Study on Modification of Inside Environment in Windowless Weaning Piglet House (무창이유자돈사의 내부 환경 개선에 관한 연구)

  • Lee, Seung-Joo;Gutierrez, W.M.;Kim, Bong-Sik;Han, Jin-Young;Chang, Dong-Il;Chang, Hong-Hee
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.2
    • /
    • pp.150-155
    • /
    • 2008
  • This study was carried out to determinate the location and the number of air inlet and outlet, optimum air inlet velocity for effective ventilation in windowless weaning piglet house($2.90(W){\times}9.90(L){\times}2.80(H)$ m) by CFD(Computation Fluid Dynamics) simulation. The weaning piglet house for this experiment was consisted of 11 air inlets and 9 outlets, modified and simulated using CFD code, FLUENT. The simulation result for the original weaning piglet house, which was not modified, showed ununiform ventilation for each room. Therefore, for uniform ventilation, 4 air inlets and 1 outlet were completely closed, and 2 air outlets were partially closed. The simulation result for the modified weaning piglet house showed uniform ventilation for each room and the optimum air inlet velocity of 0.5 $m\;sec^{-1}$.

A study on applications of the natural ventilation pressure(NVP) in local tunnels (터널내 자연환기력(NVP) 적용방안 연구)

  • Kim, Hyo-Gyu;Yoo, Ji-Oh;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.3
    • /
    • pp.269-285
    • /
    • 2014
  • In spite of the importance of the natural ventilation pressure(NVP) in tunnels for the optimal design of the ventilation system, there have been only few studies on the NVP because its measurement and quantitative analysis are not straightforward. This study aims at quantifying the amount of the NVP with the terrain and meteorological data for the local major tunnels. And ultimately this will lead to developing the guidelines for quantifying and applying NVP for the optimal design of tunnel ventilation system. 22 local tunnels in the major routes are studied for the NVP quantification. NVP derived from the meteorological data is in the range of 20~140 Pa, while NVP estimated from the terrain data ranges from 20 to 200 Pa. Since the jet fan pressure is about 10~15 Pa per unit, the minimum level of NVP expected in the local tunnels is larger than the pressure rise by one unit of the ordinary jet fan. This implies that NVP in local tunnels should be quantified and be taken into consideration for the economic and safe ventilation design. The barometric pressure difference between tunnel portals is found to be the most influential factor, accounting for 61% of the NVP, while the wind pressure acting on the portals and the chimney effects occupy 22% and 17%, respectively.

ICT Fusion Type Plasma Waste Heat Ventilation System for Improvement of Indoor Air Quality (실내 공기질 개선을 위한 ICT 융복합형 플라즈마 폐열 환기 시스템)

  • Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1215-1220
    • /
    • 2019
  • Currently, each farm bears both the outbreak of foot-and-mouth disease and the damage caused by AI. In addition, complaints about odors in the livestock industry are constantly being recovered and are expected to occur in the future. The purpose of this study is to improve the indoor air quality of enclosed facilities such as barns, houses, pigsty, and etc. This paper develops low-temperature plasma waste heat ventilation system to be installed in ventilation unit location and standardizes heat exchange element, low-temperature plasma lamp, and ballast for enhanced air cleaning function. In addition, this study intends to develop a new control system so that the farmers can connect with existing weather systems, flow fans, and other facility equipment by incorporating ICT.

A Study on Three-Dimensional Flow Analysis and Noise Source of Sirocco Fan (시로코 팬의 3차원 유동해석 및 소음원에 관한 연구)

  • Kang, Jeong-Seok;Kim, Jin-Taek;Lee, Cheol-Hyung;Baek, Byung-Joon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.896-902
    • /
    • 2018
  • This study examined the flow and noise inside a sirocco fan for ventilation as a commercial program. To confirm only the location and power of the noise source, flow analysis was performed with steady state flow analysis. Through flow analysis, the flow was observed in the sirocco fan and the velocity vector. The pressure distribution inside was observed with contours. From the results of steady analysis, the position and size of the noise source could be seen using the 'Curle surface acoustic power' and 'Proudman acoustic power'. The Curle surface acoustic power can be used to observe the noise from the surface. The Proudman acoustic power can be used to detect noise generated in the flow region because the position and size of the noise source generated inside the sirocco fan can be seen only in the steady state. Therefore it is necessary to further analyze the unsteady state to check the frequency of the noise generated. This study provides basic data for improving the performance of the Sirocco fan and reducing the noise.

Investigate on the rate of change of CO concentration in a tunnel under changed position of the jet fans by using numerical method (제트 팬 가동위치에 따른 장대터널 내 CO 농도 변화율에 대한 전산해석)

  • Min, Jae-Hong;Kim, Dae-Hyun;Chung, Jin-Taek
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2765-2770
    • /
    • 2008
  • The purpose of tunnel ventilation system for long road tunnels is to keep certain levels of Visibility Index and the concentration of CO. Additional equipments such as jet fans are used in road tunnel to discharge pollutants in the road tunnel. The control algorism of tunnel ventilation system takes the value of sensors as input, and then gives the operation method of jet fans in tunnel as output. Information on the variation of CO concentration in tunnel when jet fans are running is needed to minimize their operation time. Numerical analysis is used in this paper because of the difficulty of conducting experiments under standard condition for ventilation of road tunnel. The concentration of CO has been calculated by using 3-dimensional CFD under transient condition with speed of cars, quantity of air ventilation, and the results for various operation position of jet fans are compared.

