it has voltage and current stress which is lower than voltage and current stress of existing circuit with modifing a location of free-wheeling diode. In this paper, it explained the circuit operation of each mode and the waveform of each mode. Also the experiment results compare the voltage and current stress of free-wheeling diode in the existing circuit with the voltage and current stress of that in the proposed circuit. Moreover, it compares and analyzes the proposed circuit's efficiency with the existing circuit's efficiency according to the change of load current.

Pulmonary Thromboendanterectomy of Chronic Pulmonary Thromboembol ism -A case Report- (만성 폐색전증의 색전제거술 -치험 1례 보고-)

  • 신윤철;지현근
    • Journal of Chest Surgery
    • /
    • v.29 no.5
    • /
    • pp.569-572
    • /
    • 1996
  • A sixty nine-year-old mate patient was admitted with a chief complaint of exertional dyspnea. Lung perfusion scan revealed total perfusion defect of the of left lung and CT anglography showed the ab- rupt cutoff left pulmonary artery. He denied of trauma history, previous lower leg symptom and sign, or any embolic history. With the impression of chronic pulmonary thromboembolism of unknown etiology, operation was done under the cardiopulmonary bypass through a median sternotomy. After main pulmonary artery clamping and pulmonary arteriotomy, thromboembolectomy was done. Postoperative lung perfusion scan and CT angiography showed near normal left pulmonary blood flow. The patient was discharged on the postoperative 9th day without any postoperative complication.

  • PDF