• Title/Summary/Keyword: 환기탑

Search Result 20, Processing Time 0.034 seconds

Case studies related to the installation of tunnel ventilation towers (터널 환기탑 국내·외 설치사례연구)

  • Park, Jun Kyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.3
    • /
    • pp.293-304
    • /
    • 2022
  • Recently, the frequency of installation of ventilation towers is increasing due to the planning and construction of underground roads and long tunnel. In this study, implications and points for improvement were considered through investigation and analysis of the installation standards related to ventilation towers in tunnels and analysis of ventilation tower installation cases in domestic and overseas tunnel case study. As a result of this study, when selecting the location and height of the ventilation tower, it is recommended to determine the final ventilation tower type through a consultation process with residents, considering the environmental impact caused by the emission of pollutants, the harmonious arrangement with the surrounding landscape, and the efficient use of the above-ground site nearby ventilation tower. In addition, from the design stage, it is judged that a detailed review of reducing the height of the ventilation tower through air quality simulation is necessary for natural harmony with the surrounding topography and to prevent civil complaints.

Classification and Applications of Direct Contact Condensation Heat Exchanger (직접접촉응축 열교환기의 분류 및 응용)

  • 오후규;김성규
    • Journal of the KSME
    • /
    • v.35 no.7
    • /
    • pp.638-646
    • /
    • 1995
  • 직접접촉 얼교환 기술은 냉각탑, 접촉급수 가열기 및 공기분리기 등과 같은 장치에 예전부터 이용되어 왔는데, 그 주요한 적용이유는 가열유체와 수열유체의 사이에 일어나는 전열이 일반 열교환기와는 달리 고체벽(금속 열전달표면)을 통과하지 않고 열교환을 함으로써, 종래의 열교 환기에 비하여 상대적으로 설비의 간단화, 부식 및 스케일 부착문제가 경감됨에 따른 적은 유 지보수비 및 높은 열전달률을 얻을수 있는 이점이 있으며, 저 온도차에서의 효율적인 사용이 가능하기 때문이다. 이 글에서는 직접접촉응축 현상의 장점을 이용하는 직접접촉식 교환기의 구조와 형태, 그리고 그 응용분야에 대해서 알아보고자 한다.

  • PDF

A Note on Direct Contact Exchangers (직접방식 열교환기와 전달특성)

  • 김석현
    • Journal of the KSME
    • /
    • v.35 no.9
    • /
    • pp.829-835
    • /
    • 1995
  • 통상의 열교환기에서 전열면이 제거된 형태의 직접열교환을 통하여 제작비나 열전달 특성에 큰 효과를 얻을 수도 있어 에너지이용 합리화에 기여하는 특성과 사례를 언급하였다. 또한 통상의 열교환기 설계와 다른 매질간의 공유계면에서 발생 가능한 전달특성을 위주로 설계상의 일부 유의사항을 기술하였다. 직접열교환의 기술축적은 상변화를 동반하는 열전달(two phase heat transfer) 문제의 기초지식은 물론, 염수플랜트(desalination)의 기본 요소설계, 원자로의 냉각계 통사고(LOCD)대책, 기타 냉각탑, 탱크가열, 증발기(evaporator), 건조장치(drier), 각종 기계, 화공 공정장치 설계 등 매우 광범위한 기술파급 효과도 기대할 수 있으므로 관련 기술자들의 많은 관심을 기대한다.

  • PDF

Modification of GGH Leakage Evaluation Equations in Wet FGD System (습식 배연탈황공정에서 GGH 누설률 평가식의 수정)

  • 천성남;안영모;장경룡
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.387-388
    • /
    • 2003
  • 습식 배연탈황 공정에서는 흡수탑 내에서의 황산화물 흡수율을 높일 목적으로 흡수탑으로 유입되는 배기가스를 약 5$0^{\circ}C$까지 냉각하고, 처리된 배기가스는 연돌에서의 자연 통풍력을 확보하고 연돌 배출 후 수분의 응축으로 인한 백연(white Plume)의 문제를 방지하고자 통상 9$0^{\circ}C$ 이상으로 가온하는 것이 일반적이며 이를 위해 다양한 형식의 열교환기가 설치 운영되고 있다. 탈황공정에서 흔히 GGH(gas to gas heater)라 불리는 Ljungstrom 방식의 열 교환기는 미처리된 고온가스와 처리된 저온 가스가 회전하는 열교환소자로 이루어진 영역을 지나면서 열 교환이 이루어지는 형태로 회전 부위 및 두 가스흐름의 구분 판(sector plate) 등에서 필연적으로 처리가스 흐름 중으로 미처리 가스의 누입이 일어나게 된다. (중략)