  • PDF

A Numerical Analysis on the Airflow Characteristics in Super Cleanrooms with Different Design Types (초청정 클린룸 공조방식에 따른 기류특성에 관한 수치해석)

  • 노광철;이승철;오명도
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.751-761
    • /
    • 2003
  • We performed the numerical analysis on the airflow characteristics in the two type of cleanroom systems, which are the axial fan type (AFT) and the fan filter unit (FFU). A computational fluid dynamic model was applied to investigate and compare the nonuniformity, the deflection angle and the air ventilation effectiveness of the two designs of cleanrooms when dampers are adjusted and not adjusted. And the flow-resistance models of the various components were used in this simulation. We know that the airflow characteristics of the cleanrooms are largely affected by damper adjusting And we also find out that the FFU system is superior to the AFT system through the comparison of the cleanroom performance indices.

Survey of ICT Apply to Plastic Greenhouse, Rack·Pinion Adaption to Single Span and CFD Analysis (온실 ICT융복합 실태조사와 복숭아형 랙피니언천창 적용 단동온실 및 CFD 유동해석)

  • Cho, Kyu Jeong;Kim, Ki Young;Yang, Won Mo
    • Journal of Bio-Environment Control
    • /
    • v.24 no.4
    • /
    • pp.308-316
    • /
    • 2015
  • This study was conducted to investigate the situation of ICT apply to plastic greenhouse, and the results be apply to design of new one. A CFD analysis were conducted to monitering the ventilation and energy saving of the single span greenhouse newly designed. The causes of delay to apply ICT to plastic greenhouse are the high cost for installation(24%), insufficiency of after services(19%), often disorder(16%), unskillful management of soft ware(15%), insufficient ICT efficiency(13%) and unsatisfying of income increase(12%). The parts of problem occurred in ICT plastic greenhouse are the structure, actuator, environmental control system and sensor(approximate 14%, respectively), remote control technique(13%), plant management technique(12%), energy saving technique(10%) and utilization of software(8%). In the condition of lateral window closed, the average wind speed changed to slow, but it was faster in the condition of leeward side window opened than in the condition of lee and winward side window opened. The air movement in the condition of lateral window closed occur by air moving fan not by out air. It is not affect the room temperature but effective the uniformity of room temperature. The average temperature of low height greenhouse was uniform than high height one. The average temperature in condition of 3rd curtain opened become same with outside temperature after 2 hours, but take more 5 hours in condition of 3rd curtain closed.

A Study on Estimation of Ventilation Performance in the Underground Parking Lot (지하 주차장의 환기성능평가에 관한 연구)

  • Hwang, Min-Kyu;Kim, Seong-Sik;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.71-77
    • /
    • 2007
  • In past, parking lot was placed on the ground and for the reason air quality was not in problem. But recently parking lot has been placed under the ground and the air quality becomes problem. So in this study, the ventilation performance on the underground parking lot was estimated by using CFD software and alternative system was suggested. Three case studies are handled in this study. 1st case is just an underground parking lot. 2nd case is about an underground parking lot where has 4 fan rooms on each floor and 3rd case is about an underground parking lot where has 4 fan rooms and 30 guidance fans on each floor.

VENTILATION DESIGN OF UNDERGROUND PARKING AREA IN A NEW BUILDING USING CFD (CFD를 이용한 신축건물 내 지하주차장의 환기설계)

  • Kim, J.H.;Yang, S.Y.;Lee, G.T.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.04a
    • /
    • pp.59-63
    • /
    • 2007
  • With the recent increasing demand on the high-performance buildings, there has been a rapid growth in the application of the Computational Fluid Dynamics to the Building design. The conceptual ventilation design of the underground parking area currently under construction is validated using the CFD-ACE+. It has been found that the conceptual ventilation design quantitively satisfies the legal standards. However, the highly concentrated region of CO is predicted. The positions and blowing directions of ventilating lane are changed based on the previously predicted concentration distributions. The highly concentrated region of CO is slightly reduced, but not much change has been observed. Two more fang are installed and the positions and blowing directions of the fans are modified so that the highly concentrated region of CO is minimized.

  • PDF

An Examination on Cooling Effects According to Water Spray, Top and Side Windows, and Operation of Pan of Single Span Plastic Greenhouses (Part 2) (단동 플라스틱 하우스의 관수, 천.측창 개폐 및 환기팬 조작에 따른 냉각효과 검토 (제2편))

  • 최동호;허종철;임종환;서효덕
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1999.11a
    • /
    • pp.55-58
    • /
    • 1999
  • 1. 스프링클러에 의해 하우스내를 관수한 경우, 하우스내 온도는 스프링클러 작동과 동시에 급격히 하강한 후 시간이 흐름에 따라 완만한 하향구배를 나타내었다. 2. 천 측창을 개방한 상태에서 스프링클러에 의한 냉각효과를 측정한 결과, 실내기준온도는 외기온 보다 약 2.8$^{\circ}C$ 낮은 온도를 나타내었다. 3. 본 실험결과 스프링클러 관수에 의한 냉각효과는 탁월한 것으로 조사되었으며, 관수시간대를 비교적 실온이 상승하는 주간시간대로 설정한다면, 그 효과를 극대화 할 수 있을 것으로 사료된다. 이 경우, 관수시의 수량 및 관수 지속시간 등에 대해서는 재배작물의 습해 등을 고려하여 이에 대한 면밀한 검토가 이루어져야 할 것으로 판단된다.

  • PDF