• Title/Summary/Keyword: 환기설계

Search Result 609, Processing Time 0.024 seconds

A Study of th Optimum of closed ${CO}_{2}$ Gas Turbine Process for Nuclear Energy Power Plant(II) - For Optimal Design of Heat Exchanger- (원자력 발전소에 대한 밀폐 ${CO}_{2}$ 가스터빈 프로세스의 최적화 연구 (II) -열교환기의 설계에 관하여 -)

  • 이찬규;이종원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.251-258
    • /
    • 1990
  • Optimal design of heat exchanger for closed CO$_{2}$ gas turbine plant of three processes selected from the result of cycle analysis have been discussed previously paper(I) has been carried out under specified inlet and outlet conditions. Independent variables such as number of parallel connection, tube diameter, shell side and tube side pressure loss as well as dependent variables such as shell diameter, number of tubes, number of serial connections were all characterized according to the standardization or so. Search method was used to construct a computer simulation together with the calculation of heat transfer rate by logarithmic mean temperature difference method. Strength analysis of major parts was carried to examine their dimensions satisfying heat transfer and pressure loss requirements.

A Study on the Airflow Distribution in the Diagonal Ventilation Circuit for the Design of a High Level Radioactive Waste Repository (고준위 방사성 폐기물 처분장 설계를 위한 Diagonal 환기 회로 내 공기량 분배에 관한 연구)

  • Hwang, In-Phil;Choi, Heui-Joo;Roh, Jang-Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.22 no.3
    • /
    • pp.173-180
    • /
    • 2012
  • In this study, diagonal ventilation circuits that are advantageous in air flow direction control were studied. Based on the results of the study, it could be seen that air volumes in diagonal ventilation circuits could also be calculated using numerical formulas or programs if the air volumes and air flow directions to be infused into diagonal branches are determined in advance as with other serial/parallel circuits. To apply the results, design plans for high level radioactive waste repositories applied with diagonal ventilation circuits and parallel ventilation circuits. To compared the each design plans and obtain expected operation results, ventilation network simulations were conducted through the Ventsim program which is a ventilation networking program. Based on the results, in the case of diagonal repositories that was expected to cause great increases in resistance, fan pressure was 1570 pa, total flux was 84 $m^3/s$, fan efficiency was 76.4%, fan power consumption was 181.2 kW and annual fan operating costs were 178,710,838 and thus maximum around 8% differences were shown in pressure and flux values and a difference of around 1.5% was shown in terms of operating costs.

도로터널 환기시설 T.A.B.(제트팬 방식)

  • 유지오
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.30 no.7
    • /
    • pp.24-28
    • /
    • 2001
  • 터널 환기 설비는 터널에서 발생하는 오염물질을 희석 배출하여 터널에서의 안전운행 및 쾌적한 환경을 유지함을 목적으로 한다. 이를 위해서 각종 환기설비가 필요하게 되며, 이에 대한 설계 검토가 요구되고 있다. 본 원고에서는 제트팬 방식의 터널에서 풍속 측정을 중심으로 하여 측정결과 및 분석결과를 소개하고자 한다.

  • PDF

The Study on Optimum Ventilation System during Long Tunnel Construction (굴착중인 장대터널내 최적의 환기시스템에 대한 연구)

  • Oh, Byung-Hwa;Lim, Han-Uk
    • Explosives and Blasting
    • /
    • v.24 no.2
    • /
    • pp.9-22
    • /
    • 2006
  • In general, tunnel construction except for special cases such as very short tunnels must require an artificial ventilation system. Especially, it is efficient for long tunnels to use the combination of a proper ventilation system according to the progress of the excavation. Neung-Dong Tunnel of which length is 4,580m has been originally designed as using ventilation system of blower and exhaust mixture types. Since it has been expected to result in some problems, its design Is analyzed to find the way to improve ventilation system by estimating the amount of required fresh air, considering various ventilation mixture types, ventilation's fluidity analysis and contaminant's distribution by numerical analysis. Economical efficiency for each type is also reviewed to determine the best ventilation system.

A Note on Direct Contact Exchangers (직접방식 열교환기와 전달특성)

  • 김석현
    • Journal of the KSME
    • /
    • v.35 no.9
    • /
    • pp.829-835
    • /
    • 1995
  • 통상의 열교환기에서 전열면이 제거된 형태의 직접열교환을 통하여 제작비나 열전달 특성에 큰 효과를 얻을 수도 있어 에너지이용 합리화에 기여하는 특성과 사례를 언급하였다. 또한 통상의 열교환기 설계와 다른 매질간의 공유계면에서 발생 가능한 전달특성을 위주로 설계상의 일부 유의사항을 기술하였다. 직접열교환의 기술축적은 상변화를 동반하는 열전달(two phase heat transfer) 문제의 기초지식은 물론, 염수플랜트(desalination)의 기본 요소설계, 원자로의 냉각계 통사고(LOCD)대책, 기타 냉각탑, 탱크가열, 증발기(evaporator), 건조장치(drier), 각종 기계, 화공 공정장치 설계 등 매우 광범위한 기술파급 효과도 기대할 수 있으므로 관련 기술자들의 많은 관심을 기대한다.