  • PDF

A Numerical Study on the Performance Analysis of Plume Abatement Cooling Tower with Dry Type Heat Exchanger (건식 열교환기를 이용한 백연방지 냉각탑 성능의 수치해석적 연구)

  • 김병조;최영기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1018-1027
    • /
    • 2003
  • This study treats the analysis of the performance and the design of plume abatement wet/dry cooling tower with dry type heat exchanger using a numerical method. A two-dimensional analysis is performed using the finite volume method for mechanical draft counterflow and crossflow tower. For a coupling problem between water and air system, a turbulent two phase flow is considered. Effectiveness-NTU method is used for modeling of the dry type heat exchanger. The parameter change simulations of the outer wall shape, the relative flowrate of air, and attachment of an air mixer are performed to examine the effect on plume abatement. It is found that if the relative air flowrate ratio and the adequate air mixer type are chosen well in addition to the ratio of water to air flowrate, the loss of the cooling capacity and the additional cost are reduced and the plume is abated.

Comparison of age of air and air change effectiveness between supply diffuser types (공조취출방식에 따른 공기의 나이 및 환기효율 비교)

  • Cho, D.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.117-124
    • /
    • 1999
  • In this study, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The measurements on the age of air and the air change effectiveness using the tracer gas method are carried out to analyze the ventilation performance for provision of fresh air between the diffusers. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The measured local air change effectiveness of the desktop diffuser in the breathing zone was usually 1.13 to 1.23 times greater than that of ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

A Study on the Factors of affecting the Heat Exchanger for Closed Cooling Tower (밀폐형 냉각탑용 열교환기의 성능에 영향을 미치는 인자에 관한연구)

  • Lee, Sang-Sik;Yoo, Seong-Yeon;Kim, Jin-Hyuck;Ryu, Hae-Sung;Park, Hyoung-Joon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.250-255
    • /
    • 2008
  • Most high-rise building and large building require a cooling tower. Closed cooling tower is a low noise and the high efficiency. also Closed cooling tower is available for four season. Performance of Closed cooling tower is judged by heat transfer coefficient. In this study, Heat transfer coefficient is compared with air velocity, spray flow, heat exchanger type.

  • PDF

Improved Operability in a Fully Thermally Coupled Distillation Column with an Intermediate Heat Exchanger (중간 열교환기를 이용한 열복합 증류탑의 운전성 향상)

  • Jeong, Su-Yeong;Kim, Young-Han
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.9
    • /
    • pp.945-953
    • /
    • 2006
  • Though a fully thermally coupled distillation column consumes less energy than an original column, it is not widely implemented in practice due to its operational difficulty. A new fully thermally coupled distillation column is proposed for the operability improvement, and its performance is investigated. The main improvement is the separation of a main column to give an upper and lower columns and the installation of an intermediate heat exchanger between them to regulate the fluctuation of product compositions. A proper manipulation of column pressure in the separated main columns made easy vapor flow without a compressor. The operability improvement is examined in a hexane process from the dynamic simulation using a commercial design software HYSYS. The simulation results indicate that the coupling among inputs and outputs is loosened to make easy manipulation of product compositions in the proposed distillation system.

Estimation of Indoor Environment using CFD of Multi-Purpose System with a Solar Collector -Part 1, focused on floor area and number of ventilation- (태양열온수기 적용 냉난방시스템의 CFD를 이용한 실내환경 평가 -제1보 바닥면적과 환기횟수를 중심으로-)

  • Kim, Jong-Ryeol;Choi, Kyang-Hyan
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.55-61
    • /
    • 2007
  • This paper has been conducted to estimate cooling capacity of the dehumidification tower using hot water from a solar water heating system as a energy source of regeneration process when the dehumidification and drying system is applied to room cooling. A solar water heating system was operated and indoor temperature distributions were simulated according to weather conditions when the concerned solution was used to dehumidify room air in the dehumidification tower. Through this simulation researches we found th following results ; It was found that air velocity through supply and return diffusers should be controlled because it can cause uncomfort in dwelling area. It was found that in the sunny morning temperatures of dwelling area 1 and 2 are higher than those of dwelling area 3 and 4. In this research all the calculation results of heating and cooling system supported by solar water heater have confirmed that its cooling capacity could not reach PMV 0, thermal comfort.