A Study on the Discrimination of Fire Pattern by the Phenomenological Observation (Focused on the Fire Cases) (현상학적 관찰에 의한 연소패턴의 식별에 관한 연구(사례를 중심으로))

  • Choi, Don-Mook;Choi, Sung-Bok;Choi, Jae-Soung
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.98-110
    • /
    • 2009
  • The burned patterns of fire are changed very diversely according to the direction of wind, conditions of combustibles, shape of buildings and so on in the fire scenes. And careful attentions are required on the determining of ignition point and fire causes. In this study, we examined that the burned pattern of fuel controlled fires and ventilation controled fires that impose a heavy burden on fire investigators, carbonized marks of floor, formed by flammable liquids, and combustion marks of falling firing materials through the fire cases. We suggest a proper fire investigation method.

Simulation & Validation of Lubricating Oil Fire in Nuclear Power Plant Pump Room (원전 펌프실 윤활유화재 분석 및 확인에 관한 연구)

  • Park, Jong-Seuk;Park, Yoon-Jeong;Lee, Chang-Joo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.241-245
    • /
    • 2010
  • 화재방호에 성능기반 개념을 도입함에 따라 화재모델링의 활용도는 점점 높아지고 있다. 본 연구의 목적은 FDS를 이용하여 원자력발전소 펌프실의 윤활유 화재 시 케이블의 손상여부를 평가하고, 확인분석을 통해 화재모델링의 적합성을 파악하는 데 있다. 화재는 펌프 주변의 누출된 윤활유에서 발생하며 화원의 면적은 $2.75m^2$이고 단위면적당 열방출율은 $1,794kW/m^2$로 가정하였다. 계산결과, 고온기체층의 온도는 $400^{\circ}C$를 상회하고 있으나 케이블 트레이의 온도는 $50^{\circ}C$ 아래로 예측되고 있어 본 화재시나리오에서 케이블의 건전성은 유지되고 있으며 밀폐된 격실에서의 대형화재는 환기지배형 화재가 된다는 것을 보여주고 있다. 또한 확인분석 결과, 화재 시나리오의 주요 변수인 열방출율, 격실크기 그리고 강제 환기 변수가 확인계산 범위 내에 있어 본 계산결과는 NUREG-1824의 확인요건을 만족하고 있다. 따라서 펌프실 윤활유 화재에 대한 모델링의 적합성을 확인하였다.

  • PDF

Effect of the Characteristic Length Scale on the Grid Dependency of FDS model (특성길이에 따른 FDS 모델의 격자 의존성)

  • Kim, Sung-Chan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.66-69
    • /
    • 2012
  • Field Model에 의한 화재해석방법은 화재현상을 지배하는 망정식윤 직접 해석하기 때문에 Zone model에 비해 공간내의 상세 정보를 제공함과 동시에 다양한 화재형태에 내해 보편적인 적용이 가능하다. Field model은 해석영역을 구성하는 격자점에 대해 이산화된 지배 방정식을 해석하는 과정에서 차분방법이나 격자의 크기에 따라 수치오류가 발생할 수 있다. 특히 격자수는 계산시간에 영향을 미치는 가장 중요한 인자이기 때문에 효율적인 계산을 위해서는 격자크기의 최적화가 이루어져야 한다. 본 연구에서는 구획공간 화재의 최적 격자크기 선정을 위해 격자해상도(Grid Resolution)에 따른 해석결과의 독립성을 비교분석하고 이를 통해 구획공간화재에 대한 격자 최적화 방법에 대해 논의하고자 한다. 화재크기 및 특성 길이에 따른 격자의존성을 파악하기 위해 ISO-9705 표준화재실에 내해 적용된 격자크기는 최소 3 cm에서 최대 30 cm까지 총 7 종류의 격자크기에 대해 FDS 해석이 수행되었다. 해석결과, 환기량이 충분한 화재에 대해서도 격자해상도가 16보다 작은 경우 출입구의 유동은 격자에 따른 독립성을 확보하지 못하는 것으로 나타났으며 화재발열량이 증가함에 따라 독립적인 해석해를 얻기 위해서는 더 큰 격자해상도를 요구하는 것으로 나타났다. 따라서 현재 실무에서 격자최적화를 위해 사용되고 있는 격자선정법에 대한 재검토가 필요하며 화재특성 및 구획공간 조건에 따른 최적격자 조건을 도출하기 위한 추가적인 연구가 필요하다.

  • PDF

Thermal Characteristics of Under Ventilated Compartment Fire (환기부족 구획화재의 열적 특성)

  • Kim, Sung-Chan;Hamins, Anthony
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.41-48
    • /
    • 2009
  • The present study has been performed to investigate the thermal characteristics of under-ventilated compartment fire which is a typical fire condition in structures. A series of fire experiments was conducted to characterize the thermally driven flow in a 2/5 scale ISO 9705 fire compartment. Three different fuels were used in this test series, methane gas, heptane pool, and polystyrene pellets fire. In order to measure accurate temperature, double shield aspirated thermocouples reducing the effect of radiative energy exchange on temperature measurement were used in addition to bare bead thermocouples. The upper layer temperature for well ventilated fire was increased with increasing heat release rate, but it was slightly decreased for under-ventilated fire. The measured temperatures in the upper layer at the front sampling location were higher than at the rear. Thermal characteristics through the doorway were also analysed for a wide range of heat release rates. This study provides a comprehensive and quantitative assessment of fire behavior for under-ventilation condition of fire.

CCDP Evaluation of the Eire Area of NPPs Using Eire Model CEAST (화재모델 CFAST를 이용한 원전 화재구역의 CCDP평가)

  • Lee Yoon-Hwan;Yang Joon-Eon;Kim Jong-Hoon;Noh Sam-Kyu
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.64-71
    • /
    • 2004
  • This paper describes the result of the pump room fire analysis of the nuclear power plant using CFAST fire modeling code developed by NIST. The sensitivity studies are performed over the input parameters of CFAST: the constrained or unconstrained fire, Lower Oxygen Limit (LOL), Radiative Fraction (RF), and the opening ratio of the fire doors. According to the results, a pump room fire is the ventilation-controlled fire, so it is adequate that the value of LOL is 10% which is also the default value. It is anlayzed that the Radiative Fraction does not affect the temperature of the upper gas layer. It is appeared that the integrity of the cable located at the upper layer is maintained except for the safety pump at the fire area and the Conditional Core Damage Probability (CCDP) is 9.25E-07. It seems that CCDP result is more realistic and less uncertain than that of Fire Hazard Analysis (FHA).