  • PDF

A study on the program development for optimizing the supply and exhaust port opening ratio in road tunnels with transverse ventilation system (횡류식 도로터널의 급배기구 개도율 최적화 프로그램 개발 연구)

  • Jo, Hyeong-Je;Chun, Kyu-Myung;Min, Dea-Kee;Kim, Jong-Won;Beak, Jong-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.517-532
    • /
    • 2017
  • The transverse ventilation system, commonly applied to urban tunnel, is necessary to be distributed with airflow uniformly. In this study, we developed a program that can optimize the opening ratio of ports to ensure ventilation performance of design criteria through a uniform airflow distribution even though ventilation interval becomes longer. And program's prediction performance was verified by comparison with TUNVEN DUCT program. For comparison, Semi-transverse ventilation system was applied. Both programs predicted a similar port size and air flow distribution, and the variation range of the calculated values was 11.71% and 1.36%, respectively. This program is very useful for port optimization design of transverse and semi-transverse ventilation system, because it is possible to analyze various tunnel lengths and supply/exhaust port installation conditions.

Comparison of natural ventilation ability according to window configuration using CFD simulation (CFD 시뮬레이션을 이용한 연동온실의 환기창 조건별 자연환기 성능 비교)

  • 윤남규;김문기;남윤일
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.07a
    • /
    • pp.249-254
    • /
    • 2002
  • 온실에서 환기는 외기와의 공기교환을 통한 온도 및 습도의 조절뿐만 아니라 이산화탄소 등의 가스농도를 조절함으로써 온실내 공기의 쾌적성 확보와 실내기류의 형성으로 인한 작물의 생육촉진에도 중요한 역할을 담당한다. 그러므로, 작물생육환경의 최적화를 통한 품질향상 및 수확량 증대를 목적으로 하는 온실재배에 있어서 환기특성 분석 및 공기유동 예측은 가장 기본적인 설계요소라 할 수 있다. (중략)

  • PDF

환기용 부스 설계 최적화 검증

  • Jang, Ho-Jun
    • Proceeding of EDISON Challenge
    • /
    • 2016.11a
    • /
    • pp.85-89
    • /
    • 2016
  • 실제 환풍용 팬의 수치를 이용하여 환기용 부스의 형상에 대한 내부 유동의 변화 양상과 유동의 정상상태에 따른 해석결과 비교를 수행하였다. 벽면이 기울어진 형상이 직사각형 형상의 부스에 비해 나은 내부 흐름을 보여 환기용 부스에 더 적합한 형상임을 확인할 수 있었다. 비정상 유동과 정상 유동은 해석 결과에서 다소 차이를 보였으며, 이는 차후 실험을 통해 검증할 예정이다.

  • PDF

A fundamental study on the ventilation analysis method for the network-type tunnel - focused on the none hardy-cross method (네트워크형 터널의 환기해석 방법에 대한 기초연구-비 Hardy-Cross 방법을 중심으로)

  • Kim, Hyo-Gyu;Choi, Pan-Gyu;Ryu, Ji-Oh;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.3
    • /
    • pp.291-303
    • /
    • 2016
  • Recently, various forms of diverging sections in tunnels have been designed as the demand for underground passageway in urban areas increases. Therefore, the complexity of the ventilation system in tunnels with diverging sections requires a ventilation analysis method different from the conventional method for the straight tunnels. None of the domestic and foreign tunnel ventilation design standards specifies the method for the ventilation network analysis, and the numerical analysis methods have been most widely used. This paper aims at reviewing the ventilation network analytical method applicable as the design standard. The proposed method is based on the characteristic equations rather than the numerical analysis. Thanks to the advantages of easy application, the Hardy-Cross method has been widely applied in the fields of mine ventilation and tunnel ventilation. However, limitations with the cutting errors in the Taylor series expansion and the convergence problem mainly caused by the mesh selection algorithm have been reported. Therefore, this paper examines the applicability of the ventilation analysis method for network-type tunnels with the gradient method that can analyze flow rate and pressure simultaneously without the configuration of mesh. A simple ventilation analysis method for network-type tunnels is proposed.

성능위주의 배연설비를 위한 지하철 승강장 화재시뮬레이션에 관한 연구

  • 김용주;이동호;김종원;조정훈
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2001.11a
    • /
    • pp.225-231
    • /
    • 2001
  • 최근 인구 증대 및 도시 집중화에 따른 지상공간 부족의 대안 및 택지 이용도 효율 방안으로 지하공간 개발의 필요성이 증대되고 있다 특히 날로 증대되고 있는 지하공간에서의 문제점으로 설계 및 용도에 적합한 환기 시스템의 도입 및 운영의 미흡으로 공기질 악화 현상과 국민 보건상의 문제로 노출되고 있는 실정이다. 환기시스템은 일상적 공간환기는 물론 화재시의 배연기능을 포함한다. 따라서, 정상적인 작동(일반 환기)과는 별도로 비정상 환경(화재시의 배연)에서의 중요성이 인식되고 있다. 따라서, 시스템 설계 오류는 화재발생시 중대한 인명피해로 연결됨으로서 그 중요성은 아무리 강조하여도 지나침이 없다 이미 미국, 일본, 노르웨이 등의 선진 외국에서는 지하공간의 최적환경 개선은 국민 삶의 질 향상이라는 관점 하에 꾸준히 진행되어오고 있다. $^{(1~3)}$ 우리나라에서도 서울1기 지하철을 시작으로 교통난의 해소를 위하여 2005년까지 총연장 60km에 이를 것으로 전망됨에 따라 지하공간의 공기질 개선 및 화재시의 배연설비의 최적화가 요구된다.(중략)

  • PDF