The Study on Optimum Ventilation System during Long Tunnel Construction

굴착중인 장대터널내 최적의 환기시스템에 대한 연구

  • Published : 2006.12.30

Abstract

In general, tunnel construction except for special cases such as very short tunnels must require an artificial ventilation system. Especially, it is efficient for long tunnels to use the combination of a proper ventilation system according to the progress of the excavation. Neung-Dong Tunnel of which length is 4,580m has been originally designed as using ventilation system of blower and exhaust mixture types. Since it has been expected to result in some problems, its design Is analyzed to find the way to improve ventilation system by estimating the amount of required fresh air, considering various ventilation mixture types, ventilation's fluidity analysis and contaminant's distribution by numerical analysis. Economical efficiency for each type is also reviewed to determine the best ventilation system.

길이가 대단히 짧은 터널을 제외하고는 터널을 시공하는 경우 일반적으로 인위적인 환기시스템이 필요하다. 특히 장대터널의 경우 굴착 진행에 따라 적절한 환기시스템을 조합해서 사용하는 것이 효과적이다. 터널 연장이 4,580m인 능동터널은 본래 송기식을 사용하는 것으로 설계를 했지만, 굴착이 진행됨에 따라 송기식만으로 환기하는 데에는 한계가 예상되어 별도의 방식 검토를 수행하였다. 굴착중 터널의 소요환기량을 산정하고 이 소요환기량과 선택가능한 여러 가지 경우의 환기조합방식을 사례볕로 구성한 뒤 환기량과 유동성을 해석하고 비교함으로써 경제적으로도 우수한 최적의 환기조합안을 도출하였다. 환기시스템을 결정하기 위하여 각 환기시스템에 대한 경제적 효율성 평가를 수행하였다.

Keywords

References

  1. 대한광업진흥공사, 1986, 갱내 골격구조 및 통기 개선을 위한 기초 연구, 대한광업진흥공사
  2. 이희근, 임한욱, 1995, 터널.지하공간 굴착공학, 구미서관, 서울, pp. 223-253
  3. 한국동력자원연구소, 1982, 갱내통기계통 개선 연구, 한국동력자원 연구소
  4. 한국동력자원연구소, 1986, 갱내 통기 종합시스템 연구, 한국동력자원 연구소